• 제목/요약/키워드: Municipal wastewater treatment plant

검색결과 98건 처리시간 0.025초

Entrapped Mixed Microbial Cell (EMMC) 공정을 이용한 수산물 가공 폐수처리에서 유기물 및 질소 동시제거 (Simultaneous Removal of Organic and Nitrogen in the Treatment of Fish Processing Wastewater using Entrapped Mixed Microbial Cell (EMMC) Process)

  • 정병철;박권삼;정병곤
    • 한국물환경학회지
    • /
    • 제22권3호
    • /
    • pp.492-497
    • /
    • 2006
  • Feasibility of simultaneous removal of organic materials and nitrogen in the wastewater from fisheries processing plant was evaluated using entrapped mixed microbial cell (EMMC) process. The experiment was performed using activated sludge from municipal sewage treatment plant which was immobilized with gel matrix by cellulose triacetate. It was found the stable operation at the treatment system which is composed of anoxic and oxic tank, was possible when the organic and nitrogen loading rates were increased stepwise. The organic and nitrogen loading rates were conducted from 0.65 to $1.72kgCOD/m^3/d$ and from 0.119 to $0.317kg\;T-N/m^3/d$ with four steps, respectively. The maximum nitrogen loading rate which could satisfy the regulated effluent standard of nitrogen concentration, was $0.3kg\;T-N/m^3/d$. The removal efficiency of total nitrogen was decreased apparently as increasing nitrogen loading rates, whereas the removal efficiency of ammonium nitrogen was effective at the all tested nitrogen loading rates. Therefore, it was concluded that nitrification was efficient at the system. Nitrate was removed efficiently at the anoxic tank. whereas the nitrification efficiency at the oxic tank ranged 94.0% to 96.9% at the tested loading rates. The removal efficiencies of chemical oxygen demand (COD) and those of total nitrogen at the entire system ranged from 94.2% to 96.6% and 73.4% to 83.4%, respectively.

다양한 하수를 대상으로 아질산화 반응 적용성 평가 (Applicability Evaluation of Nitritation with Various Wastewater)

  • 임지열;길경익
    • 한국습지학회지
    • /
    • 제17권1호
    • /
    • pp.11-18
    • /
    • 2015
  • 질소에 의한 수질 오염의 심각성이 부각되면서 하 폐수 내 질소제거를 위한 연구가 수행되고 있다. 특히 아질산화 반응을 기반으로 하는 경제적이며 친환경적인 장점을 지닌 혁신적인 질소 제거 공법에 관한 연구가 주목받고 있다. 하지만 아질산화 반응을 기반으로 하는 공법의 현장 적용성 및 효율화 방안에 관한 연구는 완전히 이루어지고 있지 않은 실정이다. 본 연구에서는 하수처리장 유입 하수, 최초 침전지 상등액, 반류수 그리고 가축분뇨의 특성분석 및 실험실 규모 반응조를 운전하였다. 반류수 및 가축분뇨의 경우 다른 하수에 비해 고농도의 질소를 함유한 것으로 나타나 수처리 계통 질소 부하를 증가시키는 것으로 나타났다. 반응조 운전 결과 낮은 암모니아성 질소의 농도로 인해 유입 하수와 최초 침전지 상등액의 경우에는 아질산화 반응이 유도되지 않음을 확인하였다. 또한 하수 종류 별로 아질산화 반응이 유도되는 체류시간 조건이 차이를 보였는데 이는 유기물 및 암모니아성 질소 농도에 의한 것으로 판단된다. 아질산화 반응이 유도된 하수 중 혐기 소화 상등액이 가장 높은 효율을 보이는 것으로 나타났다.

바이오산업폐수처리수의 재이용을 위한 hybrid 인공습지 시스템의 적용가능성 연구 (Application of the Hybrid Constructed Wetland for a Reuse of the Effluent from Bio-industrial Wastewater Treatment Plant)

  • 신재석;김성철;조광주;최충호;최인욱;박정자;박구현
    • 한국습지학회지
    • /
    • 제11권1호
    • /
    • pp.115-121
    • /
    • 2009
  • 생물산업 연구단지에서 발생되는 폐수를 처리하기 위해 건설된 폐수처리장의 3차 처리시설로 hybrid 인 공습지 시스템을 적용하여 최종 방류수의 재이용가능성을 평가하였다. 폐수처리를 위한 1차 처리공정은 화학적 처리(약품 응집)이며, 2차 처리공정은 생물학적 처리(표준활성슬러지법)로 구성되어 있다. 3차 처리시설로서 hybrid 인공습지는 자연통풍시스템이 구비된 호기성 인공습지와 혐기/무산소성 인공습지가 순차적으로 연결된 시스템이다. Hybrid 인공습지로 유입되는 2차 생물학적 처리공정의 처리수 농도는 BOD, SS, T-N 및 T-P의 평균 농도가 각각 53mg/L, 48mg/L, 34mg/L 및 3mg/L로 나타났으며, hybrid 인공습지에서의 최종방류수의 BOD, SS, T-N 및 T-P의 평균농도는 각각 2.3mg/L, 1.2mg/L, 7.95mg/L 및 0.83mg/L로 나타나 하수처리수의 재이용권고수질기준과 비교할 때 조경용수나 세척용수 등의 용도로 직접 재이용이 가능한 수질이 확보될 수 있었다. Hybrid 인공습지는 반응조를 호기 및 혐기/무산소 조건으로 기능화 함으로서 높은 효율로 오염물질이 제거될 수 있었으며, 이러한 결과로부터 다양한 하수 및 폐수의 3차 처리시설로서 활용이 가능한 것으로 평가되었다.

  • PDF

생활폐기물 소각시 요구되는 요소수의 대체물질로 음식물 폐수 속의 암모니아 적용에 관한 연구 (A Study on Investigate the Suitability of ${NH_4}^+$ Applications of Food Waste Water Instead of Urea in the Incineration of Municipal Solid Waste)

  • 고성규;조용균;이영신
    • 유기물자원화
    • /
    • 제20권4호
    • /
    • pp.97-105
    • /
    • 2012
  • 본 연구는 음식물류 폐기물의 처리과정에서 발생하는 음식물류 폐수를 생활폐기물 소각시설에서 생활폐기물과 음식물류폐수를 혼합하여 소각처리 방법과 소각시 음식물류 폐수를 이용한 질소산화물 제거 및 배출가스의 영향등을 조사하였다. 해양투기용으로 발생된 음식물류폐기물 폐수는 성상이 94-96%의 함수율을 갖고 있다. 음식물류폐기물 폐수를 주입하였을 때 소각로 출구 온도는 $897^{\circ}C$이였으며, 평상시는 $925^{\circ}C$로 약 $28^{\circ}C$도 떨어졌다. 음식물류폐기물 폐수를 각각 $200{\ell}/hr$, $300{\ell}/hr$ 투입시 질소산화물의 평균배출농도는 각각 50ppm, 46ppm 이었다. 연관식 폐열보일러는 음식물류 폐수의 투입량이 많을수록 튜브 막힘 현상이 있었으며, 막힘 튜브는 압축공기를 이용한 튜브 청소로 원상태를 유지 할 수 있어 연속적 소각에는 방해가 되지 않았다. 유기성 폐기물인 음식물류 폐수의 자원화 처리방법과 더불어 기존 소각시설을 이용한 소각처리가 육상처리의 한 방법으로 자리매김 할 수 있으며, 소각시 배출가스의 질소산화물이 제거됨으로써 질소산화물 제거용 암모니아, 요소수 등 화학약품비용 절감하는 효과도 있는 것으로 나타났다.

한발기 벼 재배시 하수종말처리장 방류수 관개에 따른 논의 수질 및 벼 생육에 미치는 영향 (Effects on Water Quality and Rice Growth to Irrigation of Discharge Water from Municipal Waste Treatment Plant in Rice Paddy during Drought Periods)

  • 신중두;이종식;김원일;정구복;김진호;윤순강;최철만
    • 한국환경농학회지
    • /
    • 제27권3호
    • /
    • pp.225-230
    • /
    • 2008
  • 하수종말처리장 방류수를 이용한 포장적응시험에서 토양 검정시비량의 50%시비수준에서 대체용수원 20일 관개구의 벼 생육 및 수량은 비교적 대조구와 비슷하게 나타났다. 표면수의 수질에 대한 $EC_i$ 및 SAR값은 하수종말처리장 방류수 관개구가 지하수 관개구에 비해 2배 이상 높은 것으로 나타났다. 관개기간별 하수종말처리장 방류수 10일과 20일 관개구의 표면수 $EC_i$ 및 SAR값은 유의차가 없었지만, 생육초기 단계에서 30일간 관개구에서 가장 높게 나타났다. 그리고 침출수중의 $EC_i$ 및 SAR값은 비료시용 수준별 및 대체용수 관개기간에 따라 일정한 경향을 보이지 않았다. 결론적으로 이앙기의 한발기 20일 동안은 검정시비량의 50% 시비수준으로 하수종말처리 방류수를 관개할 수 있는 것으로 판단된다. 그리고 한발 20일 동안 대체용수 관개 이용 효율성은 벼 재배기간 동안 총 관개량에 비교하여 32.7%인 것으로 나타났다.

인공 신경망(ANN)에 의한 하수처리장의 유입 유량 및 유입 성분 농도의 예측 (Prediction of Influent Flow Rate and Influent Components using Artificial Neural Network (ANN))

  • 문태섭;최재훈;김성희;차재환;염훈식;김창원
    • 한국물환경학회지
    • /
    • 제24권1호
    • /
    • pp.91-98
    • /
    • 2008
  • This work was performed to develop a model possible to predict the influent flow and influent components, which are one of main disturbances causing process problems at the operation of municipal wastewater treatment plant. In this study, artificial neural network (ANN) was used in order to develop a model that was able to predict the influent flow, $COD_{Mn}$, SS, TN 1 day-ahead, 2day-ahead and 3 day ahead. Multi-layer feed-forward back-propagation network was chosen as neural network type, and tanh-sigmoid function was used as activation function to transport signal at the neural network. And Levenberg-Marquart (LM) algorithm was used as learning algorithm to train neural network. Among 420 data sets except missing data, which were collected between 2005 and 2006 at field plant, 210 data sets were used for training, and other 210 data sets were used for validation. As result of it, ANN model for predicting the influent flow and components 1-3day ahead could be developed successfully. It is expected that this developed model can be practically used as follows: Detecting the fault related to effluent concentration that can be happened in the future by combining with other models to predict process performance in advance, and minimization of the process fault through the establishment of various control strategies based on the detection result.

Nitrate Removal by Pseudomonas fluorescens K4 Isolated from a Municipal Sewage Treatment Plant

  • Lee, O-Mi;Oh, Jong-Hyeok;Hwang, Doo-Seong;Choi, Yun-Dong;Chung, Un-Soo;Park, Jin-Ho;Kim, Min-Ju;Jeong, Seong-Yun;Lee, Sang-Joon
    • 한국환경과학회지
    • /
    • 제16권11호
    • /
    • pp.1219-1223
    • /
    • 2007
  • The removal of nitrogen compounds from a wastewater is essential and it is often accomplished by bio-logical process. An aerobic nitrate-removing bacterium was isolated from a municipal sewage treatment plant and soil. On the basis of its morphological, cultural and physiological characteristics and 16S rRNA sequencing data, this strain was identified as Pseudomonas fluorescens, and named as P. fluorescens K4. The optimal conditions of the initial pH and temperature of media for its growth were $7.0{\sim}8.0$ and $30^{\circ}C$, respectively. P. fluorescens K4 was able to remove 99.9% of nitrate after 24 h in a culture. The strain could grow with a nitrate concentration up to 800 mg/l and was able to remove 99.9% of nitrate after 104 h of incubation. The optimal electron donor was sodium citrate for a nitrate removal. The strain K4 showed a capability of a complete nitrate removal when the initial C/N ratio was 1.0. An effect of the initial seed concentration was observed for a cell of 10% (v/v) for a nitrate removal. Especially P. fluorescens K4 could completely remove 200 mg/l ammonium for 3 days.

하수의 최종 유출수 수질 개선을 위한 침전조 모형실험에 적용한 끈상 미생물접촉재와 미나리의 고도처리효율에 관한 연구 (Advanced Treatment Efficiency of Biological String Media and Oenanthe javanica for Effluent Quality Improvement in the Sedimentation Model Plant)

  • 배준삼;이상호
    • 한국산학기술학회논문지
    • /
    • 제7권3호
    • /
    • pp.440-447
    • /
    • 2006
  • 본 연구의 목적은 미나리와 끈상 미생물접촉재를 이용하여 생활하수의 하수처리장 방류수의 수질 개선을 위함이다. 최종 방류수의 수질을 개선하기 위한 침전조 모형 플랜트를 2개 제작하여 실험하였는데, 하나(Tank 1)는 기존 하수처리장 침전조와 같게 제작 하였으며, 다른 하나의 침전조(Tank 2)는 침전조의 수초섬 상부에는 미나리를 식재하고 하부에는 끈상 미생물 접촉재를 배치하였다. 유기 오염물질인 BOD, 부유고형물질인 SS, 질소 그리고 인에 대한 고도처리 효율을 검증하였다. 실험 결과 Tank 2에서 유출되는 배출수가 Tank 1에서 배출되는 유출수보다 처리 효율이 향상되었다. 처리 효율을 살펴보면, Tank 1보다 Tank 2 유출수의 BOD는 $7.9%{\sim}38.8%$가 향상되었으며, 부유고형 물질인 SS는 $14.3%{\sim}60.0%$ 향상되었다. 부영양화 물질인 T-N은 $9.6%{\sim}31.5%$ 향상되었으며, T-P는 $33.0%{\sim}80.0%$까지 향상되었다. 처리 효율로 판단하면 T-P와 SS 제거효율이 BOD와 T-N보다 높았다.

  • PDF

Growth regime and environmental remediation of microalgae

  • Hammed, Ademola Monsur;Prajapati, Sanjeev Kumar;Simsek, Senay;Simsek, Halis
    • ALGAE
    • /
    • 제31권3호
    • /
    • pp.189-204
    • /
    • 2016
  • Microalgal bioremediation of CO2, nutrients, endocrine disruptors, hydrocarbons, pesticides, and cyanide compounds have evaluated comprehensively. Microalgal mitigation of nutrients originated from municipal wastewaters, surface waters, and livestock wastewaters has shown great applicability. Algal utilization on secondary and tertiary treatment processes might provide unique and elegant solution on the removing of substances originated from various sources. Microalgae have displayed 3 growth regimes (autotrophic, heterotrophic, and mixotrophic) through which different organic and inorganic substances are being utilized for growth and production of different metabolites. There are still some technology challenges requiring innovative solutions. Strain selection investigation should be directed towards identification of algal that are extremophiles. Understanding and manipulation of metabolic pathways of algae will possible unfold solution to utilization of algae for mitigation of dissolve organic nitrogen in wastewaters.

FC/FS 비율에 의한 분변오염원의 출처파악의 유효성 (Validity of Fecal Pollution Source Tracking using FC/FS Ratio)

  • 박지은;이영옥
    • 한국물환경학회지
    • /
    • 제26권1호
    • /
    • pp.28-34
    • /
    • 2010
  • This study was conducted to assess the validity of fecal coliforms to fecal streptococci ratio (FC/FS) for distinguishing the human from animal origin of fecal pollution in surface water. FC/FS ratio determined in effluent from municipal wastewater and human feces treatment plant (WWTP) and in downstream close to discharge of human feces was above 4 which indicates human origin. However FC/FS ratios determined seasonally in other water zones of the Nakdong River, even in the same sampling site, varied differently (above 4 or less than 0.7) due to different survival time of FC and FS and other environmental factors such as rainfall in watershed. Compared to other season, FC/FS ratios in winter were much lower regardless of the origin. It is concluded that the FC/FS ratio determined in surface water is not always valid for determining the origin of fecal pollution.