• Title/Summary/Keyword: NEMA

Search Result 155, Processing Time 0.028 seconds

Evaluation of 18F-FDG PET/CT Image Distortion by NEMA IEC Body Phantom (NEMA IEC Body Phantom을 이용한 18F-FDG PET/CT 영상의 왜곡 평가)

  • Park, jooncheol;Yang, hanjoon
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.4
    • /
    • pp.427-433
    • /
    • 2013
  • Recently, 18F-FDG PET based CT scan was a critical examination that the after, before plan diagnosis and treatment of tumors. But, due to the distortion of SUV that should be proportional to the metabolic rate of glucose in the tumor, the other measurement methods are being on study. In this study, compared the degree of distortion of SUV that according to the volume of the tumor analysis ROI and VOI using the NEMA IEC Phantom. The results, the SUVmax, mean value are rapidly decreased with threshold value 500 mm2 interval of the ROI analysis, 1500 mm3 interval of the VOI analysis. When compared SUVmax value SUVmean, ROI and VOI analysis VOI measurements was 1.077 times higher SUVmax was 0.981 times highe compared to the value of the ROI measurement. Compare MTV, SUV 2.0 as measured by the volume of the VOI to Volume showed a slightly higher results(Volume / MTV = $93.4 %{\pm}14.8 %$). Considering the above results, Tumor evaluation by 18F-FDG PET / CT scan Consider each threshold value should be analyzed due to larger SUV's Distortion depending on the size of the tumor. VOI analysis is recommended. because it showed the VOI analysis is higher than the ROI analysis SUVmax and lower SUVmean due to VOI analysis than once as a measure of the wider area as measured ROI analysis. MTV (R2 = 0.999), a result close to the actual size of the tumor. but, more research is needed in this regard, because SUV according to the standards of value are affected.

Analysis of accidents due to Fires in Korea, 1997-2006 (1997-2006, 한국에서 발생한 화재사고 분석)

  • Chung, Yeong-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.526-533
    • /
    • 2009
  • Fire accidents reported to the National Emergency Management Agency (NEMA) during 1997.2006 in Korea are investigated. A survey of 23523 accidents due to fires is presented. Statistical comparisons based on the type of accidents and the causes of fires are analysed. The results indicated that 27.5% of the total number of fires are residental houses and apartments and 18.0% were motor vehicles. Electricity was classified to be the highest cause of fire ignition sourses and smoking was the second source of ignition.

  • PDF

Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT) (3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Byeong-Il;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.318-324
    • /
    • 2004
  • Purpose: Philips GEMINI is a newly introduced whole-body GSO PET/CT scanner. In this study, performance of the scanner including spatial resolution, sensitivity, scatter fraction, noise equivalent count ratio (NECR) was measured utilizing NEMA NU2-2001 standard protocol and compared with performance of LSO, BGO crystal scanner. Methods: GEMINI is composed of the Philips ALLEGRO PET and MX8000 D multi-slice CT scanners. The PET scanner has 28 detector segments which have an array of 29 by 22 GSO crystals ($4{\times}6{\times}20$ mm), covering axial FOV of 18 cm. PET data to measure spatial resolution, sensitivity, scatter fraction, and NECR were acquired in 3D mode according to the NEMA NU2 protocols (coincidence window: 8 ns, energy window: $409[\sim}664$ keV). For the measurement of spatial resolution, images were reconstructed with FBP using ramp filter and an iterative reconstruction algorithm, 3D RAMLA. Data for sensitivity measurement were acquired using NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves after we confirmed that dead time loss did not exceed 1%. To measure NECR and scatter fraction, 1110 MBq of F-18 solution was injected into a NEMA scatter phantom with a length of 70 cm and dynamic scan with 20-min frame duration was acquired for 7 half-lives. Oblique sinograms were collapsed into transaxial slices using single slice rebinning method, and true to background (scatter+random) ratio for each slice and frame was estimated. Scatter fraction was determined by averaging the true to background ratio of last 3 frames in which the dead time loss was below 1%. Results: Transverse and axial resolutions at 1cm radius were (1) 5.3 and 6.5 mm (FBP), (2) 5.1 and 5.9 mm (3D RAMLA). Transverse radial, transverse tangential, and axial resolution at 10 cm were (1) 5.7, 5.7, and 7.0 mm (FBP), (2) 5.4, 5.4, and 6.4 mm (3D RAMLA). Attenuation free values of sensitivity were 3,620 counts/sec/MBq at the center of transaxial FOV and 4,324 counts/sec/MBq at 10 cm offset from the center. Scatter fraction was 40.6%, and peak true count rate and NECR were 88.9 kcps @ 12.9 kBq/mL and 34.3 kcps @ 8.84 kBq/mL. These characteristics are better than that of ECAT EXACT PET scanner with BGO crystal. Conclusion: The results of this field test demonstrate high resolution, sensitivity and count rate performance of the 3D PET/CT scanner with GSO crystal. The data provided here will be useful for the comparative study with other 3D PET/CT scanners using BGO or LSO crystals.

Study of water drowning death patients on clinical care and prevention (수중익사 사망 환자의 임상 치료 및 예방에 대한 연구)

  • Kim, Seon-Rye;Cho, Byung-Jun;Ko, Jang-Sik
    • Journal of Digital Convergence
    • /
    • v.14 no.5
    • /
    • pp.427-432
    • /
    • 2016
  • The purpose of this study was to investigate drowning death patients on clinical care and prevention. Drowning accidents that occurred in the Republic of Korea were identified by using the Emergency Activity Daily Report Data from the National Emergency Management Agency (NEMA). The age of drowning accidents was 20-29 years (25.4%). Drowning cases for the months of August was 17.6%. The main circumstance involved in the drowning cases was swimming (45.0%). Half of swimming incidents related the drowning accidents of people attempting to save a life of a family member or friend from the water. The most common location was at a lake or reservoir (40.2%). Drowning is a main cause of accidents in the Republic of Korea. Preventive strategies that may be beneficial for persons contain life jackets or life rings supply, upgrading swimming ability, placing lifeguards based on public education activities.

Picture archiving and communications systems development and performance results

  • Nam, Ji-Seung;Ralph Martinez
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10b
    • /
    • pp.1796-1800
    • /
    • 1991
  • Picture Archiving and Communication Systems(PACS) provide an integration of digital imaging information in a hospital, which encompasses various imaging equipment, viewing workstations, database archive systems, and a high speed fiber optic network. One of the most important requirements for integration is the standardization of communication protocols to connect devices from different vendors. Since 1985, the ACR-NEMA standard provides a hardware interface, a set of software commands, and a consistent set of data formats for point-to-point interconnection of medical equipment. However, it has been shown to be inadequate for PACS networking environments, because of its point-to-point nature and its inflexibility to allow other services and protocols in the future. Based on previous experience of PACS developments in The University of Arizona, a new communication protocol for PACS networks has been suggested to the ACR-NEMA Working Group VI. The defined PACS protocol is intended to facilitate the development of PACS's capable of interfacing with other hospital information systems. Also, it is intended to allow the creation of diagnostic information data bases which can be interrogated by a variety of distributed devices. A particularly important goal is to support communications in a multivendor environment. The new protocol specifications are defined primarily as a combination of the International Organization for Standardization / Open Systems Interconnection (ISO/OSI) protocols and the data format portion of ACR-NEMA standard. This paper addresses the specification and implementation of the proposed PACS protocol into network node. The protocol specification, which covers Presentation, Session, Transport, and Network layers, is summarized briefly. The implementation has natural extentions to Global PACS environments. The protocol implementation is discussed based on our implementation efforts in the UNIX Operating System Environment. At the same time, results of performance evaluation are presented to demonstrate the implementation of defined protocol. The testing of performance analysis is performed on the PACS prototype node.

  • PDF

Comparison of PET/MR image quality with and without point spread function algorithm according to reconstruction type (재구성 방법(점 확산함수 적용 유무)에 따른 PET/MR 영상 평가)

  • Park, Chan Rok;Moon, Il Sang;Noh, Gyeong Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.43-45
    • /
    • 2018
  • Purpose In this study, we evaluated image by applying with and without point spread function algorithm(PSF) according to reconstruction type. Materials and Methods Biograph mMR (Siemens, Germany) was used as PET/MR scanner. For phantom study, we used NEMA IEC Body phantom maintaining radioactivity ratio (hotsphere:background = 8:1). To evaluate phantom image quality, percent contrast recovery and signal to noise ratio (SNR) were used by drawing ROI to 4 spheres. In clinical study, the 20 patients who underwent simultaneous PET/MR was selected and set the ROI at liver. we evaluated images as SNR. Results In the phantom results, The percent contrast recovery applying PSF algoritm was high 5 % compared to without PSF algoritm and SNR was also high 11 %. In the clinical study result, we confirmed that The SNR applying PSF algoritm was high 5 % compared to without PSF algoritm. Conclusion We need to simulate a lot of phantom study and clinical analysis to improve image quality for PET/MRI.

Improving the PR System of the Disaster Management -Contents Analysis of 'Monthly Publication of the Disaster Analysis & Prospect'in NEMA- (재난관리 효과성 제고를 위한 재난관리 PR체계 개선방안 -소방방재청 '월간재난종합상황 분석 및 전망'의 내용 분석-)

  • Lee, Ye-Jong;Lee, Ju-Ho;Byun, Sung-Soo;Lee, Jae-Eun
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.4
    • /
    • pp.338-346
    • /
    • 2011
  • The purpose of this article is improving the PR System of the Disaster Management. For achieving the purpose, this article deals with Monthly Publication of the Disaster Analysis & Prospect pressed by the NEMA and DHS TODAY pressed by the DHS and use to contents analysis as methodology. This study selects sorts, management steps, and learning of disaster which are useful in analyzing contents by the krkwic program. This study suggests how to improve PR System of disaster management focusing on contents of the PR media.