• Title/Summary/Keyword: Monitoring-Evaluation

Search Result 2,531, Processing Time 0.032 seconds

Evaluation of Manufacturing and Biological Properties of Y Zone Care Hydrogel Solution (Y존 케어 하이드로젤솔루션의 제조 및 생물학적 특성 평가)

  • Eun-Ji Kim;In-Kyoung Kim
    • Journal of Advanced Technology Convergence
    • /
    • v.3 no.2
    • /
    • pp.25-31
    • /
    • 2024
  • In recent industrialization and development due to information and communication technology, modern women in modern society are exposed to physical and mental health due to numerous stresses. Popular inflammations are attributable to a decrease in lactic acid bacteria, frequent antibiotic use, and a decrease in immunity. It is necessary to develop products that are helpful and reflected. The inner care gel currently introduced on the market can increase beneficial bacteria and maintain a healthy y-zone. The inner gel contains a hydrogel component. 90% is made up of water, and other components act as support for supporting water and are formed through crosslinking between polymer chains. Hydroxyethyl cellulose (HEC) is a hydroxyethyl ethylenetel of cellulose. The purpose of use is to act as a binder, an emulsion stabilizer, a viscosity enhancer (water-soluble), and a film forming agent. CA (crosslinker) is a crosslinking agent and serves to bind. Hydrogel in the beauty field acts as a film forming agent that gently wraps around the skin by forming a thin film and serves as an emulsion stabilizer that helps to prevent separation of other raw materials. It also acts as a thickener by increasing viscosity in cosmetics. In addition, it is used for glucose monitoring, nursing care, cell transplantation, and wound treatment in the bio field. Currently, it is understood that no products using functional hydrogel have been released, so in this study, a Y zone care hydrogel solution was manufactured to find out the antibacterial properties of the functional hydrogel, and a new solution was developed. As a result, it was confirmed that the appropriate Ph was applied to the Y zone, and after culturing Candida albicans in PDB medium, all three products of the Y zone care hydrogel solution showed an antibacterial effect of 0.5-1.0mm

Developing the Indicator System for Diagnosing the National Status Quo of Science Culture (국가 수준의 과학문화 실태 진단을 위한 지표 체제 개발)

  • Song, Jin-Woong;Choi, Jae-Hyeok;Kim, Hee-Kyong;Chung, Min-Kyung;Lim, Jin-Young;Cho, Sook-Kyoung
    • Journal of The Korean Association For Science Education
    • /
    • v.28 no.4
    • /
    • pp.316-330
    • /
    • 2008
  • During the past two decades or so, science (or scientific or scientific & technological) culture has become one of the main themes not only of policy makers but also of science educators. Although, the idea of science culture has been taken as a desirable goal, there is little agreement about what it means and how to measure it. Particularly in Korea, there has been a rapid growth of science culture projects and programs, either by governmental or non-governmental, but with little systemic monitoring and evaluation for its practice. The purpose of this study is, thus, to explore a model of measuring science culture and develop a comprehensive indicator system for it. We reviewed many literatures on definitions of science culture and the surveys for related terms, particularly, of recent national and international surveys (e.g. US Science and Engineering Indicators, Eurobarometer, Japanese Science and Technology Indicators). Based on this review, a model for science culture is proposed and then used to define the Science Culture Indicators (SCI). This model encompasses two dimensions(i.e. individual and social), which are further divided into two aspects (i.e. potential and practice). Each dimension is expected to represent citizen literacy of and national infrastructure of science culture respectively. Each category in this $2{\times}2$ matrix is further divided into several sub-categories. The discussion concerning how the model and the indicators can be used to check the states of science culture at social as well as individual levels will be given with some concrete examples, such as indicators particularly related to science education.

Determination of Fomesafen Residue in Agricultural Commodities Using HPLC-UVD/MS (HPLC-UVD/MS를 이용한 농산물 중 fomesafen의 분석)

  • Lee, Su-Jin;Hwang, Young-Sun;Kim, Young-Hak;Nam, Mi-Young;Hong, Seung-Beom;Yun, Won-Kap;Kwon, Chan-Hyeok;Do, Jung-A;Im, Moo-Hyeog;Lee, Young-Deuk;Choung, Myoung-Gun
    • The Korean Journal of Pesticide Science
    • /
    • v.14 no.2
    • /
    • pp.95-103
    • /
    • 2010
  • Fomesafen is a selective herbicide, and used to control annual and perennial broad-leaf grass on soybean and fruit fields in USA and China, but not introduced in Korea yet. So, MRL (Maximum Residue Level), and analytical method of fomesafen were not establishment in Korea. Therefore, this experiment was conducted to establish a determination method for fomesafen residue in crops using HPLC-UVD/MS. Fomesafen residue was extracted with acetone from representative samples of five raw products which comprised hulled rice, soybean, apple, green pepper, and Chinese cabbage. The extract was diluted with saline water, and dichloromethane partition was followed to recover fomesafen from the aqueous phase. Florisil column chromatography was additionally employed for final clean up of the extract. The fomesafen was quantitated by HPLC with UVD, using a Shiseido CAPCELL-PAK UG C18 column. The crops were fortified with fomesafen at 3 levels per crop. Mean recovery ratio were ranged from 87.5% for a 0.4 ppm in hulled rice to 102.5% for a 0.4 ppm in apple. The coefficients of variation were ranged from 0.6% for a 2.0 ppm in hulled rice to 7.7% for a 0.04 ppm in green pepper. Quantitative limit of fomesafen was 0.04 mg/kg in representative 5 crop samples. A LC/MS with selected-ion monitoring was also provided to confirm the suspected residue. Therefore, this analytical method was reproducible and sensitive enough to determine the residue of fomesafen in agricultural commodities.

Accuracy evaluation of microwave water surface current meter for measurement angles in middle flow condition (전자파표면유속계의 측정 각도에 따른 평수기 유속 측정 정확도 분석)

  • Son, Geunsoo;Kim, Dongsu;Kim, Kyungdong;Kim, Jongmin
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.1
    • /
    • pp.15-27
    • /
    • 2020
  • Streamflow discharge as a fundamental riverine quantity plays a crucial role in water resources management, thereby requiring accurate in-situ measurement. Recent advances in instrumentations for the streamflow discharge measurement has complemented or substituted classical devices and methods. Among various potential methods, surface current meter using microwave has increasingly begun to be applied not only for flood but also normal flow discharge measurement, remotely and safely enabling practitioners to measure flow velocity postulating indirect contact. With minimized field preparedness, this method facilitated and eased flood discharge measurement in the difficult in-situ conditions such as extreme flood in active ways emitting 24.125 GHz microwave without relying on natural lights. In South Korea, a rectangular shaped instrument named with Microwave Water Surface Current Meter (MWSCM) has been developed and commercially released around 2010, in which domestic agencies charging on streamflow observation shed lights on this approach regarding it as a potential substitute. Considering this brand-new device highlighted for efficient flow measurement, however, there has been few noticeable efforts in systematic and comprehensive evaluation of its performance in various measurement and riverine conditions that lead to lack in imminent and widely spreading usages in practices. This study attempted to evaluate the MWSCM in terms of instrumen's monitoring configuration particularly regarding tilt and yaw angle. In the middle of pointing the measurement spot in a given cross-section, the observation campaign inevitably poses accuracy issues related with different tilt and yaw angles of the instrument, which can be a conventionally major source of errors for this type of instrument. Focusing on the perspective of instrument configuration, the instrument was tested in a controlled outdoor river channel located in KICT River Experiment Center with a fixed flow condition of around 1 m/s flow speed with steady flow supply, 6 m of channel width, and less than 1 m of shallow flow depth, where the detailed velocity measurements with SonTek micro-ADV was used for validation. As results, less than 15 degree in tilting angle generated much higher deviation, and higher yawing angle proportionally increased coefficient of variance. Yaw angles affected accuracy in terms of measurement area.

A Study on Qulity Perceptions and Satisfaction for Medical Service Marketing (의료서비스 마케팅을 위한 품질지각과 만족에 관한 연구)

  • Yoo, Dong-Keun
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.2 no.1
    • /
    • pp.97-114
    • /
    • 1996
  • INSTRODUCTION Service quality is, unlike goods quality, an abstract and elusive constuct. Service quality and its requirements are not easily understood by consumers, and also present some critical research problems. However, quality is very important to marketers and consumers in that it has many strategic benefits in contributing to profitability of marketing activities and consumers' problem-solving activities. Moreover, despite the phenomenal growth of medical service sector, few researchers have attempted to define and model medical service quality. Especially, little research has focused on the evaluation of medical service quality and patient satisfaction from the perspectives of both the provider and the patient. As competition intensifies and patients are demanding higher quality of medical service, medical service quality and patient satisfaction has emerged as a critical research topic. The major purpose of this article is to explore the concept of medical service quality and its evaluation from both nurse and patient perspectives. This article attempts to achieve its purpose by (1)classfying critical service attibutes into threecategories(satisfiers, hygiene factors, and performance factors). (2)measuring the relative importance of need criteria, (3)evaluating SERVPERF model and SERVQUAL model in medical service sector, and (4)identifying the relationship between perceived quality and overall patient satisfaction. METHOD Data were gathered from a sample of 217 patients and 179 nurses in Seoul-area general hospitals. From the review of previous literature, 50 survey items representing various facets of the medical service quality were developed to form a questionnaire. A five-point scale ranging from "Strongly Agree"(5) to "Strongly Disagree"(1) accompanied each statement(expectation statements, perception statements, and importance statements). To measure overall satisfaction, a seven-point scale was used, ranging from "Very Satisfied"(7) to "Very Dissatisfied"(1) with no verbal labels for scale points 2 through 6 RESULTS In explaining the relationship between perceived performance and overall satisfaction, only 31 variables out of original 50 survey items were proven to be statistically significant. Hence, a penalty-reward analysis was performed on theses 31 critical attributes to find out 17 satisfiers, 8 hygiene factors, and 4 performance factors in patient perspective. The role(category) of each service quality attribute in relation to patient satisfaction was com pared across two groups, that is, patients and nurses. They were little overlapped, suggesting that two groups had different sets of 'perceived quality' attributes. Principal components factor analyses of the patients' and nurses' responses were performed to identify the underlying dimensions for the set of performance(experience) statements. 28 variables were analyzed by using a varimax rotation after deleting three obscure variables. The number of factors to be extracted was determined by evaluating the eigenvalue scores. Six factors wereextracted, accounting for 57.1% of the total variance. Reliability analysis was performed to refine the factors further. Using coefficient alpha, scores of .84 to .65 were obtained. Individual-item analysis indicated that all statements in each of the factors should remain. On 26 attributes of 31 critical service quality attributes, there were gaps between actual patient's importance of need criteria and nurse perceptions of them. Those critical attributes could be classified into four categories based on the relative importance of need criteria and perceived performance from the perspective of patient. This analysis is useful in developing strategic plans for performance improvement. (1) top priorities(high importance and low performance) (in this study)- more health-related information -accuracy in billing - quality of food - appointments at my convenience - information about tests and treatments - prompt service of business office -adequacy of accommodations(elevators, etc) (2) current strengths(high importance and high performance) (3)unnecessary strengths(low importance and high performance) (4) low priorities(low importance and low performance) While 26 service quality attributes of SERPERF model were significantly related to patient satisfation, only 13 attributes of SERVQUAL model were significantly related. This result suggested that only experience-based norms(SERVPERF model) were more appropriate than expectations to serve as a benchmark against which service experiences were compared(SERVQUAL model). However, it must be noted that the degree of association to overall satisfaction was not consistent. There were some gaps between nurse percetions and patient perception of medical service performance. From the patient's viewpoint, "personal likability", "technical skill/trust", and "cares about me" were most significant positioning factors that contributed patient satisfaction. DISCUSSION This study shows that there are inconsistencies between nurse perceptions and patient perceptions of medical service attributes. Also, for service quality improvement, it is most important for nurses to understand what satisfiers, hygiene factors, and performance factors are through two-way communications. Patient satisfaction should be measured, and problems identified should be resolved for survival in intense competitive market conditions. Hence, patient satisfaction monitoring is now becoming a standard marketing tool for healthcare providers and its role is expected to increase.

  • PDF

Monitoring of Natural Preservative Levels in Food Products (가공식품 중 천연유래 보존료 함량에 대한 조사)

  • Park, Eun-Ryong;Lee, Sun-Kyu;Hwang, Hye-Shin;Mun, Chun-Sun;Gwak, In-Shin;Kim, Ok-Hee;Lee, Kwang-Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.12
    • /
    • pp.1640-1646
    • /
    • 2008
  • In the current food sanitation regulation, food additives are under controlled by the Food Code. The naturally derived preservatives such as benzoic acid and propionic acid can be naturally carried over or produced as metabolites during manufacturing process such as fermentation. To monitor naturally formed benzoic acid and propionic acid levels, a total of 145 samples were classified into berries (prune, cranberry), functional foods (propolis liquid, ginseng product), vinegars (vinegar-based drink, vinegar beverage, vinegar), and salted and pickled products (olive, pickled cucumber, salted/pickled product) and analyzed by HPLC-PDA and GC-FID. From the results, benzoic acid and propionic acid were each detected and identified in 144 samples and 64 samples respectively. The amount of benzoic acid ranged from $4.1{\sim}478.4\;ppm$ in cranberry, from $49.7{\sim}491$ in propolis liquid, and from $2.5{\sim}10.2\;ppm$ in ginseng, and other tested samples contained very small quantity. Also, the amount of propionic acid ranged from $179.8{\sim}951.9\;ppm$ (av. 553.6 ppm) in vinegar (persimmon vinegar 100%), which was the highest level among fermented foods, from $13.7{\sim}247.0$ ppm in propolis liquid, from $2.0{\sim}180.7\;ppm$ in vinegar-based drink, and from $1.6{\sim}76.6\;ppm$ in olive. Vinegar beverage and pickled cucumber each showed 24 and 18 ppm of propionic acid; in contrast, propionic acid was not detected in prune, cranberry, ginseng, and picked/salted products.

The Study on the Confidence Building for Evaluation Methods of a Fracture System and Its Hydraulic Conductivity (단열체계 및 수리전도도의 해석신뢰도 향상을 위한 평가방법 연구)

  • Cho Sung-Il;Kim Chun-Soo;Bae Dae-Seok;Kim Kyung-Su;Song Moo-Young
    • The Journal of Engineering Geology
    • /
    • v.15 no.2 s.42
    • /
    • pp.213-227
    • /
    • 2005
  • This study aims to assess the problems with investigation method and to suggest the complementary solutions by comparing the predicted data from surface investigation with the outcome data from underground cavern. In the study area, one(NE-1) of 6 fracture zones predicted during the surface investigation was only confirmed in underground caverns. Therefore, it is necessary to improve the confidence level for prediction. In this study, the fracture classification criteria was quantitatively suggested on the basis of the BHTV images of NE-1 fracture zone. The major orientation of background fractures in rock mass was changed at the depth of the storage cavern, the length and intensity were decreased. These characteristics result in the deviation of predieted predicted fracture properties and generate the investigation bias depending on the bore hole directions and investigated scales. The evaluation of hydraulic connectivity in the surface investigation stage needs to be analyze by the groundwater pressures and hydrochemical properties from the monitoring bore hole(s) equipped with a double completion or multi-packer system during the test bore hole is pumping or injecting. The hydraulic conductivities in geometric mean measured in the underground caverns are 2-3 times lower than those from the surface and furthermore the horizontal hydraulic conductivity in geometric mean is six times lower than the vertical one. To improve confidence level of the hydraulic conductivity, the orientation of test hole should be considered during the analysis of the hydraulic conductivity and the methodology of hydro-testing and interpretation should be based on the characteristics of rock mass and investigation purposes.

Monitoring of Antimicrobial Resistant Bacteria from Animal Farm Environments in Korea (국내 축산 환경 중의 항생제 내성균 모니터링에 관한 연구)

  • Kwon, Young-Il;Kim, Tae-Woon;Kim, Hae-Yeong;Chang, Yun-Hee;Kwak, Hyo-Sun;Woo, Gun-Jo;Chung, Yun-Hee
    • Microbiology and Biotechnology Letters
    • /
    • v.35 no.1
    • /
    • pp.17-25
    • /
    • 2007
  • The kinds and quantity of antimicrobial agents used for cattle (animal industry) may be considerable, suggesting the possibility that pathogenic bacteria which cannot be extirpated by the existing antimicrobial agents could appear. Ten cattle, pig and chicken farms, respectively, were randomly selected from 5 provinces in Korea and the samples were collected from excrement, manure, underground water, farmers' hands and the neishboring environment. h total of 299 samples were examined and 197 of Escherichia coli, 13 of Campylobacter jejun/coli, 223 of Enterococcus faecium/faecalis and 42 of Staphylococcus aureus isolates were collected. All isolates were screened for antimicrobial resistance: 69.4% of E. coli (137/197 strains), 78.6% of S. aureus (33/42 strains), and 82.1% of E. faecium/faecalis (183/223 strains) were resistant to one antimicrobial agent and all of C. jejuni/coli Isolates showed the resistance to one antimicrobial agent. Meanwhile, the multiple resistance ratio for more than 4 lines of antimicrobial agent was 19.2% of E. coli (38/197 strains), 11.9% of S. aureus (5/42 strains), 15.4% of C. jejuni/coli (2/13 strains) and 6.2% of E. faecium/faecalis (14/223 strains). The antimicrobial resistance ratio of bacteria isolated from the cattle farm showed lower than that of bacteria isolated from the pig or chicken farm, which might be related to the quantify of antimicrobial agents consumed. And one strain of vancomycin resistant E..faecium (VREF) were isolated from the excrement of chicken and stream, respectively. Generally, the ratio of VREF collected in animal farm environments is lower than that of VREF collected in medical environment.

Evaluation of Average CT to Reduce the Artifact in PET/CT (PET/CT 검사에서 호흡에 따른 인공산물을 줄이기 위한 Average CT의 유용성)

  • Kim, Jung-Sun;Nam, Ki-Pyo;Park, Seung-Yong;Ryu, Jae-Kwang;Cha, Min-Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.3-7
    • /
    • 2010
  • Purpose: The usefulness of Positron Emission Tomography (PET) images in diagnosis, staging, recurrent and treatment response evaluation has already been known. However, tumors which are small size, located in lower lobe of lung or upper lobe of liver are shown misalignment, distortion and different Standard Uptake Value (SUV) by respiration in PET images. Therefore, if radiotherapy based on normal respiration, it may cause low treatment response or more side effects because targets which had to treat, out of treat range or over dose to normal tissue. The purpose of this study is to evaluate attenuation-correction with Average CT (ACT) for more accuracy SUV measurement and minimize artifact by respiration. Materials and Methods: 13 patients, who had tumors which are around the diaphragm, underwent ACT scan after Helical CT (HCT) scan with PET/CT (Discovery DSTE 8; GE Healthcare). We quantified the differences between attenuation corrected image with HCT and attenuation corrected image with ACT in artifact size and maximum SUV ($SUV_{max}$). Artifacts were evaluated by measurement of the curved photogenic area in the lower thorax of the PET images for all patients. $SUV_{max}$ was measured separately at the primary tumors. Analysis program was Advantage Workstation v4.3 (GE Healthcare). Patients were injected with 7.4 MBq (0.2 $mC_i$) per kg of $^{18}F$-FDG and scanned 1 hour after injection. The PET acquisition was 3 minute per bed. Results: Significantly lower artifact were observed in PET/ACT images than in PET/HCT images (below-thoracic artifacts caused by under corrected $1.5{\pm}3.5$ cm vs. $13.4{\pm}4.2$ cm). Significantly higher $SUV_{max}$ were noted in PET/ACT images than in PET/HCT images in the primary tumor. Compared with PET/HCT images, $SUV_{max}$ in PET/ACT images were higher by $5.3{\pm}3.9%$ (mean value) tumor. The highest difference was observed in Lower lobe of lung (7.7 to 8.7; 13%). Conclusion: Due to its significantly reduced artifacts in lower thoracic, attenuation corrected image with ACT images provided more reliable $SUV_{max}$ and may be helpful in monitoring treatment response. Moreover, ACT can separate upper lobe of liver and lower lobe of lung, it may be helpful in interpretation. ACT will be clinically useful, considering increased dose caused by ACT scan and adapt.

  • PDF

Development of Artificial Pulmonary Nodule for Evaluation of Motion on Diagnostic Imaging and Radiotherapy (움직임 기반 진단 및 치료 평가를 위한 인공폐결절 개발)

  • Woo, Sang-Keun;Park, Nohwon;Park, Seungwoo;Yu, Jung Woo;Han, Suchul;Lee, Seungjun;Kim, Kyeong Min;Kang, Joo Hyun;Ji, Young Hoon;Eom, Kidong
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.76-83
    • /
    • 2013
  • Previous studies about effect of respiratory motion on diagnostic imaging and radiation therapy have been performed by monitoring external motions but these can not reflect internal organ motion well. The aim of this study was to develope the artificial pulmonary nodule able to perform non-invasive implantation to dogs in the thorax and to evaluate applicability of the model to respiratory motion studies on PET image acquisition and radiation delivery by phantom studies. Artificial pulmonary nodule was developed on the basis of 8 Fr disposable gastric feeding tube. Four anesthetized dogs underwent implantation of the models via trachea and implanted locations of the models were confirmed by fluoroscopic images. Artificial pulmonary nodule models for PET injected $^{18}F$-FDG and mounted on the respiratory motion phantom. PET images of those acquired under static, 10-rpm- and 15-rpm-longitudinal round motion status. Artificial pulmonary nodule models for radiation delivery inserted glass dosemeter and mounted on the respiratory motion phantom. Radiation delivery was performed at 1 Gy under static, 10-rpm- and 15-rpm-longitudinal round motion status. Fluoroscpic images showed that all models implanted in the proximal caudal bronchiole and location of models changed as respiratory cycle. Artificial pulmonary nodule model showed motion artifact as respiratory motion on PET images. SNR of respiratory gated images was 7.21. which was decreased when compared with that of reference images 10.15. However, counts of respiratory images on profiles showed similar pattern with those of reference images when compared with those of static images, and it is assured that reconstruction of images using by respiratory gating improved image quality. Delivery dose to glass dosemeter inserted in the models were same under static and 10-rpm-longitudinal motion status with 0.91 Gy, but dose delivered under 15-rpm-longitudinal motion status was decreased with 0.90 Gy. Mild decrease of delivered radiation dose confirmed by electrometer. The model implanted in the proximal caudal bronchiole with high feasibility and reflected pulmonary internal motion on fluoroscopic images. Motion artifact could show on PET images and respiratory motion resulted in mild blurring during radiation delivery. So, the artificial pulmonary nodule model will be useful tools for study about evaluation of motion on diagnostic imaging and radiation therapy using laboratory animals.