• 제목/요약/키워드: Multi-floor

검색결과 339건 처리시간 0.028초

충청지역 공중화장실 내 다목적화장실의 평면유형과 공간구성에 관한 연구 (A Study on the floor Plan Types and the Space Composition of Multi-used Toilets In Public-Toilets of Choongchung-Do)

  • 김은중
    • 한국실내디자인학회논문집
    • /
    • 제15권1호
    • /
    • pp.139-146
    • /
    • 2006
  • This study shows the floor plan types and the space composition of multi-used toilets in public-toilets of Choongchung-Do. The areas of multi-used toilets are various from 4.8m2 to 10.5m2 And there Is usually one multi-used toilet in one public-toilet, but some public-toilets have two multi-used toilets. Multi-used toilets have several equipments such as toilet stool, urinal, washstand, change diaper, chair for baby-care, toilet stool for child, urinal for child, so on. All the multi-used toilets have toilet stool and washstand, but urinal and change diaper were used restrictively, and chair for baby-care, toilet stool for child, urinal for child were used in few cases. There are six types how the multi-used toilets are located in public-toilets, five types of multi-used toilet forms, and five types how the equipments are installed in multi-used toilets. The dotted blocks are installed partially in line type, and partially in spot type. But some cases, there was no installation of dotted block. Auto-sliding door were usually applicated, and some other types of door system were used restrictively. This study offers not only the present conditions, but also the appropriate planning directions of the multi-used toilets.

다기능온돌시스템을 이용한 자연환기성능 평가 (Evaluation of Natural Ventilation Performance using the Multi-Functional Floor Heating System)

  • 조동우;유기형;유정연;정해권
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.105-112
    • /
    • 2007
  • Recently developed raised floor heating system is not only capable of basic function to reduce noise between floors, but also is a multi-functional floor heating system enabling natural ventilation. The procedure of this system for natural ventilation is to import outdoor air through bottom space of the floor heating system, circulate indoor space and discharge it out of ceiling. In winter, powerless natural ventilation is possible with buoyancy effect caused by temperature difference between outdoor and indoor. And it also allows saving of energy by importing pre-heated air in bottom space of the floor heating system. To evaluate ventilation performance of this system, on-site measurement was conducted in 2 test laboratories, and the nominal air change rate was satisfied as 0.4$\sim$0.8 h-1 under the condition of outdoor temperature $5^{\circ}C{\sim}-5^{\circ}C$, which was evaluated as highly possible to be applied as a natural ventilation system in multi-family houses.

  • PDF

완충재의 구성에 따른 동탄성계수 변화에 관한 연구 (A Study on Dynamic Stiffness of Multi-layered Damping Materials)

  • 임정빈;정진연;김경우;정갑철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1149-1152
    • /
    • 2007
  • Many kind of damping materials are generally used on concrete slab in apartment building to reduce floor impact noise level. Lately, multi-layered damping material that is consist of several materials are used to improve the effect of floor impact noise insulation. In this study, dynamic stiffness of multi-layered damping material that is consist of common materials such as expanded polystyrene(EPS), expended polyethylene(EPE), ethylene vinyl acetate(EVA) and polyester was investigated. It was found that dynamic stiffness of multi-layered damping material could be estimated if know value of each layer that compose whole structure. And it was found that dynamic stiffness of whole structure did not change even if change order that build layer.

  • PDF

중국 연변 조선족과 한족피 집합주택 평면구성 비교 연구 - 연길시를 중심으로 - (The Comparison of Space Origination between Korean-Chinese and Chinese Multi-family Housing in China)

  • 김종영
    • 한국주거학회논문집
    • /
    • 제15권4호
    • /
    • pp.55-63
    • /
    • 2004
  • The aims of this research are to find the difference of space origination between Korean-Chinese and Chinese multi-family housing unit plan and to find the main reason to make this difference. To do this research, twenty three different kinds of floor plans were surveyed and examined. The results are as follows; 1. The Chinese-Korean floor plan and Chinese floor plan in Ondol heating system are totally different, although in radiator and floor panel heating system are similar. The inner space origination between two races are different. That is to say, Chinese-Korean likes open space origination and Chinese likes closed space origination. 2. The main reasons to make differences seem to be living style, heating system, constructional method and the trade with South Korea. In the future time, the usage of floor panel heating system will be increased and various kinds of floor plan should be introduced.

천공 다층 복합 바닥재의 모델링 및 성능평가 (Modeling and Performance Evaluation of Multi-layer Composite Floor Plates with Holes)

  • 유홍희;이창근;유홍걸;주영준;조정은
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.665-670
    • /
    • 2002
  • Pleasantness or quietness becomes one of the most important factors for residential designs recently. Especially for apartments, the noise generated by falling objects becomes a sensitive issue these days. To overcome the problem of the impact noise in apartments, the floor design has been changed. To reduce the transmissibility of the noise, composite floor structures are devised and implemented for the construction of apartments. In this paper, the noise reduction performance of a composite floor plate with holes is analyzed. Computational modelings for the structures are developed and its performance is evaluated by using the finite element method. The results show that the noise can be well reduced with the multi-layer composite floor plates with holes.

  • PDF

공동주택 공기열 멀티 히트펌프의 바닥난방 성능 평가 (Performance Evaluation of Air Source Multi Heat Pump Floor Heating System in Apartment)

  • 이철희;나환선;정훈;김강식
    • 한국기계기술학회지
    • /
    • 제13권3호
    • /
    • pp.93-98
    • /
    • 2011
  • To analyze and evaluate the performance of developing air to water multi heat pump, the heat pump was installed and tested at low energy house in Daejeon, korea. Heating capacity of heat pump is 16.5KW and cooling capacity is 14.0KW. Space heating/cooling, floor heating and hot water is available. The results performance evaluation of heat pump in lab test showed that the coefficient of performance (cop) was 3.75, and heating capacity was 16.0KW in ambient temperature $7^{\circ}C$. Also at ambient temperature $-15^{\circ}C$, the COP was 1.69. At a low energy house, floor heating is controled by a floor heating water temperature and a room temperature. The COP of heat pump is decreased with frequent on/off operation for controlling of floor heating water temperature.

다중세션 공동저작 환경에서의 충돌 없는 객체 공유를 위한 대표의장 방식의 플로어 제어 (The Chair-of-Chair-Guided Floor Control for Sharing Objects without Collision in a Multi-Session Collaborative Authoring Environment)

  • 신성운;오삼권
    • 정보처리학회논문지A
    • /
    • 제12A권5호
    • /
    • pp.433-440
    • /
    • 2005
  • 많은 저작자들이 협력하여 작업을 수행할 수 있는 공동저작 시스템에서는 저작을 위해 객체들을 공유하는 일들이 참여 저작자들 간에 빈번히 발생한다. 따라서 객체 액세스를 위한 경쟁을 최소화하고 객체들의 배타적 사용을 보장해 주는 플로어 제어가 필요하다. 플로어(floor)란 공동저작 참여자에게 부여되는 한 공유자원에 대한 임시 사용 권한이다 단일세션 환경을 위한 플로어 제어 기법들은 여러 문헌에서 찾아 볼 수 있으나 다중세션 환경을 위한 기법들은 거의 찾아 볼 수가 없다. 다중 세션 환경에서는 한 객체가 여러 세션에서 동시에 공유될 수 있다. 본 논문은 다중 세션 환경에서의 객체 공유로 인한 문제들의 해결을 위해 대표의장(chair-of-chair) 방식의 플로어 제어 기법을 제안한다. 기존의 의장형 방식을 확장한 이 방식에는 세션 의장들 중에서 선출된 대표의장이 존재한다.

최적화 기법을 이용한 LNG FPSO 액화 공정 장비의 다층 배치 (Multi-floor Layout for the Liquefaction Process Systems of LNG FPSO Using the Optimization Technique)

  • 구남국;이준채;노명일;황지현;이규열
    • 대한조선학회논문집
    • /
    • 제49권1호
    • /
    • pp.68-78
    • /
    • 2012
  • A layout of an LNG FPSO should be elaborately determined as compared with that of an onshore plant because many topside process systems are installed on the limited area; the deck of the LNG FPSO. Especially, the layout should be made as multi-deck, not single-deck and have a minimum area. In this study, a multi-floor layout for the liquefaction process, the dual mixed refrigerant(DMR) cycle, of LNG FPSO was determined by using the optimization technique. For this, an optimization problem for the multi-floor layout was mathematically formulated. The problem consists of 589 design variables representing the positions of topside process systems, 125 equality constraints and 2,315 inequality constraints representing limitations on the layout of them, and an objective function representing the total layout cost. To solve the problem, a hybrid optimization method that consists of the genetic algorithm(GA) and sequential quadratic programming(SQP) was used in this study. As a result, we can obtain a multi-floor layout for the liquefaction process of the LNG FPSO which satisfies all constraints related to limitations on the layout.

Analytical solution for free vibration of multi-span continuous anisotropic plates by the perturbation method

  • Liu, Jiepeng;Cao, Liang;Chen, Y. Frank
    • Structural Engineering and Mechanics
    • /
    • 제69권3호
    • /
    • pp.283-291
    • /
    • 2019
  • Accurately determining the natural frequencies and mode shapes of a structural floor is an essential step to assess the floor's human-induced vibration serviceability. In the theoretical analysis, the prestressed concrete floor can be idealized as a multi-span continuous anisotropic plate. This paper presents a new analytical approach to determine the natural frequencies and mode shapes of a multi-span continuous orthotropic plate. The suggested approach is based on the combined modal and perturbation method, which differs from other approaches as it decomposes the admissible functions defining the mode shapes by considering the intermodal coupling. The implementation of this technique is simple, requiring no tedious mathematical calculations. The perturbation solution is validated with the numerical results.

Simulation for Shop Floor Control

  • Cho, Hyunbo
    • 한국시뮬레이션학회:학술대회논문집
    • /
    • 한국시뮬레이션학회 1996년도 춘계학술대회
    • /
    • pp.15-15
    • /
    • 1996
  • A shop floor control system (SFCS) is the central part of a CIM system used to control the activities of several pieces of manufacturing equipment (e.g., NC machines, robots, conveyors, AGVs, AS/RS). The SFCS receives orders and related process plans, and then performs selecting a specific process routing, allocating resources, scheduling the workpieces, downloading the processing instructions (e.g., RS-274 instructions for NC machines, VAL II programs for robot), monitoring the progress of activities, detecting and recovering from errors, and preparing reports on the status of the manufacturing system. Simulation has been utilized in discovering control policies used for resolving shop floor be control problems such as resource contentions, part dispatching, deadlock. The simulation model must be designed to respond to real-time data coming from a shop floor. However, to rapidly build a realtime simulation model of SFCS cannot be easily accomplished. This talk is to address an automatic program generator of discrete event simulation model for shop floor control from process plans and resource models. The program generator is capable of constructing complete discrete simulation models for multi-product and multi-stage flexible manufacturing systems.

  • PDF