• Title/Summary/Keyword: Multi-standard

Search Result 1,624, Processing Time 0.033 seconds

Evaluation of the effective dose and image quality of low-dose multi-detector CT for orthodontic treatment planning (3차원 안모분석을 위한 저선량 Multi-detector CT 영상의 유효선량 및 화질 평가)

  • Chung, Gi-Chung;Han, Won-Jeong;Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.40 no.1
    • /
    • pp.15-23
    • /
    • 2010
  • Purpose : This study was designed to compare the effective doses from low-dose and standard-dose multi-detector CT (MDCT) scanning protocols and evaluate the image quality and the spatial resolution of the low-dose MDCT protocols for clinical use. Materials and Methods : 6-channel MDCT scanner (Siemens Medical System, Forschheim, Germany), was used for this study. Protocol of the standard-dose MDCT for the orthodontic analysis was 130 kV, 35 mAs, 1.25 mm slice width, 0.8 pitch. Those of the low-dose MDCT for orthodontic analysis and orthodontic surgery were 110 kV, 30 mAs, 1.25 mm slice width, 0.85 pitch and 110 kV, 45 mAs, 2.5 mm slice width, 0.85 pitch. Thermoluminescent dosimeters (TLDs) were placed at 31 sites throughout the levels of adult female ART head and neck phantom. Effective doses were calculated according to ICRP 1990 and 2007 recommendations. A formalin-fixed cadaver and AAPM CT performance phantom were scanned for the evaluation of subjective image quality and spatial resolution. Results : Effective doses in ${\mu}Sv$ ($E_{2007}$) were 699.1, 429.4 and 603.1 for standard-dose CT of orthodontic treatment, low-dose CT of orthodontic analysis, and low-dose CT of orthodontic surgery, respectively. The image quality from the low-dose protocol were not worse than those from the standard-dose protocol. The spatial resolutions of both standard-dose and low-dose CT images were acceptable. Conclusion : From the above results, it can be concluded that the low-dose MDCT protocol is preferable in obtaining CT images for orthodontic analysis and orthodontic surgery.

A 3.3-V Low-Power Compact Driver for Multi-Standard Physical Layer

  • Park, Joon-Young;Lee, Jin-Hee;Jeong, Deog-Kyoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.7 no.1
    • /
    • pp.36-42
    • /
    • 2007
  • A low-power compact driver for multistandard physical layer is presented. The proposed driver achieves low power and small area through the voltage-mode driver with trans-impedance configuration and the novel hybrid driver,. In the voltage-mode driver, a trans-impedance configuration alleviates the problem of limited common-mode range of error amplifiers and the area and power overhead due to pre-amplifier. For a standard with extended output swing, only current sources are added in parallel with the voltage-mode driver, which is named a 'hybrid driver'. The hybrid architecture not only increases output swing but reduces overall driver area. The overall driver occupies $0.14mm^2$. Power consumptions under 3.3-V supply are 24.5 mW for the voltage-mode driver and 44.5 mW for the hybrid driver.

Multi-Channel Two-Stage 시스템을 이용한 수질 독성 모니터링의 지표 확립 및 모사

  • Kim, Byeong-Chan;Gu, Man-Bok
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.715-718
    • /
    • 2000
  • The character of a recombinant bioluminescent bacteria's light emission enables us to monitor toxicity in water, soil and air. In this study, various bioluminescent responses to water samples containing toxic chemicals, such as phenol and mitomycin C, were obtained and analysed through the use of a multi-channel two-stage minibioreactor system. The bioluminescent pattern from each channel can be used as a standard for identifying the degree of toxicity in field samples. When various concentrations of toxic chemicals were injected in a step manner, different bioluminescent patterns were obtained. Also this system showed variation in its bioluminescent pattern as the injection manner was changed, i.e. using a modified version of the bell-curve type injection. In conclusion, the toxicity was shown to be related with the bioluminescent response when using these standard bioluminescent patterns. Comparing this standard with a bioluminescent response from a field sample, we can estimate the degree of which the sample is toxic.

  • PDF

Fast Multi-Frame Motion Estimation Algorithm for H.264 Video Coding (H.264/AVC용 고속 다중 참조영상 움직임 예측 알고리즘)

  • Byun, Ju-Won;Choi, Jin-Ha;Kim, Jae-Seok
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.795-796
    • /
    • 2008
  • H.264/AVC standard adopts multiple reference frames for motion estimation. This method improves coding efficiency, but it increases complexity of encoder. In this paper, we propose a algorithm that reduces the search range by using the correlation of motion vector. Consequently, motion estimation processing time is 47.5% when compared with standard of five reference frames, and SNR and bitrate are better than that of standard of three multi reference frames.

  • PDF

A Study on the Effects of Root Gap on Mechanical Properties and Microstructure of Weldment (루트간격이 용접부의 기계적 성질과 미세조직에 미치는 영향에 관한 연구)

  • Lee, Won-Kun;Jang, Gyoung-Boc;Kang, Sung-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.10
    • /
    • pp.187-193
    • /
    • 1999
  • Dimensional difference by welding deformation is usually occurred at steel bridge manufacturting or multi-pass welding used at joining of thick plates. Be this, root gap out of standard is frequently developed at butt weld joints. For example, although standard root gap below 6mm at butt weld joints of plates under 15mm thickness, maximum 30mm root opening is developed at the weld field. At this case, 24mm parts out of standard is generally built up. But, there are no accumulated data and restriction about this built up welding pars. In this study, therefore, the accumulation of data for built up parts and the verification of the mechanical properties of weld part as root gap is performed. It is included that tensile, bending, impact, hardness test and microstructural review for each welding specimen of 0mm, 6mm, 30mm root opening.

  • PDF

Area-Optimized Multi-Standard AES-CCM Security Engine for IEEE 802.15.4 / 802.15.6

  • Choi, Injun;Kim, Ji-Hoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.3
    • /
    • pp.293-299
    • /
    • 2016
  • Recently, as IoT (Internet of Things) becomes more important, low cost implementation of sensor nodes also becomes critical issues for two well-known standards, IEEE 802.15.4 and IEEE 802.15.6 which stands for WPAN (Wireless Personal Area Network) and WBAN (Wireless Body Area Network), respectively. This paper presents the area-optimized AES-CCM (Advanced Encryption Standard - Counter with CBC-MAC) hardware security engine which can support both IEEE 802.15.4 and IEEE 802.15.6 standards. First, for the low cost design, we propose the 8-bit AES encryption core with the S-box that consists of fully combinational logic based on composite field arithmetic. We also exploit the toggle method to reduce the complexity of design further by reusing the AES core for performing two operation mode of AES-CCM. The implementation results show that the total gate count of proposed AES-CCM security engine can be reduced by up to 42.5% compared to the conventional design.

Multi-focal Microscopic System Using a Fiber Bundle (광섬유 다발을 이용한 다초점 현미경)

  • Gu, Young-Mo;Ham, Hyo-Shick;Choi, Sung-Eul
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.6
    • /
    • pp.354-360
    • /
    • 2009
  • We have constructed and analyzed the performance of a simple fiber bundle multi-focal microscope. The microscope had a fiber bundle substituted for micro-lens array that is the core part of MMM(multi-focal multi-photon microscope). The MMM is a type of confocal microscope. To analyze the performance and characteristics of the fiber bundle multi-focal microscope, three types of samples were used: a standard grating, USAF 1951(7, 3), and 1951(7, 6). Using two polarizers and a polarizing beam splitter, we eliminated noise and got clear images. We obtained the FWHM of fiber spot images with the standard grating using two different magnifier lenses which were 63X and 20X, and found an image of the sample as a distribution of fiber spot images. For this case we used the low magnification lens, which gives denser distribution, so that we could get clearer images. In order to test the resolution of the fiber bundle multi-focal microscopic system, we used the USAF 1951 sample which has a smaller line interval than that of the standard grating. The FWHM of the line width of the image coincides well with the real line width of the USAF 1951 sample. We confirmed the performance of a fiber bundle multi-focal microscopic system which is relatively simple but has submicron resolution and is able to get 1600 images at the same time.

Development of Multi-Chemical Supply System for Semiconductor Wafer Cleaning Station

  • Chung, Myung-Jin;Song, Young-Wook
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1309-1312
    • /
    • 2005
  • A multi-chemical supply system is developed and applied to a wet station, which uses the multi-chemical process in one bath. To control the concentration of two chemicals, control logic of a supply pump is programmed using the programable logic controller (PLC). By using the multi-chemical supply system, wet station with single bath is applied to cleaning process using multi chemicals such as buffed oxide etchant (BOE) and standard clean 1 (SC-1). The concentration of each chemical is measured in the bath to verify the multi-chemical supply system. The control range in the each chemical concentration is measured to 1.33weight% in NH4OH and 0.23weight% in H2O2. The multi-chemical supply system can be movable and usable as an independent module of fixed wet station. By simply midifying the PLC, a multi-chemical supply system can be developed for a wet station.

  • PDF

Exogenous emulsifiers and multi-enzyme combination improves growth performance of the young broiler chickens fed low energy diets containing vegetable oil

  • Wickramasuriya, Samiru Sudharaka;Macelline, Shemil Priyan;Kim, Eunjoo;Shin, Taeg Kyun;Cho, Hyun Min;Jayasena, Dinesh D.;Heo, Jung Min
    • Animal Bioscience
    • /
    • v.35 no.10
    • /
    • pp.1585-1591
    • /
    • 2022
  • Objective: The present study examined the effects of exogenous emulsifiers and multi-enzyme supplementation into a low energy density diet on growth performance, visceral organ parameters, blood metabolites, ileal morphology, and nutrient digestibility in broiler chickens from hatch to 21 days. Methods: One hundred and sixty-eight one-day-old Ross 308 broiler chickens were allocated in a completely randomized design to 24 pens and each pen was assigned to one of four dietary treatments to give six replications with seven chickens in a cage. Dietary treatments were: i) positive control with standard energy level (PC); ii) negative control with 100 kcal/kg lower energy of the standard level (NC); iii) NC diet supplemented 0.05% calcium stearoyl-2 lactylate as an emulsifier (NC+E); and iv) NC diet supplemented with both 0.05% calcium stearoyl-2 lactylate and 0.05% multi-enzyme (NC+E+M). Corn and soybean meal-based control diets containing vegetable oil were formulated to meet the Ross 308 nutrition specification. Chickens were fed ad-libitum with the treatment diets and sampling was conducted on day 21. Results: Our results revealed that emulsifier and multi-enzyme supplementation into NC diets improved (p<0.05) feed efficiency of the broiler chickens compared to the broiler chickens fed NC diets from hatch to 21 days. Supplementation of emulsifier and multi-enzyme into NC diet improved (p<0.05) nutrient digestibility of the broiler chickens. However, emulsifier and multi-enzyme supplementation into diet did not influence (p>0.05) visceral organ weight, blood metabolites, and intestinal morphology in broiler chickens fed NC diets. Conclusion: Supplementation of emulsifier and multi-enzyme in the NC diet would support improving growth performance in young broiler chickens with improved feed efficiency and increased nutrient digestibility thereby curtailing the negative impact of energy reduction in the diets.

A Study on the Understanding of Multi Pilot License and its Introduction Plan (부조종사 자격증명(MPL: Multi-Crew Pilot License)의 이해와 도입 방안에 관한 연구)

  • Hwang, Jae-Gab;Yoo, Byeong-Seon
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.18 no.2
    • /
    • pp.41-45
    • /
    • 2010
  • It is often misled that Multi Pilot License is introduced by International Civil Aviation Organization for the shortage of pilots. The truth is, however, that the license is focused on efficient training of co-pilots in the airline transportation system which an autopilot system is increasing in the Multi Crew environment. ICAO has been researching on the license since 1982, and made it international standard on 2006. Currently, co-pilots trained under Multi-Crew Pilot License courses are continuously increasing over the world. Although the license has introduced to Korea in September 10, 2009, it has not won popular support yet. This paper will lead people to precise understanding of Multi-Crew Pilot License and suggest its introduction plan.