• Title/Summary/Keyword: Multi module

Search Result 1,007, Processing Time 0.403 seconds

A New Approach to Reduced-Order Modeling of Multi-Module Converters

  • Park, Byung-Cho
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.4
    • /
    • pp.92-98
    • /
    • 1997
  • This paper presents a new approach to obtaining a reduced-order model for multi-module converters. The proposed approach can be used to derive the reduced-order model for a wide class of multi-module converters including pulse-width-modulated (PWM) converters, soft-switched PWM converters, and resonant converters. The reduced-order model has the structure of a conventional single-module converter while preserving the dynamics of the original multi-module converter. Derivation procedures and the use of the reduced-order model is demonstrated using a three-module boost converter.

  • PDF

Time Series Analysis of Crystalline Silicon Photovoltaic Module Certification Results (결정질 실리콘 태양광발전모듈 인증 실적의 시계열 분석)

  • Han, Yun-Cheol;Kim, Ik-Pyo;Kang, Kyu-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.3
    • /
    • pp.33-45
    • /
    • 2017
  • Crystalline silicon photovoltaic module certification began in 2007. "Renewable Energy Equipment Certification Scheme" was implemented until July 28, 2015. Then, the scheme was changed to "KS Certification Scheme" since July 29, 2015. A total of 2,331 models have been certified by 2016. The proportion of multi crystalline modules in certified products is higher than that of mono crystalline modules, and Korean modules account for 78% of the total certification modules. Chinese solar cells account for the highest percentage of 40% of the total modules and 62.4% of modules certified in 2016 use Chinese solar cells. With the development of technology, module power is continuously increasing, and efficiency is also rising. The average efficiency of mono crystalline module is 0.74% higher than the average of multi crystalline module. As a result of comparing domestic module with Chinese module, the highest efficiency of mono crystalline module and multi crystalline module and the average efficiency of mono crystalline module are higher than those of Chinese module, but the average efficiency of multi crystalline module is similar to that of Chinese module.

An Implementation of The Embedded-Based Multi Mode Receiver Module & Demuxer (임베디드용 멀티모드 방송 수신 모듈 및 역다중화기 설계 및 구현)

  • Kwon, KiWon;Kim, SeongJun;Park, SeHo;Park, YoungSuk;Hong, SukGun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.6 no.2
    • /
    • pp.62-67
    • /
    • 2011
  • In this paper, Multi Mode Receiver Module is designed in one H/W module for Multi-mode Digital Broadcasting. Multi mode means Digital TV, Mobile TV and Digital Radio on the Broadcasting. and T-DMB, DAB(+), ISDB-T and DVB-T standard. Our Module can receive various broadcasting signal such as ISDB-T, DVB-T and DAB. The Multi mode Receiver Module & demuxer was implemented using the one SoC Chip has good performances to receive the multi mode signals as well as standard interface such as SPI, to connect the main CPU Unit.

A multi-modal neural network using Chebyschev polynomials

  • Ikuo Yoshihara;Tomoyuki Nakagawa;Moritoshi Yasunaga;Abe, Ken-ichi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1998.10a
    • /
    • pp.250-253
    • /
    • 1998
  • This paper presents a multi-modal neural network composed of a preprocessing module and a multi-layer neural network module in order to enhance the nonlinear characteristics of neural network. The former module is based on spectral method using Chebyschev polynomials and transforms input data into spectra. The latter module identifies the system using the spectra generated by the preprocessing module. The omnibus numerical experiments show that the method is applicable to many a nonlinear dynamic system in the real world, and that preprocessing using Chebyschev polynomials reduces the number of neurons required for the multi-layer neural network.

  • PDF

Electrical Characteristics Analysis for single-crystalline and multi-crystalline PV module optical character. (단결정과 다결정 태양전지 모듈의 광학적 특성에 따른 전기적 출력 특성 분석)

  • Lee, Jin-Seob;Kang, Gi-Hwan;Park, Chi-Hong;Yu, Gwon-Jong;Ahn, Hyunggun;Han, Deuk-Young
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1100-1101
    • /
    • 2008
  • After lamination process, Isc is increased by sheet reflection. This paper presents the electrical output characteristics by back sheet reflection. The experiments was conducted by using single crystalline and multi crystalline PV module. The reflection area of single crystalline PV module is larger than multi one due to the difference of solar cell manufacturing. The experiments show that the increased performance ratio of single crystalline PV module output power is 1.55% rather than that of multi crystalline PV module output power is 1.13%. In addition, it is expected that the output power of single one rather than multi-one is increased by the lower temperature when the PV module is installed outside. The results can be reconsidered by the test material and test process. Back sheet used for humidity prevention makes PV module output power increasing.

  • PDF

Study of Multi Function RF Module Using Amplifier and Multiplier (증폭기 및 체배기를 이용한 다기능 RF 모듈에 관한 연구)

  • Kim, Tae-Hoon;Joo, Jae-Hyun;Koo, Kyung-Heon
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.3
    • /
    • pp.391-396
    • /
    • 2010
  • This paper presents some important research result comparisons for multi function RF modules which use amplifier or frequency multiplier. By using multiplier, multi function module can be realized amply in comparison to multi band module which has separate block for each frequency band. Some com paring analysis among the switching method between separate amplifier and multiplier, the structure using frequency selective reflector, and the module using the defected ground structure. The multi function module which operates as amplifier or multiplier with input frequency is developed and input frequency suppression and output harmonics suppression can be improve d by using defected ground structure.

Experimental Static Strength Evaluation of a Passenger Car Aluminium Multi-link Suspension Corner Module (승용차 알루미늄 멀티링크 현가장치 코너모듈의 실험적 정강도 특성 평가)

  • Cho, Wonyong;Choi, Gyoojae
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.4
    • /
    • pp.166-173
    • /
    • 2013
  • An aluminum suspension corner module is widely used in high class passenger cars to reduce vehicle weight and improve fuel economy. According to the change of material and suspension type, the evaluation of the static strength and failure mode of the corner module is important. In this study, static strength and failure mode analysis of aluminium multi-link suspension corner module is presented. Static strength test system is designed and static failure mode tests of the corner module are carried out in longitudinal, lateral, and vertical direction. From the resuls of the tests we found that the failure modes are different compare to those of the steel corner module. The static failure modes and load-displacement curves of this study will be used as a guidance in design of a passenger car aluminium multi-link suspension corner module.

Experimental Study on Thermal Characteristics of Heat Exchanger Modules for Multi Burner Boiler (멀티버너 보일러용 열교환기 모듈 특성 시험 - 모듈 순서에 따른 특성결과 -)

  • Kang, Sae-Byul;Kim, Jong-Jin;Ahn, Joon
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.3053-3058
    • /
    • 2008
  • We develop a heat exchanger modules for a multi-burner boiler. The heat exchanger module is kind of a heat recovery steam generator (HRSG). This heat recovery system has 4 heat exchanger modules. The 1st module consists of 27 bare tubes due to high temperature exhaust gas and the others consist of 27 finned tubes. The maximum steam pressure of each module is 1 MPa and tested steam pressure is 0.7 MPa. In order to test these heat exchanger modules, we make a 0.5t/h flue tube boiler (LNG, $40\;Nm^3/h$). We tested the heat exchanger module with changing the position of each heat exchanger module. We measured the inlet and outlet temperature of each heat exchanger module and calculated the heat exchange rate. The results show that if module C is placed at second stage (the 1st stage is always module O, bare tube module), there is no need to attach an additional heat exchanger module. In this case the exit temperature of module C is low enough to enter an economizer which is more effective in heat recovery than a heat exchanger module.

  • PDF

Generalized Stability Criterion for Multi-module Distributed DC System

  • Liu, Fangcheng;Liu, Jinjun;Zhang, Haodong;Xue, Danhong
    • Journal of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.143-155
    • /
    • 2014
  • The stability issues of a multi-module distributed DC power system without current-sharing loop are analyzed in this study. The physical understanding of the terminal characteristics of each sub-module is focused on. All the modules are divided into two groups based on the different terminal property types, namely, impedance (Z) and admittance (Y) types. The equivalent circuits of each group are established to analyze the stability issues, and the mathematical equations of the equivalent circuits are derived. A generalized criterion for multi-module distributed systems is proposed based on the stability criterion in a cascade system. The proposed criterion is independent of the power flow direction.

A Study on the Method for Multi-dimensional Module Plan of Apartment Houses for Remodeling - Based on the systematization of Emotion-Information for Multi-Dimensional Module Composition of the Unit household (공동 주택 리모델링 다차원모듈 설계 기법에 관한 연구 - 단위세대 다차원모듈 구성을 위한 감성정보 체계화를 중심으로 -)

  • Lee, Chan-Yong;Kwon, Sung-Sun
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.5 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • The major goal of this study is drawing design plan factors considering residents' life cycle and life style when remodeling design is needed. By drawing such design factors, the study will propose an alternative remodeling design plan. Such design method was defined as Multi-Dimensional module design method. And constructing data-system based on Multi-Dimensional module was secondary goal in this study. The details are as follows: Based on analysis of Residents' demand for remodeling and features of emotion-design applied to remodeling, the system which is suitable for application in remodeling design method was conducted. Based on the type of construction materials, the level value was set up according to emotion-factor application. Also, by conducting coding operation according to the distinction of construction materials, this study seeks the unit drawing method of information for constructing emotion-information system.

  • PDF