• 제목/요약/키워드: Multi-mode Optimum Design

검색결과 21건 처리시간 0.022초

사장교 케이블의 감쇠성능 향상을 위한 댐퍼의 비선형성 연구 (Study of the non-linearity of cable damper to enhance damping performance of stay cable)

  • 서주원;고현무
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.147-156
    • /
    • 2007
  • This study offers a design procedure of optimum cable damper for multi-mode vibration control with nonlinear damper and also investigate the relation between mode and amplitude dependency. The proposed multi-mode damping index, which is defined as a energy loss ratio of cable potential, is a main component of optimization problem of optimum nonlinear damper. In order to include the amplitude dependency of nonlinear damper, it is assumed to exist three kinds of multi-mode patterns such as ambient vibration, support excitation and rain-win induced vibration. The optimum damper exponent depends on amplitude patterns. In case of ambient vibration, optimum factor is less than 0.5. In case of support excitation or rain-wind induced vibration is between 0.5 and 1.0. In this study, the effects of cable sag and inclination angle are included in the asymptotic design equation of damped cable structures.

  • PDF

사장교 케이블의 감쇠성능 향상을 위한 댐퍼의 비선형성 연구 (Study of the Non-linearity of Cable Damper to Enhance Damping Performance of Stay Cable)

  • 서주원;고현무
    • 한국소음진동공학회논문집
    • /
    • 제17권9호
    • /
    • pp.785-796
    • /
    • 2007
  • This study offers a design procedure of optimum cable damper for multi-mode vibration control with nonlinear damper and also investigates the relation between mode and amplitude dependency. The proposed multi-mode damping index, which is defined as a potential energy loss ratio of cable vibration, is a main component of optimization problem of optimum nonlinear damper. In order to include the amplitude dependency of nonlinear damper, three types of multi-mode patterns such as ambient vibration, support excitation and rain-wind induced vibration are assumed. The optimum damper exponent depends on amplitude patterns. In case of ambient vibration, optimum factor is less than 0.5 and in case of support excitation or rain-wind induced vibration it is between 0.5 and 1.0.

광대역 다단 전력 분배기의 일반화된 설계 방법 (A General Design Method for the Broadband Multi-Section Power Divider)

  • 박준석;김형석;임재봉
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권2호
    • /
    • pp.85-91
    • /
    • 2002
  • A novel multi-section power divider configuration is Proposed to obtain wide-band frequency performance up to microwave frequency region. Design procedures for the proposed microwave broadband power divider are composed of a Planar multi-section three-Ports hybrid and a waveguide transformer design procedures. The multi∼section power divider is based on design theory of the optimum quarter- wave transformer Furthermore, in order to obtain the broadband isolation performance between the two adjacent output ports, the odd mode equivalent circuit should be matched by using the lossy element such as resistor. The derived design formula for calculating these odd mode∼matching elements is based on the singly terminated filter design theory. The waveguide transformer section is designed to suppress the propagation of the higher order modes such as waveguide modes due to employing the metallic electric wall. Simulation and experiment show excellent performance of multi section power divider.

마이크로파대 광대역 다단 전력분배기의 설계방법과 구조에 관한 연구 (A Study on the Design and Structure of A Microwave Broadband Multi-Section Power Divider)

  • 박준석;김형석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1829-1831
    • /
    • 2001
  • A novel multi-section power divider configuration is proposed to obtain wide-band frequency performance up to microwave frequency region. Design procedures for the proposed microwave broadband power divider are composed of a planar multi-section three-ports hybrid and a waveguide transformer design procedures. The multi-section power divider is based on design theory of the optimum quarter-wave transformer. Furthermore, in order to obtain the broadband isolation performance between the two adjacent output ports, the odd mode equivalent circuit should be matched by using the lossy element such as resistor. The derived design formula for calculating these odd mode matching elements is based on the singly terminated filter design theory. The waveguide transformer section is designed to suppress the propagation of the higher order modes such as waveguide modes due to employing the metallic electric wall. Simulation and experiment show excellent performance of multi section power divider.

  • PDF

다중 파괴모드를 고려한 단순 사면의 최적 설계 (Optimum Design of a Simple Slope considering Multi Failure Mode)

  • 김현기;신민호;최찬용
    • 한국방재학회 논문집
    • /
    • 제10권6호
    • /
    • pp.73-80
    • /
    • 2010
  • 최저 안전율 또는 최대 파괴확률을 기반으로 하는 기존의 사면안정해석에 대하여, 지반물성과 해석모델이 갖는 고유 불확실성을 최소화하고, 사면안정해석에서 다양한 안정해석모델과 그에 따른 파괴형상을 반영할 수 있도록, 다중 파괴모드를 고려한 사면의 신뢰성해석기법을 제안하였다. 파괴확률의 산정에는 체계 신뢰성해석분야에서 최근 도입된 선형계획법에 의한 최적화를 이용하였다. 이를 통하여 여러 가지 해석모델을 신뢰성 기반으로 동시에 고려하여 해석할 수 있다. 선형계획법에 의한 다중 파괴 모드를 고려한 파괴확률 산정기법을 이용하여 단순 사면의 경사도 결정을 위한 최적 설계를 검토하였다. 그 결과, 동시 파괴확률을 이용하면, 대상으로 하는 사면안정해석모델과 파괴형상 및 파괴확률을 복합적으로 고려할 수 있기 때문에 개선된 안전성을 확보할 수 있을 것으로 판단된다.

모세관을 이용한 멀티형 열펌프의 신뢰성에 관한 실험적 연구 (An Experimental Stuff on the Performance of Multi-type Heat Pump using Capillary Tubes)

  • 권영철;장근선;이윤수;김대훈;전용호;이상재
    • 설비공학논문집
    • /
    • 제14권9호
    • /
    • pp.749-755
    • /
    • 2002
  • In order to develop a multi-type heat pump system with two indoor units of non-uniform capacities, the optimum refrigerant circuit was developed using capillary tubes. The refrigerant circuit was composed of four main parts, a heating circuit, a cooling circuit, a by-pass circuit and a balance circuit. The system characteristics of multi-type heat pump was investigated through the rating test and the reliability test, using the multi-type psy-chrometric calorimeter. The results of the rating test showed that the capacity of the multi-type heat pump was about 93% of the design value. In particular, the capacity of cooling single mode was about 13% higher than the design value, and the capacity of heating multi mode was about 5% higher than the design value. The reliability of the multi-type heat pump was verified by various reliability tests (overload, extension tube, freeze up, under/over charging, sweat, flood back). The optimal amount of refrigerant charge and compressor capacity were determined from the present work.

마이크로파대 평면형 광대역 전력 분배기 설계 (Design of A Microwave Planar Broadband Power Divider)

  • 박준석;김형석;안달;강광용
    • 한국전자파학회논문지
    • /
    • 제12권4호
    • /
    • pp.651-658
    • /
    • 2001
  • 본 논문에서는 마이크로파대 광대역 다단 평면형 전력분배기의 설계방법과 구조를 새로이 제안하였다. 제시된 마이크로파 광대역 전력분배기의 설계과정은 평면형 다단 3-포트 하이브리드와 도파관트랜스포머 설계로 구성되었다. 다단 전력분배기는 최적화된 λ/4 트랜스포머 설계이론에 근거를 두고 있다. 두 인접 출력포드의 광대역 격리 특성을 얻기위해, 기모드 등기회로는 저항 같은 손실소자를 사용하여 정합되어야 한다. 기모드 정합소자 값을 계산하기 위한 설계공식은 단일 종단 여파기 설계이론으로부터 유도하였다. 도파관 트랜스포머단의 형상은 하우징 금속전계벽의 영향으로 인한 도파관 모드와 같은 고차모드의 전파를 억제하기 위해 설계되었다. 따라서, 설계된 각각의 도파관 트랜스포머단에서는 제안된 마이크로파 광대역 전력 분배기의 동작주파수 영역에서 모두 감쇄모드(evanescent mode)로 동작하여야 한다. 본 논문에서는 제안된 마이크로파 광대역 전력분배기의 검증을 위해, 다단 전력 분배기의 시뮬레이션과 실험 결과들을 제시하였다. 시뮬에이션과 실험 결과는 다단 전력분배기의 우수한 성능을 보여준다.

  • PDF

X-대역 4혼 삼중 모드 모노펄스 급전기 설계 (A Design on the Four-Horn Triple-Mode Type Monopulse Feeder at X-Band)

  • 김찬홍;김승각
    • 한국전자파학회논문지
    • /
    • 제21권5호
    • /
    • pp.528-536
    • /
    • 2010
  • 모노펄스 급전기는 공간 급전 방식을 사용하는 다기능 레이더 또는 추적 레이더의 복사 패턴 특성에 가장 큰 영향을 미친다. 세 개의 모노펄스 채널에 대해 최적 개구면 분포를 가지는 삼중 모드 방식 모노펄스 급전기의 설계 및 측정 결과에 관해 본 논문에 기술하였다. 측정 결과 설계 및 제작된 급전기는 최적 개구면 분포 특성을 만족할 뿐만 아니라 X-대역의 10 % 대역폭에서 매우 낮은 반사 손실 특성을 보였다. 급전기의 이러한 특성은 적용될 안테나가 저부엽 특성과 높은 모노펄스 기울기 특성을 보유함을 의미한다.

적분형 최적 레귤레이터 적용 시스템 히트펌프 제어 시뮬레이션 연구 (Numerical Simulation of a System Heat Pump Adopting an Integral Optimum Regulating Controller)

  • 김용찬;최종민
    • 설비공학논문집
    • /
    • 제25권7호
    • /
    • pp.398-405
    • /
    • 2013
  • Small and medium-size buildings employ a multi-distributed individual air-conditioning system that utilizes package air conditioners instead of centralized cooling systems, which can allow easier building management and maintenance, along with a diversification of facility use. Inverter driven system heat pumps have been developed to achieve not only an easy distribution control, allowing free combination of indoor units with different models and different capacities, but also wide applications to intelligent air conditioning. However, the control algorithms of the system heat pump are limited in the open literature, due to complicated operating conditions. In this paper, an inverter-driven system heat pump having two indoor units with electronic expansion valves (EEV) was simulated in the cooling mode. An integral optimum regulating controller employing the state space control method was also simulated, and applied to the system-heat pump system, to obtain efficient control of the MIMO (multi input multi output) system. The simulation model for the controller yielded satisfactory prediction results. The new control model can be successfully utilized as a basic tool in controller design.

유한요소해석 시뮬레이션을 이용한 평판형 $L_{1}-B){8}$ 모드 초음파 전동기의 최적 설계 (An Optimum Design of Flat-type $L_{1}-B){8}$ Mode Ultrasonic Motors Using FEM Simulation)

  • 우상호;김우태;신순인;김진수;사정우;김기수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.664-667
    • /
    • 2001
  • A flat-type L$_1$-B$_{8}$ Mode Ultrasonic motor(USM) uses longitudinal-bending multi-mode vibrator which is constructed with the metal-piezoceramic composite thin plate vibrator. Especially, the characteristics of vibrating displacement of the vibrator are important for the fabrication of USM. So, in this study, we tried to analyze them by the FEM(finite element method) simulation program. ANSYS 5.6 we used is a finite element software enabling the analysis of 2 or 3 dimensional structure of piezoelectric materials. Using this made us analyzing the resonance frequency and calculating displacement of vibrator and then the position of the projection.n.

  • PDF