• Title/Summary/Keyword: Multi-protocol

Search Result 1,146, Processing Time 0.029 seconds

A Study on the Prediction Method of Information Exchange Requirement in the Tactical Network (전술네트워크의 정보교환요구량 예측 방법에 관한 연구)

  • Pokki Park;Sangjun Park;Sunghwan Cho;Junseob Kim;Yongchul Kim
    • Convergence Security Journal
    • /
    • v.22 no.5
    • /
    • pp.95-105
    • /
    • 2022
  • The Army, Navy, and Air Force are making various efforts to develop a weapon system that incorporates the 4th industrial revolution technology so that it can be used in multi-domain operations. In order to effectively demonstrate the integrated combat power through the weapon system to which the new technology is applied, it is necessary to establish a network environment in which each weapon system can transmit and receive information smoothly. For this, it is essential to analyze the Information Exchange Requirement(IER) of each weapon system, but many IER analysis studies did not sufficiently reflect the various considerations of the actual tactical network. Therefore, this study closely analyzes the research methods and results of the existing information exchange requirements analysis studies. In IER analysis, the size of the message itself, the size of the network protocol header, the transmission/reception structure of the tactical network, the information distribution process, and the message occurrence frequency. In order to be able to use it for future IER prediction, we present a technique for calculating the information exchange requirement as a probability distribution using the Poisson distribution and the probability generating function. In order to prove the validity of this technique, the results of the probability distribution calculation using the message list and network topology samples are compared with the simulation results using Network Simulator 2.

Multiple Case Analysis Study on Business Model Types and Components of Startups: Focusing on Leading Overseas Smart Farm Companies (스타트업의 비즈니스 모델 유형 및 구성요소에 대한 다중 사례 분석 연구: 해외 스마트팜 선도기업을 중심으로)

  • Ahn, Mun Hyoung
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.18 no.6
    • /
    • pp.41-55
    • /
    • 2023
  • In order to secure sustainable competitiveness of startups, business model innovation is an important task to achieve competitive advantage by transforming the various elements that make up the business model. This study conducted a multi-case analysis study on leading smart farm companies around the world using an analysis framework based on business model theory. Through this, we sought to identify business model types and their constituent elements. For this, 19 companies were selected from the list of top 10 investment startups of the year for the past three years published by Agfunder, a global investment research company specializing in AgTech. Then data collection and analysis of the company cases were conducted according to the case study protocol. As a result of the study, the business model types were analyzed into four types: large-scale centralized production model, medium-to-large local distributed production model, small-scale hyperlocal modular FaaS model, and small-scale hyperlocal turnkey solution supply model. A comparative analysis was conducted on five business model components for each type, and strategic implications were derived through this. This study is expected to contribute to improving the competitiveness of domestic smart farm startups and diversifying their strategies by identifying the business models of overseas leading companies in the smart farm field using an academic analysis framework.

  • PDF

Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT) (3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Byeong-Il;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.318-324
    • /
    • 2004
  • Purpose: Philips GEMINI is a newly introduced whole-body GSO PET/CT scanner. In this study, performance of the scanner including spatial resolution, sensitivity, scatter fraction, noise equivalent count ratio (NECR) was measured utilizing NEMA NU2-2001 standard protocol and compared with performance of LSO, BGO crystal scanner. Methods: GEMINI is composed of the Philips ALLEGRO PET and MX8000 D multi-slice CT scanners. The PET scanner has 28 detector segments which have an array of 29 by 22 GSO crystals ($4{\times}6{\times}20$ mm), covering axial FOV of 18 cm. PET data to measure spatial resolution, sensitivity, scatter fraction, and NECR were acquired in 3D mode according to the NEMA NU2 protocols (coincidence window: 8 ns, energy window: $409[\sim}664$ keV). For the measurement of spatial resolution, images were reconstructed with FBP using ramp filter and an iterative reconstruction algorithm, 3D RAMLA. Data for sensitivity measurement were acquired using NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves after we confirmed that dead time loss did not exceed 1%. To measure NECR and scatter fraction, 1110 MBq of F-18 solution was injected into a NEMA scatter phantom with a length of 70 cm and dynamic scan with 20-min frame duration was acquired for 7 half-lives. Oblique sinograms were collapsed into transaxial slices using single slice rebinning method, and true to background (scatter+random) ratio for each slice and frame was estimated. Scatter fraction was determined by averaging the true to background ratio of last 3 frames in which the dead time loss was below 1%. Results: Transverse and axial resolutions at 1cm radius were (1) 5.3 and 6.5 mm (FBP), (2) 5.1 and 5.9 mm (3D RAMLA). Transverse radial, transverse tangential, and axial resolution at 10 cm were (1) 5.7, 5.7, and 7.0 mm (FBP), (2) 5.4, 5.4, and 6.4 mm (3D RAMLA). Attenuation free values of sensitivity were 3,620 counts/sec/MBq at the center of transaxial FOV and 4,324 counts/sec/MBq at 10 cm offset from the center. Scatter fraction was 40.6%, and peak true count rate and NECR were 88.9 kcps @ 12.9 kBq/mL and 34.3 kcps @ 8.84 kBq/mL. These characteristics are better than that of ECAT EXACT PET scanner with BGO crystal. Conclusion: The results of this field test demonstrate high resolution, sensitivity and count rate performance of the 3D PET/CT scanner with GSO crystal. The data provided here will be useful for the comparative study with other 3D PET/CT scanners using BGO or LSO crystals.

ICT Medical Service Provider's Knowledge and level of recognizing how to cope with fire fighting safety (ICT 의료시설 기반에서 종사자의 소방안전 지식과 대처방법 인식수준)

  • Kim, Ja-Sook;Kim, Ja-Ok;Ahn, Young-Joon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.1
    • /
    • pp.51-60
    • /
    • 2014
  • In this study, ICT medical service provider's level of knowledge fire fighting safety and methods on coping with fires in the regions of Gwangju and Jeonam Province of Korea were investigated to determine the elements affecting such levels and provide basic information on the manuals for educating how to cope with the fire fighting safety in medical facilities. The data were analyzed using SPSS Win 14.0. The scores of level of knowledge fire fighting safety of ICT medical service provider's were 7.06(10 point scale), and the scores of level of recognizing how to cope with fire fighting safety were 6.61(11 point scale). level of recognizing how to cope with fire fighting safety were significantly different according to gender(t=4.12, p<.001), age(${\chi}^2$=17.24, p<.001), length of career(${\chi}^2$=22.76, p<.001), experience with fire fighting safety education(t=6.10, p<.001), level of subjective knowledge on fire fighting safety(${\chi}^2$=53.83, p<.001). In order to enhance the level of understanding of fire fighting safety and methods of coping by the ICT medical service providers it is found that: self-directed learning through avoiding the education just conveying knowledge by lecture tailored learning for individuals fire fighting education focused on experiencing actual work by developing various contents emphasizing cooperative learning deploying patients by classification systems using simulations and a study on the implementation of digital anti-fire monitoring system with multipoint communication protocol, a design and development of the smoke detection system using infra-red laser for fire detection in the wide space, video based fire detection algorithm using gaussian mixture mode developing an education manual for coping with fire fighting safety through multi learning approach at the medical facilities are required.

Critical Pathway for Operable Gastric Cancer (위암수술 환자에서의 Critical Pathway의 개발과 적용)

  • Song, Kyo-Young;Kim, Seung-Nam;Park, Cho-Hyun
    • Journal of Gastric Cancer
    • /
    • v.5 no.2
    • /
    • pp.95-100
    • /
    • 2005
  • Purpose: Critical pathways (CP), also known as clinical pathways, are management plans that display goals for patients and have led to improved outcomes for many disease entities. This study was aimed at developing a critical pathway for the surgical treatment of gastric cancer patients and evaluating its usefulness. Materials and Methods: A CP was developed and implemented by a team of surgeons, nurses, nutritionists, and administrative officials. Among the 117 patients who received curative gastrectomies for gastric cancer at Kangnam St. Mary's Hospital, The Catholic University of Korea, between October 2003 and August 2004, 26 patients were treated according to the CP. We evaluated its usefulness by comparing the clinical characterisctics, postoperative progress, hospital stays, and costs between the CP and the non-CP groups. Patient satisfaction was also surveyed with questionnaires. Results: Of the initial 26 patients in the CP group, two were excluded from the final evaluation; one patient had a duodenal stump leakage, and the other had a gastric stasis postoperatively. In 8 patients, protocol violation occurred; six patients refused to be discharged on the $7^{th}$ postoperative day, one patient who had an gastric staisis postoperatively stayed for 2 additional days, and one patient who needed ICU care stayed for 4 additional days. The drop-out rate was $7.7\%$ (2/26), and the variance rate was $30.8\%$ (8/26). The mean hospital stay was 11.3 days ($10\~15$ days) for the CP group compared with 17.5 days ($9\∼68$ days) for the non-CP group, resulting in a difference of about 6 days (P<0.05). The mean hospital stays after surgery were 10.3 days ($7\∼68$ days) and 8.3 days ($7\∼12$ days) for the non-CP and the CP groups, respectively, but the difference was statistically not significant (P>0.05). The mean charge during the hospital stay was higher in the non-CP group ( $\\$ 6,292,200) than in the CP group ( $\\$ 4,863,685). The charge per hospital day was higher in the CP group ( $\\$ 430,414) than in the non-CP group ( $\\$ 359,554). Patient satisfaction was higher in the CP group than in the non-CP group. Conclusion: By developing and applying a critical pathway in the surgical treatment of stomach cancer patients, we could reduce the length of hospital stay as well as the cost. A multi-centered prospective study to establish a standard treatment pathway and to demonstrate its effectiveness is needed in the future.

  • PDF

The Safety and Immunogenicity of a Trivalent, Live, Attenuated MMR Vaccine, PriorixTM (MMR(Measles-Mumps-Rubella) 약독화 생백신인 프리오릭스주를 접종한 후 안전성과 유효성의 평가에 관한 연구)

  • Ahn, Seung-In;Chung, Min-Kook;Yoo, Jung-Suk;Chung, Hye-Jeon;Hur, Jae-Kyun;Shin, Young-Kyu;Chang, Jin-Keun;Cha, Sung-Ho
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.9
    • /
    • pp.960-968
    • /
    • 2005
  • Purpose : This multi-center, open-label, clinical study was designed to evaluate the safety and immunogenicity of a trivalent, live, attenuated measles-mumps-rubella(MMR) vaccine, $Priorix^{TM}$ in Korean children. Methods : From July 2002 to February 2003, a total of 252 children, aged 12-15 months or 4-6 years, received $Priorix^{TM}$ at four centers : Han-il General Hospital, Kyunghee University Hospital, St. Paul's Hospital at the Catholic Medical College in Seoul, and Korea University Hospital in Ansan, Korea. Only subjects who fully met protocol requirements were included in the final analysis. The occurrence of local and systemic adverse events after vaccination was evaluated from diary cards and physical examination for 42 days after vaccination. Serum antibody levels were measured prior to and 42 days post-vaccination using IgG ELISA assays at GlaxoSmithKline Biologicals (GSK) in Belgium. Results : Of the 252 enrolled subjects, a total of 199 were included in the safety analysis, including 103 from the 12-15 month age group and 96 from the 4-6 year age group. The occurrence of local reactions related to the study drug was 10.1 percent, and the occurrence of systemic reactions was 6.5 percent. There were no episodes of aseptic meningitis or febrile convulsions, nor any other serious adverse reaction. In immunogenicity analysis, the seroconversion rate of previously seronegative subjects was 99 percent for measles, 93 percent for mumps and 100 percent for rubella. Both age groups showed similar seroconversion rates. The geometric mean titers achieved, 42 days pos-tvaccination, were : For measles, in the age group 12-15 months, 3,838.6 mIU/mL [3,304.47, 4,458.91]; in the age group 4-6 years, 1,886.2 mIU/mL [825.83, 4,308.26]. For mumps, in the age group 12-15 months, 956.3 U/mL [821.81, 1,112.71]; in the age group 4-6 years, 2,473.8 U/mL [1,518.94, 4,028.92]. For rubella, in the age group 12-15 months, 94.5 IU/mL [79.56, 112.28]; in the age group 4-6 years, 168.9 IU/mL [108.96, 261.90]. Conclusion : When Korean children in the age groups of 12-15 months or 4-6 years were vaccinated with GlaxoSmithKline Biologicals' live attenuated MMR vaccine ($Priorix^{TM}$), adverse events were limited to those generally expected with any live vaccine. $Priorix^{TM}$ demonstrated excellent immunogenicity in this population.