The Carrier-based PWM Method for Voltage Balance of Flying Capacitor Multi-bevel Inverter (플라잉 커패시터 멀티-레벨 인버터의 커패시터 전압 균형을 위한 캐리어 비교방식의 펄스폭변조기법)

  • 이상길;강대욱;이요한;현동석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.1
    • /
    • pp.65-73
    • /
    • 2002
  • This paper proposes a new carrier-based PWM method to solve the most serious problem of flying capacitor multi-level inverter that is the unbalance of capacitor voltages. The voltage unbalance occurs due to the difference of each capacitor's charging and discharging time applied to Flying Capacitor Inverter. New solution controls the variation of capacitor voltages into the mean '0'during some period by means of new carriers using the leg voltage redundancy in the flying capacitor inverter. The solution can be easily expanded to the multi-level inverter. The leg voltage redundancy in the new method makes the switching loss of device equals to the conduction loss of device. This paper will examine the unbalance of capacitor voltage and the conventional theory of self-balance using Phase-shifted carrier. And then the new method that is suitable to the flying capacitor inverter will be explained.

A Hybrid Active Power Filter for Electric-Railway Systems using Multi-Level Inverters (멀티레벨 인버터를 이용한 전기철도용 하이브리드 능동전력필터)

  • Kim Yoon-Ho;Kim Soo-Hong;Rho Sung-Chan;Lee Kang-Hee
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1334-1339
    • /
    • 2004
  • This paper proposes transformerless power conversion system consisting of a single-phase diode rectifier and a shunt hybrid filter for the electric-railway system. The hybrid filter consists of a single tuned LC filter per a phase and a low-rated NPC type multi-level inverter. Compared with conventional active filters. Transformers are not used. Also, LC filter works as not only a harmonic filter tuned at the 5th harmonic frequency but also a switching-ripple filter. The rating of the active filter can be decreased by using a NPC type multi-level inverter. The simulation results confirm the validity of the system.

  • PDF

A Hybrid Active Power Filter for Electric-Railway Systems using Multi-Level Inverters (멀티레벨 인버터를 이용한 전기철도용 하이브리드 능동전력필터)

  • Kim Yoon-Ho;Kim Soo-Hong;Rho Sung-Chan;Lee Kang-Hee
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1427-1432
    • /
    • 2004
  • This paper proposes transformerless power conversion system consisting of a single-phase diode rectifier and a shunt hybrid filter for the electric-railway system. The hybrid filter consists of a single tuned LC filter per a phase and a low-rated NPC type multi-level inverter. Compared with conventional active filters. Transformers are not used. Also, LC filter works as not only a harmonic filter tuned at the 5th harmonic frequency but also a switching-ripple filter. The rating of the active filter can be decreased by using a NPC type multi-level inverter. The simulation results confirm the validity of the system

  • PDF

NTV 식별과정 없는 멀티레벨 인버터의 신속한 공간벡터 PWM 변조기법

  • Oh, Jin-Seok;Lee, Jong-Ho;Jin, Sun-Ho;Kwak, Jun-Ho;Jo, Kwan-Jun;Kim, Jong-Do
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.253-254
    • /
    • 2006
  • this paper suggest a new space vector PWM modulation method with short processing time which does not need idenfication of nearest three vectors(NTV) and duty calculation for each vector. The suggested PWM method makes mean value of phase voltage to be same as reference during every modulation period by use of a triangle in small hexagon on multi-level vector space. This paper described the suggested modulation method can be successfully applied to the space vector modulation use of multi-level inverter by computer simulations and experiments.

  • PDF

Multi-Level Inverter for Regenerative Breaking of SRM (SRM의 회생제동을 위한 멀티레벨 인버터)

  • Lee S. H.;Ahn G. S.;Park S. J.;Ahn J. W,
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.239-242
    • /
    • 2001
  • Energy recovery in the regenerative region is very important when SRM(Switched Reluctance Motor) is used in traction drive. This is because that to reduce energy toss during mechanical breaking and/or to have a high efficiency drive during breaking. To control excitation voltage in motor operation and regenerative voltage in the generator operation in the SRM, multi-level voltage control is effective. This paper proposes multi-level inverter which is useful for motoring and regenerative operation in SRM. The proposed method is verified by experiment.

  • PDF

A Symmetric Carrier Technique of CRPWM for Voltage Balance Method of the Flying Capacitor Multi-level Inverter (플라잉 커패시터 멀티-레벨 인버터의 커패시터 전압 균형을 이루기 위한 캐리어 비교방식의 대칭 기법)

  • 전재현;김태진;강대욱;현동석
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.12
    • /
    • pp.624-631
    • /
    • 2003
  • This paper presents a simple carrier symmetric method for the voltage balance of flying capacitors in FCMLI(flying capacitor multi-level inverter). To achieve the voltage balance of flying capacitors, the utilization of each carrier must be balanced during a half-cycle of the switching period such as PSPWM(Phase-Shifted PWM). However, the CRPWM(Carrier Redistribution PWM) method causes the fluctuation of flying capacitor voltages because the balanced utilization of carriers is not achieved. Moreover, it does not consider that the load current change has an influence on flying capacitor voltages by assuming that the current flows into the load. To overcome the drawbacks of CRPWM, it is modified by the technique that carriers of each band are disposed symmetrically at every fundamental period. Firstly, the CRPWM method is reviewed and the theory on voltage balance of flying capacitors is analyzed. The proposed method is introduced and is verified through the experiment result.

A Single Phase Multi-level Active Power Filter System using Instantaneous Reactive Power Harmonic Detection Method (순시 무효 전력 고조파 검출방법을 이용한 단상 멀티레벨 능동전력 필터)

  • Kim Soo-Hong;Kim Sung-Min;Lee Kang-Hee;Kim Yoon-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.296-301
    • /
    • 2005
  • This paper proposing the use of the Instantaneous reactive power method as a harmonic detection method for a single phase active filter system. This method is to detect harmonic components through d-q frame approach. The conventional use of d-q frame approach for a 3-phase system Is extended to the single phase system. The proposed system uses a multi-level inverter for harmonic compensation and the inverter is connected to the input side without using transformers. The proposed algorithm is verified by simulation and experiment.

Cascade 3-Phase IHCML Inverter using Maximal Distension Vector Control (최근접 벡터 제어기법을 이용한 cascade 3상 IHCML 인버터)

  • Park, Jin-Hyun;Park, Sung-Jun;Song, Sung-Geun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.101-109
    • /
    • 2009
  • In this paper, a new method, cascade 3 phase IHCML(Isolated H-bridge Cascade Multi-Level) inverter and a control method is proposed by using two 3-phase transformers that have respectively different transformation rates. Vector control technique in which the highest proximity vector has been used is also put into use. With this process, the switching frequency is almost identical with the output fundamental frequency, which makes less switching loss, and the switching frequency of the small volume of the H-bridge that is in charge of small power is highly controlled, which improves the quality of the output voltage.

Basic Characteristic of 5-level Inverter with Different Divided DC Link Voltage

  • Matsuse, Kouki;Matsumoto, Takafumi;Kodera, Yuji
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.2
    • /
    • pp.179-183
    • /
    • 2013
  • This paper report on experimental results of 5-level inverter by DC divided link voltage. We have alreday reported that DC divided link valtage comes to be able to reduse harmonic of out line voltage. So we tested whether DC divided link voltage can reduce harmonics in experimental setup. This paper shows simulation results and experimental results. And we confirmed that DC divided link voltage can also apply in experimental setup.

A Novel Regenerative Snubber suitable to Multi-Level Inverters with Series-Connected GTOs (직렬 연결된 GTO로 구성된 멀티레벨 인버터에 적합한 새로운 회생 스너버에 관한 연구)

  • Chae, G.;Cho, Guk-C.;Jung, Gu-H.;Ryoo, Tae-H.;Cho, Gyu-H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.585-587
    • /
    • 1996
  • A simple regenerative snubber structure is proposed, which is applicable to multi-level inverter with series-connected GTOs for high power applications. The novel snubber structure can solve large energy loss problems and guarantee safe operation of power converter can be achieved. The proposed new snubber has the potential of high performance and high reliability and is particularly suitable to high power and multi-level application with series connected power devices. The snubber voltage and current waveforms are analized and shown the simulation and experimental results for a GTO 3-level inverter circuit with inductive load.

  • PDF