• Title/Summary/Keyword: Mutual Coupling

Search Result 193, Processing Time 0.031 seconds

Compensation of Radiation Pattern Distortion by Mutual Coupling in the Array Antenna Using the Particle Swarm Optimization Algorithm (입자군집 최적화 알고리즘을 이용한 배열안테나의 상호결합에 의한 방사패턴 왜곡보상)

  • Kim, Jae Hee;Ahn, Chi-Hyung;Chun, Joong-Chang
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.5
    • /
    • pp.458-464
    • /
    • 2016
  • This paper proposes the compensation method which decreases the radiation pattern distortion caused by the mutual coupling in an array antenna. If the element distance of an array antenna decreases, the radiation pattern could be distorted by the strong mutual coupling, which changes the magnitude and phase of input signals and causes an unwanted radiation pattern. To remove the pattern distortion, compensated input signals are inserted in an array antenna. The magnitude and phase of input signals are determined by Particle Swarm Optimization (PSO) algorithm. A $4{\times}1$ dipole array antenna with omnidirectional elements is used to confirm the validity of the algorithm, where each element is placed in 0.2 wavelength to evoke the strong coupling. After input signals are optimized by PSO, it is found that the compensated radiation results in the same as the ideal case.

Analysis of error factors of the Fall-of-potential test method in measurements of grounding impedance (전위강하법에 의한 접지임피던스 측정 시 오차요인 분석)

  • Jeon, Byung-Wook;Lee, Su-Bong;Jung, Dong-Cheol;Lee, Bok-Hee;Ahn, Chang-Hwan
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.313-316
    • /
    • 2008
  • This paper presents the error factors of Fall-of-potential test method used in measurements of the grounding-system impedance. This test methods inherently can introduce two possible errors in the measurements of grounding-system impedance: (1) ground mutual resistance due to current flow through ground from the ground electrode to the current probe, (2) ac mutual coupling between the current test lead and the potential test lead. The errors of ground mutual resistances and ac mutual coupling are expressed by the equation in calculating grounding impedance. These equations were calculated by Matlab that is commercial tool using mathematical calculation. The results of calculation were applied to correct grounding impedance.

  • PDF

H-Plane Coupling Between Rectangular Microstrip antennas (구형 마이크로스트립 안테나의 H-Plane 상호결합)

  • Ko, Ji-Whan;Cho, Young-Ki;Son, Hyon
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.6
    • /
    • pp.46-52
    • /
    • 1985
  • A theoretical study of mutual coupling effects between two H-plane coupled microstrip patch antennas is presented. The radiation resistance and slot capacitance of a single micro-strip patch are calculated. To investigate the mutual coupling effects, the even and odd mode characteristic impedance and effective dielectric constants are obtained using the coupled microstrip line model. The S-parameter matrix elements 511,512 are used to study the mutual coupling e(facts in S-band frequency ranges for various patch spacings. Theoretical results and measurements are in good agreement.

  • PDF

Inductive Coupling Analysis of Ground Impedance on Parallel Orientation of Current and Potential Conductors (전류 및 전위 측정선의 평행배치에서 접지임피던스 상호유도 분석)

  • Cho, Sung-Chul;Eom, Ju-Hong;Lee, Tae-Hyung
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1470-1471
    • /
    • 2007
  • The mutual coupling between the current and potential measuring wires makes serious effect on the measurement of the ground impedance. For analyzing the effect of mutual coupling, we compared the ground impedance measured on site with the ground impedance calculated with MATLAB. When the parallel length is 10 [m], the measured ground impedance is similar with the calculated ground impedance. As the parallel length is extended over 10 [m], the error between measured ground impedance and calculated ground impedance is also increased on a large scale. We analyzed the mutual coupling by the frequency and present the inaccuracy of ground impedance quantitatively.

  • PDF

A New Online Calibration Algorithm for Array Antenna using Independent Component Analysis

  • Suk, Mi-Kyung;Lee, Jong-Hyun;Chun, Joo-Hwan;Park, Jin-Kyu;Kim, Yong-Hwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1568-1572
    • /
    • 2004
  • This paper proposes a new online calibration algorithm for the array antenna system. As you know, the several previous calibration methods for the mutual coupling did not estimate but measure mutual coupling effect at the real or test-bed system directly. Therefore we suggest some idea to compensate the calibration errors due to mutual coupling effect and mismatch in cables and electronic modules without the off-line calibration. In this work, we can calibrate the array antenna system under the operation of the system using Independent Component Analysis(ICA). This is what is called an online calibration. As you know, the ICA method has permutation and scaling problems. However, we solve problems of the ICA method and apply it to the calibration of an array antenna. The method simultaneously estimates the DOA(Direction of Arrival) of the signals, and calibrates the array for that specific angle. The proposed algorithm is evaluated by computer simulation and its behavior is illustrated by a numerical example.

  • PDF

A New Distance Relaying Algorithm Immune to Mutual Coupling Effect and Reactance Effect for 765kV Untransposed Parallel Transmission Lines (상호결합효과와 리액턴스효과를 제거한 765kV 비연가 송전선로 보호용 거리계전 알고리즘)

  • Ahn Yong-Jin;Kang Sang-Hee
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.1
    • /
    • pp.25-30
    • /
    • 2005
  • An accurate digital distance relaying algorithm which is immune to mutual coupling effect and reactance effect of the fault resistance and the load current for the line faults in 765kV untransposed transmission lines is proposed. The algorithm can estimate adaptively the impedance to a fault point independent of the fault resistance. To compensate the magnitude and phase of the apparent impedance, this algorithm uses the angle of an impedance deviation vector. The impedance correction algorithm for phase-to-ground fault and phase-to-phase short fault use a voltage equation at fault point to compensate the fault current at fault point. A series of tests using EMTP output data in a 765kV untransposed transmission lines have proved the accuracy and effectiveness of the proposed algorithm.

A Distance Relaying Algorithms Immune to Reactance Effect for Double-Circuit Transmission Line Systems (리액턴스 효과를 최소한 병행 2회선 송전선로 보호 거리계전 알고리즘)

  • 안용진;강상희;이승재
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.1
    • /
    • pp.38-44
    • /
    • 2001
  • For double-circuit transmission line systems, an accurate digital distance relaying algorithm immune to the reactance effect is proposed. The apparent impedance calculated by the distance relay is influenced by the combined reactance effect of the fault resistance and the load current as well as the mutual coupling effect caused by the zero-sequence current of the adjacent parallel circuit. To compensate the magnitude and phase of the estimated impedance, this algorithm uses phase angle difference between the zero(positive) sequence of the both side of the system seperated by the fault point. The impedance measuring algorithm presented used a current distribution factor to compensate mutual coupling effect instead of the collected zero-sequence current of the adjacent parallel circuit.

  • PDF

Improved analysis method for the mutual coupling in the rectangular microstrip antenna geometry and its application to bandwidth broadening techniques (구형 마이크로스트립 안테나 구조의 상호 결합에 대한 개선된 해석방법과 제안된 해석방법의 광대역 기술에의 응용)

  • 조영기;이창원;이종익;윤리호;채규수;홍재표
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.1
    • /
    • pp.61-69
    • /
    • 1995
  • a numerical method to the problem of mutual admittance between two slots is considered by use of conservation of complex power. Calculation of mutual admittance is compared with other results. And mutual admittance obtained by the method is used in the analysis for the broadband rectangular microstrip antenna geometry using E0plane gap coupling. The theoretical results for both return loss and radiation pattern of the broadband antenna are compared with experimental results. Good agreement between calculated and measured values has been observed.

  • PDF

Impedance and Mutual Coupling Characteristics of a Probe-Fed Stacked Circular Microstrip Two-Element Array Antenna (Probe로 급전되는 적층형 원형 마이크로스트립 2소자 배열 안테나의 임피던스 및 상호 결합 특성)

  • 이면주;남상욱
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.11
    • /
    • pp.1767-1773
    • /
    • 1993
  • In this paper, the coupling characteristics as well as the self and the mutual Impedance of a two-element probe-fed stacked circular microstrip array antennas are presented. A full wave analysis for the structure is performed In the spectral domain using the vector Hankel transform(VHT). Also, we presented measured results for the impedance, the coupling characteristics of the antenna and the variation of the coupling with the distance between the two elements. Finally, the calculated and measured results are shown to agree well wlth each other through comparisons.

  • PDF

Effect of Mutual Coupling Between Test Leads on Ground Impedance Measurement (측정선의 상호유도작용이 접지임피던스의 측정에 미치는 영향)

  • Lee, Bok-Hee;Eom, Ju-Hong;Cho, Sung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.71-74
    • /
    • 2003
  • Fall-of-potential method is used usually to measure the ground impedance of large scale grounding system exactly. Because the interlinked magnetic flux between closed loops to inject test current and to measure potential rise is existed in E-P-C straight line arrangement, mutual(or inductive) coupling influences greatly on the measurement correctness. Measurement errors produced from inductive coupling could be reduced by the arrangement methods of auxiliary electrodes. Right angle or P-E-C order arrangement methods were effective to reduce the inductive coupling and the decrease degree of measurement error was analysed as quantitative through an experiment.

  • PDF