• 제목/요약/키워드: Monitoring and control interface

검색결과 305건 처리시간 0.026초

Development of Long-Term Storage Technology for Chinese Cabbage - Physiological Characteristics of Postharvest Freshness in a Cooler with a Monitoring and Control Interface

  • Lim, Ki Taek;Kim, Jangho;Chung, Jong Hoon
    • Journal of Biosystems Engineering
    • /
    • 제39권3호
    • /
    • pp.194-204
    • /
    • 2014
  • Purpose: The aim of this study was to develop long-term storage technology for Chinese cabbage in order to extend the period of availability of freshly harvested products. The scope of the paper deals with the use of a cooler with a remote monitoring and control interface in conjunction with use of packaging film. Methods: A cooler with a real time monitoring system was designed as a low-temperature storage facility to control temperature and relative humidity (RH). The effects of storage in high-density polyethylene (HDPE) plastic boxes, 3% chitosan dipping solution, polypropylene film (PEF) with perforations, and mesh packaging bags on physiological responses were investigated. The optimal storage temperature and humidity for 120 days were below $0.5^{\circ}C$ and 90%, respectively. Physiological and biochemical features of cabbage quality were also analyzed: weight loss, texture, and sugar salinity, chlorophyll, reducing sugar, and vitamin C contents. Results: The cooler with a remote monitoring and control interface could be operated by an HMI program. A $0.5^{\circ}C$ temperature and 90% humidity could be remotely controlled within the cooler for 120 days. Postharvest freshness of Chinese cabbages could be maintained up to 120 days depending on the packaging method and operation of the remote monitoring system. In particular, wrapping the cabbages in PEF with perforations resulted in a less than a 5% deterioration in quality. This study provides evidence for efficient performance of plastic films in minimizing post-harvest deterioration and maintaining overall quality of cabbages stored under precise low-temperature conditions with remote monitoring and a control interface. Conclusions: Packaging with a modified plastic film and storage in a precisely controlled cooler with a remote monitoring and control interface could slow down the physiological factors that cause adverse quality changes and thereby increase the shelf life of Chinese cabbage.

CAN 기반 제어 시스템 분석을 위한 인터페이스 유닛 설계 및 구현 (Design and Implementation of an Interface Unit for Analysis of a CAN-Based Control System)

  • 박병률;정구민;안현식;김도현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.195-197
    • /
    • 2006
  • In this paper, an interface unit is designed to efficiently monitor transmission data in Controller Area Network(CAN)-based control systems. The CAN uses a serial multi master communication protocol that efficiently supports distributed real-time control with a very high level of data integrity, and communication speeds of up to 1Mbps. The interface unit is composed of a DSP controller which collects data on the CAN bus and transfers data to a personal computer via serial communication to save and display of interesting signals. The experimental system consists of three DSP controllers which represent electronic control units of a vehicle, an interface unit for analysing the data on the bus, and a graphic monitoring program coded on the Windows platform. The validity and the effectiveness of the proposed simple type of CAN interface unit are shown through the experimental results.

  • PDF

GPS/INS 통합 항법 시스템용 모니터링 시스템 설계 (Monitoring System Design for the GPS/INS Integrated Navigation System)

  • 한상재;오상헌;황동환;이상정
    • 제어로봇시스템학회논문지
    • /
    • 제9권3호
    • /
    • pp.242-250
    • /
    • 2003
  • We propose the monitoring system scheme for the CPS/INS integrated navigation system. The design requirements of the monitoring system are suggested and the software scheme based on GUI is proposed. The proposed monitoring system consists of an I/O interface part, a navigation data display part, and a post-processing part. The I/O interface part is responsible for data communication between the monitoring system and a navigation computer unit. The navigation data display part provides various display methods to show the navigation data to user in real-time. The post-processing part collects the navigation data to analyze the performance of navigation system. The proposed monitoring system software was developed using the Visual C++ programming language and a van test was carried out to demonstrate the real-time operation of the monitoring system. The test result shows that the proposed monitoring system can be effectively applied to the CPS/INS integrated navigation system.

최신 프로세서 탑재 비행제어 컴퓨터의 통합시험을 위한 프로세서 모니터링 연구 (A Study on Processor Monitoring for Integration Test of Flight Control Computer equipped with A Modern Processor)

  • 이철;김재철;조인제
    • 제어로봇시스템학회논문지
    • /
    • 제14권10호
    • /
    • pp.1081-1087
    • /
    • 2008
  • This paper describes limitations and solutions of the existing processor-monitoring concept for a military supersonics aircraft Flight Control Computer (FLCC) equipped with modern architecture processor to perform the system integration test. Safecritical FLCC integration test, which requires automatic test for thousands of test cases and real-time input/output test condition generation, depends on the processor-monitoring device called Processor Interface (PI). The PI, which relies upon on the FLCC processor's external address and data-bus data, has some limitations due to multi-fetching capability of the modern sophisticated military processors, like C6000's VLIW (Very-Long Instruction Word) architecture and PowerPC's Superscalar architecture. Several techniques for limitations were developed and proper monitoring approach was presented for modem processor-adopted FLCC system integration test.

A Remote Monitoring and Control System for Waste Treatment Facility via Public Communication Network.

  • Jung, Jae-Hak;Choi, Jin-Yong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.124.2-124
    • /
    • 2001
  • The research for development of remote monitoring and control systems composed three stages of research categories. At the first stage, we decided the suitable instrumentation devices for interface between H/W systems and waste water treatment facility. And at the second stage, we developed the software package for remote monitoring and data transmission system including data receipt system via wired telephone line. At the final stage we developed local control system for auto-process control of waste water treatment facilities. For the first stage of research we developed the a drawing of design the instrumentation and selected optimal sensors or monitoring basic important data. After the first stage research we developed the software package with Graphic User Interface(GUI) ...

  • PDF

Design and Implementation of a Framework for Automatically Generating Control and Monitoring Software

  • Yoo, Dae-Sung;Sim, Min-Suck;Park, Sung-Ghue;Kim, Jong-Hwan;Yi, Myeong-Jae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.932-935
    • /
    • 2004
  • In this paper, we present a framework that is easy to develop, modify, maintain and extend a control and monitoring software for any kinds of instruments. The presented framework is composed of three XML documents (IID, MAP, and CMIML) and two tools (Virtual Instrument Wizard, Generator). Interface information about behaviors and states of instruments is written on IID. Mapping information between the interface information in IID and API of a real instrument driver is written on MAP. Finally information about control and monitoring software is written on CMIML. IID, MAP and CMIML are written with XML format to provide common usage and platform independence of the suggested framework. VI Wizard generates CMIML (platform independent intermediate document) using IID and existing CMIML, and Generator generates source code of a control and monitoring software (platform dependent code) automatically using CMIML and MAP. The suggested framework that automatically generates control and monitoring software based on GUI provides easy development and maintenance. Also, reusability can be increased by reusing platform independent software description documents.

  • PDF

Interface monitoring of steel-concrete-steel sandwich structures using piezoelectric transducers

  • Yan, Jiachuan;Zhou, Wensong;Zhang, Xin;Lin, Youzhu
    • Nuclear Engineering and Technology
    • /
    • 제51권4호
    • /
    • pp.1132-1141
    • /
    • 2019
  • Steel-concrete-steel (SCS) sandwich structures have important advantages over conventional concrete structures, however, bond-slip between the steel plate and concrete may lead to a loss of composite action, resulting in a reduction of stiffness and fatigue life of SCS sandwich structures. Due to the inaccessibility and invisibility of the interface, the interfacial performance monitoring and debonding detection using traditional measurement methods, such as relative displacement between the steel plate and core concrete, have proved challenging. In this work, two methods using piezoelectric transducers are proposed to detect the bond-slip between steel plate and core concrete during the test of the beam. The first one is acoustic emission (AE) method, which can detect the dynamic process of bond-slip. AE signals can be detected when initial micro cracks form and indicate the damage severity, types and locations. The second is electromechanical impedance (EMI) method, which can be used to evaluate the damage due to bond-slip through comparing with the reference data in static state, even if the bond-slip is invisible and suspends. In this work, the experiment is implemented to demonstrate the bond-slip monitoring using above methods. Experimental results and further analysis show the validity and unique advantage of the proposed methods.

JMF 기반의 실시간 원격 공정 감시 및 제어 시스템 설계 및 구현 (Design md Implementation for the Remote Real Time Process Monitoring and Control System based on the JMF)

  • 김삼룡;임인택;이정배
    • 정보처리학회논문지D
    • /
    • 제11D권2호
    • /
    • pp.453-460
    • /
    • 2004
  • 본 논문에서는 I/O 인터페이스 제어 보드와 ISA 인터페이스 제어 보든 그리고 레고 기반의 프로토타이핑(Prototyping)을 통해 실시간 신발 공정 컨베이어 제어를 위한 원격 감시 및 제어 시스템을 구현하였다. 컨베이어 서버에서 실시간으로 공정을 제어하기 위하여 작업의 우선권을 사용자가 정할 수 있는 RTLinux(Real-Time Linux)를 사용하였으며, RTLinux 기반으로 디바이스 드라이버를 작성하였다. 이를 통해 Client/Server 분산 환경 시스템의 구현 및 테스트를 하며, JMF(Java Media Framework) 기반의 모니터링 시스템을 구현하여 전체 공정 상황을 확인하였다.

디지털 트윈을 활용한 실시간 모니터링 및 원격제어 시스템의 테스트베드 구현 (Implementation of Real-time Monitoring and Remote Control System Testbed based on Digital Twin)

  • 윤정은;김원석
    • 한국멀티미디어학회논문지
    • /
    • 제25권2호
    • /
    • pp.325-334
    • /
    • 2022
  • Digital twin has the advantages of quality improvement and cost reduction, so it is widely applied to various industries. In this paper, a method to implement the major technologies of digital twin easily and quickly is presented. These include data management and relay servers, real-time monitoring applications including remote control interfaces, and direct connection protocols for video streaming. In addition, an algorithm for controlling a two-wheeled vehicle with a 2D interface is also proposed. The implemented system performs near real-time synchronization between the real environment and the virtual space. The delay time that occurs in remote control of the vehicle in the real environment was compared with the results of applying the proposed delay time reduction method. In addition, in the case of 2D interface-based control, an algorithm that can guarantee the user experience was implemented and applied to the actual environment and verified through experiments.

마이크로프로세서를 이용한 인터넷 원격감시제어 시스템에 관한 연구 (A study on the Internet control and monitoring system using a microprocessor embedded controller)

  • 서인호;문복산;김경엽;김영일;천행춘;유영호
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2000년도 추계학술대회 논문집(Proceeding of the KOSME 2000 Autumn Annual Meeting)
    • /
    • pp.152-156
    • /
    • 2000
  • Many industrial equipments use RS-232C interface. But Ethernet using CSMA/CD was widly spread recently. This interface is not compatible with RS-232C and requires PC based system. So In this Paper, We decribe a Internet control and monitoring system that control and watch plants without PC. We developed IP controller consisted of microprocessor and NIC and monitoring system using VC++ and SQL database. The protocol used this system is UDP/IP because it is applicable for real time system.

  • PDF