• Title/Summary/Keyword: Multiple installations

Search Result 17, Processing Time 0.02 seconds

Effects of Ground Faults on the Safety of Persons and Low-voltage Installations in 22.9 kV-Y Distribution Systems (22.9 kV-Y 계통에서 지락고장이 인체 및 저압설비의 안전에 미치는 영향)

  • Kim, Han-Soo;Chung, Jae-Hee;Kang, Kae-Myung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.141-148
    • /
    • 2008
  • This paper presents experimental results on the safety of persons and protection of low-voltage equipments of the sub-station due to a single-phase ground fault in 22.9 kV-Y distribution system. In order to evaluate the hazard voltages and the stress voltage of the low-voltage(LV) equipment due to faults between high-voltage systems and earth based on the newly prescribed KS C IEC 60364 standard series, the verification tests in a 22.9[kV] neutral multiple grounding system were carried out. From the experimental results, we introduce serious problems causing some discomfort when applying KS C IEC 60364 standard series to the existing domestic distribution system and the effective protective measures against temporary overvoltages due to a ground fault in the common grounding which is combined the 22.9 kV-Y grounding and the customer's installation grounding are proposed. As a consequence, it was found that the equipotential bonding is an important prerequisite for the effectiveness of the protective measures for the safety of persons and LV equipment in the combined 22.9 kV-Y and low-voltage grounding system.

Fuzzy neural network controller of interconnected method for civil structures

  • Chen, Z.Y.;Meng, Yahui;Wang, Ruei-yuan;Chen, Timothy
    • Advances in concrete construction
    • /
    • v.13 no.5
    • /
    • pp.385-394
    • /
    • 2022
  • Recently, an increasing number of cutting-edged studies have shown that designing a smart active control for real-time implementation requires piles of hard-work criteria in the design process, including performance controllers to reduce the tracking errors and tolerance to external interference and measure system disturbed perturbations. This article proposes an effective artificial-intelligence method using these rigorous criteria, which can be translated into general control plants for the management of civil engineering installations. To facilitate the calculation, an efficient solution process based on linear matrix (LMI) inequality has been introduced to verify the relevance of the proposed method, and extensive simulators have been carried out for the numerical constructive model in the seismic stimulation of the active rigidity. Additionally, a fuzzy model of the neural network based system (NN) is developed using an interconnected method for LDI (linear differential) representation determined for arbitrary dynamics. This expression is constructed with a nonlinear sector which converts the nonlinear model into a multiple linear deformation of the linear model and a new state sufficient to guarantee the asymptomatic stability of the Lyapunov function of the linear matrix inequality. In the control design, we incorporated H Infinity optimized development algorithm and performance analysis stability. Finally, there is a numerical practical example with simulations to show the results. The implication results in the RMS response with as well as without tuned mass damper (TMD) of the benchmark building under the external excitation, the El-Centro Earthquake, in which it also showed the simulation using evolved bat algorithmic LMI fuzzy controllers in term of RMS in acceleration and displacement of the building.

Bearing Capacity Evaluation of Hybrid Suction Bucket Foundations on Clay Under Horizontal Loads Using a Centrifuge (원심모형실험을 활용한 점토지반에 설치된 하이브리드 석션 버켓기초의 수평방향 지지력 평가)

  • Kim, Jae-Hyun;Lee, Cheol-Ju;Shin, Hee Jeong;Kim, Seong Hwan;Goo, Jeong Min;Jung, Chung Yeol;Jeon, Young-Jin
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.12
    • /
    • pp.61-73
    • /
    • 2023
  • Suction buckets are feasible options for offshore foundations to support subsea structures in deep water, enabling suction-induced installation by pumps. Recently, hybrid suction bucket foundations that combine single or multiple suction buckets with a mat foundation have been considered. The foundations effectively increase the load capacity while reducing construction costs. However, there is still insufficient experimental validation of hybrid suction bucket foundations regarding their bearing capacity. Furthermore, research on the horizontal load capacity under low vertical and moment loads is inadequate. In this study, we investigate the feasibility of using a hybrid suction bucket foundation for subsea installations in clay. We considered two types of hybrid suction bucket foundations: a circular mat with a single suction bucket and a square mat with multiple buckets. Centrifuge tests were performed to understand the hybrid suction bucket foundation characteristics under horizontal loads and their corresponding bearing capacity. Particularly, we verified the effect of the mat foundation and bucket embedment depth on the horizontal bearing mechanism and capacities. Results confirmed that the hybrid suction bucket foundation outperforms the single suction bucket.

Development of Greenhouse Cooling and Heating Load Calculation Program Based on Mobile (모바일 기반 온실 냉난방 부하 산정 프로그램 개발)

  • Moon, Jong Pil;Bang, Ji Woong;Hwang, Jeongsu;Jang, Jae Kyung;Yun, Sung Wook
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.419-428
    • /
    • 2021
  • In order to develope a mobile-based greenhouse energy calculation program, firstly, the overall thermal transmittance of 10 types of major covers and 16 types of insulation materials were measured. In addition, to estimate the overall thermal transmittance when the cover and insulation materials were installed in double or triple layers, 24 combinations of double installations and 59 combinations of triple installations were measured using the hotbox. Also, the overall thermal transmittance value for a single material and the thermal resistance value were used to calculate the overall thermal transmittance value at the time of multi-layer installation of covering and insulating materials, and the linear regression equation was derived to correct the error with the measured values. As a result of developing the model for estimating thermal transmittance when installing multiple layers of coverings and insulating materials based on the value of overall thermal transmittance of a single-material, the model evaluation index was 0.90 (good when it is 0.5 or more), indicating that the estimated value was very close to the actual value. In addition, as a result of the on-site test, it was evaluated that the estimated heat saving rate was smaller than the actual value with a relative error of 2%. Based on these results, a mobile-based greenhouse energy calculation program was developed that was implemented as an HTML5 standard web-based mobile web application and was designed to work with various mobile device and PC browsers with N-Screen support. It had functions to provides the overall thermal transmittance(heating load coefficient) for each combination of greenhouse coverings and thermal insulation materials and to evaluate the energy consumption during a specific period of the target greenhouse. It was estimated that an energy-saving greenhouse design would be possible with the optimal selection of coverings and insulation materials according to the region and shape of the greenhouse.

Study on Spatial Characteristics of Student Transfer in Southern Area of Gyeonggi Province (경기도 남부지역 학생이동의 공간적 특성에 관한 연구)

  • Kim, Hyung-Mi;Joo, Kyung-Sik
    • Journal of the Korean association of regional geographers
    • /
    • v.17 no.6
    • /
    • pp.679-697
    • /
    • 2011
  • This study analyzed the characteristics of spaces to and from which middle school students transfer, especially centering around the school districts of Southern area in Gyeonggi Province such as Suwon, Osan, Yongin, and Hwaseong. This study was conducted to provide the suggestions regarding educational policies such as the positioning to appropriate school districts, improving of educational environment, and implementing of educational equity, by analyzing, based on the empirical data, the educational spaces of four cities showing rapid population growth due to recent suburbanization. The characteristics of distribution of variables such as schools for each district affecting the student transfer, housing development, and socioeconomics in the research object region are mainly analyzed through the correlation analysis, multiple regression analysis, and cluster analysis. As a result, there is shown a distinct spatial difference between school districts of the cty downtown and urban fringe, and between school districts of the conventional cities(cities that have been from the past: note of translator) and new land development regions. First, the school districts in the city downtown showed lots of transfers between neighboring school districts, while the school districts in the urban fringes showed transfer-out tendencies strongly. Second, it was the new land development regions where the transfer-in rate is the highest in the Southern area of Gyeonggi Province. Third, the said new land development regions required the supply of educational installations and educational support that can meet educational demands, since these regions have relatively lower qualitied educational environments compared to the conventional cities where the fluidity of students is lower. Fourth, in the summary of all of the said three results, the student transfer in the southern area of Gyeonggi Province was shown in the spaces centering around the multi-core area by reflecting the restructuring of suburban area.

  • PDF

Current Status of MRI Distribution, Prevailing Charges and Analysis of Its Performance (MRI 분포와 관행수가 현황 및 촬영실적 분석)

  • 문옥륜;장원기;이상이;김철웅;최경혜
    • Health Policy and Management
    • /
    • v.8 no.1
    • /
    • pp.155-182
    • /
    • 1998
  • There exists a remarkable differences in use of MRI scanning among income classes. The poor can hardly utilize it. This is because, among high cost technnologies, MRI is the only equipment not covered under health insurance benefits in Korea. This study was designed 1) to reveal the status of nation-wide MRI installation, customary charges and per unit annual scanning performance, and 2) to analyse factors influencing the above variables. The data for this study came from "MRI Prevalence Survey" conducted by the National Federation of Medcial Insurance(NFMI) in 1997, and were analyzed through SAS packages for T-test, analysis of variance and stepwise multiple regression. Data were collected from 188 hospitals equipped with MRI scanners. Major findings are summarized as follows : The number of MRI scanners has increased from 69 in 994 to 158 in 1996(2.3 times) while per unit annual scanning performance has risen by 11.2% from 2,173 cases in 1994 to 2,417 cases in 1996. Such a rapid increase was made possible mainly due to the inclusion of CT scanning under the health insurance benefit package. The customary charges for MRI scanning with or without contrast media, on average, amounted to 484,000 Won and 402,000 Won, respectively, with the percentile increase of 17.8% and 8.1% each during the same time. Korea ranks the third worldwidely in terms of number of MRI installations, 4.8 scanners per one million persons, only next to Japan and United States. Geographical variation of MRI, however, was rather high, 7.91 unit, in Cheju area compared to 1.82 in Kyongnam area. Variations of customary charges of MRI scanning can be explained as much as by 44.8% by both the total amount of claims to NFMI and geographical variable. The charges were more likely to be higher in metropolitan areas like Seoul and in hospitals with a bigger amount of claims. While those of per unit annual scanning performance can be explained as much as by 30.7% by both MRI installation cost and level of MRI-installed organizations. Per capital scannig performance was higher in tertiary hospitals and hospitals equipped with more expensive scanners than hospitals with less expensive scanners. Two measures are called for the remedying the existing excessive abundance in MRI units in korea : One is to set a ceiling of MRI units in an area like a province or a metropolitan district. The other is to establish a committee on introduction of high cost technologies for reviewing its effective use.ctive use.

  • PDF

Reliability Analysis on Firewater Supply Facilities based on the Probability Theory with Considering Common Cause Failures (소방수 공급설비에 대한 공통원인고장을 고려한 확률론적 신뢰도 분석)

  • Ko, Jae-Sun;Kim, Hyo
    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.76-85
    • /
    • 2003
  • In this study, we write down the definitions, their causes and the techniques of analysis as a theoretical consideration of common cause failures, and investigate the limitation and the importance of the common cause failures by applying to the analysis on the fire protection as a representative safety facility. As you can know in the reliability analysis, most impressive cause is the malfunctions of pumping operations; especially the common cause failure of two pumps is dominant. In other words, it is possible to assess system-reliability as twice as actual without CCF From these, CCF is extraordinarily important and the results are highly dependent on the CCF factor. And although it would increase with multiple installations, the reliability are not defined as linear with those multiplications. In addition, the differences in results due to the models for analysis are not significant, whereas the various sources of data produce highly different results. Therefore, we conclude that the reliabilities are dependent on the quality of the usable data much better than the variety of models. As a result, the basic and engineering device for the preventions of CCF of the multiple facilities is to design it as reliably as to design the fire-water pump. That is to say, we must assess those reliabilities using PFD whether they are appropriate to SIL (Safety Integrity Level) which is required for the reliability in SIS (Safety Instrumented System). The result of the analysis on the reliability of the fire-water supply with CCF shows that PFD is 3.80E-3, so that it cannot be said to be designed as safely as in the level of SIL5. However, without CCF, PFD is 1.82E-3 which means that they are designed as unsafely as before.