A study on shield on the center of gravity moving designed for high efficiency operation for the gamma-ray imaging detector (감마선 영상화 장치용 고효율 동작을 위한 차폐체 무게중심 이동 설계에 관한 연구)

  • Park, Gang-teck;Lee, Nam-ho;Hwang, Young-gwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.948-949
    • /
    • 2016
  • In this study, we perform the structure change of the shielding this is applied for gamma-ray detectors for imaging of gamma-ray source. Through previous studies, we implemented the commercially available gamma-ray imaging apparatus similar to the shielding body but weight reduction, center of gravity moving of shield. In this paper, we changed a shield for motion control detectors efficient movement. We performed the MCNP simulation of shield design and then we obtained the results of reducing the weight of the 17% and moving of center of gravity the shield center.

  • PDF

Development of a truncation artifact reduction method in stationary inverse-geometry X-ray laminography for non-destructive testing

  • Kim, Burnyoung;Yim, Dobin;Lee, Seungwan
    • Nuclear Engineering and Technology
    • /
    • v.53 no.5
    • /
    • pp.1626-1633
    • /
    • 2021
  • In an industrial field, non-destructive testing (NDT) is commonly used to inspect industrial products. Among NDT methods using radiation sources, X-ray laminography has several advantages, such as high depth resolution and low computational costs. Moreover, an X-ray laminography system with stationary source array and compact detector is able to reduce mechanical motion artifacts and improve inspection efficiency. However, this system, called stationary inverse-geometry X-ray laminography (s-IGXL), causes truncation artifacts in reconstructed images due to limited fields-of-view (FOVs). In this study, we proposed a projection data correction (PDC) method to reduce the truncation artifacts arisen in s-IGXL images, and the performance of the proposed method was evaluated with the different number of focal spots in terms of quantitative accuracy. Comparing with conventional techniques, the PDC method showed superior performance in reducing truncation artifacts and improved the quantitative accuracy of s-IGXL images for all the number of focal spots. In conclusion, the PDC method can improve the accuracy of s-IGXL images and allow precise NDT measurements.

An Evaluation Method of X-ray Imaging System Resolution for Non-Engineers (비공학도를 위한 X-ray 영상촬영 시스템 해상력 평가 방법)

  • Woo, Jung-Eun;Lee, Yong-Geum;Bae, Seok-Hwan;Kim, Yong-Gwon
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.309-314
    • /
    • 2012
  • Nowadays, digital Radiography (DR) systems are widely used in clinical sites and substitute the analog-film x-ray imaging systems. The resolution of DR images depends on several factors such as characteristic contrast and motion of the object, the focal spot size and the quality of x-ray beam, x-ray scattering, the performance of the DR detector (x-ray conversion efficiency, the intrinsic resolution). The DR detector is composed of an x-ray capturing element, a coupling element and a collecting element, which systematically affect the system resolution. Generally speaking, the resolution of a medical imaging system is the discrimination ability of anatomical structures. Modulation transfer function (MTF) is widely used for the quantification of the resolution performance for an imaging system. MTF is defined as the frequency response of the imaging system to the input of a point spread function and can be obtained by doing Fourier transform of a line spread function, which is extracted from a test image. In clinic, radiologic technologists, who are in charge of system maintenance and quality control, have to evaluate or make routine check on their imaging system. However, it is not an easy task for the radiologic technologists to measure MTF accurately due to lack of their engineering and mathematical backgrounds. The objective of this study is to develop and provide for radiologic technologists a medical system imaging evaluation tool, so that they can measure and quantify system performance easily.

Evaluation of Spatial Uniformity about Resolution and Sensitivity of a 'fixed focusing type SPECT' (고정식 초점형 SPECT에 있어, 선예도와 감도의 공간 균일성에 대한 평가)

  • Kim, Jaeil;Lim, Jeongjin;Cho, Seongwook;Noh, Kyeongwoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.54-58
    • /
    • 2019
  • Purpose At now, there are many kind of dedicated heart SPECT machine in clinical nuclear medicine. Among those, the fixed focusing type SPECT can make a good quality, quantity image because a detectors of this SPECT arranged forward a special ROI and didn't rotate around of body. So, in this paper, we will evaluate a spatial uniformity about resolution and sensitivity at a same plane of a fixed focusing type SPECT. Materials and Methods We used D-SPECT as a fixed focusing type SPECT and Cario MD as a rotated parallel type SPECT to comparing each other. We injected $^{99m}Tc(14.8MBq/1cc)$ to 10 capillary tube (diameter=1mm), and we set those line sources a tfield of view of each SPECT. And then we acquired SPECT date, we applied are construction by recommended methods. By using two tomography images, we calculated a full width of half maximum as a resolution and total counts as a sensitivity, and we compared a CV (coefficientofvariation) values between two images as a spatial uniformity. Results In case of D-SPECT, a CV of resolution and sensitivity are 7.45%, 12.34%. In case of Cario MD, an CV of resolution and sensitivity are 12.49%, 21.84% Conclusion As a results, CV of resolution and sensitivity of a fixed focusing type SPECT is 67.75%, 77.00% higher than ones of a rotated parallel type SPECT. It means that a fixed focusing type SPECT is more uniformed, because this new SPECT can reduce a motion blur artifact by rotating detector around body, also all of detector that made by semiconductor arrange forward a special FOV like heart.

Implementation of Intelligent Image Surveillance System based Context (컨텍스트 기반의 지능형 영상 감시 시스템 구현에 관한 연구)

  • Moon, Sung-Ryong;Shin, Seong
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.3
    • /
    • pp.11-22
    • /
    • 2010
  • This paper is a study on implementation of intelligent image surveillance system using context information and supplements temporal-spatial constraint, the weak point in which it is hard to process it in real time. In this paper, we propose scene analysis algorithm which can be processed in real time in various environments at low resolution video(320*240) comprised of 30 frames per second. The proposed algorithm gets rid of background and meaningless frame among continuous frames. And, this paper uses wavelet transform and edge histogram to detect shot boundary. Next, representative key-frame in shot boundary is selected by key-frame selection parameter and edge histogram, mathematical morphology are used to detect only motion region. We define each four basic contexts in accordance with angles of feature points by applying vertical and horizontal ratio for the motion region of detected object. These are standing, laying, seating and walking. Finally, we carry out scene analysis by defining simple context model composed with general context and emergency context through estimating each context's connection status and configure a system in order to check real time processing possibility. The proposed system shows the performance of 92.5% in terms of recognition rate for a video of low resolution and processing speed is 0.74 second in average per frame, so that we can check real time processing is possible.

Development of the Automated Ultrasonic Testing System for Inspection of the flaw in the Socket Weldment (소켓 용접부 결함 검사용 초음파 자동 검사 장비 개발)

  • Lee, Jeong-Ki;Park, Moon-Ho;Park, Ki-Sung;Lee, Jae-Ho;Lim, Sung-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.3
    • /
    • pp.275-281
    • /
    • 2004
  • Socket weldment used to change the flow direction of fluid nay have flaws such as lack of fusion and cracks. Liquid penetrant testing or Radiography testing have been applied as NDT methods for flaw detection of the socket weldment. But it is difficult to detect the flaw inside of the socket weldment with these methods. In order to inspect the flaws inside the socket weldment, a ultrasonic testing method is established and a ultrasonic transducer and automated ultrasonic testing system are developed for the inspection. The automated ultrasonic testing system is based on the portable personal computer and operated by the program based Windows 98 or 2000. The system has a pulser/receiver, 100MHz high speed A/D board, and basic functions of ultrasonic flaw detector using the program. For the automated testing, motion controller board of ISA interface type is developed to control the 4-axis scanner and a real time iC-scan image of the automated testing is displayed on the monitor. A flaws with the size of less than 1mm in depth are evaluated smaller than its actual site in the testing, but the flaws larger than 1mm appear larger than its actual size on the contrary. This tendency is shown to be increasing as the flaw size increases. h reliable and objective testing results are obtained with the developed system, so that it is expected that it can contribute to safety management and detection of repair position of pipe lines of nuclear power plants and chemical plants.

A Study on Basic Modeling Method for MTF Analysis of Observation Satellites (관측위성의 MTF 해석을 위한 기본 모델링 기법 연구)

  • Kim, Do-Myung;Kim, Deok-Ryeol;Kim, Nak-Wan;Suk, Jin-Young;Kim, Hee-Seob;Kim, Gyu-Sun;Hyun, Young-Mok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.5
    • /
    • pp.472-482
    • /
    • 2008
  • A modulation transfer function(MTF) tree is established to estimate the overall MTF of an observation satellite and to analyze the image performance. Basic MTF models relevant to each MTF tree component are represented as mathematical relationship between optics-structural dynamics, thermal deformation, attitude and dynamic characteristics of a satellite and the effects due to the space environment. The Basic MTF models consist of diffraction limited MTF with central obscuration, aberration, defocus, line-of-sight(LOS) jitter, linear motion, detector integration, and so forth. Performance estimation is demonstrated for a virtual earth-observation satellite in order to validate the constructed modeling method. The proposed models enable the system engineers to calculate the overall system MTF and to determine the crucial design parameters that affect the image performance in the conceptual design phase of an observation satellite.

Effect of the Incident Optical Spot Size Upon the Quadrant Photodetector on the Optical Displacement Detection Sensitivity (4분할 광 검출기 상의 광점 크기가 변위 측정감도에 미치는 영향)

  • Lee, Eun-Joong;Lee, Jin-Woo;Kouh, Tae-Joon
    • Journal of the Korean Magnetics Society
    • /
    • v.18 no.2
    • /
    • pp.71-74
    • /
    • 2008
  • In this paper, we have measured the effect of the optical spot size, incident upon the quadrant photodetector, on the optical displacement sensitivity of the optical beam deflection technique. We have built an optical displacement detection system based on the optical beam deflection method using 3 mW He-Ne laser and measured the displacement sensitivity with changing the optical spot size on the quadrant photodetector. We have also calculated the changes in the optical displacement sensitivity as a function of the incident laser spot size by modeling a circular optical spot with constant laser intensity. Our experimental and theoretical studies show that the optical displacement sensitivity increases with the decrease in the optical spot size. This suggests that in the design of the optical motion detection systems with sub-nanometer sensitivity, the displacement sensitivity can be optimized by reducing the size of the incident optical spot on the detector.

Customized Estimating Algorithm of Physical Activities Energy Expenditure using a Tri-axial Accelerometer (3축 가속도 센서를 이용한 신체활동에 따른 맞춤형 에너지 측정 알고리즘)

  • Kim, Do-Yoon;Jeon, So-Hye;Kang, Seung-Yong;Kim, Nam-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.12
    • /
    • pp.103-111
    • /
    • 2011
  • The research has increased the role of physical activity in promoting health and preventing chronic disease. Estimating algorithm of physical activity energy expenditure was implemented by using a tri-axial accelerometer motion detector of the SVM(Signal Vector Magnitude) of 3-axis(x, y, z). COUNT method has been proven through experiments of validity Freedson, Hendelman, Leenders, Yngve was implemented by applying the SVM method. A total of 10 participants(5 males and 5 females aged between 20 and 30 years). The activity protocol consisted of three types on treadmill; participants performed three treadmill activity at three speeds(3, 5, 8 km/h). These activities were repeated four weeks. Customized estimating algorithm for energy expenditure of physical activities were implemented with COUNT and SVM correlation between the data.

Smoke Detection Using the Ratio of Variation Rate of Subband Energy in Wavelet Transform Domain (웨이블릿 변환 영역에서 부대역 에너지 변화율의 비를 이용한 연기 감지)

  • Kim, JungHan;Bae, Sung-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.17 no.3
    • /
    • pp.287-293
    • /
    • 2014
  • Early fire detection is very important to avoid loss of lives and material damage. The conventional smoke detector sensors have difficulties in detecting smoke in large outdoor areas. The video-based smoke detection can overcome these drawbacks. This paper proposes a new smoke detection method in video sequences. It uses the ratio of variation rate of subband energy in the wavelet transform domain. In order to reduce the false alarm, candidate smoke blocks are detected by using motion, decrease of chromaticity and the average intensity of block in the YUV color space. Finally, it decides whether the candidate smoke blocks are smokes or not by using their temporal changes of subband energies in the wavelet transform domain. Experimental results show that the proposed method noticeably increases the accuracy of smoke detection and reduces false alarm compared with the conventional smoke detection methods using wavelets.