Development of a Submicron Order Straightness Measuring Device

서브미크론 진직도 측정장치 개발

  • Published : 2000.05.01

Abstract

For measuring out the submicron order straightness, a precision measuring device is developed in this paper. The device is constructed with a hydrostatic feed table and a capacitive type sensor which is mounted to the feed table. Straightness is acquired as substracting the motion error of feed table from the measured profile with probe. Motion error of feed table is simultaneously compensated upto 0.120${\mu}{\textrm}{m}$ of linear motion error and 0.20arcsec of angular motion error using the active controlled capillary. Reversal method and strai호t-edge is used fur estimating the measuring accuracy and from the experimental result, it is verified that the device has the measuring accuracy 0.030m. Also, through the practical application on the measurement of ground surface, it is confirmed that the device is very effective to measure the submicron order straightness.

Keywords

References

  1. 淸野 慧, 高 偉, '多点法によるソフトウェアデ-タムとの誤差評價,' 日本機械學會論文集(C編) 58-551, pp. 2262-2267, 1992
  2. 山口城治, '改良逐次3点法による直線運動精度の計側,' 日本精密工學會, 59-5, pp. 773-778, 1993
  3. 박천흥, 송영찬, 김수태, 이후상, '능동제어모세관을 이용한 유정압테이블의 운동정도 향상,' 한국정밀공학회지 제14권 제12호, pp. 114-120, 1997
  4. 박천홍, 김인찬, 정윤교, 이후상, '고정밀이송을 위한 볼스크류용 체결기구에 관한 연구,' 한국정밀공학회지 제14권 제5호, pp. 157-164, 1997