• 제목/요약/키워드: NO and $NO_2$ concentration

검색결과 7,922건 처리시간 0.036초

청정지역과 도시지역에서 $NO_2$ 광분해율이 오존농도에 미치는 영향에 관한 연구 (A Study on Effect of $NO_2$ Photodissociation rate on Ozone concentration from Rural and Urban Area in the Winter)

  • 이정주;이동범;윤중섭
    • 한국환경보건학회지
    • /
    • 제26권4호
    • /
    • pp.141-147
    • /
    • 2000
  • Due to a rapid in automobiles since the 1980’s, the concentration of NO, and HC has also increased along with cases of VOCs. These air pollutants have created $O_3$ concentration, which cause a harmful effect to the human health. This issue has become a subject of great public interest. For this paper, to compare the concentration of $O_3$, NO, N $O_2$ between the rural and urban area in the winter, the concentrations of each have been measuredevery hour during Jan.~Feb. 2000, 1998, respectively. To calculate the Photochemical Steady State, $\Phi$= $J_{N O_2}$[N $O_2$]/ $k_1$[NO][ $O_3$], temperature and $J_{ N O_2}$ has been determined. The NO concentration in the rural are showed at below 10 ppb while the NO concentration in the urban area showed maximum value of 90~120 ppb. But the $O_3$ concentration in both areas showed less than 30 ppb. The reason is that the N $O_2$ photodissiciation rate is low due to the temperature being below 2$^{\circ}C$ and less than 60 degrees in the solar zenith angle during the winter time, which makes the $O_3$ concentration in both areas, similar in the concentration level. N $O_2$ photodissociation rate in both ares showed maximum value of 3.0mW/$\textrm{cm}^2$. Values of $\Phi$ determined from the rural area was consistently the unity, approaching 1. But values of $\Phi$ determined from the urban was roughly higher than unity, approaching above 1or 2 for clear sky-high sun(10:00~16:00).

  • PDF

초기 톨루엔 농도가 톨루엔 -NOx- 공기 혼합물의 광산화 반응에 미치는 영향 - I. 가스상 물질의 변화 (Effect of Initial Toluene Concentration on the Photooxidation of Toluene -NOx- Air Mixture - I. Change of Gaseous Species)

  • 이영미;배귀남;이승복;김민철;문길주
    • 한국대기환경학회지
    • /
    • 제21권1호
    • /
    • pp.15-26
    • /
    • 2005
  • An experimental investigation of the gas-phase photooxidation of toluene-NO$_{x}$-air mixtures at sub-ppm concentrations has been carried out in a 6.9 m3, indoor smog chamber irradiated by blacklights. Measured parameters in the toluene-NO$_{x}$ experiments included $O_3$, NO, NO$_2$, NO$_{x}$, CO, SO$_2$ toluene, and air temperature. The initial toluene concentration ranged from 225 ppb to 991 ppb and the initial concentration ratio of toluene/NO$_{x}$ in ppbC/ppb was in the range of 5~20. It was found that the variation of gaseous species with irradiation time caused by the photooxidation of toluene-NO$_{x}$-air mixtures depended on the initial toluene concentration for similar concentration ratio of toluene/NO$_{x}$. The dependency of initial toluene concentration on the photooxidation of toluene-NO$_{x}$-air mixtures for toluene/NO$_{x}$=5~6 seemed to be opposite to that for toluene/NO$_{x}$=10~11. The arriving time at maximum ozone concentration depended on both initial toluene concentration and initial concentration ratio of toluene/NO$_{x}$. However, the maximum concentration of ozone formed by photooxidation depended only on the initial toluene concentration.luene concentration.

Sludge Pellet의 NOx제거특성에 미치는 온도의 영향 (Effect of heating temperature to remove NOx by sludge pellet)

  • 김영주;박재윤;박홍재;송원섭;박상현;배명환
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.922-926
    • /
    • 2002
  • In this paper, in order to investigate the catalytic effect of the sludge exhausted from waterworks as heating temperature for NOx removal, we measure NO, $NO_2$ concentration as increasing temperature of sludge pellets and applying high voltage to sludge pellets in a quartz-glass reactor at the same time. NO initial concentration is 100ppm balanced with air gas in a mixing chamber. The gas flow is 5[l/min] and the heating temperature of sludge pellets in a quartz-glass reactor is adjusted from $200[^{\circ}C]$ $400[^{\circ}C]$ to investigate the effect of sludge pellets for removal NOx$(NO+NO_2)$ as increasing temperature. $BaTiO_3$ pellets is filled in a packed-bed reactor for corona discharge to measure how much NOx$(NO+NO_2)$ is removed after generating $NO_2$ from the packed-bed reactor. AC[60Hz] voltage is supplied to the reactor for discharge. In the result, $NO_2$ concentration is decreased by sludge pellets without heating temperature for sludge pellets in case of sludge pellets done heat treatment, however NO concentration is almost the same to be compared NO initial concentration. As increasing heating temperature for sludge pellets, $NO_2$ adsorbed on the sludge surface done heat treatment is converted to NO by the thermal energy, so NO concentration is extremely increased by reduction decomposition of $NO_2$. Finally, We think the sludge is possible to use for reduction catalysts, however we need to study more about the possibility and endurance of sludge as catalysts for NOx removal.

  • PDF

초기 톨루엔 농도가 톨루엔- NOx-공기 혼합물의 광산화 반응에 미치는 영향 - II. 입자상 물질의 생성 및 성장 (Effect of Initial Toluene Concentration on the Photooxidation of Toluene-NOx-Air Mixture -II. Aerosol Formation and Growth)

  • 이영미;배귀남;이승복;김민철;문길주
    • 한국대기환경학회지
    • /
    • 제21권1호
    • /
    • pp.27-38
    • /
    • 2005
  • An experimental investigation of the gas-phase photooxidation of toluene-NO$_{x}$-air mixtures at sub-ppm concentrations has been carried out in a 6.9 ㎥, indoor smog chamber irradiated by blacklights. Measured parameters in the toluene-NO$_{x}$ experiments included aerosol, $O_3$, NO, NO$_2$, NO$_{x}$ CO, SO$_2$ toluene, and air temperature. The initial toluene concentration ranged from 225 ppb to 991 ppb and the initial concentration ratio of toluene/NO$_{x}$ in ppbC/ppb was in the range of 5~20. It was found that the variation of aerosol number concentration with irradiation time caused by the photooxidation of toluene-NO$_{x}$-air mixtures depended on the initial toluene concentration for similar concentration ratio of toluene/NO$_{x}$. The dependency of initial toluene concentration on the photooxidation of toluene-NO$_{x}$-air mixtures for toluene/NO$_{x}$= 5~6 seemed to be opposite to that for toluene/NO$_{x}$=10~11. The maximum number concentration of aerosols formed by photooxidation and the aerosol yield depended on both initial toluene concentration and initial concentration ratio of toluene/NO$_{x}$. In this study, the aerosol yield, defined as aerosol formed per unit toluene consumed, was found to be 0.01~0.16.und to be 0.01~0.16.

Plasma반응에 의한 NOx와 Ozone의 특성에 관한 연구 (A Study on Characteristics of NOx and Ozone by Plasma Reaction)

  • 최재욱;산외서수;최재진
    • 한국가스학회지
    • /
    • 제4권2호
    • /
    • pp.1-6
    • /
    • 2000
  • 가스중에 포함되어 있는 NOx를 안전하게 처리하기 위하여 침상전극을 취부한 플라즈마 반응기를 제작하여 장치의 특성을 실험적으로 조사하여 유효성을 검정하였다. 반응가스는 $NO/N_2$ 혼합가스와 $N_2/O_2$ 혼합가스를 이용하여 초기 NO농도를 설정하고, 유속을 2${\iota}$/min으로 공급하였다. NOx의 반응특성은 방전주입전력이 높을때는 NO의 농도가 감소하였으며, 산소의 농도 증가시에 NO의 분해가 용이하고 NO의 분해에너지 효율이 높았다. 또한 NO의 농도가 증가할 수록 NO의 분해에너지 효율은 높으나 분해율은 낮았다. 오존의 특성은 방전주입전력이 높을수록 오존의 생성이 증가하고, $NO/N_2$의 농도가 증가할 수록 오존의 생성량이 감소하였다.

  • PDF

천안시내 지하상가의 이산화질소 및 이산화황 농도 (Concentration of $NO_2$ and $SO_2$ of Underground Shopping Center in Chonan City)

  • 손부순;장봉기
    • 환경위생공학
    • /
    • 제15권1호
    • /
    • pp.102-108
    • /
    • 2000
  • Seasonal variation of $NO_2$ and $SO_2$ concentration was investigated at the underground shopping center in Chonan from October 1997 to August 1998. $NO_2$ and $SO_2$ was collected by personal air sampler at $0.4{\ell}/min$ and $0.5{\ell}/min$ respectively and analyzed using UV spectrophotometer at 550nm and 548nm individually. The results were as follows. 1. The concentration of $NO_2$ was 0.070 ppm in spring, 0.068 ppm in summer, 0.074 ppm in autumn and 0.085 ppm in winter. There was no significant difference. 2. The concentration of $SO_2$ was 0.0233 ppm in spring, 0.0216 ppm in summer, 0.0188 ppm in autumn and 0.0621 ppm in winter. There was significant difference (p<0.01). 3. The higher concentration of $NO_2$ and $SO_2$ gases were shown near the cafeteria (p<0.001, p<0.05). 4. The higher concentration of $NO_2$ was observed at indoor than the underground passage. There was significant difference between two values (p<0.01).

  • PDF

서울시 버스터미널의 이산화질소 및 아황산가스 농도 (Concentration of $NO_2$ and $SO_{2}$ of Bus Terminals in Seoul)

  • 손부순;장봉기;김영규
    • 환경위생공학
    • /
    • 제12권3호
    • /
    • pp.51-59
    • /
    • 1997
  • In this study, we researched the concentration of nitrogen dioxide($NO_{2}$) and sulfur dioxide($SO_{2}$) of indoor(waiting room) and outdoor(place of getting on the bus) at the bus terminals (Kang-Nam, Dong-Seoul and Nam-Bu) in Seoul to recognize the degree of pollution by exhaust gas of the diesel engine vehicles, and examine the factor that might affect air pollution of terminals. The concentration of $NO_{2}$ and $SO_{2}$ were measured in winter and summer, and the results of the analysis are as follows : The mean concentration of $NO_{2}$ was $57.49{\pm}21.86$ ppb and the concentration of outdoor with $64.10{\pm}27.69$ ppb was significantly higher than the indoor with $50.89{\pm}10.92$ ppb (p<0.05), and the highest with $73.54{\pm}25.54$ ppb at Kang-Nam terminal (p<0.01). The mean concentration of $NO_{2}$ was $62.80{\pm}24.74$ ppb in winter and $52.19{\pm}17.50$ ppb in summer, and had a not statistical difference. The mean concentration of $SO_{2}$ was $31.71{\pm}8.73$ ppb and the concentration of outdoor with $31.04{\pm}8.89$ ppb was similar to the indoor $32.29{\pm}8.70$ ppb, and the highest with $32.57{\pm}9.01$ ppb at Dong-Seoul terminal (p<0.05). The mean concentration of $SO_{2}$ in winter with $39.67{\pm}4.10$ ppb was significantly higher than in summer with $23.76{\pm}2.61$ ppb (p<0.01). The concentration of outdoor $NO_{2}$ at Kang-Nam terminal was 104, 84 ppb in winter and 81.20 ppb in summer, and had a statistical difference compared with the concentration of indoor $NO_{2}$ at Dong-Seoul and Nam-Bu terminals. The concentration of indoor $NO_{2}$ and $SO_{2}$ were higher than that of outdoor at Kang-Nam and Dong-Seoul terminals, but on the contrary, lower than that of outdoor at Nam-Bu terminal. The concentration of $NO_{2}$ and $SO_{2}$ at Nam-Bu terminal were lower than those at Kang-Nam and Dong-Seoul terminals. While the concentration of $SO_{2}$ show the large difference between winter and summer, that of $NO_{2}$ dose not.

  • PDF

선대 평판형 반응기에서 $NO_2$ 생성에 미치는 $O_2$의 영향 (The influence of $O_2$ concentration on the generation of $NO_2$ by using the wire-plate reactor)

  • 박재윤;김성진;김종달;이선재;하상태;한상보;이동훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2050-2052
    • /
    • 2000
  • In this paper, the effect of $O_2$ concentration on NO removal and $NO_2$ generation by corona discharge from simulated flue gas was measured and estimated for the wire-plate reactor. $NO_2$ removal rate was 0$\sim$30[%] under about 3.4[%] of oxygen concentration, however, it was difficult to remove NOx over 3.4[%] of oxygen concentration. It may be due to generate $NO_2$ from $N_2$ and $O_2$ molecules and converse NO to $NO_2$ by 0 and $O_3$. Magnetic field applied to electric field in plasma was very effective for NOx removal under 2[%] of $O_2$ concentration.

  • PDF

복합생물막 반응기를 이용한 하수처리시 탈질화 특성 (Characteristics of Denitrification from Municipal Wastewater Treatment using a Combined Fixed Film Reactor (CFFR) Process)

  • 이종현;남해욱;김영규;박태주
    • 한국환경과학회지
    • /
    • 제8권1호
    • /
    • pp.107-113
    • /
    • 1999
  • A new biological nutrient removal system combining $A^2/O$ process with fixed film was developed in this work and the characteristics of denitrification were especially investigated in the combined fixed film reactor(CFFR). Media was added in the anaerobic, anoxic and aerobic reactors, respectively. Tests were made to establish the effluent level of $NO_x-N$, COD, DO and nitrite effects on $NO_x-N$ removal in the CFFR by decreasing hydraulic retention time (HRT) from 10.0 to 3.5 hours and by increasing internal recycle ratio form 0% to 200%. The influent was synthesized to levels similar to the average influent of municipal wastewater treatment plants in Korea. SARAN media with a porosity of 96.3% was packed 40% / 130% / 25% based on its reactor volume, respectively. It was found that COD rarely limited dentrification in the anoxic reactor because of high $C/NO_x/-N$ ratio in the anoxic reactor, while DO concentration in the anoxic reactor and $NO_2-N/NO_x/-N$ from the aerobic effluent inhibited denitrification in the anoxic reactor. It was proved that the critical points of DO concentration in the anoxic reactor and $NO_2-N/NO_x/-N$ from the aerobic effluent were 0.15mg/L and 10%, respectively. As the internal recycle ratio increased, DO concentration in the anoxic reactor and $NO_2-N/NO_x/-N$ from the aerobic effluent increased. Especially, at the condition of internal recycle ratio, 200%, DO concentration in the anoxic reactor and $NO_2-N/NO_x/-N$ from the aerobic effluent exceeded the critical points of 0.15mg/L and 10%, respectively. Then, denitrification efficiency considerably decreased. Consequently, it was represented that the control of DO concentration in the anoxic reactor and $NO_2-N/NO_x/-N$ from the aerobic effluent can assure effective denitrification.

  • PDF

서울 도심대기의 NO, NO2와 O3 사이의 대기화학적 특성 연구 (Characteristics in Atmospheric Chemistry between NO, NO2 and O3 at an Urban Site during MAPS (Megacity Air Pollution Study)-Seoul, Korea)

  • 김득수;정진상;안준영
    • 한국대기환경학회지
    • /
    • 제32권4호
    • /
    • pp.422-434
    • /
    • 2016
  • This study was conducted to understand roles of $NO_x(=NO+NO_2)$ on high $O_3$ episodes at an urban monitoring station in Seoul. Concentrations of NO, $NO_2$, $NO_y$ and $O_3$ were measured intensively at KIST monitoring station which located at urban center in Seoul metropolitan area during May 18~June 13, 2015. Sampling period was planed because high $O_3$ and PM occurred frequently during from late spring to early summer months in Seoul. The experimental site locates in NW from center of Seoul and is surrounded by residential area. Belt highway of the city runs from north to west side nearby experimental site. Vehicle exhaust emissions due to heavy traffic influenced $NO_x$ concentration at the site during northwesterly wind. Specific $NO_2$ concentration was measured by Blue Light photolytic converter, and it was compared to $NO_2$ concentration measured by molybedenum converter. $[NO_2]_{phtolysis}$ was usually lower than $[NO_2]_{molybedenum}$ during the experiment period; however their diurnal variations were very similar. The linear relationship between these $NO_2$ concentrations was found to be $[NO_2]_{phtolysis}$=0.64 $[NO_2]_{molybedenum}$ - 2.6, $r^2$=0.83 during May 16~8, 2015. The difference between $NO_2$ by molybdenum converter and by photolytic converter (${\Delta}NO_2=[NO_2]_{molybedenum}-[NO_2]_{phtolysis}$) accounted for residual $NO_y$ which can represent $NO_z$ (=$NO_y-NO_x$). $O_3$ concentration showed typical daily trend which has maximum at late afternoon and minimum during the night. $O_3$ increased at a rate of 7 ppb/hr since 8 am. and reached the maximum concentration (~80 ppb) at 3 pm.. The diurnal pattern of $O_3$ was inversely related with that of $NO_2$, suggesting that the formation of $O_3$ was the result of photochemical activity of $NO_2$.