• Title/Summary/Keyword: Multi-dividing

Search Result 155, Processing Time 0.034 seconds

A study on the speech recognition by HMM based on multi-observation sequence (다중 관측열을 토대로한 HMM에 의한 음성 인식에 관한 연구)

  • 정의봉
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.4
    • /
    • pp.57-65
    • /
    • 1997
  • The purpose of this paper is to propose the HMM (hidden markov model) based on multi-observation sequence for the isolated word recognition. The proosed model generates the codebook of MSVQ by dividing each word into several sections followed by dividing training data into several sections. Then, we are to obtain the sequential value of multi-observation per each section by weighting the vectors of distance form lower values to higher ones. Thereafter, this the sequential with high probability value while in recognition. 146 DDD area names are selected as the vocabularies for the target recognition, and 10LPC cepstrum coefficients are used as the feature parameters. Besides the speech recognition experiments by way of the proposed model, for the comparison with it, the experiments by DP, MSVQ, and genral HMM are made with the same data under the same condition. The experiment results have shown that HMM based on multi-observation sequence proposed in this paper is proved superior to any other methods such as the ones using DP, MSVQ and general HMM models in recognition rate and time.

  • PDF

The Analysis For Reliability In Multi-dividing Multi-connecting High Power Distribution System (배전계통 연계에 따른 신뢰도 향상 분석)

  • Cho, Nam-Hun;Ha, Bok-Nam;Kang, Moon-Ho;Lee, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.316-318
    • /
    • 2001
  • Occasionally, equipment in a distribution system fails due to damage from weather, vandalism, or other causes. In addition, it is recommended practice to have some way in which maintenance or replacement of every element in a system can be performed without causing lengthy interruption of electrical service to the customers it feeds. Thus, alternate sources, paths, and configurations of service must be planned so that both failures and maintenance do not affect customer service beyond a reasonable amount. In some cases, planning for alternate routes of service during equipment outages or emergencies -- will be the major aspect influencing selection of a feeder's capacity, type of route, or layout. We want to know the relationship between molt-dividing multi-connection and distribution reliability for contingency support considerations.

  • PDF

The Optimal Number of Dividing and Connecting Per Feeder in Korea Distribution System (국내 배편계통의 최적 연계(안))

  • Jo, Nam-Hun;Kim, Geon-Jung;Kim, Jae-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.7
    • /
    • pp.349-361
    • /
    • 2002
  • Occasionally, equipment in a distribution system fails due to damage from weather, vandalism, or other causes. Failures and unexpected events do not always occur as and where expected. Therefore, a good contingency plan, multi-zone or otherwise, provides flexibility by locating switches at various strategic locations so that parts of a feeder can be picked up in the event of line outages at various places. It is possible to create feeder system layout that achieve remarkable contingency support economics, even as their normal peak loading levels approach thermal capacity, by utilizing six, seven, or even nine switchable zones per feeder. But many switchable zones per feeder are of questionable practicality and effectiveness, because of the complexity and time required for the switching operation. In practice, a zonal scheme with between three and four zones will usually provide complete contingency backup for all feeders. Line switches have both capital and maintenance costs, the planning for multi-zonal schemes is considerably more difficult than or loop or single-zone systems, and the required switching operations required during contingencies take more time. But multi-zonal schemes are used because these costs come to far less than the cost of additional capacity required for loop or single-zone. In this paper, we present the optimal number of switchable zones per feeder in Kora distribution system.

Improvement of Efficiency about $TiO_2$ Layer Multi-dividing Effect in Dye-sensitized Solar Cell (염료감응형 태양전지의 $TiO_2$ Layer 다분할 효과에 따른 효율 향상 연구)

  • Son, Min-Kyu;Seo, Hyun-Woong;Lee, Kyoung-Jun;Hong, Ji-Tae;Kim, Hee-Je
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.425-427
    • /
    • 2008
  • Active area of dye-sensitized solar cell (DSSC) has an effect on the efficiency of DSSC. As the active area increases, the efficiency goes down in a general way. This is caused by the increase of internal resistance in DSSC. The internal resistances are related to various resistant elements. The charge transfer processes at Pt counter electrode and the sheet resistance of TCO are two of these resistant elements. In this study, we try to divide the active area into several small sections in a large sized cell to reduce these two internal resistant elements. As a result, we find out that the fill factor is increased and then the conversion efficiency is improved as the number of dividing active area into several small sections is increased.

  • PDF

A Clock Regenerator using Two 2nd Order Sigma-Delta Modulators for Wide Range of Dividing Ratio

  • Oh, Seung-Wuk;Kim, Sang-Ho;Im, Sang-Soon;Ahn, Yong-Sung;Kang, Jin-Ku
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.1
    • /
    • pp.10-17
    • /
    • 2012
  • This paper presents a clock regenerator using two $2^{nd}$ order ${\sum}-{\Delta}$ (sigma-delta) modulators for wide range of dividing ratio as defined in HDMI standard. The proposed circuit adopts a fractional-N frequency synthesis architecture for PLL-based clock regeneration. By converting the integer and decimal part of the N and CTS values in HDMI format and processing separately at two different ${\sum}-{\Delta}$ modulators, the proposed circuit covers a very wide range of the dividing ratio as HDMI standard. The circuit is fabricated using 0.18 ${\mu}m$ CMOS and shows 13 mW power consumption with an on-chip loop filter implementation.

Free Vibration of Compressed Laminated Composite Beam-Columns with Multiple Delaminations (압축하중을 받는 다층간분리 적층 복합 보-기둥의 자유진동)

  • 이성희;박대효;백재욱;한병기
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.10a
    • /
    • pp.501-508
    • /
    • 2001
  • Free vibration analysis of multi-delaminated composite beam-columns subjected to axial compression load is performed in the present study. In order to investigate the effects of multi-delaminations on the natural frequency and elastic buckling load of multi-delaminated beam-columns, the general kinematic continuity conditions are derived from the assumption of constant slope and curvature at the multi-delamination tip. Characteristic equation of multi-delaminated beam-column is obtained by dividing the global multi-delaminated beam-columns into segments and by imposing recurrence relation from the continuity conditions on each sub-beam-column. The natural frequency and elastic buckling load of multi-delaminated beam-columns according to the incremental load of axial compression, which is limited to the maximum elastic buckling load of sound laminated beam-column, are obtained. It is found that the sizes, locations and numbers of multi-delaminations have significant effect on natural frequency and elastic buckling load, especially the latter ones.

  • PDF

New Double-Connected Multi-Step Inverter for SVC (SVC를 위한 새로운 이중접속방식의 멀티스텝 인버터)

  • 최세완;양승욱;김기용
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.460-463
    • /
    • 1999
  • A new multi-step voltage source inverter is proposed in this paper. The proposed scheme is composed of the double-connected 12-step inverter with an auxiliary circuit. The auxiliary circuit includes two voltage dividing capacitors, two switching devices and a low KVA autotransformer. The resultant system is shown to be a 24-step inverter suitable for large scale SVC applications in which the PWM method can not be employed. The design parameters are derived from the analysis of voltages and currents by means of switching functions. The simulation results verify the proposed concept.

  • PDF

The Standard for Installation of Automated Distribution Switch-gear in Multi-Line Faults (다중선로 고장을 고려한 배전자동화용 개폐기 설치기준)

  • Lee, Jung-Ho;Ha, Bok-Nam;Cho, Nam-Hun;Lim, Sung-Il
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1079-1081
    • /
    • 1999
  • This paper presents the standard for dividing/tieing the distribution lines and installing optimally the automated distribution switch-gear in multi-line faults. Also this paper recommends the distribution system design in consideration of the live load transfer of the concentrated load in the last load-side. This recommendation will be useful for designing the distribution network, developing the feeder automation software and operating the distribution automation system.

  • PDF

Multi-Operand Radix-2 Signed-Digit Adder using Current Mode MOSEET Circuits

  • Sakamoto, Masahiro;Hamano, Daisuke;Higuchi, Yuuichi;Kiriya, Takechika;Morisue, Mititada
    • Proceedings of the IEEK Conference
    • /
    • 2000.07a
    • /
    • pp.167-170
    • /
    • 2000
  • This paper describes a novel multi-operand radix-2 signed-digit(SD) adder. The novel multi-operand addition algorithm can eliminate carry propagation chain by dividing the input operands into even place part and odd place part, and adding them each. The multi-operand adder with this algorithm can add six operands in parallel, and is faster than the ordinary method of SD adder binary tree. A hardware model for proposed adder is shown which is implemented by the current-mode MOSFET circuit technology. Simulations have been made by SPICE in order to verify the function of the proposed circuit.

  • PDF

Multi-Time Scale Separations and Optimal Control Problems of Multi-Parameter Singular Perturbation Systems (여러 매개상수 특이접동계에서의 여러 시간스케일 분리와 최적제어 문제)

  • Kim, Sam-Soo;Hong, Jae-Keun;Kim, Soo-Joong
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.1
    • /
    • pp.20-27
    • /
    • 1987
  • The hierarchical approach method is proposed to sperate each different time scale sub-systems from linear time invariant multi-parameter singular perturbation systems. By means of this proposal, the original multi-parameter singular perturbation systems is completely separated into independent subsystems with each different time scale. It is also investigated that the controllability of the system is invariant. And this paper applies singular perturbation methods to the minimum control effort problem for linear time invariant systems with constrained controls. Also near-optimum control theory, which is based on dividing the total time interval with the time scales respectively, is proposed. As a result, the time scale separation method is show to be particularly useful in a near optimum design which can be otained through a decentralized control structure.

  • PDF