• Title/Summary/Keyword: Monitoring and Feedback System

Search Result 145, Processing Time 0.029 seconds

Development of Fiber Optic Sensor for Monitoring Magnetic Bearing (자기베어링 모니터링용 광파이버센서 개발에 관한 연구)

  • 홍준희;한복수
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.1
    • /
    • pp.65-71
    • /
    • 2003
  • In a high speed spindle system it is very important to monitor the state of rotating rotor. Particularly in active control spindle system the position sensor must provide feedback to the control system on the exact position of the rotor. In order to monitor the state of a high speed spindle exactly, high accuracy and wide frequency bandwidth of sensors are important. The focus in this paper is to make a fiber optic sensor for monitoring rotor of magnetic bearing, to design the circuit for detecting optical signal, and to evaluation static and dynamic characteristics of fiber optic sensor.

The Performance Evaluation of Fiber Optic Sensor for Monitoring Magnetic Bearing (자기베어링 모니터링용 광파이버센서의 성능 평가)

  • 박한수;정택구;홍준희;이동주
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.411-416
    • /
    • 2002
  • In a high speed spindle system, it is very important to monitor the state of rotating rotor. Particularly in active control spindle system, the position sensor must provide feedback to the control system on the exact position of the rotor. In order to monitor the state of a high speed spindle exactly, high accuracy and wide frequency bandwidth of sensors are important. The focus in this paper is to make a fiber optic sensor for monitoring rotor of magnetic bearing, to design the circuit for detecting optical signal, and to evaluation static and dynamic characteristics of fiber optic sensor.

  • PDF

Information Activity Monitoring for Enhancing the Utilization of the Enterprise Information System (기업 정보 시스템의 활용도 향상을 위한 정보활동 모니터링)

  • Han, Kwan-Hee;Song, Hee-Seok
    • The KIPS Transactions:PartD
    • /
    • v.13D no.5 s.108
    • /
    • pp.749-754
    • /
    • 2006
  • Recently, many enterprises are introducing information systems for their competitive advantages. For enhancing the utilization level of enterprise information system, it is quite important to monitor the usage states of the information systems continuously. However, most enterprise information systems lack this functionality. Proposed in this paper is the framework of IAM (Information Activity Monitoring), which is defined as real-time reporting and alerting of significant information-related activities. This IAM framework provides 4 different views about the information system (data, IT system, business process, and participant) and is implemented as a part of integrated design/manufacturing information system developed by aerospace parts manufacturer. By using the IAM function, IT personnel can monitor significant information-related activities systematically and feedback to their users timely, and ultimately enhance the utilization level of information system.

Automatic Flow Control and Network Monitoring of IV Injection (자동 IV 주사 유량 자동 제어 및 네트워크 모니터링)

  • Kim, Jin-Nam;Kwon, Won-Tae;Lee, Kang-Hee
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.1
    • /
    • pp.161-166
    • /
    • 2012
  • Intravenous (IV) injection is widely used to supply Ringer solution directly into a vein in hospital. Generally, a passive injection method has been used, which causes the inconsistent flow rate of fluid and inappropriate control of injection time by a patient. It leads to an unnecessary nurse's overwork and decrement of IV injection's effect. To solve these problems, flow control infusion pumps have been developed. But because of relatively heavy weight and high price, its usage has been limited. In the present study, a new automatic IV injection system is developed. It is installed with a small pressing mechanism driven by a small electric motor to regulate the flow rate by pressing tube. Proportional integral derivative (PID) feedback control algorithm is applied to control the electric motor. The system is smaller in size and uses lower power than the existing commercial product. The newly developed system is also installed with networking capability, which enables monitoring the status of several automatic IV injection system at the same time.

Development of Distribution Superconducting Fault Current Limiter and its Monitoring System for Power IT Application (배전급 초전도한류기 및 전력 IT 응용을 위한 실시간 모니터링 시스템 개발)

  • Park, Dong-Keun;Seok, Bok-Yeol;Ko, Tae-Kuk;Kang, Hyoung-Ku
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.398-402
    • /
    • 2008
  • Recently, the development of superconducting fault current limiters (SFCLs) has been required as power demands increase in the power system. A distribution-level prototype resistive SFCL using coated conductor (CC) has been developed by Hyundai Heavy Industries Co., Ltd. and Yonsei University for the first time in the world. The ratings of the SFCL are 13.2kV/630A at normal operating condition. A novel non-inductive winding method is used in fabricating coils so there is almost zero impedance during normal operation. The distribution SFCL is cooled by sub-cooled liquid nitrogen $(LN_2)$ of 65K and 3 bar to enhance cryo-dielectric performance, critical current density, and thermal conductivity. In order to make reliable operation of an SFCL in real power systems, we monitored and controled its operation conditions by using supervisory control and data acquisition (SCADA) method. Thus, a monitoring system for the SFCL employing information technology (IT) is proposed and developed to be on the lookout for the operation conditions such as inside temperature, inside pressure, $LN_2$ level, voltage and current. Since operation temperature should be kept constant, bang-bang control for temperature feedback with a heater attached to the cold head of cryo-cooler is applied to the system. Short-circuit tests with prospective fault current of 10kA and AC dielectric withstand voltage tests up to 143kV for 1 minute were successfully performed at Korea Electrotechnology Research Institute. This paper deals with the development of a distribution level SFCL and its monitoring system for reliable operation.

A Study on the Improvement of the Effectiveness of Feedback of Government Performance Evaluation (정부업무평가의 환류 효용성 제고방안에 관한 연구)

  • Yuiryong Jung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.3
    • /
    • pp.541-550
    • /
    • 2024
  • The aim of this study is to find a way to improve the effectiveness of feedback that can contribute to the development of government work evaluation through comparison of systems between Korea and the United States. To this end, this study compared and analyzed the cases of Korea and the United States in relation to the feedback system of political affairs evaluation. In the case of the United States, it was confirmed that it was linked to a relatively high level of the learning dimension of the feedback system of achieving and improving policy goals, while in Korea, such linkage was segmented and controlled. In the case of Korea, it was confirmed that the government work evaluation system was in power, and its purpose was to improve policies and to control the evaluation target rather than learning for it. In the case of the United States, it is noteworthy that the autonomy of its own ministries is guaranteed as much as possible, the clarity and achievement of the goals presented by the ministries are prioritized, and the feedback also has a support and learning system as a regular system, not an ex post system. It is necessary to focus on policy improvement that can be linked to the achievement of policy goals in government work evaluation. It is also necessary to take a quarterly monitoring system, but to transform the ex post evaluation system into a learning and supportive system that can achieve policy goals, not control.

Dynamic Resistance Monitoring in Primary Circuit during Resistatnce Spot Welding (저항 점용접의 1차 회로 동저항 모니처링에 관한 연구)

  • 조용준;황정복;신현일;배경민;권태용;이세헌
    • Proceedings of the KWS Conference
    • /
    • 1998.10a
    • /
    • pp.129-132
    • /
    • 1998
  • The dynamic resistance monitoring in primary circuit or T/C is one of the important issues in that in-process and real time quality assurance of resistance spot weld is needed to increase the product reliability. It is well known that tile dynamic resistance curve gives us very useful information about nugget growth and weldability. In the present paper, a new dynamic resistance detecting method is presented as a practical manner of weld quality assurance using instantaneous current and voltage measured by primary circuit. Primary dynamic resistance patterns are basically similar to those of the secondary, but there is evident advantage such as no extra devices are needed to obtain the quality assurance index and eventually feedback control will be possible caused by T/C based monitoring system.

  • PDF

Resolved Motion Control of the Robot Manipulator using Neural Network (신경회로망을 이용한 로보트 매니츌레이터의 Resolved Motion제어기의 설계)

  • 송문철;조현찬;이홍기;전홍태
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.5
    • /
    • pp.519-526
    • /
    • 1990
  • In this paper we propose the resolved motion controller using a neural network for a robot manipulator. Neural identifier designed by a neural network is trained by using a feedback force as an error signal. The identifier approximates the output of a unknown nonlinear system by monitoring both the input and the output of this system. If the neural network is sufficiently trained well, it does not require either strict modelling of the manipulator or precise parameter estimation. The effectiveness of the proposed controller is demonstrated by computer simulation using a two-link planar robot.

  • PDF

Parameter estimation of the Diffusion Model for Demand Side Management Monitoring System (DSM Monitoring을 위한 확산 모델의 계수 추정)

  • Choi, Cheong-Hun;Jeong, Hyun-Su;Kim, Jin-O
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1073-1075
    • /
    • 1998
  • This paper presents the method of parameter estimation of diffusion model for monitoring Demand-Side Management Program. Bass diffusion model was applied in this paper, which has different values according to parameters ; coefficients of innovation, imitation and potential adopters. Though it is very important to estimate three parameter, there are no empirical results in practice. Thus, this paper presents the method of parameter estimation in case of few data with constraints to reduce the possibility of bad estimation. The constraints are empirical results or expert's decision. Case studies show the diffusion curves of high-efficient lighting and also forecasting of the peak value for power demand considering diffusion of high-efficient lighting, the feedback and least-square parameter estimation method used in this paper enable us to evaluate the status and forecasting of the effect of DSM program.

  • PDF

A Scheme to Improve QoS in a Multi-Virtual-Hosting Server (다중 Virtual Hosting Server의 QoS 향상 기법에 관한 연구)

  • Ryou, Sang-Woo;Ko, Soung-Jun;Lee, Sang-Moon;Kim, Hag-Bae;Park, Jin-Bae;Jang, Whie
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.4
    • /
    • pp.303-307
    • /
    • 2002
  • Virtual hosting is a typical service to connect each directory of site and domain name. If traffic amounts may increase at one site present in the server, then it affects traffic amounts of other sites as well (including the sites which have flew requests). To overcome this problem, we suggest a simple feedback-control concept for the system by periodically monitoring the traffic and properly actuating traffic dispersions by investigating the log file. Specifically, large files are to be served in a backup server (to reduce the workload of the main server) by changing their own URL's in html format. In other words, it automatically redistributes the workload by using the URL. Furthermore, we also use the redirecting method by just adding html tags to html header. This method efficiently handles the workload and maintains the capability of the server effectively to the varying workload.