• Title/Summary/Keyword: NEMA.s

Search Result 61, Processing Time 0.028 seconds

Control Effect of Root-knot Nematode (Meloidogyne incognita) by Biological Nematicide (생물학적 살선충제의 뿌리혹선충 (Meloidogyne incognita) 방제 효과)

  • Park, Moon-Hyun;Walpola, Buddhi Charana;Kim, Sun-Joong;Yoon, Min-Ho
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.2
    • /
    • pp.162-168
    • /
    • 2012
  • An nematophagous fungi Arthrobotrys thaumasia Nema-1 and Bacillus subtilis C-9, which degrade the collagen and gelatin, were isolated from horticulture plantation soil in Kyungpook Sungju-gun Seonnam-myun and Chungnam Gongju-gun Woosung-myun to develop biological nematode pesticide. When $5,000mg\;kg^{-1}$ of A. thaumasia Nema-1 nematicide powder ($7.0{\times}10^3cfu\;g^{-1}$) was treated to pot including Meloidogyne incognita, the number of nematode's egg mass, which is a index of nematicidal activity, decreased to 35% compared to control. While the number of nematode's egg mass decreased to 67% by treating the nematicide powder mixture of $5,000mg\;kg^{-1}$ Nema-1 and B. subtilis C-9 ($8.5{\times}10^5cfu\;g^{-1}$). Furthermore the number of nematode's egg mass of the mixture containing cinnamon extract $10mg\;kg^{-1}$, each $5,000mg\;kg^{-1}$ of Nema-1 and C-9 nematicide powder was decreased to 84%, comparing to the result showed the number of nematode's egg mass decreased to 24%, by the treatment of chemical nemato pesticide Fosthiazate $24mg\;kg^{-1}$. These results suggested the mixture of microorganisms and plant extract was more effective biological nematicide than the case of only microorganism or plant extract for nematode control.

Evaluation of Physical Characteristics of Discovery ST scanner Using NEMA NU2-2001 Standard (NEMA NU2-2001을 이용한 PET-CT 스캐너의 물리적 특성평가)

  • Lee, Byeong-Il
    • Journal of Integrative Natural Science
    • /
    • v.1 no.2
    • /
    • pp.79-83
    • /
    • 2008
  • As a new standard for performance measurement, NEMA NU2-2001 was presented recently. In this study, I investigated the spatial resolution, sensitivity, scatter fraction, and noise equivalent count ratio (NECR) in order to know the information of physical characteristics and system performance of GE discovery ST using this new standard. Bismuth germinate crystals ($6{\times}6$ array, $6.3mm{\times}6.3mm{\times}30mm$) were used in discovery ST (energy window:375-650 keV, coincidence window:11.7 nsec). To measure the sensitivity, five aluminum sleeves (Data Spectrum Corp., Chapel Hill, NC., USA, thickness:1.25 mm)-NEMA sensitivity phantom- filled with F-18 solution were used. Successive measurements in 2D and 3D acquisition mode were made with a line source at the center of transaxial field of view and 10 cm off from the center until the count was over 500,000. Spatial resolution was estimated using a point source (F-18, 0.1 mCi) at different locations in the FOV. Scatter fraction and NECR was tested using a NEMA scatter phantom. Dynamic data were acquired for 7 half-lives using F-18 solution. And true to background ratio was averaged at last three frames when the random rate was as small as ignorable for the calculation of scatter fraction. We anticipate this overall evaluated results could be used for the quality assurance and optimized image acquisition for clinical research.

  • PDF

Analysis of Steep slope Disaster Sites using Geographic Information System (GIS를 활용한 급경사지 재해현장 분석 -전북 무주군, 장수군, 진안군 중심으로-)

  • Lee, Min-Seok;Oh, Jeong-Rim;Park, Dug-Keun;Kim, Man-Il
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.940-945
    • /
    • 2010
  • There are human casualties that caused by slope-stability related disasters such as landslide and debris flow during typhoon and rainy season every year in Korea. These disaster sites can be analyzed systematically using digital topographic data and aerial photogrammetry. In this study, geographical factors such as slope degree, geology, height, and soil depth are analyzed in four landslide-disaster sites from Muju, Jinan, and Jangsu County based on digital elevation maps generated by ArcGIS. Each site showed different characteristics in geology and geography and it is found that GIS can be utilized for the visualization of steep-slope failure areas.

  • PDF

A Study on the Output Filter Design to meet NEMA Standard for a SiC MOSFET Inverter Fed Motor Drive Applications (전동기 구동용 SiC MOSFET 인버터의 NEMA 규격 만족을 위한 출력 필터 구조에 관한 연구)

  • Baek, Seunghoon;Cho, Younghoon;Cho, Byung-Geuk;Hong, Chanook
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.53-54
    • /
    • 2016
  • 본 논문은 전동기 구동용 SiC MOSFET 인버터의 NEMA(National equipment manufacturer's association) 규격 만족을 위한 출력 필터 구조에 따른 영향을 분석한다. 구조와 목적에 따라 정현파 필터와 dv/dt 필터를 적용하여 380V, 60Hz, 3.7kW급 유도 전동기를 대상으로 실험을 수행하여 설계한 필터가 NEMA 규격을 만족시킬 수 있을 뿐만 아니라 전동기 누설전류를 감소시켜 효율까지 향상시킬 수 있음을 확인하였다.

  • PDF

Multi-Objective Optimal Design of a NEMA Design D Three-phase Induction Machine Utilizing Gaussian-MOPSO Algorithm

  • Zhang, Dianhai;Ren, Ziyan;Koh, Chang-Seop
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.184-189
    • /
    • 2014
  • This paper presents a multi-objective optimization approach to design rotor slot geometry of three-phase squirrel cage induction machine to achieve NEMA design D torque-speed (T-S) characteristics with high efficiency. The multi-objective Particle Swarm Optimization (MOPSO) algorithm combined with the adaptive response surface method and Latin hypercube sampling strategy is applied to obtain the Pareto optimal designs. In order to demonstrate the validity of the suggested optimal algorithm, an application to rotor slot design of three-phase induction motor is presented.

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

Evaluation of 18F-FDG PET/CT Image Distortion by NEMA IEC Body Phantom (NEMA IEC Body Phantom을 이용한 18F-FDG PET/CT 영상의 왜곡 평가)

  • Park, jooncheol;Yang, hanjoon
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.4
    • /
    • pp.427-433
    • /
    • 2013
  • Recently, 18F-FDG PET based CT scan was a critical examination that the after, before plan diagnosis and treatment of tumors. But, due to the distortion of SUV that should be proportional to the metabolic rate of glucose in the tumor, the other measurement methods are being on study. In this study, compared the degree of distortion of SUV that according to the volume of the tumor analysis ROI and VOI using the NEMA IEC Phantom. The results, the SUVmax, mean value are rapidly decreased with threshold value 500 mm2 interval of the ROI analysis, 1500 mm3 interval of the VOI analysis. When compared SUVmax value SUVmean, ROI and VOI analysis VOI measurements was 1.077 times higher SUVmax was 0.981 times highe compared to the value of the ROI measurement. Compare MTV, SUV 2.0 as measured by the volume of the VOI to Volume showed a slightly higher results(Volume / MTV = $93.4 %{\pm}14.8 %$). Considering the above results, Tumor evaluation by 18F-FDG PET / CT scan Consider each threshold value should be analyzed due to larger SUV's Distortion depending on the size of the tumor. VOI analysis is recommended. because it showed the VOI analysis is higher than the ROI analysis SUVmax and lower SUVmean due to VOI analysis than once as a measure of the wider area as measured ROI analysis. MTV (R2 = 0.999), a result close to the actual size of the tumor. but, more research is needed in this regard, because SUV according to the standards of value are affected.

Picture archiving and communications systems development and performance results

  • Nam, Ji-Seung;Ralph Martinez
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10b
    • /
    • pp.1796-1800
    • /
    • 1991
  • Picture Archiving and Communication Systems(PACS) provide an integration of digital imaging information in a hospital, which encompasses various imaging equipment, viewing workstations, database archive systems, and a high speed fiber optic network. One of the most important requirements for integration is the standardization of communication protocols to connect devices from different vendors. Since 1985, the ACR-NEMA standard provides a hardware interface, a set of software commands, and a consistent set of data formats for point-to-point interconnection of medical equipment. However, it has been shown to be inadequate for PACS networking environments, because of its point-to-point nature and its inflexibility to allow other services and protocols in the future. Based on previous experience of PACS developments in The University of Arizona, a new communication protocol for PACS networks has been suggested to the ACR-NEMA Working Group VI. The defined PACS protocol is intended to facilitate the development of PACS's capable of interfacing with other hospital information systems. Also, it is intended to allow the creation of diagnostic information data bases which can be interrogated by a variety of distributed devices. A particularly important goal is to support communications in a multivendor environment. The new protocol specifications are defined primarily as a combination of the International Organization for Standardization / Open Systems Interconnection (ISO/OSI) protocols and the data format portion of ACR-NEMA standard. This paper addresses the specification and implementation of the proposed PACS protocol into network node. The protocol specification, which covers Presentation, Session, Transport, and Network layers, is summarized briefly. The implementation has natural extentions to Global PACS environments. The protocol implementation is discussed based on our implementation efforts in the UNIX Operating System Environment. At the same time, results of performance evaluation are presented to demonstrate the implementation of defined protocol. The testing of performance analysis is performed on the PACS prototype node.

  • PDF

A Study for the Necessity of Restructuring Korea's Emergency Management Organization - Focused on Disaster.Emergency Preparation and Civil Defence Affairs - (정부의 위기관리 조직 재설계 필요성 연구 - 재난.비상대비.민방위업무를 중심으로 -)

  • Kim, Kook-Rae
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.1-8
    • /
    • 2008
  • With a purpose to set up an efficient national security system for both at war-time and peace-time, President Lee's government transferred the emergency management function from the Office of Prime Minister to Ministry of Public Administration and Security (MOPAS). As a result national emergency management system has been changed into diversified management system ; the function of comprehensive disaster control, emergency preparation to MOPAS, fire, civil defense and disaster management to NEMA and anti-terrorism to NIS, which produce another inefficiency. For this reason, this research presents desirable improvement alternatives through scrutinizing current governmental function and structure.

Fire Occurrence Pattern Analysis and Fire Risk Calculation of Jinju City (진주시 화재발생 패턴분석과 위험등급 산출)

  • Bae, Gyu Han;Yoo, Hwan Hee
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.22 no.4
    • /
    • pp.151-157
    • /
    • 2014
  • Diverse and complex facilities have been on the increase in urban areas in accordance with rapid urbanization. Along the lines of the increase in facilities, the risk of fire has increased. In particular, fire accidents as well as traffic accidents accounted for the highest rate in artificial disasters. Therefore, the National Fire Information Systems managed by the National Emergency Management Agency (NEMA) appeared for the effective fire management. The NEMA has provided the public with the Internet services regarding information about fire outbreak since 2007. This study acquired data from both NEMA and the Jinju City Fire Department. It constructed the fire data of Jinju City and calculated the change in spatial density targeting fire, occurred in Jinju city with a view to examining the fire risk of facilities by conducting a time series analysis on the trends of fire outbreak over a span of periods between 2007 and 2013. It also conducted an analysis of Moran's I, Getis-Ord Gi. Therefore, it came to select higher hot spots in terms of fire location and fire density. In addition, it attempted to calculate the levels of fire hazard by drawing up the matrix of personal injury and property damage, depending on facilities to present the methods, which can predict the risk of fire occurrence in urban areas.