• 제목/요약/키워드: Motion repetition

검색결과 46건 처리시간 0.03초

Parallel Load Techinques Application for Transcranial Magnetic Stimulation

  • Choi, Sun-Seob;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • 제17권1호
    • /
    • pp.27-32
    • /
    • 2012
  • Transcranial magnetic stimulation requires an electric field composed of dozens of V/m to achieve stimulation. The stimulation system is composed of a stimulation coil to form the electric field by charging and discharging a capacitor in order to save energy, thus requiring high-pressure kV. In particular, it is charged and discharged in capacitor to discharge through stimulation coil within a short period of time (hundreds of seconds) to generate current of numerous kA. A pulse-type magnetic field is formed, and eddy currents within the human body are triggered to achieve stimulation. Numerous pulse forms must be generated to initiate eddy currents for stimulating nerves. This study achieved high internal pressure, a high number of repetitions, and rapid switching of elements, and it implemented numerous control techniques via introduction of the half-bridge parallel load method. In addition it applied a quick, accurate, high-efficiency charge/discharge method for transcranial magnetic stimulation to substitute an inexpensive, readily available, commercial frequency condenser for a previously used, expensive, high-frequency condenser. Furthermore, the pulse repetition rate was altered to control energy density, and grafts compact, one-chip processor with simulation to stably control circuit motion and conduct research on motion and output characteristics.

부배열 평균과 엔트로피 최소화 기법을 이용한 stepped-frequency ISAR 자동초점 기법 성능 향상 연구 (Application of Subarray Averaging and Entropy Minimization Algorithm to Stepped-Frequency ISAR Autofocus)

  • 정호령;김경태;이동한;서두천;송정헌;최명진;임효숙
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2008년도 춘계학술대회 논문집
    • /
    • pp.158-163
    • /
    • 2008
  • In inverse synthetic aperture radar (ISAR) imaging, An ISAR autofocusing algorithm is essential to obtain well-focused ISAR images. Traditional methods have relied on the approximation that the phase error due to target motion is a function of the cross-range dimension only. However, in the stepped-frequency radar system, it tends to become a two-dimensional function of both down-range and cross-range, especially when target's movement is very fast and the pulse repetition frequency (PRF) is low. In order to remove the phase error along down-range, this paper proposes a method called SAEM (subarray averaging and entropy minimization) [1] that uses a subarray averaging concept in conjunction with the entropy cost function in order to find target motion parameters, and a novel 2-D optimization technique with the inherent properties of the proposed entropy-based cost function. A well-focused ISAR image can be obtained from the combination of the proposed method and a traditional autofocus algorithm that removes the phase error along the cross-range dimension. The effectiveness of this method is illustrated and analyzed with simulated targets comprised of point scatters.

  • PDF

Reliability Evaluation for Hinge of Folder Devices Using ESPI

  • Kyungyoung Jhang;Minkwan Hyun;Lee, Taehun;Seokwon Chang
    • International Journal of Reliability and Applications
    • /
    • 제5권1호
    • /
    • pp.15-24
    • /
    • 2004
  • Folder type electronic devices have hinge to support the rotational motion of folder. This hinge is stressed by the rotational inertia moment of folder at the maximum open limit position of folder. This stress is repeated whenever the folder is open, and it is a cause of hinge fracture. In this paper, the reliability evaluation for the hinge fracture in the folder type cellular phone is discussed. For this, the durability testing machine using crank-rocker mechanism is developed to evaluate the life cycle of the hinge, and the degradation after repetitions of opening and shutting is evaluated from the deformation around the hinge, where the deformation is measured by ESPI (electronic speckle pattern interferometer). Experimental results showed that ESPI was able to measure the deformation of hinge precisely, so we could monitor the change of deformation around the hinge as the repetition number of folder open is increased.

  • PDF

등속성 운동시 각속도에 따른 총 일량(total work)의 변화 (Total Work Changes at Different Angular Velocities during Isokinetic Exercise)

  • 김도희;박영석;윤장원;김종만
    • 한국전문물리치료학회지
    • /
    • 제2권1호
    • /
    • pp.51-61
    • /
    • 1995
  • In general, research in isokinetic exercise has focussed on studies of peak torque. However, peak torque is not always sufficient to assess the real amount of motion or to determine endurance. In this study, the subjects were 54 healthy students who performed continuous maximal isokinetic knee flexion and extension until their total work per time reached 50% of their maximal total work. Isokinetic curves were then plotted. Total work sums, exercise durations in seconds, and the numbers of repetitions were compared with reference to subject gender, angular velocity and muscle group. The relationship between total work sum, duration and number of repetition and thigh circumference plus leg length was computed. In addition, the characteristics of total work per second and total work per time were calculated. Results showed the total work sums differed greatly from muscle group to muscle group and with different angular velocities. The duration in seconds and the numbers of repetition differed only at higher angular velocity. Males achieved higher levels in every category except for some duration in seconds and some numbers of repetitions. Thigh circumference and leg length were deciding fators in every case, but duration in seconds and number of repetitions were not. These results suggest that measures of endurance should be included along with measures of total work when isokinetic studies are done. Measures of endurance in seconds are more accurate when isokinetic exercise is performed at lower angular velocities and numbers of repetitions at higher angular velocities.

  • PDF

3D 밀착형 팬츠와 키네시오 테이핑이 무릎관절의 등속성 굴곡 운동 시 하지의 근기능에 미치는 영향 (Effects of 3D Compression Pants and Kinesio Taping on Isokinetic Muscular Function of Leg During Knee Joint Flexion Motion)

  • 최지영;박희근;이왕록;홍경희
    • 한국의류학회지
    • /
    • 제40권2호
    • /
    • pp.240-257
    • /
    • 2016
  • This study determines the effect of 3D compression pants and Kinesio taping on muscular function of the leg during knee joint flexion and extension. Eight males participated in the experiment, wearing basic pants (BP), Kinesio taping on bare skin (KT), 3D compression pants with (KTP) and without Kinesio taping (CP). The test protocol for isokinetic muscular function was composed of four sets at three angular velocities (60, 180, $240^{\circ}/sec$) using Cybex 660. Peak torque and work per repetition of the lower limbs of eight males were analyzed from the result of Cybex. Agility and power of the subjects were examined from side step and sergeant jump. Peak torque, average power, work per repetition, force decay time of subjects wearing CP and KTP were significantly better than BP or KT, especially at low angular velocity of $60^{\circ}/sec$. The time to generate peak torque of subjects wearing BP was the longest, while the force-decay time of BP was the shortest. The application of Kinesio tape on skin did not increase muscle peak torque, work and power, but did shorten the time to generate peak torque.

20세기 이전 서양복식사에 나타난 주름의 조형성 - 남성복을 중심으로 - (A Study on the Formative Characters in the Pleat of Western Costume Before the 20th Century - Focusing on Men's Costume -)

  • 김주경;금기숙
    • 복식
    • /
    • 제62권2호
    • /
    • pp.26-39
    • /
    • 2012
  • This study intends to reconsider pleat, which was undermined as something too simple to express the details for women's costume, by focusing on the aesthetic value of plea in men's costumes in the west before the 20th century. Furthermore, based on the aesthetic value of the pleat, diverse studies on contemporary men's costumes shall help to attempt to set up a basis for the new mode of men's costume. The pleat, a component in the costume since the ancient times, had unique characteristics including functionality, a sense of volume, directing effect that is caused by line repetitions and formativeness that results through elasticity. First, the aesthetics of the pleat before the 20th century shows rhythmic sense through the repetition of the pleat line as shown in the drape type costume, and it also shows a sense of volume as the pleat is moved along the motion of the body. Second, it shows functionality as the expansion of space moves in accordance with the motion of body sets up an internal space of the costume that facilitates body motion. Third, the pleat extends two dimension space into three dimension space using its elasticity. It exaggerates specific parts of the costume while ignoring body shape in order to symbolize status and authority of men. Fourth, it unifies the costume by wrapping the body by using quadrangle cloths with drapers, and expanding the silhouette with the pleat artificially to conceal the physical character and personality of the wearer. The physical character of the wearer disappears into the space made by the pleat. The pleat reveals the voluptuous beauty within.

신경망을 이용한 반복운동 검출 (Detection of Repetition Motion Using Neural network)

  • 유병현;허경용
    • 한국정보통신학회논문지
    • /
    • 제21권9호
    • /
    • pp.1725-1730
    • /
    • 2017
  • 가속도 센서와 자이로스코프 센서는 반복운동 검출을 위해 사용하는 대표적인 센서로써 다양한 운동 성분을 분석하는데 활용되어 왔다. 하지만 이 두 센서는 잡음 민감성과 오차가 누적되는 문제점을 가지고 있다. 이와 같은 하드웨어적인 문제점을 극복하기 위해, 두 센서를 함께 사용하려는 시도가 있어왔고, 상보필터는 가속도 센서와 자이로스코프 센서의 단점은 최소화하고 장점을 극대화함으로써 두 센서가 가지는 문제점을 완화시키는 성공적인 결과를 보여주었다. 이 논문에서는 상보필터에 신경망을 도입함으로써 상보필터로 처리할 수 없는 여러 변수를 사전에 학습을 통하여 생성한 망을 이용해서 처리하는 개선된 방법을 소개한다. 신경망은 다양한 경우의 수를 미리 학습하여 예측하지 못한 환경 혹은 상황에도 정확한 측정이 가능한 알고리듬이다. 제안한 방법은 반복운동을 처음, 중간, 끝 세 개의 영역으로 분류하여 신경망을 적용한다. 그 결과 영역별 인식률은 96.35%, 98.77%, 96.92%이고 이를 바탕으로 측정한 정확도는 97.18%임을 실험을 통해 확인할 수 있다.

The Effect of Exercise Intensity on Muscle Activity and Kinematic Variables of the Lower Extremity during Squat

  • Jung, Jae-Hu;Chae, Woen-Sik
    • 한국운동역학회지
    • /
    • 제27권3호
    • /
    • pp.197-203
    • /
    • 2017
  • Objective: The purpose of this study was to determine how exercise intensity affects muscle activity and kinematic variables during squat. Method: Fifteen trainers with >5 years of experience were recruited. For the electromyography (EMG) measurements, four surface electrodes were attached to both sides of the lower extremity to monitor the rectus femoris (RF) and biceps femoris. Three digital camcorders were used to obtain three-dimensional kinematics of the body. Each subject performed a squat in different conditions (40% one-repetition maximum [40%1RM], 60%1RM, and 80%1RM). For each trial being analyzed, three critical instants and two phases were identified from the video recording. For each dependent variable, one-way analysis of variance with repeated measures was used to determine whether there were significant differences among the three different conditions (p<.05). When a significant difference was found, post hoc analyses were performed using the contrast procedure. Results: The results showed that the average integrated EMG values of the RF were significantly greater in 80%1RM than in 40%1RM during the extension phase. The temporal parameter was significantly longer in 80%1RM than in 40%1RM and 60%1RM during the extension phase. The joint angle of the knee was significantly greater in 80%1RM than in 40%1RM at flexion. The range of motion of the knee was significantly less in 80%1RM than in 40%1RM and 60%1RM during the flexion phase and the extension phase. The angular velocity was significantly less in 80%1RM than in 40%1RM and 60%1RM during the extension phase. Conclusion: Generally, the increase of muscle strength decreases the pace of motion based on the relation between the strength and speed of muscle. In this study, we also found that the increase of exercise intensity may contribute to the increase of the muscle activity of the RF and the running time in the extension phase during squat motion. We observed that increased exercise intensity may hinder the regulation of the range of motion and joint angle. It is suitable to perform consistent movements while controlling the proper range of motion to maximize the benefit of resistance training.

테오얀센의 자율적 기계 생명체와 다리 메커니즘 (Theo Jansen's Autonomous Mechanical Life and Leg Mechanism)

  • 김태은
    • 문화기술의 융합
    • /
    • 제6권1호
    • /
    • pp.23-29
    • /
    • 2020
  • 기계가 움직일 때의 동작들은 일정한 원리에 의해 움직이기 때문에 아무리 복잡하고 다양한 기계라 할지라도 기계의 운동을 지배하는 근원적 원리가 있다. 자율적 움직임은 반복을 피할 수 있고, 더 인간적이며 더 자연적인 요소에 근접하는 길이다. 복제가 아닌 독창적인 움직임은 더더욱 그러하다. 따라서 현재, 기계의 역동성은 인간의 참여에 의해 더욱 다감각적으로 표현될 수 있는 가능성에 도전하고 있으며 사실과 복제의 경계에서 그 표현영역을 점점 확대시키고 있다. 테오얀센의 작품들은 각각의 시기별로 다른 환경에 적응토록 변화하여 그의 수십 년에 걸친 연구는 초기에서 현재까지 계속 진화되고 있음을 알 수 있다. 그 진화의 초점은 무엇보다 개체를 구성하는 부품들 간의 유기적 결합이 가진 원리로부터 반복되는 원형운동과 수평적 왕복운동이라는 동일한 근원지를 가지고 있음을 알 수 있다.

무윤활 수직-수평 복합하중 조건에서 재료조합에 따른 마모특성 변화에 관한 실험적 연구 (Experimental Study on Wear Behavior of Material Pairs under Normal and Sliding Mixed Loading Conditions)

  • 최성우;민준기;정일욱;박상후
    • 한국정밀공학회지
    • /
    • 제26권11호
    • /
    • pp.131-137
    • /
    • 2009
  • A pair of connectors for transferring torque is widely used in various types of a mechanical system. By the repetition of mechanical contact between a pair of connector, wear occurs easily. This kind of defect sometimes can cause a serious problem of health in case of the connector is used in a refrigerator. In this work, the material combination of connectors was experimentally studied to reduce the amount of wear; for the combination of connectors, various types of engineering materials including polyacetal, polycabonate, stainless steel (STS-304), NiP coated STS-304, and STS-310 were evaluated to check each wear behavior. Also an effective method of wear test was suggested for precise controlling of wear conditions such as contact area, contact force, and relative motion speed. From the test results, it was found out that a pair of polyacetal to STS-304 and STS-310 showed the lowest specific wear rates among other pairs.