• 제목/요약/키워드: Multilayer detector

검색결과 20건 처리시간 0.023초

다층구조 엑스선 검출기를 이용한 이중에너지 조영제 영상의 물질 구분에 관한 연구 (A Study on the Material Decomposition of Dual-Energy Iodine Image by Using the Multilayer X-ray Detector)

  • 김준우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권5호
    • /
    • pp.465-471
    • /
    • 2021
  • Dual-energy X-ray imaging (DEI) techniques can provide X-ray images that a certain material is suppressed or emphasized by combining two X-ray images obtained from two different x-ray spectrum. In this paper, a single-shot DEI, which uses stacked two detectors (i.e., multilayer detector), is proposed to reduce the patient dose and increase throughput in angiography. The polymethyl methacrylate (PMMA) and aluminum (Al) were selected as two basis materials for material decomposition, and material-specific images are reconstructed as a vector combination of these two materials. We investigate the contrast and noise performance of material-decomposed images using iodine phantoms with various concentrations and diameters. The single-shot DEI shows comparable performances to the conventional dual-shot DEI. In particular, the single-shot DEI shows edge enhancement in material-decomposed images due to the different spatial-resolution characteristics of upper and lower detectors. This study could be useful for designing the multilayer detector including scintillators and energy-separation filter for angiography purposes.

Test of a Multilayer Dose-Verification Gaseous Detector with Raster-Scan-Mode Proton Beams

  • Lee, Kyong Sei;Ahn, Sung Hwan;Han, Youngyih;Hong, Byungsik;Kim, Sang Yeol;Park, Sung Keun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제4권5호
    • /
    • pp.297-304
    • /
    • 2015
  • A multilayer gaseous detector has been developed for fast dose-verification measurements of raster-scan-mode therapeutic beams in particle therapy. The detector, which was constructed with eight thin parallel-plate ionization chambers (PPICs) and polymethyl methacrylate (PMMA) absorber plates, is closely tissue-equivalent in a beam's eye view. The gas-electron signals, collected on the strips and pad arrays of each PPIC, were amplified and processed with a continuous charge.integration mode. The detector was tested with 190-MeV raster-scan-mode beams that were provided by the Proton Therapy Facility at Samsung Medical Center, Seoul, South Korea. The detector responses of the PPICs for a 190-MeV raster-scan-mode proton beam agreed well with the dose data, measured using a 2D ionization chamber array (Octavius model, PTW). Furthermore, in this study it was confirmed that the detector simultaneously tracked the doses induced at the PPICs by the fast-oscillating beam, with a scanning speed of 2 m s-1. Thus, it is anticipated that the present detector, composed of thin PPICs and operating in charge.integration mode, will allow medical scientists to perform reliable fast dose-verification measurements for typical dynamic mode therapeutic beams.

IN SITU STRESS MEASUREMENTS OF Co-BASED MULTILAYER FILMS

  • Kim, Young-Suk;Shin, Sung-Chul
    • 한국자기학회지
    • /
    • 제5권5호
    • /
    • pp.470-473
    • /
    • 1995
  • We have constructed an apparatus for in sity measurement of stress of the film prepared by sputtering using an optical noncontact displacement detector. A Change of the gap distance between the detector and the substrate, caused by stress of a deposited film, was detected by a corresponding change of the reflectivity. The sensitivity of the displacement detector was $5.9\;{\mu}V/{\AA}$ and thus, it was turned out to be good enough to detect stress caused by deposition of a monoatomic layer. The apparatus was applied to in situ stress measurements of Co/X(X=Pd or Pt) multilayer thin films prepared on the glass substrates by dc magnetron sputtering. At the very beginning of the deposition, both Co and X sublayers have subjected to their own intrinsic stresses. However, when the film was thicker than about $100{\AA}$, constant tensile stress in the Co sublayer and compressive stress in the X sublayer were observed, which is believed to be related to a lattice mismatch between the matching planes of Co and X.

  • PDF

In situ Stress Measurements with Submonolayer Sensitivity As a Probe of Coherent-to-incoherent Matching at an Interface in Ultrathin Magnetic Films

  • Jeong, Jong-Ryul;Kim, Young-Seok;Shin, Sung-Chul
    • Journal of Magnetics
    • /
    • 제7권4호
    • /
    • pp.151-155
    • /
    • 2002
  • In situ stress changes at interfaces of ultrathin magnetic films were measured by means of a non-contact optical fiber bundle displacement detector. A bending of the substrate due to stress of a deposited film was detected in cantilever geometry. The highest sensitivity of 134 mV/$\mu$m for the displacement detector was realized with a help of computer simulation. The detector was applied to in situ stress measurements of Co/Pt and Ni/Pd magnetic multilayer films prepared on the glass substrates by dc magnetron sputtering. The detector turned out to have a submonolayer sensitivity that enables to observe coherent-to-incoherent transition in these mismatched multilayers and even detect the stress changes within the monoatomic coverage. This highly sensitive detector paves new way to probe the stress relaxation at an interface in ultrathin films.

a-Se 기반의 혼합형 X-선 검출기에서 유전층의 누설전류 저감효과 (The dark-current and X -ray sensitivity measurement of hybrid digital X-ray detector having dielectric layer structure)

  • 석대우;박지군;조진욱;이동길;문치웅;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 센서 박막재료 반도체재료 기술교육
    • /
    • pp.31-34
    • /
    • 2002
  • In this paper, the electric properties of amophous selenium multilayer samples has been investigated. In order to develop the hybrid flat-panel digital· X-ray image detector, we measured and analyzed their performance parameters such as the X -ray sensitivity and dark-current for a amophous selenium multilayers X-ray detector with a phosphor layer, The hybrid digital X-ray image detector can be constructed by integrating a phosphor layer (or a scintillative layer) that convert X-ray to a light on a-Se photoconduction mulilayers that convert a light to electrical signal. As results, the dielectric materials such as parylene between the phosphor layer and the top electrode may reduce the dark-current of the samples. Amorphous selenium multilayers having dielectric layer(parylene) has characteristics of low dark-current, high X-ray sensitivity. So we can acquired a enhanced signal to noise ratio. In this paper offer the method can reduce the dark-current in the hybrid X-ray detector.

  • PDF

인쇄회로기판 검사를 위한 단일조사 이중에너지 엑스선 영상기법의 유용성에 관한 연구 (Feasibility of Single-Shot Dual-Energy X-ray Imaging Technique for Printed-Circuit Board Inspection)

  • 김승호;김동운;김대천;김준우;박지웅;박은평;김진우;김호경
    • 방사선산업학회지
    • /
    • 제9권3호
    • /
    • pp.137-141
    • /
    • 2015
  • A single-shot dual-energy x-ray imaging technique has been developed using a sandwich detector by stacking two detectors, in which the front and rear detectors respectively produce relatively lower and higher x-ray energy images. Each detector layer is composed of a phosphor screen coupled with a photodiode array. The front detector layer employs a thinner phosphor screen, whereas the rear detector layer employs a thicker phosphor screen considering the quantum efficiency for x-ray photons with higher energies. We have applied the proposed method into the inspection of printed circuit boards, and obtained dual-energy images with background clutter suppressed. In addition, the single-shot dual-energy method provides sharper-edge images than the conventional radiography because of the unsharp masking effect resulting from the use of different thickness phosphors between the two detector layers. It is promising to use the single-shot dual-energy x-ray imaging for high-resolution nondestructive testing. For the reliable use of the developed method, however, more quantitative analysis is further required in comparisons with the conventional method for various types of printed circuit boards.

4 층 자기연상 다층퍼셉트론을 이용한 키스트로크 기반 사용자 인증 (A 4-layer AaMLP for Keystroke Dynamics Identity Verification)

  • 우은철;조성준
    • 한국경영과학회:학술대회논문집
    • /
    • 대한산업공학회/한국경영과학회 2002년도 춘계공동학술대회
    • /
    • pp.639-644
    • /
    • 2002
  • Password typing is the most wifely ued identity verification method in computer security domain. However, due to its simplicity, it is vulnerable to imposter attacks Keystroke dynamics adds a shield to password. Discriminating imposters from owners is a novelty detection problem. Auto-Associative Multilayer Perceptron (AaMLP) has teen proved to be a good novelty detector. However, the wifely used 2-layer AaMLP cannot identify nonlinear boundaries, which can result in serious problems in computer security. In this paper, a nonlinear model, i.e. 4-layer AaMLP, is proposed to serve as the novelty detector, which can remedy the limitations of 2-layer AaMLP.

  • PDF

화재감지센서 활용을 위한 적층헝 PTC서미스터의 특성에 관한 연구 (A Study on the Characteristics of the Multilayer-Type PTC Thermistor for Fire Detection Sensor)

  • 추순남;백동현
    • 한국화재소방학회논문지
    • /
    • 제19권2호
    • /
    • pp.75-80
    • /
    • 2005
  • 적충형 PTC 서미스터의 특성연구를 위해 $(0.90Ba+0.05Sr+0.05Ca)TiO_3+0.01TiO_3+0.01SiO_2+0.0008MnO_2+0.0018Nb_2O_5$와 같은 실험조성식을 설정한 후 표면실장(SMD) 적층형 PTC 시편을 제작하였다. 그 결과 상온 비저항 값을 크게 낮출 수 있고 용도에 따라 전류용량을 크게 할 수 있었으나 적층화로 인해 peak 비저항이 크게 낮아지고 열용량이 커짐으로써 스위칭(switching)시간이 늦어지는 점을 확인하였다. 전압-전류 특성에서는 적층수가 증가할수록 초기 최대전류값이 증가하며 큐리점에 대응하여 저항값이 급격히 커지는 전이전압(전계)도 증가함을 보였다. 그러나 인가전압(전계)을 증가시킬 경우 peak 비저항값을 높일 수 있어 스위칭시간을 줄일 수 있다 이 소자는 화재감지기의 센서로 활용될 수 있다.

Artificial neural network reconstructs core power distribution

  • Li, Wenhuai;Ding, Peng;Xia, Wenqing;Chen, Shu;Yu, Fengwan;Duan, Chengjie;Cui, Dawei;Chen, Chen
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.617-626
    • /
    • 2022
  • To effectively monitor the variety of distributions of neutron flux, fuel power or temperatures in the reactor core, usually the ex-core and in-core neutron detectors are employed. The thermocouples for temperature measurement are installed in the coolant inlet or outlet of the respective fuel assemblies. It is necessary to reconstruct the measurement information of the whole reactor position. However, the reading of different types of detector in the core reflects different aspects of the 3D power distribution. The feasibility of reconstruction the core three-dimension power distribution by using different combinations of in-core, ex-core and thermocouples detectors is analyzed in this paper to synthesize the useful information of various detectors. A comparison of multilayer perceptron (MLP) network and radial basis function (RBF) network is performed. RBF results are more extreme precision but also more sensitivity to detector failure and uncertainty, compare to MLP networks. This is because that localized neural network could offer conservative regression in RBF. Adding random disturbance in training dataset is helpful to reduce the influence of detector failure and uncertainty. Some convolution neural networks seem to be helpful to get more accurate results by use more spatial layout information, though relative researches are still under way.

단일-공진기로 구성된 주파수-잠금 회로를 이용한 5-GHz 발진기 (A 5-GHz Oscillator Using Frequency-Locked Loop with a Single Resonator)

  • 이창대;이동현;이창환;염경환
    • 한국전자파학회논문지
    • /
    • 제29권11호
    • /
    • pp.842-850
    • /
    • 2018
  • 본 논문에서는 VCO와 주파수검출기(frequency detector)에 각각 별도의 공진기를 사용하여 구성된 기존의 주파수-잠금회로(frequency locked loop: FLL) 구조 발진기를 개선하여, 단일-공진기로 구성된 주파수-잠금 회로를 이용한 구조가 단순화된 5-GHz 발진기의 설계제작을 보였다. 이때 공진기는 VCO 및 주파수검출기 구성에 공용으로 사용된다. 제작된 5-GHz 발진기는 고주파 성능이 우수한 Rogers사의 RO4350B와 상용 FR4 3층 기판을 이종-접합하여 구성하였으며, 주파수 잠금은 약 5 GHz에서 일어나며, 3.8 dBm의 출력을 갖는다. 위상잡음은 offset-주파수 1 kHz를 경계로 1 kHz 이상에서는 VCO의 위상잡음을, 1 kHz보다 낮을 때는 FLL 바탕잡음을 갖도록 하였다. 이와 같이 설정된 루프-필터에 대해 위상잡음의 개선은 offset-주파수 100 Hz에서 약 12 dB의 개선을 보였다.