• 제목/요약/키워드: Multiple projection images

검색결과 44건 처리시간 0.024초

Three Dimensional Target Volume Reconstruction from Multiple Projection Images

  • Cheong, Kwang-Ho;Suh, Tae-Suk;Lee, Hyoung-Koo;Choe, Bo-Young
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.439-441
    • /
    • 2002
  • The aim of this study is to reconstruct the 3D target volume from multiple projection images. It was assumed that we were already aware of the target position exactly, and all processes were performed in Target Coordinates whose origin was the center of the target. We used six projections: two projections were used to make a Reconstruction Box and four projections were for image acquisition. Reconstruction Box was made up of voxels of 3D matrix. Projection images were transformed into 3D volume in this virtual box using geometrical based back-projection method. Algorithm was applied to an ellipsoid model and horse-shoe shaped model. Projection images were created using C program language by geometrical method and reconstruction was also accomplished using C program language and Matlab(The Mathwork Inc., USA). For ellipsoid model, reconstructed volume was slightly overestimated but target shape and position was proved to be correct. For horse-shoe shaped model, reconstructed volume was somewhat different from original target model but there was a considerable improvement in target volume determination.

  • PDF

다중투사영상을 이용한 표적체적의 3차원 재구성 (Three Dimensional Target Volume Reconstruction from Multiple Projection Images)

  • 정광호;진호상;이형구;최보영;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제14권3호
    • /
    • pp.167-174
    • /
    • 2003
  • 정위적방사선수술과 같은 경우 치료계획 수립 시 병변의 정확한 위치뿐만 아니라 정확한 부피와 모양을 아는 것도 매우 중요하다. 병변의 확인을 위해서 때로는 혈관조영영상이 이용되기도 하는데 동정맥 기형과 같은 경우 이 방법이 병변의 구별을 위하여 가장 좋은 방법이기 때문이다. 병변의 정확한 위치는 두개의 투사영상으로부터 얻을 수 있지만 두 개의 투사영상 만으로는 병변을 3차원적으로 재구성하는 것은 불가능하다고 여겨지고 있다. 본 연구의 목적은 다수의 투사 영상들을 이용하여 병변을 3차원적으로 재구성하는 것이다. 이때 병변의 위치는 기존에 제안된 방법에 의하여 이미 알고 있다고 가정하였으며 모든 과정은 병변의 중심을 원점으로 하는 표적좌표계에서 수행되었다. 본 연구에서는 6개의 투사영상이 이용되었는데 정면과 측면 투사영상은 체적소(voxel)로 구성된 재구성상자를 구하기 위하여 이용되었으며 나머지 네 개의 투사영상은 역투사 방법(back-projection method)에 의하여 재구성 상자(Reconstruction Box) 내에서 3차원적으로 재구성하는데 이용되었다. 이 방법의 정확도와 해상도는 병변의 크기와 모양에 따라 달라질 수 있다. 본 연구에서 제안된 알고리듬의 검증을 위하여 C 언어와 Matlab을 이용하여 타원체 모델과 말굽형 모델에 대하여 투사영상을 얻고 그 영상을 이용하여 재구성해보았다. 타원체모델의 경우에는 원래의 모델보다 약간 크게 재구성되었지만 모양과 방향, 위치가 정확함을 확인할 수 있었다. 말굽형 모델은 재구성된 모양이 원래의 모양과 차이가 많이 났지만 기존 방법에 비하여 실제 모양에 근접하게 재구성할 수 있었으므로 병변을 확인하는 경우에는 도움이 될 것으로 사료된다.

  • PDF

MC 시뮬레이션을 이용한 Aft-Multiple-Silt 시스템의 산란선 제거 효과 평가 (Evaluation of Scatter Reduction Effect of the Aft-Multiple-Slit (AMS) System Using MC Simulation)

  • 장지나;서태석;장도윤;장홍석;김시용
    • Radiation Oncology Journal
    • /
    • 제28권4호
    • /
    • pp.224-230
    • /
    • 2010
  • 목적: 본 연구에서는 콘빔 CT에서 산란선 제거를 위한 aft-multple-slit (AMS) 시스템을 설계하였다. 예비 연구로서 본 시스템의 효용성을 검증하기 위해 MC 시뮬레이션을 수행하였다. 대상 및 방법: 가상 시뮬레이션은 산란선과 산란선+일차선을 계산할 수 있는 MCNPX의 radiography tally 5를 이용하였다. AMS는 빔의 발산성을 고려한 각이 동일한 아크 형태이고, 길이 방향에서의 산란선을 막는다. AMS의 효용성을 위한 평가는 AMS를 사용하지 않았을 때의 일차선과 산란선을 비교함으로써 수행되었다. 2D projection 영상을 얻기 위해 전체의 AMS는 한번의 캔트리 회전 후 AMS에 의해 가려진 부분의 영상 획득을 위해 다시 한 번 회전하는 구조이다. 결과: 일차선의 2D projection 영상은 모든 AMS의 폭에서 그리고 AMS를 사용하지 않았을 때에도 동일하였으나 일차선+산란선의 2D projection 영상은 slit의 폭에 따라 결과가 변했다. Slit의 폭을 5 mm, 10 mm, 15 mm, 20 mm로 하였을 때 평균 산란성 제거율은 29%, 15%, 9%, 8%였다. 결론: 본 연구에서는 AMS를 이용한 콘빔 CT의 산란선 제거 효과를 평가하였다. MC 시뮬레이션을 이용한 본 시스템의 사전 연구에서는 상당한 산란선 제거 효과를 보여주었다.

다중 2D 영상을 이용한 3D 인체 계측 시스템 (A System for Measuring 3D Human Bodies Using the Multiple 2D Images)

  • 김창우;최창석;김효숙;강인애;전준현
    • 복식
    • /
    • 제53권5호
    • /
    • pp.1-12
    • /
    • 2003
  • This paper proposes a system for measuring the 3D human bodies using the multiple 2D images. The system establishes the multiple image input circumstance from the digital camera for image measurement. The algorithm considering perspective projection leads us to estimate the 3D human bodies from the multiple 2D images such as frontal. side and rear views. The results of the image measurement is compared those of the direct measurement and the 3D scanner for the total 40 items (12 heights, 15 widths and 13 depths). Three persons measure the 40 items using the three measurement methods. In comparison of the results obtained among the measurement methods and the persons, the results between the image measurement and the 3D scanner are very similar. However, the errors for the direct measurement are relatively larger than those between the image measurement and the 3D scanner. For example, the maximum errors between the image measurement and the 3D scanner are 0.41cm in height, 0.39cm in width and 0.95cm in depth. The errors are acceptable in body measurement. Performance of the image measurement is superior to the direct. because the algorithm estimates the 3D positions using the perspective projection. In above comparison, the image measurement is expected as a new method for measuring the 3D body, since it has the various advantages of the direct measurement and 3D scanner in performance for measurement as well as in the devices, cost, Portability and man power.

위상이동 간섭무늬 투영을 이용한 3차원 형상측정 시스템의 위상계산오차 해석 (Phase calcuation error analysis of 3D shape measurement system using phase-shifted fringe projection method)

  • 류현미;김석성;홍석경;연규황
    • 한국광학회지
    • /
    • 제13권3호
    • /
    • pp.182-188
    • /
    • 2002
  • 위상이동 간섭무늬 투영 방법을 이용한 3차원 형상측정 시스템의 위상계산오차를 분석하였다. 본 연구에서 다룬 오차의 요소에는 물체 표면의 특성에 따라 검출기에 나타나는 양자화 크기의 변이 효과, 물체 표면에 맺히는 간섭무늬 패턴의 초점 어긋남 효과, 간섭무늬의 위상이동 오차에 의한 효과, 위상 이동된 간섭무늬 패턴이 투영된 여러 개의 물체 상을 받아들이는 도중에 시스템 및 주위 환경 변화에 의한 오차, 그리고 투영되는 격자 패턴의 왜곡에 의한 효과들을 계산하고 논의하였다.

Projection-Type Integral Imaging Using a Pico-projector

  • Yang, Yucheol;Min, Sung-Wook
    • Journal of the Optical Society of Korea
    • /
    • 제18권6호
    • /
    • pp.714-719
    • /
    • 2014
  • A pico-projector is a compact and mobile projector that has an infinite focus. We apply the pico-projector to a projection-type integral imaging system, which can expand the image depth to form multiple central depth planes. In a projection-type integral imaging system, the image flipping problem arises because the expanded elemental images pass through a lens array. To solve this problem, we propose the ray tracing of a pico-projector at a central depth plane and compensate the elemental image using a pixel-mapping process. Experiments to verify the proposed method are performed, and the results are presented.

Optimizing cone-beam computed tomography exposure for an effective radiation dose and image quality balance

  • Ananda Amaral Santos;Brunno Santos de Freitas Silva;Fernanda Ferreira Nunes Correia;Eleazar Mezaiko;Camila Ferro de Souza Roriz;Maria Alves Garcia Silva;Deborah Queiroz Freitas;Fernanda Paula Yamamoto-Silva
    • Imaging Science in Dentistry
    • /
    • 제54권2호
    • /
    • pp.159-169
    • /
    • 2024
  • Purpose: The aim of this study was to evaluate the influence of different cone-beam computed tomography (CBCT) acquisition protocols on reducing the effective radiation dose while maintaining image quality. Materials and Methods: The effective dose emitted by a CBCT device was calculated using thermoluminescent dosimeters placed in a Rando Alderson phantom. Image quality was assessed by 3 experienced evaluators. The relationship between image quality and confidence was evaluated using the Fisher exact test, and the agreement among raters was assessed using the kappa test. Multiple linear regression analysis was performed to investigate whether the technical parameters could predict the effective dose. P-values<0.05 were considered to indicate statistical significance. Results: The optimized protocol (3 mA, 99 kVp, and 450 projection images) demonstrated good image quality and a lower effective dose for radiation-sensitive organs. Image quality and confidence had consistent values for all structures (P<0.05). Multiple linear regression analysis resulted in a statistically significant model. The milliamperage (b=0.504; t=3.406; P=0.027), kilovoltage peak (b=0.589; t=3.979; P=0.016) and number of projection images (b=0.557; t=3.762; P=0.020) were predictors of the effective dose. Conclusion: Optimized CBCT acquisition protocols can significantly reduce the effective radiation dose while maintaining acceptable image quality by adjusting the milliamperage and projection images.

X-색도 공간에서 ROI의 전방향 프로젝션과 백색패치의 평행이동에 의한 본질 영상 획득 (Acquisition of Intrinsic Image by Omnidirectional Projection of ROI and Translation of White Patch on the X-chromaticity Space)

  • 김달현;황동국;이우람;전병민
    • 정보처리학회논문지B
    • /
    • 제18B권2호
    • /
    • pp.51-56
    • /
    • 2011
  • 흑체의 온도 변화에 대한 영상의 색차를 줄이는 본질 영상은 단일 불변 방향을 검출하고 백색 장면 조명체를 기반으로 하기 때문에 실영상에 존재하는 다수의 불변 방향과 유색 장면 조명체에 취약하다. 이러한 문제를 해결하기 위해 본 논문에서는 ${\chi}$-색도 공간에서 ROI의 전방향프로젝션과 백색패치의 평행이동을 통해 불변 방향을 검출하는 본질 영상 획득 기법을 제안한다. 3차원 RGB 공간 분석의 어려움으로 인하여, 본 논문 또한 밝기가 고려되지 않은 ${\chi}$-색도 공간을 사용한다. 이 공간에서 유색 조명체의 효과는 백색패치의 평행이동을 통해 감소시키고, 색차에 따라 가상의 선분으로 나타나는 불변 방향은 ROI의 전방향 프로젝션을 통해 검출한다. 다수의 불변 방향을 고려하여 ROI 선택은 3D 히스토그램에서 빈도수에 의해 결정한다. 검출 후, 본질 영상은 불변 방향의 직교 방향으로의 프로젝션과 RGB영상으로의 역변환 과정을 통해 획득된다. 실험에서 Ebner가 제안한 데이터집합을 실험 영상으로 이용하였고, 불변 방향의 표준편차와 색항등성 측도를 평가 측도로 사용하였다. 제안한 기법의 실험 결과는 엔트로피 기법보다 불변 방향의 표준 편차가 낮았으며, 기존의 기법에 비해 색항등성이 2배 이상 높았다.

Resolution analysis of Fourier Hologram using integral imaging

  • Chen, Ni;Park, Jae-Hyeung;Kim, Nam
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2009년도 창립 20주년기념 특별학술발표회
    • /
    • pp.331-332
    • /
    • 2009
  • We present an analysis on the quality factors of the Fourier hologram generated from multiple orthographic view images of three-dimensional object. In the analysis, we analyze both the maximum size of the reconstructed object and its spatial resolution. For the maximum size of the reconstruction, we found that the main factor is the orthographic projection angle interval. Too large projection angle interval causes overlapping in the reconstruction space domain. For the spatial resolution, there are three factors, i.e. the capturing lens array pitch which determines the spatial sampling rate of the original three-dimensional objects, the maximum orthographic projection angle, and the spatial frequency bandwidth of the object. The dominant factor is determined by the relationship between those three factors.

  • PDF

다중 슬릿광을 이용한 3차원 Solder Paste 검사 시스템 (A 3D Solder Paste Inspection System Using Multiple Slit Rays)

  • 조태훈;허병회
    • 제어로봇시스템학회논문지
    • /
    • 제8권2호
    • /
    • pp.151-157
    • /
    • 2002
  • A 3-dimenstional automatic solder paste inspection system is described that can be used to find defects occurring in solder paste printing process. This system extracts height and volume information very fast as well as area of solder paste printed, using multiple slit ray projection and Galvano-mirror scanning. Methods are presented on calibration of camera and slit projector, real-time image processing of multiple slit images, determination of reference height, and extraction of paste height information are proposed. Performance of the system was successfully demonstrated through field tests.