• Title/Summary/Keyword: Monte Carlo (MC) simulation

Search Result 138, Processing Time 0.023 seconds

Nystatin Drug as an Effective Corrosion Inhibitor for Mild Steel in Acidic Media- An Experimental and Theoretical Study

  • Mehmeti, Valbone
    • Corrosion Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.21-31
    • /
    • 2022
  • Potentiodynamic polarization, EIS measurements, quantum chemical calculations, and molecular dynamic simulations were used to investigate the corrosion behavior of mild steel in 0.5 M aqueous hydrochloric acid medium in the presence or absence of nystatin drug. Potentiodynamic tests suggested that this molecule could act as a mixed inhibitor due to its adsorption on the mild steel surface. The objective of this study was to exploit theoretical calculations to gain a better understanding mechanism of inhibition. Calculating the adsorption behavior of the investigated molecule on Fe (1 1 0) surface was accomplished using Monte Carlo simulation. Molecules were also investigated using Density Functional Theory (DFT), specifically PBE functional, in order to identify the link between molecular structure and corrosion inhibition behavior of the compound under investigation. Adsorption energies between nystatin and iron were estimated more accurately by utilizing Molecular Mechanics calculation with Periodic Boundary Conditions (PBC). Estimated theoretical parameters significantly assisted our understanding of the corrosion inhibition mechanism exhibited by this molecule. They were found to be in accord with experimental results.

Three-dimensional Modeling of Transient Enhanced Diffusion (과도 증속 확산(TED)의 3차원 모델링)

  • 이제희;원태영
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.6
    • /
    • pp.37-45
    • /
    • 1998
  • In this paper, we report the first three-dimensional simulation result of the transient enhanced diffusion(TED) of dopants in the ion-implanted silicon by employing our 3D semiconductor process simulator, INPROS system. In order to simulate three-dimensional TED redistribution of dopants in silicon, the dopant distributions after the ion implantation was calculated by Monte Carlo(MC) method, followed by finite element(FE) numerical solver for thermal annealing. Excellent agreement between the simulated 3D profile and the SIMS data has been obtained for ion-implanted arsenic and phosphorus after annealing the boron marker layer at 75$0^{\circ}C$ for 2 hours. Our three-dimensional TED simulation could successfully explain the reverse short channel effect(RSCE) by taking the 3D point defect distribution into account. A coupled TED simulation and device simulation allows reverse short channel effect on threshold to be accurately predicted.

  • PDF

Option Pricing and Sensitivity Evaluation Methodology: Improvement of Speed and Accuracy (옵션 가치 및 민감도 평가 방법: 속도와 정확도 개선에 대한 고찰)

  • Choi, Young-Soo;Oh, Se-Jin;Lee, Won-Chang
    • Communications for Statistical Applications and Methods
    • /
    • v.15 no.4
    • /
    • pp.563-585
    • /
    • 2008
  • This paper presents how to improve the efficiency and accuracy in the pricing and sensitivity evaluation for derivatives, since the need for the evaluation of complicated derivatives is increased. The Monte Carlo(MC) simulation using the quasi random number instead of pseudo random number can improve the elapsed time and accuracy for the valuation of European-type derivatives. However, the quasi MC simulation method has its limit for applying it in the multi-dimensional case such as American-type and path-dependent options due to the increased correlation between dimensions as the dimension of random numbers is increased. In order to complement this problem, we develop a modified method in which correlation values are controlled to be below a pre-specified value. Thus, this method is applicable for the pricing of either derivatives ill which underlying assets or risk factors are several or derivatives having path-dependent or early redemption property. Furthermore, we illustrate that it is important to take an appropriate grid interval for the use of finite difference method(FDM) by applying the FDM to one example of non-symmetrical butterfly spreads.

Impacts of Burnup-Dependent Swelling of Metallic Fuel on the Performance of a Compact Breed-and-Burn Fast Reactor

  • Hartanto, Donny;Heo, Woong;Kim, Chihyung;Kim, Yonghee
    • Nuclear Engineering and Technology
    • /
    • v.48 no.2
    • /
    • pp.330-338
    • /
    • 2016
  • The U-Zr or U-TRU-Zr cylindrical metallic fuel slug used in fast reactors is known to swell significantly and to grow during irradiation. In neutronics simulations of metallic-fueled fast reactors, it is assumed that the slug has swollen and contacted cladding, and the bonding sodium has been removed from the fuel region. In this research, a realistic burnup-dependent fuel-swelling simulation was performed using Monte Carlo code McCARD for a single-batch compact sodium-cooled breed-and-burn reactor by considering the fuel-swelling behavior reported from the irradiation test results in EBR-II. The impacts of the realistic burnup-dependent fuel swelling are identified in terms of the reactor neutronics performance, such as core lifetime, conversion ratio, axial power distribution, and local burnup distributions. It was found that axial fuel growth significantly deteriorated the neutron economy of a breed-and-burn reactor and consequently impaired its neutronics performance. The bonding sodium also impaired neutron economy, because it stayed longer in the blanket region until the fuel slug reached 2% burnup.

Design of Multipurpose Phantom for External Audit on Radiotherapy

  • Lim, Sangwook
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.122-129
    • /
    • 2021
  • Purpose: This study aimed to design a multipurpose dose verification phantom for external audits to secure safe and optimal radiation therapy. Methods: In this study, we used International Atomic Energy Agency (IAEA) LiF powder thermoluminescence dosimeter (TLD), which is generally used in the therapeutic radiation dose assurance project. The newly designed multipurpose phantom (MPP) consists of a container filled with water, a TLD holder, and two water-pressing covers. The size of the phantom was designed to be sufficient (30×30×30 cm3). The water container was filled with water and pressed with the cover for normal incidence to be fixed. The surface of the MPP was devised to maintain the same distance from the source at all times, even in the case of oblique incidence regardless of the water level. The MPP was irradiated with 6, 10, and 15 MV photon beams from Varian Linear Accelerator and measured by a 1.25 cm3 ionization chamber to get the correction factors. Monte Carlo (MC) simulation was also used to compare the measurements. Results: The result obtained by MC had a relatively high uncertainty of 1% at the dosimetry point, but it showed a correction factor value of 1.3% at the 5 cm point. The energy dependence was large at 6 MV and small at 15 MV. Various dosimetric parameters for external audits can be performed within an hour. Conclusions: The results allow an objective comparison of the quality assurance (QA) of individual hospitals. Therefore, this can be employed for external audits or QA systems in radiation therapy institutions.

DOProC-based reliability analysis of structures

  • Janas, Petr;Krejsa, Martin;Sejnoha, Jiri;Krejsa, Vlastimil
    • Structural Engineering and Mechanics
    • /
    • v.64 no.4
    • /
    • pp.413-426
    • /
    • 2017
  • Probabilistic methods are used in engineering where a computational model contains random variables. The proposed method under development: Direct Optimized Probabilistic Calculation (DOProC) is highly efficient in terms of computation time and solution accuracy and is mostly faster than in case of other standard probabilistic methods. The novelty of the DOProC lies in an optimized numerical integration that easily handles both correlated and statistically independent random variables and does not require any simulation or approximation technique. DOProC is demonstrated by a collection of deliberately selected simple examples (i) to illustrate the efficiency of individual optimization levels and (ii) to verify it against other highly regarded probabilistic methods (e.g., Monte Carlo). Efficiency and other benefits of the proposed method are grounded on a comparative case study carried out using both the DOProC and MC techniques. The algorithm has been implemented in mentioned software applications, and has been used effectively several times in solving probabilistic tasks and in probabilistic reliability assessment of structures. The article summarizes the principles of this method and demonstrates its basic possibilities on simple examples. The paper presents unpublished details of probabilistic computations based on this method, including a reliability assessment, which provides the user with the probability of failure affected by statistically dependent input random variables. The study also mentions the potential of the optimization procedures under development, including an analysis of their effectiveness on the example of the reliability assessment of a slender column.

ACA: Automatic search strategy for radioactive source

  • Jianwen Huo;Xulin Hu;Junling Wang;Li Hu
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.3030-3038
    • /
    • 2023
  • Nowadays, mobile robots have been used to search for uncontrolled radioactive source in indoor environments to avoid radiation exposure for technicians. However, in the indoor environments, especially in the presence of obstacles, how to make the robots with limited sensing capabilities automatically search for the radioactive source remains a major challenge. Also, the source search efficiency of robots needs to be further improved to meet practical scenarios such as limited exploration time. This paper proposes an automatic source search strategy, abbreviated as ACA: the location of source is estimated by a convolutional neural network (CNN), and the path is planned by the A-star algorithm. First, the search area is represented as an occupancy grid map. Then, the radiation dose distribution of the radioactive source in the occupancy grid map is obtained by Monte Carlo (MC) method simulation, and multiple sets of radiation data are collected through the eight neighborhood self-avoiding random walk (ENSAW) algorithm as the radiation data set. Further, the radiation data set is fed into the designed CNN architecture to train the network model in advance. When the searcher enters the search area where the radioactive source exists, the location of source is estimated by the network model and the search path is planned by the A-star algorithm, and this process is iterated continuously until the searcher reaches the location of radioactive source. The experimental results show that the average number of radiometric measurements and the average number of moving steps of the ACA algorithm are only 2.1% and 33.2% of those of the gradient search (GS) algorithm in the indoor environment without obstacles. In the indoor environment shielded by concrete walls, the GS algorithm fails to search for the source, while the ACA algorithm successfully searches for the source with fewer moving steps and sparse radiometric data.

Sputtering of Solid Surfaces at Ion Bombardment

  • Kang, Hee-Jae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1998.02a
    • /
    • pp.20-20
    • /
    • 1998
  • I Ion beam technology has recently attracted much interest because it has exciting t technological p아:ential for surface analysis, ion beam mixing, surface cleaning and etching i in thin film growth and semiconductor fabrication processes, etc. Es야~cially, ion beam s sputtering has been widely used for sputter depth profiling with x-photoelectron S spectroscopy (XPS) , Auger electron s$\pi$~troscopy(AES), and secondary-ion mass S야i따oscopy(SIMS). However, The problem of surface compositional ch없1ge due to ion b bombardment remains to be understo여 없ld solved. So far sputtering processes have been s studied by s따face an외ysis tools such as XPS, AES, and SIMS which use the sputtering p process again. It would be improbable to measure the modified surface composition profiles a accurately due to ion beam bombardment with surface analysis techniques based on sputter d depth profiling. However, recently Medium energy ion scattering spectroscopy(MEIS) has b been applied to study the sputtering of solid surface at ion bombardment and has been p proved that it has been extremely valuable in probing the surface composition 뻐d s structure nondestructively and quantita디vely with less than 1.0 nm depth resolution. To u understand the sputtering processes of solid surface at ion bombardment, The Molecular D Dynamics(MD) and Monte Carlo(MC) simulation has been used and give an intimate i insight into the sputtering processes of solid surfaces. In this presentation, the sputtering processes of alloys and compound samples at ion b bombardment will be reviewed and the MEIS results for the Ar+ sputter induced altered l layer of the TazOs thin film 뻐dd없nage profiling of Ar+ ion sputt얹"ed Si(100) surface will b be discussed with the results of MD and MC simulation.tion.

  • PDF

Characteristics of Polarization and Birefringence for Submicron a-Ge Thin Film on Quartz Substrate Formed by Focused-Ion-Beam (석영 기판 위에 집속 이온빔 기술에 의해 형성된 비정질 게르마늄 박막 미세 패턴의 편광 및 복굴절 특성)

  • Shin, Kyung;Ki, Jin-Woo;Park, Chung-Il;Lee, Hyun-Yong;Chung, Hong-Bay
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.617-620
    • /
    • 1999
  • In this study, the polarization e(fecal and the birefringence effect of amorphous germanium (a-Ge) thin films were investigated by using linearly polarized He-Ne laser beam. The a-7e thin films were deposited on the quarts substrate by plasma enhanced chemical vapor deposition (PECVD) and thermal vacuum evaporation In order to obtain the optimum grating arrays, inorganci resists such as Si$_3$N$_4$ and a-Se$_{75}$ Ge$_{25}$ , were prepared with the optimized thickness by Monte Carlo (MC) simulation. As the results of MC simulation, the thickness ofa-Se$_{75}$ Ge$_{25}$ resist was determined with Z$_{min}$ of 360$\AA$ . The resists were exposed to Ga$^{+}$-FIB with accelerating energies of 50 keV, developed by wet etching, and a-Ge thin film was etched by reactive ion-etching (RIE). Finally, we were obtained grating arrays which grating width and linewidth are 0.8${\mu}{\textrm}{m}$, respectively and we studied the polarization and birefringence effect in transmission grating array made of high refractive amorphous material, and the applicability as waveplates and polarizers in optical device.e.e.

  • PDF

Interstitial Photodynamic Therapy (PDT) Set-up for Treating Solid Tumor Using Laser Diode (레이저 다이오드를 이용한 고형암 치료를 위한 간질성 광역학 치료법 개발)

  • Kim Jong-Ki;Kim Ki-Hong
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.104-109
    • /
    • 2005
  • Photodynamic therapy (PDT) is one of the expectable current cure operation methods. Tumor tissue is treated by abundant oxygen in a body and generated singlet or free radical from exterior laser diode and photosensitizer. Current problem of PDT is the low penetration power of the light beam in a deep seated large tumor and solid tumor thus results in low treatment outcome. In the study, we tried to develop interstitial photodynamics therapy treatment to solve this problem. As the accurate determination of light dosimetry in biological tissue is one of the most important factors affecting the effectiveness of PDT, parameters used in this study are the optical property of biological tissue. Since biological tissues have large scattering coefficient to visible light the penetration depth of a biological tissue in visible light region is only $15\~20$ mm. We showed that it is possible to measure fluence rate and penetration depth within the biological tissues by Monte Carlo simulation very well. Based on the MC simulation study, the effectiveness of interstitial photodynamic therapy on tumor control in solid tumor was proved through in vivo animal experiment.

  • PDF