• 제목/요약/키워드: Motion error measurement

검색결과 217건 처리시간 0.025초

자동 측정이 가능한 전용 캠 프로파일 측정 시스템 개발 (Development of Automatic Cam Profile Measurement System)

  • 정황영;이현석;박태민;신우철;고준빈;홍준희
    • 한국공작기계학회논문집
    • /
    • 제17권1호
    • /
    • pp.106-112
    • /
    • 2008
  • In this paper, It does the profile measurement of the cam of diesel engine SOHC of the actual object. It uses the measurement of run-out method. This method is that the surface of the object is measured by the sensor when the object rotate, and calculated and displayed by the computer the signal which acquired by sensor. When we acquire the signals, we have two error because of motion and contacting between cam and probe. In this paper, we compensate the motion error while simply liner equation. And we have a solution that we change the figure of probe when we have a contacting error. We compared the data measuring on developed automatic cam profile measuring system with the data measured on CMM.

Four Degree-of-Freedom Geometric Error Measurement System with Common-Path Compensation for Laser Beam Drift

  • Qibo, Feng;Bin, Zhang;Cuifang, Kuang
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제9권4호
    • /
    • pp.26-31
    • /
    • 2008
  • A precision four-degree-of-freedom measurement system has been developed for simultaneous measurement of four motion errors of a linear stage, which include straightness and angular errors, The system employs a retro-reflector to detect the straightness errors and a plane mirror to detect the angular errors. A common-path compensation method for laser beam drift is put forward, and the experimental results show that the influences of beam drift on four motion errors can be reduced simultaneously. In comparison with the API 5D laser measuring system, the accuracy for straightness measurement is about ${\pm}1.5{\mu}m$ within the measuring range of ${\pm}650{\mu}m$, and the accuracy for pitch and yaw measurements is about ${\pm}1.5$ arc-seconds within the range of ${\pm}600$ arc-seconds.

서브미크론 진직도 측정장치 개발 (Development of a Submicron Order Straightness Measuring Device)

  • 박천홍;정재훈;김수태;이후상
    • 한국정밀공학회지
    • /
    • 제17권5호
    • /
    • pp.124-130
    • /
    • 2000
  • For measuring out the submicron order straightness, a precision measuring device is developed in this paper. The device is constructed with a hydrostatic feed table and a capacitive type sensor which is mounted to the feed table. Straightness is acquired as substracting the motion error of feed table from the measured profile with probe. Motion error of feed table is simultaneously compensated upto 0.120${\mu}{\textrm}{m}$ of linear motion error and 0.20arcsec of angular motion error using the active controlled capillary. Reversal method and strai호t-edge is used fur estimating the measuring accuracy and from the experimental result, it is verified that the device has the measuring accuracy 0.030m. Also, through the practical application on the measurement of ground surface, it is confirmed that the device is very effective to measure the submicron order straightness.

  • PDF

광용적맥파(PPG)를 이용한 호흡수 측정에 있어서 동잡음을 이용한 정확도 향상 (Accuracy improvement of respiration rate based on photo-plethysmography by enhancing motion artifact)

  • 허영정;윤길원
    • 센서학회지
    • /
    • 제17권6호
    • /
    • pp.447-453
    • /
    • 2008
  • Respiration rate is one of the important vital signs. Photo-plethysmography (PPG) measurement especially on a finger has been widely used in pulse oximetry and also used in estimating respiration rate. It is well known that PPG contains respiration-induced intensity variation (RIIV) signal. However, the accuracy of finger PPG method has been controversial. We introduced a new technique of enhancing motion artifact by respiration. This was achieved simply by measuring PPG on the thorax. We examined the accuracy of these two PPG methods by comparing with two existing methods based on thoracic volume and nostril temperature changes. PPG sensing on finger tip, which is the most common site of measurement, produced 6.1 % error. On the other hand, our method of PPG sensing on the thorax achieved 0.4 % error which was a significant improvement. Finger PPG is sensitive to motion artifact and it is difficult to recover fully small respiratory signal buried in waveform dominated by absorption due to blood volume changes. Thorax PPG is poor to represent blood volumes changes since it contains substantial motion artifact due to respiration. Ironically, this inferior quality ensures higher accuracy in terms of respiration measurement. Extreme low-cost and small-sized LED/silicon detector and non-constrained reflection measurement provide a great candidate for respiration estimation in ubiquitous or personal health monitoring.

평면 오차 보정 가공을 위한 측정 방법에 관한 연구 (A Measurement Method to Compromise Surface Error in Machined Workpieces)

  • 장문주;홍성욱;박천홍
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.409-412
    • /
    • 2002
  • This paper presents a measurement method to compromise surface error in surface machining processes. In order to compromise the surface error in machining process, on-machine measurement is essential. There are two kinds of on-machine measurement methods available to measure the surface errors in flat workpieces: i.e., surface scanning method and sensor scanning method. However, motion errors are inevitably engaged in both methods. This paper proposes a new idea to measure the surface error for error compensation. The measurement system consists of a laser, a CCD camera and processing system, a carrier system with a stylus, and some optical units. The experimental results show that the proposed method is useful to compensate the surface errors of machined workpieces.

  • PDF

레이저 관성항법장치에서 링레이저 자이로 디더 운동에 의한 가속도계 공진이 자체 정렬/항법 성능에 미치는 영향 분석 (Self-Alignment/Navigation Performance Analysis in the Accelerometer Resonance State Generated by Dither Motion of Ring Laser Gyroscope in Laser Inertial Navigation System)

  • 김천중;임경아;김선아
    • 한국군사과학기술학회지
    • /
    • 제24권6호
    • /
    • pp.577-590
    • /
    • 2021
  • In this paper, we theoretically analyzed the self-alignment/navigation performance in the accelerometer resonance state generated by dither motion of ring laser gyroscope in LINS and verified it through simulation. As a result of analysis, it is confirmed that the amplitude of the accelerometer measurement amplified in the accelerometer resonance state is decreased in the process of sampling per the navigation calculation period and that frequency is changed by the aliasing effect too. It was also analysed that the attitude error in self-alignment is determined by the amplitude/frequency of the accelerometer measurement, the gain of the self-alignment loop, and the velocity and position error in the navigation is determined by the amplitude/frequency/phase error of the accelerometer measurement. This analysis and simulation results show that the self-alignment and navigation performance is not be degraded only when the amplification factor of the accelerometer measurement in the accelerometer resonance state is 3 or less

피치운동을 이용한 정밀 다위치 정렬기법 개발 (Development of the Precise Multi-Position Alignment Method using a Pitch Motion)

  • 이정신
    • 한국군사과학기술학회지
    • /
    • 제13권4호
    • /
    • pp.708-715
    • /
    • 2010
  • In Strapdown Inertial Navigation System, alignment accuracy is the most important factor to determine the performance of navigation. However by an existing self-alignment method, it takes a long time to acquire the alignment accuracy that we want. So, to attain the desired alignment accuracy in as little as $\bigcirc$ minutes, we have developed the precise multi-position alignment method. In this paper, it is proposed a inertial measurement matching transfer alignment method among alignment methods to minimize the alignment error in a short time. It is based on a mixed velocity-DCM matching method be suitable to the operating environment of vertical launching system. The compensation methods to reduce misalign error, especially azimuth angle error incurred by measurement time-delay error and body flexure error are analyzed and evaluated with simulation. This simulation results are finally confirmed by experimentations using FMS(Flight Motion Simulator) in Lab and the integration test to follow the fire control mission.

RLG Trapping 신호처리 기법의 성능개선에 관한 연구 (A study on the Performance Improvement in Trapping Signal Processing Method of RLG)

  • 유기정;김천중;심규민
    • 한국항공우주학회지
    • /
    • 제36권10호
    • /
    • pp.1003-1010
    • /
    • 2008
  • 본 논문은 RLG의 신호처리 기법인 Trapping 기법 적용시 각속도와 가속도의 측정시점 불일치에 의해 발생되는 오차를 보상하는 기법에 관한 연구이다. RLG의 대표적인 신호처리 기법인 Stripping 신호처리 기법과 Trapping 신호처리 기법에 대하여 각 기법의 오차요인을 분석하고 이에 대한 모델링을 수행하였다. 그리고 Trapping 기법 적용시 각속도와 가속도 측정시점 불일치에 의해 발생되는 오차에 대한 모델링을 통하여 항법오차에 미치는 영향을 분석하였으며 이를 감소시키기 위한 새로운 신호처리 기법을 제안하고 시뮬레이션 및 시험을 통하여 이에 대한 성능분석 결과를 제시하였다. 성능 분석결과 본 논문에서 제시한 신호처리 기법이 기존의 방법에 비하여 항법오차를 크게 감소시키는 것을 확인할 수 있었다.

Validity and Reliability of an Inertial Measurement Unit-Based 3D Angular Measurement of Shoulder Joint Motion

  • Yoon, Tae-Lim
    • The Journal of Korean Physical Therapy
    • /
    • 제29권3호
    • /
    • pp.145-151
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the validity and reliability of the measurement of shoulder joint motions using an inertial measurement unit (IMU). Methods: For this study, 33 participants (32 females and 1 male) were recruited. The subjects were passively positioned with the shoulder placed at specific angles using a goniometer (shoulder flexion $0^{\circ}-170^{\circ}$, abduction $0^{\circ}-170^{\circ}$, external rotation $0^{\circ}-90^{\circ}$, and internal rotation $0^{\circ}-60^{\circ}$ angles). Kinematic data on the shoulder joints were simultaneously obtained using IMU three-dimensional (3D) angular measurement (MyoMotion) and photographic measurement. Test-retest reliability and concurrent validity were examined. Results: The MyoMotion system provided good to very good relative reliability with small standard error of measurement (SEM) and minimal detectable change (MDC) values from all three planes. It also presented acceptable validity, except for some of shoulder flexion, shoulder external rotation, and shoulder abduction. There was a trend for the shoulder joint measurements to be underestimated using the IMU 3D angular measurement system compared to the goniometer and photo methods in all planes. Conclusion: The IMU 3D angular measurement provided a reliable measurement and presented acceptable validity. However, it showed relatively low accuracy in some shoulder positions. Therefore, using the MyoMotion measurement system to assess shoulder joint angles would be recommended only with careful consideration and supervision in all situations.

회절격자 간섭계를 이용한 초정밀 스테이지의 6 자유도 운동 특성 측정 (Measurement of a Six-degree-of-freedom Dynamic Characteristics using Angle Sensor-Implemented Grating Interferometry)

  • 이차범;김규하;이선규
    • 한국정밀공학회지
    • /
    • 제29권8호
    • /
    • pp.906-912
    • /
    • 2012
  • This paper presents the new method for a six-degree-of-freedom (DOF) motion measurement and those dynamic characterizations in an ultraprecision linear stage using angle sensor-implemented grating interferometry. It consists of a diffractive optical element, a corner cube, four separate two-dimensional position sensitive detectors, four photodiodes and auxiliary optics components. From the previous study, it was confirmed that the proposed optical system could measure a six-DOF motion error in a linear stage. In this article, six-DOF motion dynamic characteristics of the stage were investigated through the step response and with respect to the conditions with a different speed of a slide table. As a result, the natural frequency and damping ratio according to a six-DOF direction was obtained. Also, it was seen that the speed of slide table had an significant effect on a six-DOF displacement motion, especially, X, which was considered as the effect of friction mechanism and local elastic mechanical deformation in a slide guide.