• 제목/요약/키워드: Multidetector CT

검색결과 98건 처리시간 0.034초

하악골 골절에 대한 파노라마방사선사진의 진단능 (Diagnostic ability of panoramic radiography for mandibular fractures)

  • 이지현;정연화;조봉혜;황대석
    • Imaging Science in Dentistry
    • /
    • 제40권1호
    • /
    • pp.33-38
    • /
    • 2010
  • Purpose : The purpose of this study was to evaluate the diagnostic efficacy of panoramic radiographs for detection of mandibular fractures. Materials and Methods : The sample was comprised of 65 patients (55 fractured, 10 non-fractured) with 92 fracture sites confirmed by multi-detector computed tomography (CT). Panoramic radiographs were evaluated for mandibular fractures by six examiners; two oral & maxillofacial radiologists (observer A&B), two oral & maxillofacial surgeons (observer C&D), and two general dentists (observer E&F). Results : Sensitivity of panoramic radiography for mandibular fractures was 95.7% in observer A&B, 93.5% in observer C&D and 80.4% in observer E&F. The lowest sensitivity was shown in symphyseal/parasymphyseal areas, followed by subcondylar/condylar regions. Conclusion : Panoramic radiography is adequate for detection of mandibular fractures. However, additional multidetector CT is recommended to ascertain some indecisive fractures of symphysis and condyle, and in complicated fractures.

Primary Diffuse Large B-Cell Lymphoma of the Seminal Vesicle: a Case Report

  • Kwag, Kyung Su;Jang, Suk Ki;Yeon, Jae Woo;Kwon, Kye-Won;Son, Jeong Hwan;Kim, Hyuk Jung
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권4호
    • /
    • pp.259-263
    • /
    • 2016
  • Primary diffuse large B-cell lymphoma of the seminal vesicle is an extremely rare disorder, with only two cases reported in the English literature. Here, we present imaging findings of a case of primary diffuse large B-cell lymphoma of the seminal vesicle. On transrectal ultrasonography, the mass presented as a 3.0-cm-sized heterogeneous, hypoechoic lesion in the right seminal vesicle. Computed tomography (CT) revealed a mass with rim-like enhancement in the right seminal vesicle. On magnetic resonance imaging (MRI), the tumor showed iso-signal intensity on T1-weighted images and heterogeneously intermediate-high signal intensity on T2-weighted images. The tumor showed rim-like and progressive enhancement with non-enhancing portion on dynamic scanning. Diffusion restriction was observed in the mass. On fluorodeoxyglucose positron emission tomography-computed tomography (FDG PET/CT) imaging, a high standardized uptake value (maxSUV, 23.5) by the tumor was noted exclusively in the right seminal vesicle.

침습성 양측 척추주위 종양으로 나타난 흉막외 악성 고립섬유 종양: 증례 보고 (Extrapleural Malignant Solitary Fibrous Tumor Presenting as Invasive Bilateral Paravertebral Tumors: A Case Report)

  • 정제원;진소영
    • 대한영상의학회지
    • /
    • 제84권1호
    • /
    • pp.304-310
    • /
    • 2023
  • 고립성 섬유종은 흉막에서 흔히 발생하는 양성 종양으로 알려져 있으나, 신체 어느 곳에서나 발생할 수 있고 10%-30%에서는 악성이다. 전형적으로, 고립성 섬유종은 단일성의 조영증강되는 종괴로 나타나지만, 척추 주위의 양측성 종괴로 나타나는 경우는 보고되어 있지 않다. 이 증례에서는, 등 통증과 만성 농흉의 병력이 있던 88세 남자 환자의 영상 검사에서 침습적인 양측성 척추 주위 종괴가 발견되었고, 만성 농흉과 연관된 흉부 악성 종양을 먼저 의심하였다. CT 유도하 이중구조 바늘 생검을 통해 진단된 양측성의 척추 주위 악성 고립성 섬유종의 증례를 보고한다.

상완신경총의 영상 (Imaging of the Brachial Plexus)

  • 서경진;이정현;이경규
    • Investigative Magnetic Resonance Imaging
    • /
    • 제11권2호
    • /
    • pp.119-126
    • /
    • 2007
  • 상완신경총의 영상 진단은 복잡한 해부학적인 구조와 다양하게 침범하는 병들로 인해 어렵고 도전적이다. 상완신경총 영상 진단의 일차적인 목표는 외상성 손상과 비외상성 손상의 구별이다. MRI의 급속경사와 전용표면코일을 이용한 적절한 공간분해능을 가진 영상기기의 발전과 이를 이용한 다양한 펄스열의 개발이 상완신경총의 외상성 손상과 비외상성 손상에 대한 구별에 많은 도움을 주어 정확한 진단으로 수술 여부의 결정에 이용된다. MRI는 비외상성 상완신경총 병변의 진단에 가장 좋은 영상진단이며, CT 척수강조영술은 상완신경총을 침범하는 신경근견열 병변의 검사에 많이 이용된다. 그리고 일반적으로 고화질, 고해상력의 MRI 가 상완신경총 비외상성병변의 진단에 일차적인 영상검사로 중요한 역할을 하고 있다.

  • PDF

미만성 축삭 손상에서 전산화단층촬영과 경사에코 자기공명영상을 이용한 예후의 평가 (Prognostic Value of Computed Tomography and Gradient-echo Magnetic Resonance Imaging in Diffuse Axonal Injury)

  • 정남기;진상찬;최우익
    • Journal of Trauma and Injury
    • /
    • 제25권4호
    • /
    • pp.122-131
    • /
    • 2012
  • Purpose: Diffuse axonal injury (DAI) is clinically defined as a coma of over six hours in a head trauma victim without a focal mass lesion. The emergency physician usually resuscitates and stabilizes a comatose head trauma victim in the emergency Department. After assessment and treatment, the prognosis is very important to both the victim and the physician. The prognosis for DAI is based on Glasgow Coma Scale (GCS) and other imaging data. We investigated the prognostic value of computed tomography (CT) and gradient-echo magnetic resonance imaging (GRI) for head trauma victims with DAI. Methods: Fifty-three(53) head trauma victims of DAI were enrolled in this study from 2007 to 2012. During the study period of six years, data on trauma victims were collected retrospectively. We analyzed the differences in the Glasgow Outcome Scale (GOS) result between the CT and the GRI modalities. Results: We classified the study group by using GOS. Between the good outcome subgroup (GOS scores of 4 and 5) and the poor outcome subgroup (GOS score of 1-3), there were no statistical difference in sex, age, initial vital signs and initial GCS score. The good outcome subgroup had non-hemorrhage on CT(52%), which was correlated with good outcome and a shorter awakening time, while a larger number and a deeper location of hemorrhagic lesions on in GRI were correlated with poor outcome in DAI. Conclusion: We conclude that the existence of hemorrhagic lesions on CT, and the number and location of those lesions on GRI had good prognostic value for head trauma victims with DAI.

Preoperative Identification of a Perforator Using Computed Tomography Angiography and Metal Clip Marking in Perforator Flap Reconstruction

  • Lee, Jung Woo;Kim, Han Kyeol;Kim, Sin Rak;Han, Yea Sik;Park, Jin Hyung
    • Archives of Plastic Surgery
    • /
    • 제42권1호
    • /
    • pp.78-83
    • /
    • 2015
  • In perforator flap reconstruction, vascular mapping using preoperative computed tomography (CT) angiography is widely used to confirm the existence and location of an appropriate perforator. This study proposes a rapid, accurate, and convenient method for marking the perforator location on the skin surface. For 12 patients who underwent perforator flap reconstruction between November 2011 and November 2013, metal clips were fixed on the skin surface at the anticipated perforator locations, which were decided using a handheld Doppler. CT angiography was used to compare the location between the metal clip and the actual perforator. The metal clip was moved and repositioned, if needed, on the basis of the CT images. The locations of the appropriate perforator and the metal clip, which were observed during the surgery, were then compared. In CT angiography, the mean distance between the metal clip and the perforator was $3{\pm}3.9mm$, and the mean distance that was measured during surgery was $0.8{\pm}0.8mm$. In conclusion, we report a simple, rapid, and precise technique to indicate the accurate location of the appropriate perforator on the skin surface.

Comparison of effective dose for imaging of mandible between multi-detector CT and cone-beam CT

  • Jeong, Dae-Kyo;Lee, Sang-Chul;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • 제42권2호
    • /
    • pp.65-70
    • /
    • 2012
  • Purpose : The aim of this study was to compare the effective dose for imaging of mandible between multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). An MDCT with low dose technique was also compared with them. Materials and Methods : Thermoluminescent dosimeter (TLD) chips were placed at 25 organ sites of an anthropomorphic phantom. The mandible of the phantom was exposed using 2 different types of MDCT units (Somatom Sensation 10 for standard-dose MDCT, Somatom Emotion 6 for low-dose MDCT) and 3 different CBCT units (AZ3000CT, Implagraphy, and Kavo 3D eXaM). The radiation absorbed dose was measured and the effective dose was calculated according to the ICRP 2007 report. Results : The effective dose was the highest for Somatom Sensation 10 (425.84 ${\mu}Sv$), followed by AZ3000CT (332.4 ${\mu}Sv$), Somatom Emotion 6 (199.38 ${\mu}Sv$), and 3D eXaM (111.6 ${\mu}Sv$); it was the lowest for Implagraphy (83.09 ${\mu}Sv$). The CBCT showed significant variation in dose level with different device. Conclusion : The effective doses of MDCTs were not significantly different from those of CBCTs for imaging of mandible. The effective dose of MDCT could be markedly decreased by using the low-dose technique.

Difference in glenoid retroversion between two-dimensional axial computed tomography and three-dimensional reconstructed images

  • Kim, Hyungsuk;Yoo, Chang Hyun;Park, Soo Bin;Song, Hyun Seok
    • Clinics in Shoulder and Elbow
    • /
    • 제23권2호
    • /
    • pp.71-79
    • /
    • 2020
  • Background: The glenoid version of the shoulder joint correlates with the stability of the glenohumeral joint and the clinical results of total shoulder arthroplasty. We sought to analyze and compare the glenoid version measured by traditional axial two-dimensional (2D) computed tomography (CT) and three-dimensional (3D) reconstructed images at different levels. Methods: A total of 30 cases, including 15 male and 15 female patients, who underwent 3D shoulder CT imaging was randomly selected and matched by sex consecutively at one hospital. The angular difference between the scapular body axis and 2D CT slice axis was measured. The glenoid version was assessed at three levels (midpoint, upper one-third, and center of the lower circle of the glenoid) using Friedman's method in the axial plane with 2D CT images and at the same level of three different transverse planes using a 3D reconstructed image. Results: The mean difference between the scapular body axis on the 3D reconstructed image and the 2D CT slice axis was 38.4°. At the level of the midpoint of the glenoid, the measurements were 1.7°±4.9° on the 2D CT images and -1.8°±4.1° in the 3D reconstructed image. At the level of the center of the lower circle, the measurements were 2.7°±5.2° on the 2D CT images and -0.5°±4.8° in the 3D reconstructed image. A statistically significant difference was found between the 2D CT and 3D reconstructed images at all three levels. Conclusions: The glenoid version is measured differently between axial 2D CT and 3D reconstructed images at three levels. Use of 3D reconstructed imaging can provide a more accurate glenoid version profile relative to 2D CT. The glenoid version is measured differently at different levels.

한 대학병원에서 급성 폐색전증으로 진단된 환자들의 임상적 특성 및 예후 (Acute Pulmonary Embolism: Clinical Characteristics and Outcomes in a University Teaching Hospital)

  • 채진녕;최원일;박지혜;노병학;김재범
    • Tuberculosis and Respiratory Diseases
    • /
    • 제68권3호
    • /
    • pp.140-145
    • /
    • 2010
  • Background: Pulmonary embolism (PE) is a common clinical problem in the West that is associated with substantial morbidity and mortality. The diagnostic modality has been changed since 2001. This study retrospectively reviewed the PE mortality with the aim of identifying the risk factors associated with mortality since the multidetector computed tomography (MDCT) was introduced. Methods: We analyzed 105 patients with acute PE proven by multidetector CT or ventilation perfusion scan. The primary outcome measure was the all-cause mortality at 3 months. The prognostic effect of the baseline factors on survival was assessed by multivariate analysis. Results: The main risk factors were prolonged immobilization, stroke, cancer and obesity. Forty nine percent of patients had 3 or more risk factors. The overall mortality at 3 months was 18.1%. Multivariate analysis revealed low diastolic blood pressure and the existence of cancer to be independent factors significantly associated with mortality. Forty two PE patients were examined for the coagulation inhibitors. Four of these patients had a protein C deficiency (9.5%), and 11 had a protein S deficiency (26%). Conclusion: PE is an important clinical problem with a high mortality rate. Close monitoring may be necessary in patients with the risk factors.

심하복벽동맥 천공지 유리피판에서 술전 MDCT의 유용성 (The Value of Preoperative Multidetector Computed Tomography for Deep Inferior Epigastric Artery Perforator Free Flap)

  • 허찬영;홍기용;윤창진;은석찬;백롱민;민경원
    • Archives of Plastic Surgery
    • /
    • 제36권2호
    • /
    • pp.140-146
    • /
    • 2009
  • Purpose: Autologous breast reconstruction with abdominal tissue is one of the best options after mastectomy. In a free transverse rectus abdominis myocutaneous(TRAM) or deep inferior epigastric artery perforator(DIEP) flap, a preoperative evaluation of the precise location of perforating vessels and vascular run - off systems is required. The objective of this report is to demonstrate the usefulness of multidetector computed tomography(MDCT) in the preoperative planning of patients undergoing breast reconstruction with abdominal flap. Methods: From June 2006 to January 2008, 28 patients underwent MDCT evaluation before breast reconstruction. All subjects were females with an age range of 30 to 55 years. The CT scan was performed using a 64 - slice MDCT scanner(Brilliance 64; Philips Medical Systems, Best, Netherlands). Results: One perforator or two major perforators were marked on image in good relation with a hand - held Doppler examination and intraoperative findings. All vascular run - off systems were cleared before operation. Conclusion: Preoperative evaluation of perforator arteries with MDCT angiography is beneficial in patients undergoing breast reconstruction. This technique provides a noninvasive approach of the vascular anatomy of the entire anterior abdominal wall.