Abstract
Three pilot-scale membrane systems were operated using lake water as influent in this study. Microfiltration (MF) membrane with pore size of 0.01 m was used in Systen I of which filtration mode was set at constant pressure of $1kgf/cm^2$. Ultrafiltration (UF) membranes with molecular cutoff (MWCO) of 80,000 and 13,000 were used in System II-1 and II-2, respectively. Constant flow mode was applied at the range between 0.7 and $1.5m^3/m^2{\cdot}d$ (average of $1.1m^3/m^2${\cdot}d) for System II-1 and between 0.37 and $1.65m^3/m^2{\cdot}d$ (average of $1.18m^3/m^2{\cdot}d$) for System II-2. In System I, the flux changed from $1m^3/m^2{\cdot}d$ to $0.2m^3/m^2{\cdot}d$ during the operation time of 5 months. System II showed recovery of 94% under the allowable maximum pressure of $3kgf/cm^2$ during the same operation period. From these results, the efficient operation was observed in constant flow mode with respect to filtration time and recovery. Average filtrate turbidity showed 0.0071 NTU in System I and 0.0054 NTU in System II, which implied that high turbidity removal was obtained in both MF and UF systems with no significant difference between MF and UF. From the fact that membrane flux depends largely on membrane type and operation mode, a guideline of optimum design and operation should be suggested for application of membrane systems to full scale water treatment.
Keywords
Micro-filtration(MF); Ultra-Filtration(UF); Lake Water; Flux;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Jacangelo et al. (1995). Mechanism of Cryptosporidium, Giardia, and MS2 virus removal by MF and UF, Jour AWWA, 87(9), pp. 107-121
2 Madaeni, S. S. (1999). The application of membrane technology for water disinfection, Wat. Res., 33(2), pp. 301-308
3 膜分離技衛振興協會(2003). 淨水膜, 技報堂出版
4 Ventresque, C. et al.(2000). An outstanding feat of modern technology : the Mery-sur-Oise Nanofiltration Treatment Plant $(340,000m^3/d),$ Desalination, 131, pp. 1-16
5 김충환(2003). 막분리 시스템 도입시 예상되는 문제점 및 극복방안, 정수 막여과 국제 세미나
6 Edwards et al. (2001). Membrane solution to a 'significant risk' Cryptosporidium groundwater source, Desalination, 137, pp. 193-198