• Title/Summary/Keyword: Multi-Story Structure

Search Result 145, Processing Time 0.023 seconds

High-rise Reinforced-concrete Building Incorporating an Oil Damper in an Outrigger Frame and Its Vibration Analysis

  • Omika, Yukihiro;Koshika, Norihide;Yamamoto, Yukimasa;Kawano, Kenichi;Shimizu, Kan
    • International Journal of High-Rise Buildings
    • /
    • v.5 no.1
    • /
    • pp.43-50
    • /
    • 2016
  • The reinforced-concrete multi-story shear-wall structure, which can free a building from beams and columns to allow the planning of a vast room, has increasingly been used in Japan as a high-rise reinforced-concrete structure. Since this structural system concentrates the seismic force onto multi-story shear walls inside, the bending deformation of the walls may cause excessive deformation on the upper floors during an earthquake. However, it is possible to control the bending deformation to within a certain level by setting high-strength and rigid beams (outriggers) at the top of the multi-story shear walls; these outriggers restrain the bending behavior of the walls. Moreover, it is possible to achieve high energy dissipation by placing vibration control devices on the outriggers and thus restrain the bending behavior. This paper outlines the earthquake response analysis of a high-rise residential tower to demonstrate the effectiveness of the outrigger frame incorporating vibration control devices.

A Study on the Vibration Control of Multi-story Structure Using Neural Network Predictive Control System (신경회로망 예측 제어시스템을 이용한 다층 구조물의 진동제어에 관한 연구)

  • 조현철;이진우;이영진;이권순
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1998.10a
    • /
    • pp.324-329
    • /
    • 1998
  • In this paper, neural networks predictive PID (NNPPID) control system is proposed to reduce the vibration of structure. NNPPID control system is made up predictor, controller, and self-tuner to yield the optimal parameters of controller. The neural networks predictor forecasts the future outputs based on present input and output of structure. The controller is PID type whose parameters are yielded by neural networks self tuning algorithm. Computer simulations show displacements of multi-story structures applied to NNPPID system about environmental load-wind forces and earthquakes.

  • PDF

A comparison of the effect of SSI on base isolation systems and fixed-base structures for soft soil

  • Karabork, T.;Deneme, I.O.;Bilgehan, R.P.
    • Geomechanics and Engineering
    • /
    • v.7 no.1
    • /
    • pp.87-103
    • /
    • 2014
  • This study investigated the effect of soil-structure interaction (SSI) on the response of base-isolated buildings. Seismic isolation can significantly reduce the induced seismic loads on a relatively stiff building by introducing flexibility at its base and avoiding resonance with the predominant frequencies of common earthquakes. To provide a better understanding of the movement behavior of multi-story structures during earthquakes, this study analyzed the dynamic behavior of multi-story structures with high damping rubber bearing (HDRB) behavior base isolation systems that were built on soft soil. Various models were developed, both with and without consideration of SSI. Both the superstructure and soil were modeled linearly, but HDRB was modeled non-linearly. The behavior of the specified models under dynamic loads was analyzed using SAP2000 computer software. Erzincan, Marmara and Duzce Earthquakes were chosen as the ground motions. Following the analysis, the displacements, base shear forces, top story accelerations, base level accelerations, periods and maximum internal forces were compared in isolated and fixed-base structures with and without SSI. The results indicate that soil-structure interaction is an important factor (in terms of earthquakes) to consider in the selection of an appropriate isolator for base-isolated structures on soft soils.

Self-centering passive base isolation system incorporating shape memory alloy wires for reduction in base drift

  • Sania Dawood;Muhammad Usman;Mati Ullah Shah;Muhammad Rizwan
    • Smart Structures and Systems
    • /
    • v.31 no.5
    • /
    • pp.531-543
    • /
    • 2023
  • Base isolation is one of the most widely implemented and well-known technique to reduce structural vibration and damages during an earthquake. However, while the base-isolated structure reduces storey drift significantly, it also increases the base drifts causing many practical problems. This study proposes the use of Shape Memory Alloys (SMA) wires for the reduction in base drift while controlling the overall structure vibrations. A multi-degree-of-freedom (MDOF) structure along with base isolators and Shape-Memory-Alloys (SMA) wires in diagonal is tested experimentally and analytically. The isolation bearing considered in this study consists of laminates of steel and silicon rubber. The performance of the proposed structure is evaluated and studied under different loadings including harmonic loading and seismic excitation. To assess the seismic performance of the proposed structure, shake table tests are conducted on base-isolated MDOF frame structure incorporating SMA wires, which is subjected to incremental harmonic and historic seismic loadings. Root mean square acceleration, displacement and drift are analyzed and discussed in detail for each story. To better understand the structure response, the percentage reduction of displacement is also determined for each story. The result shows that the reduction in the response of the proposed structure is much better than conventional base-isolated structure.

Meaning of Housing through Oral Life History of Korean Chineses in Harbin, China : Focused on experiences of housing structure type and pathway approach (생애구술을 통해 본 중국 할빈 지역 조선족의 주거의 의미 : 주거유형 경험과 경로접근을 중심으로)

  • Hong, Hyung-Ock
    • Journal of Families and Better Life
    • /
    • v.28 no.5
    • /
    • pp.167-181
    • /
    • 2010
  • This research was designed to explore the meaning of housing among Korean Chinese in Harbin, China. In particular, the meaning of housing was examined by using the pathway approach. Utilizing qualitative research methods, this study administered the in-depth interview on the oral history of an individual life, and the 5 elderly persons in their 60s and 70s participated in the individualized interviews that were conducted from May 28 to 31 in 2010. The main findings of meaning of housing were as follows; 1. Similarly to the meaning of housing in 1970s and 1980s in Korea, house was viewed as both a shelter for family members and relatives and a place for their comfort. 2. Prior to multi-story residences, Harbin had only 3 different forms of single-story houses available; Chinese style with Kang and soil room(地室), Korean style with 'Ondol', and Russian style with open floor and Pechka, The promotion at work enabled participants to move to multi-story residences, their moving time varied from 1970 to 1991, and the residential moving determined their current housing status. 3. Multi-story residences were available around 1970s, floor-heating system was introduced from 1990s, and high-rise apartments were built from 1998. Korean Chinese(朝鮮族) weren't satisfied with the spatial composition of individual units embedded into the Chinese culture, especially, entrance, kitchen, bathroom and veranda. 4. Based on assimilation through socialism, adaptation to socialist society and capitalist acculturation, the lifestyles of the interviewees were categorized into five types - capitalist-proactive(Ms. KS), socialist-pragmatic(Ms. J), socialist-inducive(Ms. KY), family centered-conservative(Ms. L), and socialist-adaptive(Ms. P). This study implies that housing-related services for Korean Chinese are necessarily provided so as to embrace their life style and cultural identity in housing design, and further studies need to be explored.

Study of Integrated Optimal Design of Smart Top-Story Isolation and Building Structures in Regions of Low-to-Moderate Seismicity (중약진지역 구조물과 스마트 최상층 면진시스템의 통합최적설계에 대한 연구)

  • Kim, Hyun-Su;Kang, Joo-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.5
    • /
    • pp.13-20
    • /
    • 2013
  • In order to reduce seismic responses of a structure, additional dampers and vibration control devices are generally considered. Usually, control performance of additional devices are investigated for optimal design without variation of characteristics of a structure. In this study, multi-objective integrated optimization of structure-smart control device is conducted and possibility of reduction of structural resources of a building structure with smart top-story isolation system has been investigated. To this end, 20-story example building structure was selected and an MR damper and low damping elastomeric bearings were used to compose a smart base isolation system. Artificial earthquakes generated based on design spectrum of low-to-moderate seismicity regions are used for structural analyses. Based on numerical simulation results, it has been shown that a smart top-story isolation system can effectively reduce both structural responses and isolation story drifts of the building structure in low-to-moderate seismicity regions. The integrated optimal design method proposed in this study can provide various optimal designs that presents good control performance by appropriately reducing the amount of structural material and damping device.

Difference analysis of the collapse behaviors of the single-story beam-column assembly and multi-story planar frame

  • Zheng Tan;Wei-Hui Zhong;Bao Meng;Xing-You Yao;Yu-Hui Zheng;Yao Gao;Shi-Chao Duan
    • Steel and Composite Structures
    • /
    • v.50 no.3
    • /
    • pp.265-280
    • /
    • 2024
  • The collapse behavior observed in single-story beam-column assembly (SSBCA) do not accurately represent the actual overall stress characteristic of multi-story frame structure (MSFS) under column loss scenario owing to ignoring the interaction action among different stories, leading to a disconnection between the anti-collapse behaviors of "components" and "overall structures", that is, the anti-collapse performance of frame structures with two different structural scales has not yet formed a combined force. This paper conducts a numerical and theoretical study to explore the difference of the collapse behaviors of the SSBCA and MSFS, and further to reveal the internal force relationships and boundary constraints at beam ends of models SSBCA and MSFS. Based on the previous experimental tests, the corresponding refined numerical simulation models were established and verified, and comparative analysis on the resistant-collapse performance was carried out, based on the validated modeling methods with considering the actual boundary constraints, and the results illustrates that the collapse behaviors of the SSBCA and MSFS is not a simple multiple relationship. Through numerical simulation and theoretical analysis, the development laws of internal force in each story beam under different boundary constraints was clarified, and the coupling relationship between the bending moment at the most unfavorable section and axial force in the composite beam of different stories of multi story frames with weld cover-plated flange connections was obtained. In addition, considering the effect of the yield performance of adjacent columns on the anti-collapse bearing capacities of the SSBCA and MSFS during the large deformation stages, the calculation formula for the equivalent axial stiffness at the beam ends of each story were provided.

Design of Friction Dampers installed at a Multi-Story Building under Seismic Load (지진하중을 받는 다층 건물에 설치된 마찰감쇠기 설계)

  • Seong, Ji-Young;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.4
    • /
    • pp.457-462
    • /
    • 2011
  • In this study, a simplified design procedure for friction dampers of a multi-story structure in order to reduce seismic response is proposed. To get insight for control effect of the structure with friction dampers is difficult, because of a nonlinear characteristic by a friction damper. Since a control force of a friction damper is influenced by coupling velocity between floors, adjoining modes are coupled. Thus structural response are derived by assuming steady-state response in resonance. As it is impossible that an exact solution is obtained for seismic load, first, a closed form solution can be achieved under harmonic vibration. Second, to convert a three-story building into a single-degree-of-freedom(SDOF) structure, modal analysis is performed. Third, an equivalent damping ratio is derived with utilizing closed form solution. And response reducing factor is proposed by it. Finally, friction force of a damper is designed for using response reducing factor, and then designed dampers are verified for seven seismic data. The nonlinear analysis results confirm the validity of the proposed procedure.

Full-scale tests of two-story RC frames retrofitted with steel plate multi-slit dampers

  • Javidan, Mohammad Mahdi;Nasab, Mohammad Seddiq Eskandari;Kim, Jinkoo
    • Steel and Composite Structures
    • /
    • v.39 no.5
    • /
    • pp.645-664
    • /
    • 2021
  • There is a growing need of seismic retrofit of existing non-seismically designed structures in Korea after the 2016 Gyeongju and 2017 Pohang earthquakes, especially school buildings which experienced extensive damage during those two earthquakes. To this end, a steel multi-slit damper (MSD) was developed in this research which can be installed inside of partition walls of school buildings. Full-scale two-story RC frames were tested with and without the proposed dampers. The frames had structural details similar to school buildings constructed in the 1980s in Korea. The details of the experiments were described in detail, and the test results were validated using the analysis model. The developed seismic retrofit strategy was applied to a case study school building structure, and its seismic performance was evaluated before and after retrofit using the MSD. The results show that the developed retrofit strategy can improve the seismic performance of the structure to satisfy a given target performance level.

Investigation of Floor Impact Sound Levels in Rahmen Structure Multi-story Residential Buildings (라멘복합구조 공동주택의 바닥충격음 실태)

  • 정정호;송희수;전진용
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.308-311
    • /
    • 2004
  • It is reported that there is a limit in increasing heavy-weight impact noise isolation performance of the load bearing wall system apartments to meet the regulation of the Ministry of Construction and Transportation (MOCT). To increase the heavy-weight impact noise isolation performance, improvement in structural systems such as increasing concrete slab thickness and application of rahmen structure were proposed. In this study floor impact sound levels from toil apartments with two rahmen structure multi-story residential buildings were measured before the construction of the buildings finished. Measurements were made at living room and two bedrooms at each apartment when the finishing processes were finished. The average value of light-weight impact sound level from ten apartments was 56dB (L'$\sub$n,Aw/). The heavy-weight impact sound level was 44dB (L'$\sub$i.Fmax.Aw/) and the impact sound level of the impact ball was 41dB(L'$\sub$i.Fmax.Aw/), As a result floor impact noises at the rahmen structure system were lower than the regulation level.

  • PDF