• Title/Summary/Keyword: Multi-purpose measurement system

Search Result 91, Processing Time 0.025 seconds

Implementation of Occupant Density and Walking Pattern Measurement for Emergency Evacuation and Safety in High-Rise Multi-Purpose Facilities

  • Lee, Myung Sik
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.4
    • /
    • pp.409-415
    • /
    • 2018
  • Recently, many countries around the world began to show interest in safety against terrorism, fire, and natural disasters. This study aimed to propose a quantitative measurement system for emergency evacuation and safety for various kinds of terrorism and fire within high-rise multi-purpose facilities, which can measure the pedestrians' ordinary walking patterns in the concourse with the highest pedestrian volume out of all the spaces within multi-story buildings, predict pedestrians' evacuation walking lines when a sudden disaster breaks out, and analyze the gait coefficient, occupant density, and evacuation behavior time.

Development of Multi-Channel DCPD System for Surface Crack Measurement (표면균열 형상측정을 위한 다채널 DCPD 시스템의 개발)

  • Shim D.J.;Park H.L.;Choi J.B.;Kim Y.J.
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.1 s.9
    • /
    • pp.49-54
    • /
    • 2000
  • The DCPD(Direct Current Potential Drop) method has been adopted for the crack measurement of a structure. The objective of this paper is to develop a multi-channel DCPD system not only for detecting crack depth, but also for determining the accurate shape of the surface crack. For this purpose, an exclusive software was also developed. In order to verify the developed DCPD system it was initially tested on a CT specimen, and subsequently was applied to a wide plate specimen. The developed multi-channel DCPD system was proven to provide an efficient and accurate measurement of a surface crack during the crack growth.

  • PDF

Development of neutron time-of-flight measurement system for 1.7-MV tandem proton accelerator with lithium target

  • Lim, Soobin;Kim, Donghwan;Kang, Jin-Goo;Dang, Jeong-Jeung;Lee, Pilsoo;Kim, Geehyun;Chung, Kyoung-Jae;Hwang, Y.S.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.437-441
    • /
    • 2022
  • In this study, we developed a neutron time-of-flight (nTOF) measurement system for a 1.7-MV tandem proton accelerator with a target covered with 300-nm-thick lithium (Li) layer. With implementation of beam chopping module after its ion source, the accelerator is configured to operate in pulsed-beam mode with a pulse width <50 ns at 20-kHz repetition rate. This enables the gamma flash-type nTOF measurement system to identify the neutron generated with 3-MeV proton beam energy. The nTOF system consists of a 30" cylindrical NaI(Tl) and four stilbene scintillation detectors. The NaI(Tl) scintillator is placed 50 cm from the Li target to measure the time of beam irradiation on the target, and the stilbene detectors are placed 2 and 2.4 m away to measure nTOF at each location. The nTOF system successfully measured the generated neutron energy at irradiated proton energies of 2.6 and 3.0 MeV with an average energy resolution of 15%.

A Study on Multi-Sensor System for Detection of Chronic Mild Stress (만성스트레스 검출을 위한 멀티 센서시스템 연구)

  • Lee, Ji-Hyeoung;Kim, Kung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.6
    • /
    • pp.1131-1135
    • /
    • 2010
  • The development of modern civilization result from the abundance of material. Yet modern people live with chronic mild stress. Excessive chronic mild stress leads to various diseases. From the risk of the disease in order to protect our bodies need to manage chronic mild stress. The purpose of this study is to inspection the effectiveness of detecting in chronic mild stress using the Multi-sensor system. The Multi-sensor system is designed that can be measure three kinds of vital signals of chronic mild stress for the detection. First Photoplethysmogram(PPG), second Electro Dermal Activity(EDA), third Skin Temperature(SKT). The ages and occupations exposed to chronic mild stress, people often use out of this system was applied to dairy products(Pen). In addition, vital signals that occur when the variety of noise was used to remove the accelerometer. Chronic mild stress by the analysis of measured vital signals from Multi-sensor system to the measurement information to a PC to a wireless transmission(Bluetooth). In this study, using Multi-sensor system writing conditions and a variety of situations in the movement to measure vital signals and measurement results verified the accuracy and reliability. Through this measure chronic mild stress in everyday life and managing to maintain will help more healthy lifestyle.

Development of Multi-Frequency Impedance Measurement System for Acupuncture Points and Preliminary Report of Measurement Results (Multi-frequency 자극 방식을 이용한 생체 전기 임피던스 측정 시스템 설계 및 경혈의 전기적 특이성에 대한 고찰)

  • Kim, Soo-Byeong;Lee, Na-Ra;Lee, Seung-Wook;Choi, Jun-Young;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.29 no.1
    • /
    • pp.71-81
    • /
    • 2012
  • Objectives : The purpose of this paper was to suggest new diagnostic method that was to supersede the estimation of electrical properties at acupoints. Thus, we developed the multi- frequencies bioelectrical impedance measurement system so as to analyze the state of bio-ions in body fluid as body compositions, not skin impedance at acupoint. Methods : At low frequency, the current does not penetrate the cell membrane and at high frequency, the current passes through both intracellular and extracellular fluid because of the decreas of cell membrane impedance. To confirm the reflection of composition in extracellular fluid or intracellular fluid of segment such as acupoint, the system was developed to detect the acupoint potential between adjacent two points in the area of LU3, LU4 and LU9 using 5,50 and 200KHz. Results : The detected acupoint potential has been decreased according to elevation of frequency. As a result of correlation of left/right identical acupoint, we observed a high correlation of three types of acupoint potential at multi-frequencies. Moreover, we observed the low correlation at 5KHz, and that was a significant factor to be considered as unbalanced relationship of identical acupoints. Conclusions : On the basis of meridian theoretical point of view, we may infer the acupoint's physiological composition using the multi-frequencies bioelectrical impedance measurement system.

THE COMPARATIVE STUDY ON THE SHEARBOND STRENGTH AND THE MORPHOLOGY OF RESIN-DENTIN INTERFACE BONDED BY SEVERAL DENTINAL BONDING SYSTEM (수종의 상아질 결합체의 전단강도 및 결합부의 형태에 관한 비교연구)

  • Kim, Yun-Cheol;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.23 no.4
    • /
    • pp.867-886
    • /
    • 1996
  • The purpose of this study was to evaluate the shearbond strength and resin-dentin interface of three different dentinal bonding systems in primary and permanent teeth. Thirty extracted human primary molars and premolars, which were non-carious and free of obvious defect, were selected for this study. All specimens were divided into six groups with two groups allocated for each of the three dentinal bonding system(All-bond 2, Scotchbond Multi-Purpose, Gluma bonding system). After completion of bonding composite to dentin using each tested dentin bonding system, bond strength measurement and histological observation were performed. The results are as follows: 1. All-bond 2 and Scotchbond Multi-Purpose, A good quality hybrid layer was identified, the morphology of which could be equated with the zone of H-E and Brown-Brenn staining. In Gluma bonding system, hybrid layer was very thin, and separated from the solid polymer. 2. All-bond 2 had the highest mean shearbond strength, followed by Scotchbond Multi-Purpose and Gluma bonding system in both primary and permanent teeth. There was no statistically significant difference between All-bond 2 and Scotchbond Multi-Purpose. Statistically significant difference could be found between Gluma bonding system and the other two groups(p<0.05). 3. The fracture patterns observed were mainly the mixture of adhesive failure and dentin dettachment pattern in All-bond 2 and Scotchbond Multi-Purpose while adhesive failure prevailed in Gluma bonding system.

  • PDF

Development of SFM System for Nano In-Process Profile Measurement (나노인프로세스 표면형상계측을 위한 SFM시스템의 개발)

  • Kweon, Hyun-Kyu;Choi, Seong-Dae;Hong, Sung-Wook
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.3 no.2
    • /
    • pp.53-59
    • /
    • 2004
  • In this paper, we propose a new multi-purpose Scanning Force Microscope (SFM) system. The system can be used for nano/micro-scratching, in-process profile measurement, and observation of potential surface defects which occur during the scratching in air or liquid. Experimental results of nano/micro-scratching show that the smallest scratching depth can be controlled to be 10nm, which corresponds to the stability of the SFM system. Profile measurements of nano/micro-scratching surfaces have also been performed by the method of on-machine measurement and in-process measurement. Two measurement results were in good agreement with each other. The maximum difference was approximately 10 nm, which was mainly caused by the sampling repeatability error that influences the measurement accuracy Also, micro-defects on the micro-scratching surface were successfully detected by the SFM system. It was confirmed that the number of micro-defects increases when the surface is subjected to a cyclic bending load. The maximum depth was less than 100nm.

  • PDF

Building a Sustainable Competitive Advantage for Multi-Level Marketing (MLM) Firms: An Empirical Investigation of Contributing Factors

  • Keong, Lee Siew;Dastane, Omkar
    • Journal of Distribution Science
    • /
    • v.17 no.3
    • /
    • pp.5-19
    • /
    • 2019
  • Purpose - The purpose of this research is to investigate the factors contributing to sustainable competitive advantage for multi-level marketing (MLM) firms in Malaysia. The selected variables in this study are company image, product innovation, leadership, distributor rewards system and distributor training system. Research design, data, and methodology - Quantitative research method is employed with collected sample size of 398 respondents using judgmental sampling technique. Normality and reliability test were performed in the first stage utilizing SPSS 22 and Confirmatory Factory Analysis (CFA) and variance analysis were obtained in the subsequent stage, following up with the overall fit of the measurement model, Structural Equation Model (SEM) using AMOS 22 with maximum likelihood estimation to assess the internal consistency, convergent validity and discriminant validity. Results - The research findings show that company image, leadership, distributor rewards system and distributor training system were supported and are factors affecting the sustainable competitive advantage of MLM companies in Malaysia. However, in this study, product innovation was not supported but this result does not depict that it is trivial and inconsequential in maintain sustainable advantage. Conclusion - Companies can build sustainable competitive advantage by focusing on these contributing factors. Several other comments and implications were brought to light and discussed in the paper.

Test and Evaluation of a Newly Built Multi-purpose Transmission Type Polariscope (다목적 투과형 편광기 시험 및 평가)

  • Baek Tae Hyun;Kim Myung Soo;Lee Choon Tae;Kim Whan;Park Tae Guen
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.1
    • /
    • pp.73-81
    • /
    • 2005
  • A multi-purpose polariscope is developed by applying an electro-mechanical control system to a diffused transmission-type circular polariscope. A conventional polariscope is only good for manual control of optical elements. The new polariscope system is devised to be controlled through two stepping motors and two magnetic clutches. The developed system has both functions of a conventional linear- and circular-polariscope. The new polariscope can be used not only for the point-wise measurement using Tardy compensation technique but also for the full-field fringe analysis using conventional and/or phase measuring techniques, if applicable.

A Study on a Proper Reduction Process of Indoor Air Pollutants In Newly-Constructed Multi-Family Houses (신축공동주택에서의 실내공기 오염물질 방출 저감 프로세스에 관한 연구)

  • Yu Hyung-Ku;Park Jin-Chul;Rhee Eon-Ku
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.468-476
    • /
    • 2005
  • The purpose of this study is to investigate actual air quality in newly-constructed multi-family houses and to improve Indoor Air Quality (IAQ). The field measurement was conducted in four different newly-constructed multi-family house complexes in Seoul and one existing multi-family house complex in Kyong-gi province. The result of the measurement shows that indoor concentrations of Formaldehyde and TVOC in newly-constructed multi-family houses are much higher than the foreign standards. To establish a proper process for reducing indoor air pollutants, various experiments have been conducted; application of natural materials, bake-out practice, closure of all openings without ventilation, and use of mechanical ventilation system. The result indicates that three practices (natural materials, bakeout, mechanical ventilation) can reduce the level of indoor air pollutants almost in half during the experiments. However, each practice has its limitation and is insufficient to satisfy IAQ standards. Therefore, the study proposes a proper reduction process of indoor air pollutants which combines four different practices in time sequence.