• Title/Summary/Keyword: Monitoring and evaluation

Search Result 2,535, Processing Time 0.038 seconds

Evaluation for applicability of river depth measurement method depending on vegetation effect using drone-based spatial-temporal hyperspectral image (드론기반 시공간 초분광영상을 활용한 식생유무에 따른 하천 수심산정 기법 적용성 검토)

  • Gwon, Yeonghwa;Kim, Dongsu;You, Hojun
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.4
    • /
    • pp.235-243
    • /
    • 2023
  • Due to the revision of the River Act and the enactment of the Act on the Investigation, Planning, and Management of Water Resources, a regular bed change survey has become mandatory and a system is being prepared such that local governments can manage water resources in a planned manner. Since the topography of a bed cannot be measured directly, it is indirectly measured via contact-type depth measurements such as level survey or using an echo sounder, which features a low spatial resolution and does not allow continuous surveying owing to constraints in data acquisition. Therefore, a depth measurement method using remote sensing-LiDAR or hyperspectral imaging-has recently been developed, which allows a wider area survey than the contact-type method as it acquires hyperspectral images from a lightweight hyperspectral sensor mounted on a frequently operating drone and by applying the optimal bandwidth ratio search algorithm to estimate the depth. In the existing hyperspectral remote sensing technique, specific physical quantities are analyzed after matching the hyperspectral image acquired by the drone's path to the image of a surface unit. Previous studies focus primarily on the application of this technology to measure the bathymetry of sandy rivers, whereas bed materials are rarely evaluated. In this study, the existing hyperspectral image-based water depth estimation technique is applied to rivers with vegetation, whereas spatio-temporal hyperspectral imaging and cross-sectional hyperspectral imaging are performed for two cases in the same area before and after vegetation is removed. The result shows that the water depth estimation in the absence of vegetation is more accurate, and in the presence of vegetation, the water depth is estimated by recognizing the height of vegetation as the bottom. In addition, highly accurate water depth estimation is achieved not only in conventional cross-sectional hyperspectral imaging, but also in spatio-temporal hyperspectral imaging. As such, the possibility of monitoring bed fluctuations (water depth fluctuation) using spatio-temporal hyperspectral imaging is confirmed.

Preliminary Study on the MR Temperature Mapping using Center Array-Sequencing Phase Unwrapping Algorithm (Center Array-Sequencing 위상펼침 기법의 MR 온도영상 적용에 관한 기초연구)

  • Tan, Kee Chin;Kim, Tae-Hyung;Chun, Song-I;Han, Yong-Hee;Choi, Ki-Seung;Lee, Kwang-Sig;Jun, Jae-Ryang;Eun, Choong-Ki;Mun, Chi-Woong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.131-141
    • /
    • 2008
  • Purpose : To investigate the feasibility and accuracy of Proton Resonance Frequency (PRF) shift based magnetic resonance (MR) temperature mapping utilizing the self-developed center array-sequencing phase unwrapping (PU) method for non-invasive temperature monitoring. Materials and Methods : The computer simulation was done on the PU algorithm for performance evaluation before further application to MR thermometry. The MR experiments were conducted in two approaches namely PU experiment, and temperature mapping experiment based on the PU technique with all the image postprocessing implemented in MATLAB. A 1.5T MR scanner employing a knee coil with $T2^*$ GRE (Gradient Recalled Echo) pulse sequence were used throughout the experiments. Various subjects such as water phantom, orange, and agarose gel phantom were used for the assessment of the self-developed PU algorithm. The MR temperature mapping experiment was initially attempted on the agarose gel phantom only with the application of a custom-made thermoregulating water pump as the heating source. Heat was generated to the phantom via hot water circulation whilst temperature variation was observed with T-type thermocouple. The PU program was implemented on the reconstructed wrapped phase images prior to map the temperature distribution of subjects. As the temperature change is directly proportional to the phase difference map, the absolute temperature could be estimated from the summation of the computed temperature difference with the measured ambient temperature of subjects. Results : The PU technique successfully recovered and removed the phase wrapping artifacts on MR phase images with various subjects by producing a smooth and continuous phase map thus producing a more reliable temperature map. Conclusion : This work presented a rapid, and robust self-developed center array-sequencing PU algorithm feasible for the application of MR temperature mapping according to the PRF phase shift property.

  • PDF

An Evaluation of the Accuracy of Mini-Wright Peak Flowmeters in Patients with Asthma and Chronic Obstructive Pulmonary Disease (천식 및 만성폐쇄성폐질환 환자에서 Mini-Wright Peak Flowmeter로 측정한 최대호기유속의 정확도)

  • Choi, Won-Il;Han, Seung-Beom;Jeon, Young-June
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.3
    • /
    • pp.310-319
    • /
    • 2001
  • Background : The peak flowmeter is very useful in monitoring of out-patients as well as those in emergency departments because of its convenience and simplicity with low cost. There have been many studies aimed at determining the accuracy and reproducibility of the peak flow meter in normal population. However, there is a paucity of reports regarding its accuracy in patients with chronic obstructive pulmonary disease(COPD) or asthma. The accuracy of the peak expiratory flow(PEF) measured with a mini-Wright peak flowmeter was assessed by a comparison with the results of a mass flow sensor. Methods : The PEF measurements were performed in 108 patients aged 19-82 years presenting with either a chronic obstructive lung disease or asthma before and after inhaling salbutamol. The PEF measurements from the mini-Wright flowmeter were compared with those obtained by the calibrated mass flow sensor. Results : The average of the readings taken by the mini-Wright meter were 37-39 l/min higher than those taken by the mass flow sensor. The average percentage error of the mini-Wright meter were higher, ranging less than 300 l/min. The mean of the differences between the values obtained using both instruments (the bias)$\pm$limits of agreement(${\pm}2$ SD) were $37.1{\pm}90\;l/min$ for the PEF(p<0.001). Conclusions : The mini-Wright peak flowmeter overestimated the flows in patients with COPD or asthma. It was also found that the accuracy of the mini-Wright peak flowmeter decreased in its mid to low range. The limits of agreement are wide and the difference between the two instruments is significant. Therefore, the measurements made between the two types of machines in patients with asthma or COPD cannot be used interchangeably.

  • PDF

Novel Real Time PCR Method for Detection of Plasmodium vivax (새로운 Real Time PCR 방법을 통한 Malaria(Plasmodium vivax)의 검출)

  • Ki, Yeon-Ah;Kim, So-Youn
    • Microbiology and Biotechnology Letters
    • /
    • v.33 no.2
    • /
    • pp.148-153
    • /
    • 2005
  • Malaria is a re-emerging infectious disease that is spreading to areas where it had been eradicated, such as Eastern Europe and Central Asia. To avoid the mortality from malaria, early detection of the parasite is a very important issue. The peripheral blood smear has been the gold standard method for the diagnosis of malaria infection. Recently, several other methods have been introduced for quantitative detection of malaria parasites. Real time PCR that employs fluorescent labels to enable the continuous monitoring of PCR product formation throughout the reaction has recently been used to detect several human malaria parasites. 18S rRNA sequences from malaria parasites have been amplified using Taqman real time PCR assay. Here, a SYBR Green-based real time quantitative PCR assay for the detection of malaria parasite-especially, Plasmodium vivax - was applied for the evaluation of 26 blood samples from Korean malaria patients. Even though SYBR Green-based real time PCR is easier and cheaper than Taqman-based assay, SYBR Green-based assay cannot be used because 18S rRNA cannot be specifically amplified using 1 primer set. Therefore, we used DBP gene sequences from Plasmodium vivax, which is specific for the SYBR Green based assays. We amplified the DBP gene from the 26 blood samples of malaria patients using SYBR Green based assay and obtained the copy numbers of DBP genes for each sample. Also, we selected optimal reference gene between ACTB and B2M using real time assay to get the stable genes regardless of Malaria titer. Using selected ACTB reference genes, we successfully converted the copy numbers from samples into titer, ${\sharp}$ of parasites per microliter. Using the resultant titer from DBP based SYBER Green assay with ACTB reference gene, we compared the results from our study with the titer from Taqman-based assay. We found that our results showed identical tendency with the results of 18S rRNA Taqman assay, especially in lower titer range. Thus, our DBP gene-utilized real time assay can detect Plasmodium vivax in Korean patient group semi-quantitatively and easily.

A Conceptual Framework for One Source Multi Use Strategy of Culture Content (브랜드 아이덴티티 기반 문화콘텐츠 OSMU 전략 연구)

  • Kim, Young-Jae
    • Cartoon and Animation Studies
    • /
    • s.28
    • /
    • pp.155-180
    • /
    • 2012
  • This article is to propose a conceptual framework for the One Source Multi Use (OSMU) strategic model of culture content. In this study, OSMU is defined as a series of marketing activities to increase the value created by culture content. The framework of brand equity strategy is applied to develop the strategic model of OSMU, as both share the same goal - maximization of long term value created by brand or culture content. This article suggests the brand identity-based OSMU strategic model, in which the brand identity of culture content guides, integrates, and coordinates every decision-making of OSMU activities. For the maximization of brand equity value of culture content, the copyright holder of original content should decide the content's brand identity, which should provide the criteria of all decision makings regarding window strategy, adaptation of content to other genre, and merchandising. This brand identity-based OSMU strategic model can not only contribute to the sales of OSMU content, but also the creation of high equity culture content in the long run. Also, the model allows monitoring and evaluation of content's brand equity, which can be used for the strategic adjustment for the sake of long term value of the content. This study is differentiated from previous study on OSMU and expected to invigorate the further discussion on OSMU in several points. First, it broadens the scope of OSMU discussion as it views OSMU as a series of process including feedback. Second, this study points out the need for integration and coordination of various OSMU activities. Third, the strategic focus is laid on the value maximization of the original content, not 'multi used' content. Fourth, the suggested model emphasize the strategic role of copyright holder who takes the charge of the content brand management. Fifth, the model requires discussion on the components of marketing communication in addition to the content itself, which means the model includes the prospects, not only the content consumers, as the major future source for value creation.

Traumatic Contusion of ICR Mouse Brain by FPI : $^{1}\textrm{H}$ MR Spectroscopic Study (유체타진손상기법에 의한 ICR 쥐의 뇌손상: 자기공명분광법)

  • Park, Chi-Bong;Kim, Hwi-Yool;Jeun, Sin-Soo;Han, Young-Min;Han, Duk-Young;Kang, Young-Woon;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.14 no.4
    • /
    • pp.259-267
    • /
    • 2003
  • In vivo $^1$H magnetic resonance spectroscopy (MRS) at 4.7 T was applied to investigate the cerebral metabolite changes of mice brain before and after experimental brain trauma. In vivo $^1$H MR spectra were acquired from a voxel covering right parietal cortex in normal brain, used as control subjects. After experimental brain trauma using the fluid percussion injury (FPI) method, $^1$H MR spectra were acquired from the same lesion three days after trauma. Metabolite ratios of the injured lesion were compared to those of controls. After trauma, N-acetylaspartate (NAA)/creatine (Cr) ratio, as a neuronal marker was decreased significantly versus controls, indicating neuronal loss. The ratio of NAA/Cr in traumatic brain contusion was 0.90$\pm$0.11, while that in normal control subjects was 1.13$\pm$0.12 (P=0.001). Choline (Cho)/Cr ratio had a tendency to rise in experimental brain contusion (P=0.02). Cho/Cr ratio after trauma was 0.91$\pm$0.17 while that before traumas was 0.76$\pm$0.15. Cho/Cr ratio was increased and this might indicate a inflammatory activity. However, no significant difference of [(glutamate+glutamine) (Glx)]/Cr was established between experimental traumatic brain injury models and normal controls. Lactate (Lac)/Cr ratio was appeared as a sign of shifted posttraumatic energy metabolism and increased versus controls. These findings strongly suggest that in vivo $^1$H MRS may be a useful modality for clinical evaluation of traumatic contusion and could aid in better understanding the neuropathologic process of traumatic contusion induced by FPI. In the present study, in vivo $^1$H MRS was proved to be a useful non-invasive method for in vivo diagnosis and monitoring of posttraumatic metabolism in models of brain contusion.

  • PDF

Design and Implementation of Quality Broker Architecture to Web Service Selection based on Autonomic Feedback (자율적 피드백 기반 웹 서비스 선정을 위한 품질 브로커 아키텍처의 설계 및 구현)

  • Seo, Young-Jun;Song, Young-Jae
    • The KIPS Transactions:PartD
    • /
    • v.15D no.2
    • /
    • pp.223-234
    • /
    • 2008
  • Recently the web service area provides the efficient integrated environment of the internal and external of corporation and enterprise that wants the introduction of it is increasing. Also the web service develops and the new business model appears, the domestic enterprise environment and e-business environment are changing caused by web service. The web service which provides the similar function increases, most the method which searches the suitable service in demand of the user is more considered seriously. When it needs to choose one among the similar web services, service consumer generally needs quality information of web service. The problem, however, is that the advertised QoS information of a web service is not always trustworthy. A service provider may publish inaccurate QoS information to attract more customers, or the published QoS information may be out of date. Allowing current customers to rate the QoS they receive from a web service, and making these ratings public, can provide new customers with valuable information on how to rank services. This paper suggests the agent-based quality broker architecture which helps to find a service providing the optimum quality that the consumer needs in a position of service consumer. It is able to solve problem which modify quality requirements of the consumer from providing the architecture it selects a web service to consumer dynamically. Namely, the consumer is able to search the service which provides the optimal quality criteria through UDDI browser which is connected in quality broker server. To quality criteria value decision of each service the user intervention is excluded the maximum. In the existing selection architecture, the objective evaluation was difficult in subjective class of service selecting of the consumer. But the proposal architecture is able to secure an objectivity with the quality criteria value decision where the agent monitors binding information in consumer location. Namely, it solves QoS information of service which provider does not provide with QoS information sharing which is caused by with feedback of consumer side agents.

Evaluation of Space-based Wetland InSAR Observations with ALOS-2 ScanSAR Mode (습지대 변화 관측을 위한 ALOS-2 광대역 모드 적용 연구)

  • Hong, Sang-Hoon;Wdowinski, Shimon
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.5_1
    • /
    • pp.447-460
    • /
    • 2022
  • It is well known that satellite synthetic aperture radar interferometry (InSAR) has been widely used for the observation of surface displacement owing to earthquakes, volcanoes, and subsidence very precisely. In wetlands where vegetation exists on the surface of the water, it is possible to create a water level change map with high spatial resolution over a wide area using the InSAR technique. Currently, a number of imaging radar satellites are in operation, and most of them support a ScanSAR mode observation to gather information over a large area at once. The Cienaga Grande de Santa Marta (CGSM) wetland, located in northern Colombia, is a vast wetland developed along the Caribbean coast. The CGSM wetlands face serious environmental threats from human activities such as reclamation for agricultural uses and residential purposes as well as natural causes such as sea level rise owing to climate change. Various restoration and protection plans have been conducted to conserve these invaluable environments in recognition of the ecological importance of the CGSM wetlands. Monitoring of water level changes in wetland is very important resources to understand the hydrologic characteristics and the in-situ water level gauge stations are usually utilized to measure the water level. Although it can provide very good temporal resolution of water level information, it is limited to fully understand flow pattern owing to its very coarse spatial resolution. In this study, we evaluate the L-band ALOS-2 PALSAR-2 ScanSAR mode to observe the water level change over the wide wetland area using the radar interferometric technique. In order to assess the quality of the interferometric product in the aspect of spatial resolution and coherence, we also utilized ALOS-2 PALSAR-2 stripmap high-resolution mode observations.

Computer Aided Diagnosis System for Evaluation of Mechanical Artificial Valve (기계식 인공판막 상태 평가를 위한 컴퓨터 보조진단 시스템)

  • 이혁수
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.421-430
    • /
    • 2004
  • Clinically, it is almost impossible for a physician to distinguish subtle changes of frequency spectrum by using a stethoscope alone especially in the early stage of thrombus formation. Considering that reliability of mechanical valve is paramount because the failure might end up with patient death, early detection of valve thrombus using noninvasive technique is important. Thus the study was designed to provide a tool for early noninvasive detection of valve thrombus by observing shift of frequency spectrum of acoustic signals with computer aid diagnosis system. A thrombus model was constructed on commercialized mechanical valves using polyurethane or silicon. Polyurethane coating was made on the valve surface, and silicon coating on the sewing ring of the valve. To simulate pannus formation, which is fibrous tissue overgrowth obstructing the valve orifice, the degree of silicone coating on the sewing ring varied from 20%, 40%, 60% of orifice obstruction. In experiment system, acoustic signals from the valve were measured using microphone and amplifier. The microphone was attached to a coupler to remove environmental noise. Acoustic signals were sampled by an AID converter, frequency spectrum was obtained by the algorithm of spectral analysis. To quantitatively distinguish the frequency peak of the normal valve from that of the thrombosed valves, analysis using a neural network was employed. A return map was applied to evaluate continuous monitoring of valve motion cycle. The in-vivo data also obtained from animals with mechanical valves in circulatory devices as well as patients with mechanical valve replacement for 1 year or longer before. Each spectrum wave showed a primary and secondary peak. The secondary peak showed changes according to the thrombus model. In the mock as well as the animal study, both spectral analysis and 3-layer neural network could differentiate the normal valves from thrombosed valves. In the human study, one of 10 patients showed shift of frequency spectrum, however the presence of valve thrombus was yet to be determined. Conclusively, acoustic signal measurement can be of suggestive as a noninvasive diagnostic tool in early detection of mechanical valve thrombosis.

Ecological Risk Assessment of Residual Petroleum Hydrocarbons using a Foodweb Bioaccumulation Model (먹이연쇄 생물축적 모형을 이용한 잔류유류오염물질의 생태위해성평가)

  • Hwang, Sang-Il;Kwon, Jung-Hwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.11
    • /
    • pp.947-956
    • /
    • 2009
  • Residual petroleum hydrocarbons after an oil spill may accumulate in the marine benthic ecosystem due to their high hydrophobicity. A lot of monitoring data are required for the estimation of ecosystem exposure to residual petrochemicals in an ecological risk assessment in the affected region. To save time and cost, the environmental exposure to them in the affected ecosystem can also be assessed using a simple food-web bioaccumulation model. In this study, we evaluated residual concentrations of four selected polycyclic aromatic hydrocarbons (phenanthrene, anthracene, pyrene, and benzo[a]pyrene) in a hypothetic benthic ecosystem composed of six species under two exposure scenarios. Body-residue concentration ranged 5~250 mg/kg body depending on trophic positions in an extreme scenario in which the aqueous concentrations of PAHs were assumed to be one-tenth of their aqueous solubility. In addition, bioconcentration factors (BCFs) and bioaccumulation factors (BAFs) were evaluated for model species. The logarithm of bioconcentration factor (log BCF) linearly increased with increasing the logarithm of 1-octanol-water partition coefficient (log $K_{OW}$) until log $K_{OW}$ of 7.0, followed by a gradual decrease with further increase in log $K_{OW}$ without metabolic degradation. Biomagnification became significant when log $K_{OW}$ of a pollutant exceeded 5.0 in the model ecosystem, indicating that investigation of food-web structure should be critical to predict biomagnifications in the affected ecosystem because log $K_{OW}$ values of many petrochemicals are higher than 5.0. Although further research is required for better site-specific evaluation of exposure, the model simulation can be used to estimate the level of the ecosystem exposure to residual oil contaminants at the screening level.