• 제목/요약/키워드: Mu Wave

검색결과 736건 처리시간 0.025초

초음속 제트 유동의 정량적 가시화 (Quantitative Visualization of Supersonic Jet Flows)

  • 이재혁;;김희동
    • 한국가시화정보학회지
    • /
    • 제15권1호
    • /
    • pp.53-63
    • /
    • 2017
  • Sonic and supersonic jets include many complicated flow physics associated with shock waves, shear layers, vortices as well as strong interactions among them, and have a variety of engineering applications. Much has been learned from the previous researches on the sonic and supersonic jets but quantitative assessment of these jets is still uneasy due to the high velocity of flow, compressibility effects, and sometimes flow unsteadiness. In the present study, the sonic jets issuing from a convergent nozzle were measured by PIV and Schlieren optical techniques. Particle Image Velocimetry (PIV) with Olive oil particles of $1{\mu}m$ was employed to obtain the velocity field of the jets, and the black-white and color Schlieren images were obtained using Xe ramp. A color filter of Blue-Green-Red has been designed for the color Schlieren and obtained from an Ink jet printer. In experiments, two types of sonic nozzles were used at different operating pressure ratios(NPR). The obtained images clearly showed the major features of the jets such as Mach disk, barrel shock waves, jet boundaries, etc.

Development of Bio-ballistic Device for Laser Ablation-induced Drug Delivery

  • Choi, Ji-Hee;Gojani, Ardian B.;Lee, Hyun-Hee;Jeung, In-Seuk;Yoh, Jack J.
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제9권3호
    • /
    • pp.68-71
    • /
    • 2008
  • Transdermal and topical drug delivery with minimal tissue damage has been an area of vigorous research for a number of years. Our research team has initiated the development of an effective method for delivering drug particles across the skin (transdermal) for systemic circulation, and to localized (topical) areas. The device consists of a micro particle acceleration system based on laser ablation that can be integrated with endoscopic surgical techniques. A layer of micro particles is deposited on the surface of a thin metal foil. The rear side of the foil is irradiated with a laser beam, which generates a shockwave that travels through the foil. When the shockwave reaches the end of the foil, it is reflected as an expansion wave and causes instantaneous deformation of the foil in the opposite direction. Due to this sudden deformation, the microparticles are ejected from the foil at very high speeds, and therefore have sufficient momentum to penetrate soft body tissues. We have demonstrated this by successfully delivering cobalt particles $3\;{\mu}m$ in diameter into gelatin models that represent soft tissue with remarkable penetration depth.

직선집속 PVDF 초음파트랜스듀서의 제작과 응용 I. 제작 및 특성평가 (Fabrication of PVDF Line Focus Ultrasonic Transducer and its Application I. Fabrication and Characteristics Evaluation)

  • 윤혁준;하강열;김무준
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1999년도 학술발표대회 논문집 제18권 1호
    • /
    • pp.387-390
    • /
    • 1999
  • 누설탄성표면파(Leaky Surface Acoustic Wave : LSAW) 측정에 사용하는 것을 목적으로 PVBF 압전막을 이용하여 직선집속 초음파트랜스듀서를 제작하고 그 특성을 평가하였다. 제작은 한쪽 면이 원통형 구조를 갖는 구리, 알루미늄, 3mmPVC-에폭시 3가지 재료를 배면층으로 사용하여 각각에 PVDF를 부착시켜서 수중에 음파를 방사하도록 구성하였고, 특성평가는 임펄스응답 특성과 음장 특성으로 나누어서 평가하였다. 임펄스응답 특성은 제작한 3종류의 집속 초음파트랜스듀서에 대해 실험적으로 측정하고, Mason 등가회로1)를 이용한 이론적 해석결과와 비교하였다. 음장특성 측정실험은 구리를 배면체로 하여 제작한 집속 초음파트랜스듀서에 대해서 실시하였고, 그 이론적인 계산결과는 Raylelgh-Somme-rfeld 회 절이론2)을 도입하여 초점면에 형성되는 음압분포를 계산하는 것으로 얻어졌다. 실험은 펄스 초음파 송수기 및 $2{\mu}m/step$으로 이동하는 정밀 x-y-z 스테이지를 컴퓨터에 연결하여 자동 측정하는 것으로 수행되었는데, 그 결과는 이론 해석결과와 비교적 잘 일치하였다.

  • PDF

2-Bromoacetyltriphenylene 유도체화제를 이용한 카르복실기 함유성분의 분석법 (I) - 프로스타글란딘 $E_2$$F_2{\alpha}$ 혼합물의 HPLC에 의한 분리정량 (UV-HPLC Determination of Carbowyl Group Using 2-Bromoacetyltriphenylene as a Pre-labeling Reagent - The isolative determination of prostaglandin $E_2$ and $F_2{\alpha}$ by HPLC)

  • 이왕규;정해수;김박광
    • 약학회지
    • /
    • 제30권6호
    • /
    • pp.311-316
    • /
    • 1986
  • A new UV labeling reagent was developed and used in HPLC for the determination of prostaglandin $E_2$ which have weak UV light-absorbing property. This reagent, 2-bromoacetyltriphenylene, was synthesized by the bromination of 2-acetyltriphenylene which was obtained from triphenylene by Friedel-Crafts reaction. The wave length maximum (${\lambda}_{max}^{CH_3CN}$ of this reagent was 268nm. Prostaglandin E$_2$ was extracted from prostaglandin E$_2$-$\beta$-cyclodextrin using a Sep-pak $C_{18}$ cartridge. The prostaglandin E$_2$ was labeled with 2-bromoacetyl-triphenylene in aectonitrite using 18-crown-6-ether as catalyst. Derivatized prostaglandins were separated on a reversed-phase column (Radial-pak) $\mu$-Bondapak $C_{18}$ using acetonitrile: water=60:40 as mobile phase. The effluent was monitored by UV detector at 254nm filter kit. Linearity of calibration curve was obtained between 30ng and 140ng, and the lower limit of detection was 5ng.

  • PDF

A 1.2 V 7-bit 1 GS/s CMOS Flash ADC with Cascaded Voting and Offset Calibration

  • Jang, Young-Chan;Bae, Jun-Hyun;Lee, Ho-Young;You, Yong-Sang;Kim, Jae-Whui;Sim, Jae-Yoon;Park, Hong-June
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제8권4호
    • /
    • pp.318-325
    • /
    • 2008
  • A 1.2 V 7-bit 1 GS/s CMOS flash ADC with an interpolation factor of 4 is implemented by using a $0.13\;{\mu}m$ CMOS process. A digital calibration of DC reference voltage is proposed for the $1^{st}$ preamp array to compensate for the input offset voltage of differrential amplifiers without disturbing the high-speed signal path. A 3-stage cascaded voting process is used in the digital encoder block to eliminate the conescutive bubbles up to seven completely, if the $2^{nd}$ preamp output is assumed to have a single bubble at most. ENOB and the power consumption were measured to be 5.88 bits and 212 mW with a 195 MHz $400\;mV_{p-p}$ sine wave input.

초음파센서를 이용한 냉중성자원 수직공 형상측정 (Measurement of the Shape of the Cold Neutron Source Vertical Hole by Ultrasonic Wave Sensor)

  • 박국남;최창웅;심철무
    • 대한기계학회논문집A
    • /
    • 제24권9호
    • /
    • pp.2167-2173
    • /
    • 2000
  • The HANARO (High-flux Advanced Neutron Application Reactor) has operated since 1995. The Cold Neutron(CN) hole was implanted in the reflector tank from the design stage. Before a vacuum chamber and a moderator cell for the cold neutron source are installed into the CN hole, it is necessary to measure the exact size of the inside diameter and thickness of the CN hole to prevent the interference problem. Due to inaccessibility and high radiation field in the CN hole, a mechanical measurement method is not permitted. The immersion ultrasonic technique is considered as the best method to measure the thickness and the diameter. The 4 axis manipulator of the 2 channel of a sensor module was fabricated. The transducer of 10 MHz results in 0.03 nun of resolution. The inside diameter and thickness for 550 points of the CN hole were measured using 2 channel ultrasonic sensors. The results showed that the thickness is in the range of 13-6.7 mm and inside diameter is in the range of o 156-165. These data will be a good reference in the design of a cold neutron source facility.

Fresnel 영역에서의 SDTA 방법을 이용한 전산묘사에 의한 Surface Relief Hologram Mask 기록 조건 최적화 (Surface Relief Hologram Mask Recording Simulation and Optimization Based on SDTA in the Fresnel Diffraction Zone)

  • 이성진
    • 대한기계학회논문집A
    • /
    • 제33권8호
    • /
    • pp.793-798
    • /
    • 2009
  • In this paper, the simulation and optimization of SRH (Surface Relief Hologram) masks for printing LCD gate patterns using TIR (Total Internal Reflection) holographic lithography was investigated. A simulation and optimization algorithm based on SDTA (Scalar Diffraction Theory Analysis) method was developed. The accuracy of the algorithm was compared to that of the RCWA (Rigorous Coupled Wave Analysis) method for estimating the Fresnel diffraction pattern of Cr amplitude masks for the given system geometry. In addition, the results from the optimization algorithm were validated experimentally. It was found that one to the most important conditions for the fabrication of SRH masks is to avoid nonlinear shape distortions of the resulting grating. These distortions can be avoided by designing SRH masks with recorded gratings having small aspect ratios of width versus depth. The optimum gap size between the Cr and SRH masks was found using the optimization algorithm. A printed LCD gate pattern with a minimum line width of $1.5{\mu}m$ exposed using the optimized SRH mask was experimentally demonstrated.

[ $Bi_2Sr_2CaCu_2O{8+\delta}$ ] Intrinsic Josephson Junctions in a Parallel Magnetic Field

  • Lee, J.H.;Chong, Yon-Uk;Lee, Su-Youn;Khim, Z.G.
    • Progress in Superconductivity
    • /
    • 제1권2호
    • /
    • pp.110-114
    • /
    • 2000
  • We have investigated the Josephson vortex dynamics in $Bi_2Sr_2CaCu_2O{8+\delta}$ intrinsic Josephson junctions subjected to a magnetic field parallel to $CuO_2$ planes. We investigated mesas with $40\times40{\mu}m^2$ in size and containing 6 and 20. intrinsic junctions. The zero field I-V characteristics exhibited a typical hysteretic, multi-branched nature of the intrinsic Josephson effect. At high magnetic fields (H>1.5 T), I-V characteristics showed flux flow steps. The Swihart velocity obtained from this observation was about $4.2\times10^5$ m/s, which was the lowest mode electromagnetic wave velocity of N coupled stack. The experimental I-V curves fitted well into the simple model of Cherenkov radiation including Ohmic and non-linear dissipation terms. This suggests that the dissipation mechanism of Josephson vortex be due to both Cherenkov radiation and quasiparticle tunneling current.

  • PDF

Paper, Thin Layer 및 Column Chromatography에 의한 요중의 Estriol, Estrone, Estadiol-17 β의 분리 정량에 관하여 (Studies on Separation, Detection and Quantitation of Estriol, Estrone, Estradiol-17 β in Urine of Dairy Cows by Paper, Thin Layer and Column Chromatography)

  • 양용관;한수남;조종후
    • 대한수의학회지
    • /
    • 제13권1호
    • /
    • pp.23-30
    • /
    • 1973
  • Thin layer, paper and column chromatography were compared for the separation, detection and quantitation of three kinds of estrogen in urine of dairy cows. While thin layer chromatography utilizing silica gel was better for the detection of estrogens, column chromatography using celite 545 was preferable. Spectrophotometry was compared with fluorometry for determination of estrone, estradiol-17 ${\beta}$ and estriol eluted by paper chromatography and column chromatography. Optical density of three standard estrogens showed almost same curve at maximum absorption wave length of 230 and $282m{\mu}$. However, the former showed a higher peak. In fluorometry, the fluorescence intensity of estrone and estradiol-17 ${\beta}$ were rather strong, when the estrogens were dissolved in sulfuric acid, and showed higher sensitivity than that of the spectrophotometry. However, in the case of estriol was exceptional.

  • PDF

Laser Direct Writing 방법을 이용한 광도파로 제작 (Fabrication of waveguide using UV Ar-ion laser direct writing)

  • 강희신;서정;이제훈;김정오
    • 한국레이저가공학회지
    • /
    • 제8권1호
    • /
    • pp.9-18
    • /
    • 2005
  • The laser direct writing method using a UV Argon-ion laser is studied for fabrication of waveguide. The laser direct writing system is constructed with a vision camera, a xy-stage, a motion controller and the delivery components of a laser beam. The UV Argon-ion laser has wavelength range of $333.6\~363.8$ nm. A photo-active UV curable polymer for a planar light-wave circuit(PLC) of single mode is used. This polymer is irradiated by Argon-ion laser and developed by a solvent after a post-baking. The optimum laser direct writing condition is obtained experimentally by changing various process parameters such as laser power, writing speed and focal length. The propagation and coupling loss of a optical waveguide was measured as 1dB/cm and 0.6dB/cm, respectively. Also, the minimum width of waveguide of $100{\mu}m$(ZPLW-207) is obtained. Finally, the waveguides of line, bend and branch type are successfully fabricated.

  • PDF