• Title/Summary/Keyword: N-difference method

Search Result 1,350, Processing Time 0.026 seconds

Feasibility of a Nonlinear Acoustic Method for the Assessment of Bone Status and Osteoporosis in Trabecular Bone

  • Lee, Kang Il
    • Journal of the Korean Physical Society
    • /
    • v.73 no.12
    • /
    • pp.1849-1854
    • /
    • 2018
  • The present study aims to investigate the feasibility of using a simple nonlinear acoustic method for the assessment of bone status and osteoporosis in trabecular bone. Correlations of linear and nonlinear ultrasound parameters with the apparent bone density were obtained in 32 bovine femoral trabecular bone samples. Highly significant positive correlations were observed between the apparent bone density and the two linear ultrasound parameters, the speed of sound (SOS) and the normalized broadband ultrasound attenuation (nBUA), with Spearman's correlation coefficients of r = 0.85 and 0.77. In contrast, the apparent bone density was found to be negatively correlated with the nonlinear ultrasound parameter introduced in the present study, the logarithmic difference between the power spectrum levels of the fundamental frequency and the second harmonic (PSL1-PSL2), with the highest correlation coefficient of r = -0.92. These results suggest that the PSL1-PSL2, in addition to the SOS and the nBUA, may be useful for the assessment of bone status and osteoporosis.

The critical slab problem with the Anlı-Güngor scattering function

  • R.G. Tureci
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2864-2872
    • /
    • 2023
  • The criticality problem in this study is studied with the recently investigated the Anlı-Güngör scattering function. The scattering function depends on the Legendre polynomials as the Mika scattering function, but it includes only one scattering parameter, t, and its orders. Both Mika and Anlı-Güngör scattering are the same for only linear anisotropic scattering. The difference appears for the quadratic scattering and further. The analytical calculations are performed with the HN method, and the numerical results are calculated with Wolfram Mathematica. Interpolation technique in Mathematica is also used to approximate the isotropic scattering results when t parameter goes to zero. Thus, the calculated results could be compared with the literature data for isotropic scattering.

The design of phase error detector based on delayed n-tap rising edge clock:It's DP-PLL system application (지연된 n-탭 상승 에지 클럭을 이용한 위상 오차 검출기의 설계와 DP-PLL에의 적용)

  • 박군종;구광일;윤정현;윤대희;차일환
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.4
    • /
    • pp.1100-1112
    • /
    • 1998
  • In this paper, a novel method of minimizing the phase error is proposed. A DP-PLL system using this method is implemented and its performacnce is investigated, too. The DP-PLL system detects the phase error between reference clock and locally generated system clock. The phase difference is then reported as a PEV(Phase Error Variation), which is propoced from the delayted n-tap rising dege clock circuit with 5ns resolution in the phase detector. The algorithm is used to track the optimal DAC coefficients, which are adjusted from sample to sample in such a way as to minimize the PEV. The proposed method is found to have remarkable good potential for fast and accurate phase error tracking characteristic. The algorithm shows good performance to supress the low frequency jitter.-ending points, we design new basis functions based on the Legendre polynomial and then transform the error signals with them. When applied to synthetic images such as circles, ellipses and etc., the proposed method provides, in overall, outstanding results in respect to the transform coding gain compared with DCT and DST. And in the case when applied to natural images, the proposed method gives better image quality over DCT and comparable results with DST.

  • PDF

HYBRID DIFFERENCE SCHEMES FOR A SYSTEM OF SINGULARLY PERTURBED CONVECTION-DIFFUSION EQUATIONS

  • Priyadharshini, R.Mythili;Ramanujam, N.;Tamilselvan, A.
    • Journal of applied mathematics & informatics
    • /
    • v.27 no.5_6
    • /
    • pp.1001-1015
    • /
    • 2009
  • In this paper, two hybrid difference schemes on the Shishkin mesh are constructed for solving a weakly coupled system of two singularly perturbed convection-diffusion second order ordinary differential equations with a small parameter multiplying the highest derivative. We prove that the schemes are almost second order convergence in the supremum norm independent of the diffusion parameter. Error bounds for the numerical solution and its derivative are established. Numerical results are provided to illustrate the theoretical results.

  • PDF

Dentinal Tubules Occluding Effect Using Nonthermal Atmospheric Plasma

  • Lee, Chang Han;Kim, Young Min;Kim, Gyoo Cheon;Kim, Shin
    • International Journal of Oral Biology
    • /
    • v.43 no.2
    • /
    • pp.83-91
    • /
    • 2018
  • Nonthermal atmospheric plasma has been studied for its many biomedical effects, such as tooth bleaching, wound healing, and coagulation. In this study, the effects of dentinal tubules occlusion were investigated using fluoride-carboxymethyl cellulose (F-CMC) gel, nano-sized hydroxyapatite (n-HA), and nonthermal atmospheric plasma. Human dentin specimens were divided to 5 groups (group C, HA, HAF, HAP, and HAFP). Group HA was treated with n-HA, group HAF was treated with n-HA after a F-CMC gel application, group HAP was treated with n-HA after a plasma treatment and group HAFP was treated with n-HA after a plasma and F-CMC gel treatment. The occlusion of dentinal tubules was investigated using scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDS), which shows Ca/P ratio. In the EDS results, a higher Ca/P ratio was shown in the groups including n-HA than in the control group. The specimens of group HAP and HAFP had a higher Ca/P ratio in retentivity. In the SEM results, there was not a significant difference in the amount of times applied. Therefore, this study suggests F-CMC gel and n-HA treatment using nonthermal atmospheric plasma will be a new treatment method for decreasing hypersensitivity.

Effect of VC Addition on the Microstructure & Mechanical Properties of Ti(CN)-based Cermet (VC 첨가가 Ti(CN)계 써메트의 미세구조 및 기계적 성질에 미치는 영향)

  • 안성용;강신후
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.12
    • /
    • pp.1316-1322
    • /
    • 1998
  • The amount of VC and C/N ratio in Ti(CN) was varied to investigate the effect of VC addition on the mi-crostructural change in Ti(CN)-Ni system. As the amount of VC addition increases in Ti(C0.7N0.3)-20Ni sys-tem a complete solid solution was observed in Ti(C0.7N0.3)-20Ni-25VC system. It implies that the ratio of the dissolution rates of Ti(C0.7N0.3)to that of VC is nearly 2:1 at the sintering conditions used in this study. It was found from the experiments that the system composed of the Ti(C0.7N0.3) phase exhibits a rimless structure and relatively small amount of solid solution. That is among Ti(C0.7N0.3) phase exhibits a rimless structure and relatively small amount of solid solution. This is among Ti(C1-xNx) phases the dissolution rate of Ti(C0.3N0.7) is the lowest. Also fracture toughness(KIC) of the cermet was measured by indentation method. Attentions were paid to crack propagation path to look for a dominant fracture mode and to cor-relate it with fracture toughness values. The fracture toughness was relatively high with the addition of VC content. But the addition of a large VC content reduced the overall toughness of the cermet. This result is explained with the difference in fracture mode.

  • PDF

A First Principles Calculation of the Coherent Interface Energies between Group IV Transition Metal Nitrides and bcc Iron (IV족 천이금속 질화물과 bcc Fe간 계면 에너지의 제일원리 연구)

  • Chung, Soon-Hyo;Jung, Woo-Sang;Byun, Ji-Young
    • Korean Journal of Materials Research
    • /
    • v.16 no.8
    • /
    • pp.473-478
    • /
    • 2006
  • The coherent interface energies and misfit strain energies of Fe/XN (X=Ti, Zr, Hf) systems were calculated by first principles method. The interface energies in Fe/TiN, Fe/ZrN and Fe/HfN systems were 0.343, 0.114, and 0.030 $J/m^2$, respectively. Influence of bond energy was estimated using the discrete lattice plane/nearest neighbor broken bond(DLP/NNBB) model. It was found that the dependence of interface energy on the type of nitride was closely related to changes of the bond energies between Fe, X and N atoms before and after formation of the Fe/XN interfaces. The misfit strain energies in Fe/TiN, Fe/ZrN, and Fe/HfN systems were 0.239, 1.229, and 0.955 eV per 16 atoms(Fe; 8 atoms and XN; 8 atoms). More misfit strain energy was generated as the difference of lattice parameters between the bulk Fe and the bulk XNs increased.

Effect of Elastic-Band Exercise and Cognitive Rehabilitation in Cognition and Walking Speed of Elderly People -Pilot Study-

  • Yu, Seonghun;Lee, Youngsin;Kim, Seongsu
    • Journal of the Ergonomics Society of Korea
    • /
    • v.34 no.5
    • /
    • pp.363-375
    • /
    • 2015
  • Objective: This study aims to recognize the risk of current traffic systems and to investigate a method to decrease risk by doing exercise using an elastic-band and cognitive rehabilitation. Background: The existing traffic system usually focuses on the ordinary citizens, which may not be appropriate to the elderly. It may affect the cognition and walking speed of the elderly. This study tries to examine whether cognition and muscle training is appropriate to improve their vulnerability. Therefore this study will provide human ergonomics - based basic data in relation to the elderly to identify the risk of current signal system and to mitigate the risk. Method: A total of 30 elderly participants were divided into two groups: experimental and control groups. Experimental group (n=15) was trained to strengthen their muscles and to promote cognition, whereas control group (n=15) was not. The training was conducted twice a week for three weeks. To strengthen muscles, a yellow colored elastic-band was used, and a computer program for cognitive rehabilitation was used to develop cognition. In the experimental group, there were significant differences between pre and post exercises However, the control group didn't show any significant difference. The increase in cognition and walking speed was found in the experimental group, whereas there were no differences in the control group. Statistically there was no significant difference between the two groups. Results: The results of this study show that the exercise program using the elastic-band gave a positive effect on gait training thanks to the development of muscle power and balance. Conclusion: This study did not show any statistical difference or significant differences between the two groups, since time was restricted, we believe. Application: The results of the walking speed will help to prevent traffic collision.

The Comparison of Effect of Sports Massage, Kaltenborn-Evjenth Orthopedic Manipulative Therapy and Electrical Therapy, General Exercise Therapy in ROM Increase and Pain Reduction in Patients with Frozen Shoulder (동결견 환자의 관절가동범위 회복과 통증 감소에 있어서 스포츠 마사지 및 Kaltenborn-Evjenth정형도수치료와 전기치료 및 일반 운동치료의 효과 비교)

  • Nam, Hyoung-Chun;Woo, Kwang-Seog
    • Journal of Korean Physical Therapy Science
    • /
    • v.10 no.2
    • /
    • pp.73-85
    • /
    • 2003
  • The purpose of the present study was to the investigate the effect of sports massage, kaltenborn-evjenth orthopedic manipulative therapy and electrical therapy, general exercise on the limitation of range of motion(ROM) and on the pain(VAS) in patients with frozen shoulder. Fiftheen frozen shoulder patients between 50 and 60 years of age(females) were selected and were divided equally by random distribution into A group(sports massage, kaltenborn-evjenth orthopedic manipulative therapy, N=7)and B(electrical therapy, general exercise therapy, N=7) group. The results obtained were as follows : 1) The range of motion between two groups are significantly different in the treatment times, the ROM of A group increase in after-treatment(2 week 4 week) in comparison with ROM in before-treatment, it is significant increase. And it is significant difference in B group. 2) The pain level between two groups are not significantly different in the treatment times, the pain level of A group decrease in after-treatment(2 week, 4 week) in comparison with before-treatment, it is significant decrease. And it is significant difference in B group. Although the pain level of the A group decrease in after 2 week treatment in comparison with before-treatment but it is not significant decrease. Although the pain level of the B group decrease in after 4 week treatment in comparison with after 2 week treatment, but it is not significant decrease. 3) The A group is more effective in increasing the ROM and decreasing the pain level than B group during treatment times. The results showed that both A group method and B group method are effective ROM increase and pain reduce, but A group method is superior to B group method in ROM increase and pain reduce.

  • PDF

Driveline Infections Incidence According to Dressing Methods for Patients with Left Ventricular Assist Device Implantation (좌심실보조장치 수술 환자의 드레싱 방법에 따른 드라이브라인 감염 실태)

  • Choi, Nam Gyung;Choi, Su Jung;Choi, Ji Yeon;Park, Sun Hee
    • Journal of Korean Clinical Nursing Research
    • /
    • v.28 no.2
    • /
    • pp.167-176
    • /
    • 2022
  • Purpose: Driveline infection (DLI) is one of the major adverse events of Left Ventricular Assist Device (LVAD). The purpose of this study was to explore the incidence of DLI according to the driveline dressing methods. Methods: This study was a retrospective cohort study that investigated the medical records of 75 patients who implanted LVAD from January 2015 to December 2020 at a hospital in Seoul, Korea. Traditionally, sandwich dressing method was applied until October 2019, after which newly winded dressing method was adopted for driveline dressing to LVAD patients. The outcome variables were compared between sandwich dressing method applied group (n=41) and winded dressing method applied group (n=34). The follow-up period for DLI was 1 year. Results: When compared participants' characteristics, there was no difference between the two groups, except the type of LVAD device. The incidence of DLI was 17.1% in sandwich dressing group, while no infection was found in winded dressing group (p=.011). Conclusion: Although there were difference in the LVAD devices, it is considered that winded dressing contributed to the reduction of DLI. Further research on standardized dressing methods was required for DLI prevention in Korea.