• Title/Summary/Keyword: NEMA

Search Result 155, Processing Time 0.029 seconds

Evaluation of Physical Characteristics of Discovery ST scanner Using NEMA NU2-2001 Standard (NEMA NU2-2001을 이용한 PET-CT 스캐너의 물리적 특성평가)

  • Lee, Byeong-Il
    • Journal of Integrative Natural Science
    • /
    • v.1 no.2
    • /
    • pp.79-83
    • /
    • 2008
  • As a new standard for performance measurement, NEMA NU2-2001 was presented recently. In this study, I investigated the spatial resolution, sensitivity, scatter fraction, and noise equivalent count ratio (NECR) in order to know the information of physical characteristics and system performance of GE discovery ST using this new standard. Bismuth germinate crystals ($6{\times}6$ array, $6.3mm{\times}6.3mm{\times}30mm$) were used in discovery ST (energy window:375-650 keV, coincidence window:11.7 nsec). To measure the sensitivity, five aluminum sleeves (Data Spectrum Corp., Chapel Hill, NC., USA, thickness:1.25 mm)-NEMA sensitivity phantom- filled with F-18 solution were used. Successive measurements in 2D and 3D acquisition mode were made with a line source at the center of transaxial field of view and 10 cm off from the center until the count was over 500,000. Spatial resolution was estimated using a point source (F-18, 0.1 mCi) at different locations in the FOV. Scatter fraction and NECR was tested using a NEMA scatter phantom. Dynamic data were acquired for 7 half-lives using F-18 solution. And true to background ratio was averaged at last three frames when the random rate was as small as ignorable for the calculation of scatter fraction. We anticipate this overall evaluated results could be used for the quality assurance and optimized image acquisition for clinical research.

  • PDF

Control Effect of Root-knot Nematode (Meloidogyne incognita) by Biological Nematicide (생물학적 살선충제의 뿌리혹선충 (Meloidogyne incognita) 방제 효과)

  • Park, Moon-Hyun;Walpola, Buddhi Charana;Kim, Sun-Joong;Yoon, Min-Ho
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.2
    • /
    • pp.162-168
    • /
    • 2012
  • An nematophagous fungi Arthrobotrys thaumasia Nema-1 and Bacillus subtilis C-9, which degrade the collagen and gelatin, were isolated from horticulture plantation soil in Kyungpook Sungju-gun Seonnam-myun and Chungnam Gongju-gun Woosung-myun to develop biological nematode pesticide. When $5,000mg\;kg^{-1}$ of A. thaumasia Nema-1 nematicide powder ($7.0{\times}10^3cfu\;g^{-1}$) was treated to pot including Meloidogyne incognita, the number of nematode's egg mass, which is a index of nematicidal activity, decreased to 35% compared to control. While the number of nematode's egg mass decreased to 67% by treating the nematicide powder mixture of $5,000mg\;kg^{-1}$ Nema-1 and B. subtilis C-9 ($8.5{\times}10^5cfu\;g^{-1}$). Furthermore the number of nematode's egg mass of the mixture containing cinnamon extract $10mg\;kg^{-1}$, each $5,000mg\;kg^{-1}$ of Nema-1 and C-9 nematicide powder was decreased to 84%, comparing to the result showed the number of nematode's egg mass decreased to 24%, by the treatment of chemical nemato pesticide Fosthiazate $24mg\;kg^{-1}$. These results suggested the mixture of microorganisms and plant extract was more effective biological nematicide than the case of only microorganism or plant extract for nematode control.

Nematicidal Effect of Root-knot Nematode (Meloidogyne incognita) by Biological Nematicide (생물학적 선충 방제제를 이용한 고구마 뿌리혹선충 (Meloidogyne incognita)의 방제효과)

  • Park, Moon-Hyun;Kim, Jin-Kwang;Choi, Won-Ho;Yoon, Min-Ho
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.2
    • /
    • pp.228-235
    • /
    • 2011
  • An nematophagous fungi Arthrobotrys thaumasia Nema-1 and Pseudomonas putida C-5, which degrade the collagen and gelatin, was isolated from controlled horticultural soils in Seonnam-myun, Sungju-gun, Kyungpook and Woosung-myun, Gongju-shi, Chungnam to develop biological nematode pesticide. When $5,000mL\;L^{-1}$ of A. thaumasia Nema-1 culture was treated to Meloidogyne incognita, the nematicidal activity resulted in 55% at 72 hours after treatment. While the nematicidal activity increased to 65% by treating the culture mixture of $5,000mL\;L^{-1}$ Nema-1 and P. putida C-5 after 72 hours. Furthermore, the nematicidal activity of the mixture containing cinnamon extract $50mg\;L^{-1}$, each $5,000mL\;L^{-1}$ of Nema-1 and C-5 culture was elevated to 89% at 72 hours after treatment, comparing to the result showed 17% and 57% of the nematicidal activity, respectively by the treatment of chemical nemato pesticide Fosthiazate $50mg\;L^{-1}$ and neem oil $2,000mL\;L^{-1}$. These results suggested that the mixture of microorganisms and plant extract were more effective biological nematicide than the case of only microorganism or plant extract for nematode control.

Assessment of Factors affecting Steep-slope Failure using Artificial Neural Network (인공신경망을 활용한 급경사지 붕괴유발인자 평가)

  • Song, Young-Karb;Oh, Jeong-Rim;Park, Dug-Keun;Son, Young-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.1342-1348
    • /
    • 2010
  • Currently available evaluation checklists are developed for specific purposed using different parameters and items determined by different weighting factors. Those items with different weighting are sometimes said that they are based on the engineering judgement and leap of faith and, therefore, there is a limitation to adapt those checklists for slope-stability evaluation in the field. This study reviews factors affecting slope stability, analyze the relationship between those factors and slope failures using artificial neural network, and proposed a slope-stability evaluation model for adequate weighting for the factors.

  • PDF

Analysis of Steep slope Disaster Sites using Geographic Information System (GIS를 활용한 급경사지 재해현장 분석 -전북 무주군, 장수군, 진안군 중심으로-)

  • Lee, Min-Seok;Oh, Jeong-Rim;Park, Dug-Keun;Kim, Man-Il
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.940-945
    • /
    • 2010
  • There are human casualties that caused by slope-stability related disasters such as landslide and debris flow during typhoon and rainy season every year in Korea. These disaster sites can be analyzed systematically using digital topographic data and aerial photogrammetry. In this study, geographical factors such as slope degree, geology, height, and soil depth are analyzed in four landslide-disaster sites from Muju, Jinan, and Jangsu County based on digital elevation maps generated by ArcGIS. Each site showed different characteristics in geology and geography and it is found that GIS can be utilized for the visualization of steep-slope failure areas.

  • PDF

Improvement of Field Assessment List for Slope-stability Estimation (국내외 급경사지 평가표 분석을 통한 개선방안 연구)

  • Son, Young-Jin;Park, Dug-Keun;Oh, Jeong-Rim;Song, Young-Karb
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.509-522
    • /
    • 2010
  • There is a increasing trend in disaster occurrence due to steep-slope failures in urban area during typhoon and torrential rain season in Korea. The underlying hazards that cause slope failure are mainly linked with urbanization and industrialization. To minimize the disaster damages by slope failure, objective and unified evaluation approached are desired. Since currently available evaluation checklists are developed for specific purposed, there is a limitation to adapt those checklists for stability evaluation in natural terrain. This study proposes an improved evaluation checklist based on the comparison of previous checklists and applicability and feasibility are analyzed implementing field application.

  • PDF

A Study on the Output Filter Design to meet NEMA Standard for a SiC MOSFET Inverter Fed Motor Drive Applications (전동기 구동용 SiC MOSFET 인버터의 NEMA 규격 만족을 위한 출력 필터 구조에 관한 연구)

  • Baek, Seunghoon;Cho, Younghoon;Cho, Byung-Geuk;Hong, Chanook
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.53-54
    • /
    • 2016
  • 본 논문은 전동기 구동용 SiC MOSFET 인버터의 NEMA(National equipment manufacturer's association) 규격 만족을 위한 출력 필터 구조에 따른 영향을 분석한다. 구조와 목적에 따라 정현파 필터와 dv/dt 필터를 적용하여 380V, 60Hz, 3.7kW급 유도 전동기를 대상으로 실험을 수행하여 설계한 필터가 NEMA 규격을 만족시킬 수 있을 뿐만 아니라 전동기 누설전류를 감소시켜 효율까지 향상시킬 수 있음을 확인하였다.

  • PDF

Assessment of Factors affecting Rock-Slope Failure using Artificial Neural Network (인공신경망을 활용한 암반사면 붕괴유발인자 평가)

  • Song, Young-Karb;Park, Dug-Keun;Son, Young-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.759-763
    • /
    • 2010
  • Currently available evaluation checklists are developed for specific purposed using different parameters and items determined by different weighting factors. Those items with different weighting are sometimes said that they are based on the engineering judgement and leap of faith and, therefore, there is a limitation to adapt those checklists for slope-stability evaluation in the field. This study reviews factors affecting Rock-slope stability, analyze the relationship between those factors and slope failures using artificial neural network, and proposed a slope-stability evaluation model for adequate weighting for the factors.

  • PDF

Multi-Objective Optimal Design of a NEMA Design D Three-phase Induction Machine Utilizing Gaussian-MOPSO Algorithm

  • Zhang, Dianhai;Ren, Ziyan;Koh, Chang-Seop
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.184-189
    • /
    • 2014
  • This paper presents a multi-objective optimization approach to design rotor slot geometry of three-phase squirrel cage induction machine to achieve NEMA design D torque-speed (T-S) characteristics with high efficiency. The multi-objective Particle Swarm Optimization (MOPSO) algorithm combined with the adaptive response surface method and Latin hypercube sampling strategy is applied to obtain the Pareto optimal designs. In order to demonstrate the validity of the suggested optimal algorithm, an application to rotor slot design of three-phase induction motor is presented.

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.