오스템퍼 구상흑연주철의 충격인성에 미치는 Mo 및 Ni의 영향 (The Effects of Molybdenum and Nickel Addition on Impact Toughness of Austempered Ductile Cast Iron)

  • 박윤우;장현구
    • 한국주조공학회지
    • /
    • 제8권4호
    • /
    • pp.459-466
    • /
    • 1988
  • This study was carried out in the austempering temperature and time after Ni, Mo addition in purpose of modification of impact toughness of austempered ductile irons. Addition of alloy element and austempering treatment of $900^{\circ}C$ 60 minutes followed by $300^{\circ}C$, $350^{\circ}C$ and $400^{\circ}C$ for 60 minutes, in this case impact value was increased by ideal mixed structure. But impact value was decreased when holing time is 120minutes, this is attributed to segregation and carbide precipitation from high carbon austenite. Highest impact value was obtained by $350^{\circ}C$ (Mo-addition) and $400^{\circ}C$ (Ni-addition). This phenomena was caused by presence of remained austenite. At all austempering temperature,, Ni-added specimen showed higher impact values than that of Mo-added specimen. And hardness property was affected by austempering temperature and holding time rather than amounts of alloying element.

  • PDF

Seat recliner용 sector gear의 fine blanking에 관한 연구 (A study on properties of sector gear for seat recliner)

  • 김창호;강수호;이관영;남기우
    • 한국기계가공학회지
    • /
    • 제9권1호
    • /
    • pp.99-105
    • /
    • 2010
  • This study was performed to solve the breaking problem in the fine blanking(FB) process of sector gears for car seat recliner using nickel chrome molybdenum steel(SNCM220) plate. The optimal design of embossing circle is changed to oval with labors' experiences and finite element analysis. The maximum principal stress and effective strain in a forming process are analyzed by commercial finite element software to solve the problems in embossing stage of FB process. As a result of FE analysis, the maximum principal stress in forming is lower than yield point of material. It is shown from experiments in the modified die that the formed gear does not break in embossing stage.

Development of a Ultrasonic System for Nano-Surface Reformation Process

  • Kim, Hyunse;Lim, Euisu;Park, Jong-Kweon
    • 한국생산제조학회지
    • /
    • 제26권4호
    • /
    • pp.365-370
    • /
    • 2017
  • In this article, a 20 kHz Titanium (Ti) ultrasonic waveguide system for a nano-surface reformation process was designed and fabricated. First, finite element analysis using ANSYS software was performed to find the optimal dimensions. The obtained anti-resonance frequency for the Ti transducer with the piezoelectric device was 20.0 kHz, which value agreed well with the experiment result of 20.1 kHz (0.5% error). To test the system, chromium molybdenum steel (SCM) 435 was chosen as a test-piece. The result proved that the reformed depth was $36{\mu}m$. In addition, hardness was measured before and after the process. The value was changed from 14 HRC to 21 HRC, which is 50% increasing rate. Finally, the friction coefficient test result showed that the surface coefficient was reduced from 0.14 to 0.10 (28.6% reduction). Based on the results, the Ti ultrasonic equipment is regarded as a useful device for nano-scale surface reformation.

나노표면개질 용 초음파 진동자 설계 및 제작 (Design and Manufacturing of an Ultrasonic Waveguide for Nano-surface Treatment)

  • 김현세;이양래;임의수
    • 한국정밀공학회지
    • /
    • 제31권12호
    • /
    • pp.1115-1119
    • /
    • 2014
  • In this article, a 20 kHz ultrasonic waveguide for nano-surface treatment was designed and manufactured. When designing the system, finite element analysis with ANSYS software was performed to find optimal dimensions of the waveguide, which can raise energy efficiency. Consequently an anti-resonance frequency of an Al waveguide with a piezoelectric actuator was 20 kHz, which predicted the experimentally obtained value of 18 kHz well. For the assessment of the performance, Steel Use Stainless (SUS) 304 and chromium molybdenum steel (SCM) 435 specimens were tested. Cross-sectional microscopies of SUS304 were taken and they showed that the treated thickness was $30{\mu}m$. Additionally, hardness tests of SCM435 were done and the hardness before the process was 14.0 Rockwell Hardness-C scale (HRC) and after the process was 20.5 HRC, respectively, which means 46% increase. Considering these results, the developed ultrasonic system is thought to be effective in the nano-surface treatment process.

440A 강의 입계부식에 미치는 합금원소와 열처리의 영향(II) (The Effect of Alloying Elements and Heat Treatment on the Intergranular Corrosion of 440A Martensitic Stainless Steel(II))

  • 김영철;정병호;강창룡
    • 동력기계공학회지
    • /
    • 제15권3호
    • /
    • pp.52-57
    • /
    • 2011
  • 440A martensitic stainless steels which were modified with reduced carbon content(~0.5wt.%) and addition of small amount of vanadium, tungsten and molybdenum 0.4wt.%, 0.4wt.% and 0.68wt.% respectively were manufactured. Effects of alloying elements and tempering temperatures on the intergranular corrosion were investigated through the method of DL-EPR(Double-electrochemical potentiodynamic reactivation). It was thought that the highest DOS(Degree of sensitization) of specimens was obtained at the tempering temperature of $450^{\circ}C$ regardless of types of alloy because of the precipitation of Cr7C3. Addition of vanadium lowered DOS a little above the tempering temperature of $550^{\circ}C$. It was considered to be effected by precipitation of VC carbides. Intergranular corrosion was influenced more by tempering temperature than by alloying elements of V, W and Mo.

부분 모델을 이용한 접촉하중을 받는 코팅층이 있는 부재의 열적/기계적 응력해석 (Thermo-Mechanica1 Stress Analyses of Part with Coated Layer under Contact Load Using Partial Model)

  • 권영두;김석삼;신세현;추상우
    • Tribology and Lubricants
    • /
    • 제18권3호
    • /
    • pp.228-234
    • /
    • 2002
  • Generally, space structures are subjected to severe situations, such as, sublimation, strong evaporation of lubricants, thermal stresses, high temperature gradients, irradiation, impacts by microscopic meteorites, and other factors. Recent]y, various kinds of coatings are applied to the parts under heavy contact stresses, in order to insure long wear-free lives and/or reduce friction coefficients. In space structures, molybdenum disulfide is using frequently. Moreover TiN, Al$_2$O$_3$, PTFE(Poly Tetra Fluor Ethylene) are introduced recently for space structure. In this part we are going to apply the partial model method, developed in reference[11] to analyze part with coated layer. In referencer[l1], we compute the reasonable size of partial model and aspect ratio. Using these data, we analyze the structures coated with TiN, Al$_2$O$_3$, PTFE under contact load, temperature and crack model . Beside, we consider the stress analysis under time dependent load and transient thermal effect.

한약재내의 미량원소의 의의와 치료효과에 대한 고찰 (Therapeutical Effect with Trace Elements in Herbal Medicine)

  • 박해모;이선동
    • 대한예방한의학회지
    • /
    • 제4권2호
    • /
    • pp.25-56
    • /
    • 2000
  • Trace element are involved in enzymatic activities, immunological reactions. physiological mechanisms. Deficiency in some trace elements, such as iron and iodine. is still an important health problem, The role of trace elements deficiency is suspected in various clinical situations and is now confirmed by well designed supplementation studies. However, the importance of trace elements as chinese herbal constituents is not sufficiently appreciated by the oriental medical profession, although in recent years a significant increase of new finding on their essential character in chinese herbal medicine occurred. It is well known that herbal medicine contains a variety of trace elements which would show therapeutic effects with active components in herbal medicine . In china, recent work showed some positive correlation between trace element and traditional chinese medicine (TCM) in terms of therapeutic effects even if their role in therapeutic effects is still obscure. In korea, not much attention has been on the therapeutic importance of trace element contained in herbal medicine Here, the therapeutic effects of trace element in TCM were reviewed and summarized. 1. Iron, copper, zinc and manganese are mainly contained in TCM. In addtion, chromium, magnesium, molybdenum, nickel, alminium, cobalt, arsenic and selenium has been studied for their therapeutic effects 2. Zinc, is decreased in patients who have deficiency of kindney(腎虛) and chronic disease. Fe is decreased in patients who have deficiency of blood(血虛). However copper is increased in patients who have chronic disease and hepatic disease.3 Iron concentration is high in herbs used for tonifying and nourishing yin or blood(補陰補血藥) Zinc concentration is high also in herb used for tonifying kidiney and vital essence(補腎補精藥). In addition. copper concentration Is high in herb used for replenishing qi(補氣藥) 4 In herbal drugs, the therapeutic substances in TCM are not only organic but also inorganic. It seems that trace elements would be one of components in herb for its therapeutic effects. This indicates that therapeutic effects of TCM should be extended not only to herb itself, bur also to trace elements contained in herb.

  • PDF

퇴비원료기준 확대설정을 위한 유기성자원의 미량원소 및 PAHs 분포 연구 (Study of Trace Element and PAHs Distribution for Extensive Regulation Establishment in Raw Material of Compost on Organic Resource)

  • 임동규;이승환;권순익;성기석;이정택;송범헌
    • 한국토양비료학회지
    • /
    • 제39권6호
    • /
    • pp.339-344
    • /
    • 2006
  • 유기성 폐자원을 퇴비원료로서 재활용하는데 대한 규정에는 현재 유기물과 8종의 중금속 함량에 대한 기준만 있기 때문에 미량원소(붕소, 코발트, 몰리브덴 및 셀레늄) 및 유해 유기화합물(PAHs) 함량을 기준 항목으로 추가하기 위하여 전국 6 2개소에서 채취한 16종에 대한 성분분석을 실시한 결과는 다음과 같다. 붕소의 경우 피혁오니가 $154.2mg\;kg^{-1}$, 식품오니가 $57.1mg\;kg^{-1}$로 가장 높았고, 코발트는 공단지역 하수오니에서 $95.2mg\;kg^{-1}$, 대도시 하수오니에서 $22.9mg\;kg^{-1}$, 몰리브덴은 식품오니에서 $16.8mg\;kg^{-1}$, 대도시 하수오니에서 $40.1mg\;kg^{-1}$, 셀레늄은 섬유오니에서 $28.1mg\;kg^{-1}$, 피혁오니에서 $16.9mg\;kg^{-1}$ 그리고 식품오니에서 $15.9mg\;kg^{-1}$으로 가장 높았다. 유해 유기화합물 중 총 PAHs는 제지오니에서 $3,462ug\;kg^{-1}$로 가장 높았고, PAHs의 성분별 비교해 보면, naphthalene, phenanthrene, pyrene, fluoroanthene, anthracene 및 acenaphthene의 함량이 다른 화합물보다 현저히 높은 것으로 나타났다. 따라서 현재 우리나라에서 유기성자원의 퇴비원료로 활용에 대한 기준은 유기물함량과 중금속(8성분: Zn, Cu, Cr, Pb, Ni, Cd, As, Hg)으로 규제하고 있으나, 미량원소(B, Co, Mo, Se), 유해 유기화합물(PAHs)에 대한 보완연구를 통해 퇴비원료기준에 규제기준을 추가하여 선별체계를 확립한다면, 유기성 폐기물도 자원으로써 농업적인 재활용이 가능하다고 생각된다.

Ruminal Solubility of Trace Elements from Selected Philippine Forages

  • Serra, S.D.;Serra, A.B.;Ichinohe, T.;Fujihara, T.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제10권4호
    • /
    • pp.378-384
    • /
    • 1997
  • The ruminal solubility of copper (Cu), manganese (Mn), molybdenum (Mo), and zinc (Zn) in eight Philippine forages was studied. These forages were: 1) grasses: paragrass (Brachiaria mutica (Forsk.) Stapf), stargrass (Cynodon plectostachyum Pilger), and napiergrass (Pennisetum purpureum Schumach.); 2) creeping legumes: calopogonium or calopo (Calopogonium muconoides Desv.) and centrocema (Centrocema pubescens Benth.); 3) tree lequmes: gliricidia or kakawate (Gliricidia sepium (Jacq.) Walp.), leucaena or ipil-ipil (Leucaena leucocephala (Lam.) de Wit.), and sesbania or katuray (Sesbania grandiflora (L.) Poir). Nylon bags with samples were incubated for 0, 3, 6, 12, 24, 48 and 72h in three rumen cannulated sheep fed with timothy hay (Phleum pratense L.) at 2% body weight/d. The 0-h bags were washed with deionized water. There were species differences (p < 0.05) on the different solubilities of trace elements. At O-h incubation, the trend of solubility was Mo (54%) > Zn (43%) > Cu (38.7%) > Mn (29.5%). At 3-h incubation, all the elements except Mn had an average solubility above 50%. Combining particulate passage rate (1.9%/h) and various trace elements disappearance rates, the effective ruminal solubilization (ERS) of trace elements were computed. The ERS across species ranged from 44.6 to 89.9% for Cu, 29.9 to 84% for Mn, 66 to 95.1% for Mo, and 30.1 to 82.3% for Zn resulting to a trend of Mo > Zn > Cu > Mn.

440A 강의 균일부식에 미치는 합금원소와 열처리의 영향(I) (The Effect of Alloying Elements and Heat Treatment on the Uniform Corrosion of 440A Martensitic Stainless Steel(I))

  • 김영철;강창룡;정병호
    • 동력기계공학회지
    • /
    • 제15권2호
    • /
    • pp.42-48
    • /
    • 2011
  • 440A martensitic stainless steels which were modified with reduced carbon content(~0.5%) and addition of small amount of nickel, vanadium, tungsten and molybdenum were manufactured. Effects of alloying elements and tempering temperatures on the uniform corrosion in the solution of lN H2S04 were investigated through the electrochemical polarization test. When tempering temperature is constant, corrosion current density in active-passive transition point, Icorr, decreased a little with an increase of austenitizing temperature. In addition to this, when austenitizing temperature is constant, longer holding time showed a little lower Icorr and Ipass, passive current density. And when austenitized at $1050^{\circ}C$ and tempered in a range of $350{\sim}750^{\circ}C$, best anti-corrosion properties were obtained at $350^{\circ}C$ tempering temperature while worst at $450^{\circ}C$ or $550^{\circ}C$. The specimens tempered at below $450^{\circ}C$ and above $550^{\circ}C$, similar and good anti-corrosion characteristics were obtained regardless of alloying elements added, showing anti-corrosion characteristics are influenced more by tempering temperature than by alloying elements.