• Title/Summary/Keyword: Motion Comparison

Search Result 1,226, Processing Time 0.029 seconds

A Comparative Study of Range of Motion With or Without Distal Interphalangeal Joint Fixation in Replantation of the Amputated Fingertips (수지 첨부 절단창의 재접합술 시 원위지 관절 고정과 운동 범위의 관계)

  • Han, Seung-Kyu;Roh, Si-Young;Kim, Jin-Soo;Lee, Dong-Chul;Ki, Sae-Hwi;Yang, Jae-Won
    • Archives of Reconstructive Microsurgery
    • /
    • v.20 no.1
    • /
    • pp.18-25
    • /
    • 2011
  • Purpose: In the process of replantation of the amputated fingertips, the primary concern was given to survival of the amputees, while the functional aspect of digits after the surgery has been easily neglected. Although an internal fixation with a K-wire is often a part of replantation of the amputated fingertips, little consideration had been given to the study of relationship between distal interphalangeal joint fixation and post operative range of motion. A comparative study in relation to post operative range of motion was done on two different groups, one group with K-wire insertion and the other group without a K-wire insertion at the distal interphalangeal joint. Materials and Methods: The study was done on the cases of a single digit amputation conducted at our institute (the age in the range of 10 to 60) in about four-year of time span from March of 2005 to March of 2009. The cases with a thumb replantation, osteomyelitis or articular surface injury have been excluded from this study. The cases of both head and shaft fracture, except the insertion site of tendon, of distal phalanx of internal fixation with a single K-wire were reviewed for this study. A group of 24 cases without distal interphalangeal joint fixation in comparison to a group of 22 cases with distal interphalangeal joint fixation was reviewed to assess the postoperative range of motion at distal interphalangeal joint on the 6th week after the surgery. And, on the 30th month after the surgery, a group of 10 cases without distal interphalangeal joint fixation in comparison to a group of 10 cases with joint fixation was reviewed. A K-wire was removed in about 5 weeks after the fracture was reunited under the radiographic image, immediately followed by a physical therapy. Result: The active range of motion for a group without interphalangeal joint fixation was measured $49.0^{\circ}$ on average, while $28.6^{\circ}$ was measured for a group with interphalengeal fixation on the 6th week after the surgery. On the 30th month after the surgery, the active range of motion was measured $52.0^{\circ}$ and $55.0^{\circ}$ on average for a group without and with interphalangeal fixation respectively. Conclusion: In the process of replantation of the amputated fingertips, short-term(on the 6th week) improvement of postoperative active motion of range can be expected in the cases without distal interphalangeal fixation in comparison to the cases of interphalangeal joint fixation with a K-wire. However, there seems to be no difference on motion of range in a long-term (on the 30th month) follow up period.

  • PDF

Comparison of the Character Movements from Key-frame and Motion Capture Animation (키 프레임과 모션캡처 애니메이션의 캐릭터 움직임 비교)

  • Yoo, Mi-Ohk;Park, Kyoung-Ju
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.9
    • /
    • pp.74-83
    • /
    • 2008
  • In animation films, the movements of characters are exaggerated and comical. Traditional key-frame animation techniques allow to control exaggeration and comicality of characters at animators' wills. But, recently introduced motion capture techniques have limits on representing comicality and exaggeration although it is convenient to capture subjects' natural looks. This paper chooses two animations from key-frame and motion capture techniques and looks into comicality and exaggeration of characters by analyzing movements and motion of them Movements are classified as four fundamental motion elements - running, jump, gesture and walking - and are analyzed to compare the way of representation from two films. By studying similarity and differentiation of movements of two films, this paper discusses the advantages and disadvantages of key-frame and motion capture techniques in terms of exaggeration and comicality. Comparison of the character movements from two techniques shows that there are common differentiations of those movements.

Characteristics Comparison of Motion Controllers through Experiments (실험을 통한 모션제어기의 특성비교)

  • Jung, Seung-Hyun;Wang, Jun;Han, Chang-Wook;Park, Jung-Il
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.11
    • /
    • pp.1094-1102
    • /
    • 2008
  • Through the motion control experiment using Industrial Emulator(Model 220 by ECP), the performance comparison of three kinds of controllers such as PID, RIC and LQR was carried out. It was shown that RIC has the best performance in the presence of disturbances such as step one, sinusoidal one and Coulomb friction for the rigid body. LQR using feedback state variables has the best tracking performance far the flexible body. The performance of PID controller is low compared to other controllers, but the design process is simple. The most advanced controller is LQR. In order to attenuate disturbance, an additional state observer should be used to estimate it, making more complex control system. RIC lies between PID and LQR in view of complexity of design. Even though RIC is not complicated, it has good disturbance rejection ability and less tracking error. By considering these aspects, the RIC is suggested as high precision controller to be used in motion control system.

Comparison of the 6-DOF Motion Sensor and Stain Gauge Data for Ice Load Estimation on IBRV ARAON (쇄빙연구선 ARAON호의 빙하중 추정을 위한 6자유도 운동계측 및 스트레인 게이지 데이터의 비교 분석)

  • Min, Jung Ki;Cheon, Eun-Jee;Kim, Jin Myung;Lee, Sang Chul;Choi, Kyungsik
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.53 no.6
    • /
    • pp.529-535
    • /
    • 2016
  • This study focuses on the comparison of measured data from 6-DOF motion sensor and strain gauge installed in the IBRV ARAON during 2015 summer voyage in the Arctic. Procedures to calculate the global ice load from MotionPak II inertial measurement system and the local load from stain gauge system are discussed. The ship's speed and peak load are determined in the concept of an ice collision "event". It is found that the peak values in the global ice calculated form whole ship motion analysis fall in the range of 1.5~3 times of the local ice load based in strain gauge measurement.

ITO Wet Etch Properties in an In-line Wet Etch/Cleaning System by using an Alternating Movement of Substrate (기판의 왕복 운동을 이용한 인라인 식각세정장치 내 ITO 식각특성)

  • Hong, Sung-Jae;Kwon, Sang-Jik;Cho, Eou-Sik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.8
    • /
    • pp.715-718
    • /
    • 2008
  • An in-line wet etch/cleaning system was established for the research and development in wet etch process. The system was equipped with a reverse moving system for the reduction in the size of the in-line wet etch/cleaning system and it was possible for the glass substrate to be moved back and forth and alternated in a wet etch bath. For the comparison of the effect of the normal motion and that of the alternating motion on the in-line wet etch process, indium tin oxide(ITO) pattern was obtained through both wet etch process conditions. The results showed that the alternating motion is not inferior to the normal motion in etch rate and in etch uniformity. It is concluded that the alternating motion is possible to be applied to the in-line etch process.

Analysis of the Motion Picture Quality of Stereoscopic Three-dimensional Images

  • Choi, Hee-Jin;Jung, Jae-Hyun;Kim, Hwi;Lee, Byoung-Ho
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.383-387
    • /
    • 2010
  • The stereoscopic three-dimensional (3D) display provides a 3D image by inducing binocular disparity for the observers who wear special glasses. With the rapid progress in flat panel display technologies, the stereoscopic 3D display is becoming a new benefit-model of the current display industry, and several kinds of commercial stereoscopic 3D products have been released and are attracting people. Nowadays, the motion picture quality of the 3D image becomes as important as resolution or luminance since most of the commercial 3D products are 3D televisions or 3D monitors which are required to display a clear motion 3D image. In this paper, an analysis and simulation of the motion picture quality of stereoscopic 3D image is proposed, and a comparison of the motion picture performance among the current stereoscopic 3D technologies is also provided.

Compliance Analysis of Constrained Spatial Flexible Manipulators (구속받는 3차원 유연 매니퓰레이터의 컴플라이언스 해석)

  • Kim, Jin-Soo
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.3
    • /
    • pp.91-96
    • /
    • 2006
  • The aim of this paper is to clarify the structural compliance of the constrained spatial flexible manipulator and to develop the force control by using the compliance of the links. Using the dependency of elastic deflections of links on contact force, vibrations for constrained vertical motion have been suppressed successfully by controlling the position of end-effector. However, for constrained horizontal motion, the vibrations cannot be suppressed by only controlling position of end-effector. We present the experimental results for constrained vertical motion, and constrained horizontal motion. Finally, a comparison between these results is presented to show the validity of link compliance.

A Comparison of the Moving Time about Gantry (겐트리에 대한 구동 시간의 비교)

  • Kim, Soon Ho;Kim, Chi Su
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.6 no.3
    • /
    • pp.135-140
    • /
    • 2017
  • SMT is an equipment that picks up electronic components and does precise placing onto PCBs. In order to do this, it stops in front of a camera installed in the middle to go over vision inspection. And after that it is move for placing. In this paper, We compared to the method of the placing after inspect to the stoped component and the moving component in front of the camera. As a result, This paper shows that the time efficiency of the fly-motion was increased by 9 percent than the stop-motion.