• Title/Summary/Keyword: Monte-Carlo와 Calibration 방법

Search Result 19, Processing Time 0.03 seconds

Comparative Analysis on the Labor Market Outcomes between IT Graduates and Non-IT Graduates (IT학과와 비IT학과 졸업자간의 노동시장성과 비교분석연구)

  • Lee, Sang-Don;Lee, Sang-Jun;Lee, Ee-Kyu;Lee, Jung-Mann
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.5
    • /
    • pp.355-364
    • /
    • 2009
  • This study investigated the labor market outcomes between IT graduates and non-IT graduates in terms of employment, wage, and work period through Monte-Carlo and Calibration method. The empirical result of the movement from work to unemployment implied that IT major graduates have stable work period irrespective of continuous employment, and but the number of work period of non-IT graduates decreases. It also showed that IT related department graduates got relatively paid more than non-IT graduates and IT major graduates was 0.8% higher wage premium than non-IT graduates.

Prediction of Stream Flow on Probability Distributed Model using Multi-objective Function (다목적함수를 이용한 PDM 모형의 유량 분석)

  • Ahn, Sang-Eok;Lee, Hyo-Sang;Jeon, Min-Woo
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.5
    • /
    • pp.93-102
    • /
    • 2009
  • A prediction of streamflow based on multi-objective function is presented to check the performance of Probability Distributed Model(PDM) in Miho stream basin, Chungcheongbuk-do, Korea. PDM is a lumped conceptual rainfall runoff model which has been widely used for flood prevention activities in UK Environmental Agency. The Monte Carlo Analysis Toolkit(MCAT) is a numerical analysis tools based on population sampling, which allows evaluation of performance, identifiability, regional sensitivity and etc. PDM is calibrated for five model parameters by using MCAT. The results show that the performance of model parameters(cmax and k(q)) indicates high identifiability and the others obtain equifinality. In addition, the multi-objective function is applied to PDM for seeking suitable model parameters. The solution of the multi-objective function consists of the Pareto solution accounting to various trade-offs between the different objective functions considering properties of hydrograph. The result indicated the performance of model and simulated hydrograph are acceptable in terms on Nash Sutcliffe Effciency*(=0.035), FSB(=0.161), and FDBH(=0.809) to calibration periods, validation periods as well.

Calibration of Parameters in QUAL2E using the Least-squares Method (최소지승법에 의한 QUAL2E 모델 반응계수 보정)

  • Kim, Kyung-Sub;Yoon, Dong-Gu;Lee, Gi-Young
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.9
    • /
    • pp.719-727
    • /
    • 2004
  • Water quality models can be applied to manage the regional water quality problems and to estimate the target and allowable pollution load in watershed effectively. The optimization of state variables in the given water quality model Is necessary to build up more effective model. The least-squares method is applied to fit field observations in QUAL2E developed by U.S. EPA, which is most widely used one in the world to simulate the stream water quality, and the optimization model with constraints is constructed to estimate the parameters. The objective function of the optimization model is solved by Solver in Microsoft Excel and Monte Carlo simulation is conducted to know the influence of parameter in conventional pollutants. It is found that this technique is easily implemented and rapidly convergent computational procedure to calibrate the parameters after appling this approach in Anyang stream located in Kyonggi province mainly.

A Study on Calibration of Neutron Moisture Gauge Using MCNP4A (MCNP4A 전산코드를 이용한 중성자 수분함량 측정기의 교정식 및 교정상수 도출방법 연구)

  • Whang, Joo-Ho;Lim, Chun-Il;Song, Jung-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.4
    • /
    • pp.289-298
    • /
    • 1997
  • Time-consuming experiments have been required in the development of neutron moisture gauge to induce a relation between the water content in soil and the neutron counts. Applying a monte carlo computer code to simulate the experiments of neutron moisture gauging may contribute to reduce time and efforts for experiments and produce a calibration equation which is more applicable to soil in general. In this study MCNP4A, a monte carlo computer code, was employed to simulate soil experiments and the simulated results were compared with experimental ones. The comparative study showed that MCNP4A is applicable to simulate the experiments and calibration equation can be obtained through simulations. Effects of dry density changes were also studied.

  • PDF

Probabilistic Calibration of Computer Model and Application to Reliability Analysis of Elasto-Plastic Insertion Problem (컴퓨터모델의 확률적 보정 및 탄소성 압착문제의 신뢰도분석 응용)

  • Yoo, Min Young;Choi, Joo Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.9
    • /
    • pp.1133-1140
    • /
    • 2013
  • A computer model is a useful tool that provides solution via physical modeling instead of expensive testing. In reality, however, it often does not agree with the experimental data owing to simplifying assumption and unknown or uncertain input parameters. In this study, a Bayesian approach is proposed to calibrate the computer model in a probabilistic manner using the measured data. The elasto-plastic analysis of a pyrotechnically actuated device (PAD) is employed to demonstrate this approach, which is a component that delivers high power in remote environments by the combustion of a self-contained energy source. A simple mathematical model that quickly evaluates the performance is developed. Unknown input parameters are calibrated conditional on the experimental data using the Markov Chain Monte Carlo algorithm, which is a modern computational statistics method. Finally, the results are applied to determine the reliability of the PAD.

Estimation of the Fundamental Matrix using a Non-linear Minimization Technique and Its Accuracy Analysis (비선형 최소화에 의한 F행렬 추정 및 정확도 분석)

  • Eom, Seong-Hun;Lee, Jong-Su
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.38 no.6
    • /
    • pp.657-664
    • /
    • 2001
  • It is possible to extract a 3D models from its multiple views using the self-calibration. Though it is possible to construct 3D models of objects from their multiple views, accuracy of 3D models depends on the fundamental matrix estimated between two views. In this paper, we show the fundamental matrix accuracy can be improved by taking a non-linear minimization technique. Furthermore, the corresponding points which are completely mismatches or have greater discrepancy errors in their locations, reduce the fundamental matrix accuracy. Thus, applying the Monte Carlo technique and the non-linear minimization Levenberg-Marquardt method to remove the outliers, we can estimate the fundamental matrix with the higher accuracy.

  • PDF

Comparison of ISO-GUM and Monte Carlo Method for Evaluation of Measurement Uncertainty (몬테카를로 방법과 ISO-GUM 방법의 불확도 평가 결과 비교)

  • Ha, Young-Cheol;Her, Jae-Young;Lee, Seung-Jun;Lee, Kang-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.7
    • /
    • pp.647-656
    • /
    • 2014
  • To supplement the ISO-GUM method for the evaluation of measurement uncertainty, a simulation program using the Monte Carlo method (MCM) was developed, and the MCM and GUM methods were compared. The results are as follows: (1) Even under a non-normal probability distribution of the measurand, MCM provides an accurate coverage interval; (2) Even if a probability distribution that emerged from combining a few non-normal distributions looks as normal, there are cases in which the actual distribution is not normal and the non-normality can be determined by the probability distribution of the combined variance; and (3) If type-A standard uncertainties are involved in the evaluation of measurement uncertainty, GUM generally offers an under-valued coverage interval. However, this problem can be solved by the Bayesian evaluation of type-A standard uncertainty. In this case, the effective degree of freedom for the combined variance is not required in the evaluation of expanded uncertainty, and the appropriate coverage factor for 95% level of confidence was determined to be 1.96.

Statistical Calibration and Validation of Mathematical Model to Predict Motion of Paper Helicopter (종이 헬리콥터 낙하해석모델의 통계적 교정 및 검증)

  • Kim, Gil Young;Yoo, Sung Bum;Kim, Dong Young;Kim, Dong Seong;Choi, Joo Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.8
    • /
    • pp.751-758
    • /
    • 2015
  • Mathematical models are actively used to reduce the experimental expenses required to understand physical phenomena. However, they are different from real phenomena because of assumptions or uncertain parameters. In this study, we present a calibration and validation method using a paper helicopter and statistical methods to quantify the uncertainty. The data from the experiment using three nominally identical paper helicopters consist of different groups, and are used to calibrate the drag coefficient, which is an unknown input parameter in both analytical models. We predict the predicted fall time data using probability distributions. We validate the analysis models by comparing the predicted distribution and the experimental data distribution. Moreover, we quantify the uncertainty using the Markov Chain Monte Carlo method. In addition, we compare the manufacturing error and experimental error obtained from the fall-time data using Analysis of Variance. As a result, all of the paper helicopters are treated as one identical model.

Runoff Analysis of Modified TOPMODEL with Subsurface Storm Flow Generation Mechanism (지표하 흐름을 고려한 개선된 TOPMODEL의 유출분석연구)

  • Lee, Hak-Su;Han, Ji-Yeong;Kim, Gyeong-Hyeon;Kim, Sang-Hyeon
    • Journal of Korea Water Resources Association
    • /
    • v.34 no.4
    • /
    • pp.403-411
    • /
    • 2001
  • This paper investigates the applicability of a modified version of TOPMODEL considering shallow subsurface storm flow in a forested mountaneous catchment. The macroporous soil structure provides a hydrological pathway for rapid runoff generation. A modified version of TOPMODEL introduces the two-storage system to analyze the hydrograph recession including rapid subsurface storm flow component. The two-month continuous hydrologic simulations of sulmachun watershed suggest that a modified version of TOPMODEL represents comprehensive and realistic flow generation mechanism comparing to those of an original version of TOPMODEL. The results of parameter calibration with Monte-Carlo method indicate a modified version of TOPMODEL produces a set of physically meaningful parameters.

  • PDF

The Comparative Analysis of External Dose Reconstruction in EPID and Internal Dose Measurement Using Monte Carlo Simulation (몬테 카를로 전산모사를 통한 EPID의 외부적 선량 재구성과 내부 선량 계측과의 비교 및 분석)

  • Jung, Joo-Young;Yoon, Do-Kun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.253-258
    • /
    • 2013
  • The purpose of this study is to evaluate and analyze the relationship between the external radiation dose reconstruction which is transmitted from the patient who receives radiation treatment through electronic portal imaging device (EPID) and the internal dose derived from the Monte Carlo simulation. As a comparative analysis of the two cases, it is performed to provide a basic indicator for similar studies. The geometric information of the experiment and that of the radiation source were entered into Monte Carlo n-particle (MCNPX) which is the computer simulation tool and to derive the EPID images, a tally card in MCNPX was used for visualizing and the imaging of the dose information. We set to source to surface distance (SSD) 100 cm for internal measurement and EPID. And the water phantom was set to be 100 cm of the source to surface distance (SSD) for the internal measurement and EPID was set to 90 cm of SSD which is 10 cm below. The internal dose was collected from the water phantom by using mesh tally function in MCNPX, accumulated dose data was acquired by four-portal beam exposures. At the same time, after getting the dose which had been passed through water phantom, dose reconstruction was performed using back-projection method. In order to analyze about two cases, we compared the penetrated dose by calibration of itself with the absorbed one. We also evaluated the reconstructed dose using EPID and partially accumulated (overlapped) dose in water phantom by four-portal beam exposures. The sum dose data of two cases were calculated as each 3.4580 MeV/g (absorbed dose in water) and 3.4354 MeV/g (EPID reconstruction). The result of sum dose match from two cases shows good agreement with 0.6536% dose error.