• Title/Summary/Keyword: Multi-coupled

Search Result 736, Processing Time 0.02 seconds

Directions for Muti-institutional Cooperation in Follow-up Management of Prostatic Disease Screening for the Low-income Group in Gangwon-do (강원도 저소득층의 전립선질환 검진사업과 사후관리를 위한 유관기관 협력방안)

  • Jang, Sungok;Lee, Jongseok
    • Korean Journal of Health Education and Promotion
    • /
    • v.30 no.4
    • /
    • pp.99-110
    • /
    • 2013
  • Objectives: This study aimed to investigate factors related to prostate disease and follow-up procedure on health examination program in Gangwon-do. Methods: The studied population was 16,501 male aged 40 or more, who underwent screening tests for prostatic disease in 2011 health examination program designed for the low income residents in Gangwon-do. The screening tests included prostate specific antigen (PSA), international symptom score (IPSS), and maximal flow rate (Qmax). We conducted chi-square test for trend, two independent samples t-test, and binary logistic regression to find out the relationship between prostate cancer or benign prostatic hyperplasia and risk factors such as age, PSA level, and IPSS. Results: The number of subjects who turned out positive for PSA level (> 3.8ng/ml) was 971 men accounting for 5.9%. The result of post survey on them showed that 511 subjects (52.6%) got the urology check-up: 156 (30.5%) were diagnosed as normal, 286 (56.0%) as benign prostatic hyperplasia, and 69 (13.5%) as prostate cancer. The detection rate for prostate cancer was 8.8% when PSA level was between 3.81 and 9.99g/ml, and was 30.6% when PSA level was more than 10.00ng/ml. The rates of further testing varied depending on the communities from 26.7% to 68.2%, which was mainly affected by the role of local health center. Conclusions: Our findings indicate that enhanced quality control of local health center and empowerment of screening agency would increase the effort of coupled institutions between public and private sectors.

Vertical Growth of CNTs by Bias-assisted ICPHFCVD and their Field Emission Properties (DC Bias가 인가된 ICPHFCVD를 이용한 탄소나노튜브의 수직 배향과 전계방출 특성)

  • Kim, Kwang-Sik;Ryu, Ho-Jin;Jang, Gun-Eik
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.2
    • /
    • pp.171-177
    • /
    • 2002
  • In this study, the vertical aligned carbon nanotubes was synthesized by DC bias-assisted Inductively Coupled Plasma Hot-Filament Chemical Vapor Deposition (ICPHFCVD). The substrate used CNTs growth was Ni(300 ${\AA}$)/Cr(200 ${\AA}$)-deposited one on glass by RF magnetron sputtering. R-F, DC bias and filament power during the growth process were 150 W, 80 W, 7∼8 A, respectively. The grown CNTs showed hollow structure and multi-wall CNTs. The top of grown CNT was found to Ni-tip that the CNT end showed to metaltip. The graphitization and field emission properties of grown was better than grown CNTs by ICPCVD. The turn-on voltage of CNT grown by DC bias-assisted ICPHFCVD showed about 3 V/${\mu}m$.

Daily Stock Price Forecasting Using Deep Neural Network Model (심층 신경회로망 모델을 이용한 일별 주가 예측)

  • Hwang, Heesoo
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.6
    • /
    • pp.39-44
    • /
    • 2018
  • The application of deep neural networks to finance has received a great deal of attention from researchers because no assumption about a suitable mathematical model has to be made prior to forecasting and they are capable of extracting useful information from large sets of data, which is required to describe nonlinear input-output relations of financial time series. The paper presents a new deep neural network model where single layered autoencoder and 4 layered neural network are serially coupled for stock price forecasting. The autoencoder extracts deep features, which are fed into multi-layer neural networks to predict the next day's stock closing prices. The proposed deep neural network is progressively learned layer by layer ahead of the final learning of the total network. The proposed model to predict daily close prices of KOrea composite Stock Price Index (KOSPI) is built, and its performance is demonstrated.

Review on the buoyancy effect of the multi purpose double-deck tunnels during operation (운영중 다목적 복층터널의 부력영향 검토)

  • Kim, Ho-jong;Kim, Hyeon-ah;Joo, Eun-jung;Shin, Jong-ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.6
    • /
    • pp.623-635
    • /
    • 2015
  • Double-deck tunnels beneath the groundwater table have relatively large volume and commonly constructed as watertight tunnels. In this case, it requires to secure stability of the tunnels for buoyant force. Generally the contact force between lining and ground is sufficient to resist the buoyant force. However in the long-term the contact force could be reduced because of structural deterioration. In this study the effect of long-term buoyant force acting on the double-deck tunnel is investigated. The results has shown that the buoyant force has increased invert deformation and stress. It is indicated that the contact resilience between lining and ground needs to be kept during tunnel operation.

Influence of the stiffness of Vertical Joints on the Behaviour of Precast Shear Walls. Part1. Load Case 1 (연직접합(鉛直接合)의 강성(剛性)이 프리케스트 전단벽(剪斷壁)의 구조적거동(構造的擧動)에 미치는 영향(影響) I. 하중조합(荷重組合) 1에 대하여)

  • Park, Kyung-Ho
    • Journal of Industrial Technology
    • /
    • v.3
    • /
    • pp.103-116
    • /
    • 1983
  • Recent developments in multi-storey buildings for residential purpose have led to the extensive use of shear walls for the basic structural system. When the coupled shear wall system is used, joined together with cast-in-place concrete or mortar (or grout), the function of the continuous joints is a crucial factor in determining the safety of L.P. Precast concrete shear wall structures, because the function of the continuous joints(Vertical wall to wall joints) is to transfer froces from one element(shear wall panel) to another, and if sufficient strength and ductility is not developed in the continuous joints, the available strength in the adjoining elements may not be fully utilized. In this paper, the influence of the stiffness of vertical joints(wet vertical keyed shear joints) on the behaviour of precast shear walls is theoretically investigated. To define how the stiffness of the vertical joints affect the load carrying capacity of L.P.Precast concrete shear wall structure, the L.P.Precast concrete shear wall structure is analyzed, with the stiffness of the vertical joints varying from $K=0.07kg/mm^3$(50MN/m/m) to $K=1.43kg/mm^3$(1000MN/m/m), by using the continuous connection method. The results of the analysis shows that at the low values of the vertical stiffness, i.e. from $K=0.07kg/mm^3$(50MN/m/m) to $K=0.57kg/mm^3$(400MN/m/m), the resisting bending moment and shearing force of precast shear walls, the resisting shearing force of vertical joints and connecting beams are significantly affected. The detailed results of analysis are represented in the following figures and Tables.

  • PDF

A New Hybrid Method for Nonlinear Soil-Structure Interaction Analysis (비선형 지반-구조물 상호작용해석을 위한 새로운 복합법)

  • 김재민;최준성;이종세
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.6
    • /
    • pp.1-7
    • /
    • 2003
  • This paper presents a novel hybrid time-frequency-domain method for nonlinear soil-structure interaction(SSI) analysis. It employs, in a practical manner, a computer code for equivalent linear SSI analysis and a general-purpose nonlinear finite element program. The proposed method first (calculates dynamic responses on a truncated finite element boundary utilizing an equivalent linear SSI program in the frequency domain. Then, a general purpose nonlinear finite element program is employed to analyze the nonlinear SSI problem in the time domain, in which boundary conditions at the truncated boundary are imposed with the responses calculated in the previous frequency domain SSI analysis, In order to validate the proposed method, seismic response analyses are carried out for a 2-D underground subway station in a multi-layered half-space, For the analyses, a equivalent linear SSI code KIESSI-2D is coupled to ANSYS program. The numerical results indicate that the proposed methodology can be a viable solution for nonlinear SSI problems.

Review of Magnetocardiography Technology based on SQUIDs (SQUID를 이용한 심자도 기술의 개발동향)

  • Lee, Y.H.;Kwon, H.;Kim, J.M.;Kim, K.;Yu, K.K.;Park, Y.K.
    • Progress in Superconductivity
    • /
    • v.13 no.3
    • /
    • pp.139-145
    • /
    • 2012
  • Electric activity of cardiac muscles generates magnetic fields. Magnetocardiography (or MCG) technology, measuring these magnetic signals, can provide useful information for the diagnosis of heart diseases. It is already about 40 years ago that the first measurement of MCG signals was done by D. Cohen using SQUID (superconducting quantum interference device) sensor inside a magnetically shielded room. In the early period of MCG history, bulky point-contact RF-SQUID was used as the magnetic sensor. Thanks to the development of Nb-based Josephson junction technology in mid 1980s and new design of tightly-coupled DC-SQUID, low-noise SQUID sensors could be developed in late 1980s. In around 1990, several groups developed multi-channel MCG systems and started clinical study. However, it is quite recent years that the true usefulness of MCG was verified in clinical practice, for example, in the diagnosis of coronary artery disease. For the practical MCG system, technical elements of MCG system should be optimized in terms of performance, fabrication cost and operation cost. In this review, development history, technical issue, and future development direction of MCG technology are described.

The Design of 2.4 GHz Band LTCC Bandpass Filter using $\lambda$/4 Hairpin Resonators ($\lambda$/4 Hairpin 공진기를 이용한 2.4 GHz 대역 LTCC 대역통과 필터의 설계)

  • Sung Gyu-Je
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.11 no.4 s.33
    • /
    • pp.7-11
    • /
    • 2004
  • In this paper, a $\lambda$/4 hairpin resonator is applied to reduce the size of planar resonators for a 2.4 GHz Band LTCC MLC bandpass filter. The $\lambda$/4 hairpin resonator operates as stepped impedance resonator (SIR) without changing the width of the planar resonator. It is composed of two sections those are parallel coupled line and transmission line. The characteristic impedance of two sections is different each other. The design formulas of the bandpass filter using the coupling element at the arbitrary position are derived from even and odd-mode analysis. The formulas can take account of the arbitrary coupling of lumped and/or distributed resonators. The advantage of this filter is its abilities to change freely the coupling structure between two resonators. Experimental bandpass filters for 2.4 GHz Band are implemented and their performances are shown.

  • PDF

Influence of Soil Characteristic and Rainfall Intensity on Matric Suction of Unsaturated Weathered Soil Slope (불포화 풍화토 사면의 모관흡수력 분포에 대한 지반조건과 강우강도의 영향)

  • Kim, Yong Min;Lee, Kwang Woo;Kim, Jung Hwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.1017-1025
    • /
    • 2013
  • The monolithically coupled finite element analysis for a deformable unsaturated soil slope is performed to investigate matric suction distribution on a soil slope subjected to rainfall infiltration, which can consider the hydraulic-mechanical characteristics for the analysis. The soil-water characteristic curves (SWCC) are experimentally determined to estimate three types of hydraulic properties of domestic areas. Based on the physical properties, the distribution of matric suction is investigated by considering the major factors, such as soil conditions, rainfall intensities, and slope angles. It is found from the results of this study that the matric suction rapidly decreases with an increase in rainfall intensity, regardless a slope angle. The slope surface is more easily saturated when its saturated hydraulic conductivity is smaller than rainfall intensity, and for the case of multi-layered soil slope, hydraulic characteristics of slope surface has a significant influence on matric suction distribution.

A Study on the Variation of Electric Contact Resistance Due to Change in Contact Force in a Tin-plated Connector (주석 도금한 커넥터의 접촉 하중의 변화에 의한 전기 접촉저항 변화에 관한 연구)

  • Yu, Hwan-Shin;Oh, Man-Jin;Park, Hyung-Bae
    • Journal of Advanced Navigation Technology
    • /
    • v.18 no.4
    • /
    • pp.381-386
    • /
    • 2014
  • In order to investigate the effect of contact load, which is one of the fretting corrosion factors affecting the electric connector, a coupled fretting corrosion specimens were prepared using a tin-plated brass coupon with a thickness of $3{\mu}m$. Electric resistance of the contact was measured during the fretting corrosion test period. There was increase in resistance with fretting cycles. The change in resistance can be classified by 3 stages. The first stage exhibited low and stable resistance. Second stage showed steady increment of the resistance and third stage showed very high and intermittent resistance. The relationship between the failure cycle (Nf) and contact force (P) can be drawn as; It is possible to draw the prediction equation for the failure cycle of the electric connector corresponding to the very high and intermittent resistance under various environment conditions through the fretting tests under various conditions such as load, displacement, temperature.