• Title/Summary/Keyword: Molten mark

Search Result 14, Processing Time 0.026 seconds

A Study on the Ignition and Molten Mark Analysis of Ballast for Fluorescent Lamp (형광등용 안정기의 발화 및 용융흔 분석에 관한 연구)

  • 최충석;박창수;김혁수;김향곤;정재희
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1998.11a
    • /
    • pp.173-177
    • /
    • 1998
  • In this paper, we reported an outbreak of fire hazard of ballast for fluorescent lamp. The surface structure and composition of ballast coil analyzed by using metallurgical microscope, scanning electron microscope(SEM) and energy dispersive x-ray spectroscopy(EDX). The surface of molten mark appeared columnar structure and void. EDX analysis indicated that the molten mark spectra were composed not only of the corresponding original spectra but also of several new lines.

  • PDF

ANALYSIS OF EQUILIBRIUM METHODS FOR THE COMPUTATIONAL MODEL OF THE MARK-IV ELECTR OREFINER

  • Cumberland, Riley;Hoover, Robert;Phongikaroon, Supathorn;Yim, Man-Sung
    • Nuclear Engineering and Technology
    • /
    • v.43 no.6
    • /
    • pp.547-556
    • /
    • 2011
  • Two computational methods for determining equilibrium states for the Mark-IV electrorefiner (ER) have been assessed to improve the current computational electrorefiner model developed at University of Idaho. Both methods were validated against measured data to better understand their effects on the calculation of the equilibrium compositions in the ER. In addition, a sensitivity study was performed on the effect of specific unknown activity coefficients-including sodium in molten cadmium, zirconium in molten cadmium, and sodium chloride in molten LiCl-KCl. Both computational methods produced identical results, which stayed within the 95% confidence interval of the experimental data. Furthermore, sensitivity to unavailable activity coefficients was found to be low (a change in concentration of less than 3 ppm).

A Study on the Short Circuit Current and Molten Mark Analysis of Polyvinyl Chloride Insulated Flexible Cords (비닐코드의 단락전류 및 용융흔 분석에 관한 연구)

  • Choi, Chung-Seog;You, Sun-Hee;Yoo, Jae-Geun;Shong, Kil-Mok;Kim, Hyang-Kon;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1630-1632
    • /
    • 1999
  • In this paper, we studied the short circuit current and molten mark of polyvinyl chloride insulated flexible cords(VFF). The calory decreased remarkably with increase of current. The surface structure and composition of a strand wire were analyzed by stereoscope, scanning electron microscope (SEM), and energy dispersive x-ray spectroscopy(EDX). The surface of a strand wire showed columnar and void. The intensity of CuL spectrum increased in melted mark.

  • PDF

Cause Analysis Ignited at a Far Infrared Radiation Heater (원적외선 히터에서 출화된 화재의 원인분석)

  • Kim, Dong-Ook;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.91-96
    • /
    • 2008
  • This research studied about the cause analysis of fire that was occurred in far infrared rays heater to base on the fire examples. Fire of electric heater was apt to commit error that handled an over-heating accident by judged molten mark in heat ray. Molten mark which was attached in heat ray was appeared to the form of layer short circuit by other metal material, but other metal material was not found beside the ingredient of heat wire which was mixed to an alloy of Fe-Cr-Al according to result of ingredient distribution by SEM/EDX. Also, the result of overheating experiment by layer short circuit and overvoltage showed higher febrility than normal, but there was no possibility of fire occurrence. This paper will be contributed to science for cause analysis of electric fire through analyzing physical, chemical and flame features of burnout heater on the basis of diagnosis of fire that was happened in infrared rays heater.

Solidification of Hot-Dip Galvanized Layer by Electrostatically Charged Aerosol Particles (정전 대전된 액적에 의한 용융 아연 도금층의 응고 방법)

  • 김상헌;김형민;정원철;정원섭
    • Journal of Surface Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.233-240
    • /
    • 2000
  • A novel electrostatic spraying method to solidify molten zinc coating layer was studied by SEM and measurement of sample's temperature. The sprayed droplets also served as nucleation sites in the solidification reaction of molten zinc but might leave the pitting mark by impinging on its surface especially at high spray pressure. Our experimental results showed that electric field could change the sprayed particle trajectories and assist the fine droplets to attach on the surface. Thus, by reducing the spray pressure and by applying the electric voltage higher than -20 KV to charge the droplets electrostatically, we could produce the spangle free galvanized coating layer without pitting.

  • PDF

The Fire Dispersive Patterns of the Power Cord Sets for Low Voltage Appliances in Wall-modeling (벽면 모델링을 이용한 저압용 일체형 코드의 화재확산 패턴)

  • Shong, Kil-Mok;Kim, Hyang-Kon;Kim, Dong-Ook;Kim, Dong-Woo;Kim, Young-Seok;Choi, Chung-Seog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.330-334
    • /
    • 2004
  • In this paper, we studied on the fire dispersive patterns and the fire progress at the power cord sets for low voltage appliances in the wall-model. For the experiment, we manufactured a wall-model and applied the external flame at the power cord sets. From the results, short-circuit of the power cord sets was haunted by the external flame it was disconnected with the flashing and the scattering. The fire progress on the polyvinyl chloride insulated flexibel cords is not observed because the ignition energy decreases. In case of rubber insulated flexible cords, however, the fire was progressed continuously. Molten marks were formed at a two electric wire by continuous electric discharge in power source part. A large molten mark was formed in load part. And the columnar structure and voids were observed in molten wire.

  • PDF

The Properties of Waveform and Plug Formed by Poor Contact of Power Cord Sets (전원코드의 접촉 불량에 의해 형성된 파형 및 플러그의 특성)

  • Choi Chung-Seog;Kim Hyang-Kon;Kim Dong-Ook;Kim Young-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.1 s.69
    • /
    • pp.87-93
    • /
    • 2005
  • In this paper, we analyzed ignition characteristics of combustible material and the waveform of power dissipation, voltage and current by poor contact. And the surface structure of plug by poor contact was analyzed. In the results of experiment, the heat generated by poor contact and ignited the combustible material on power cord sets. The insulation material was molten and carbonized by the heat conduction though plug pit and voids were formed inside of insulation material. The waveform of voltage and power dissipation distorted because of a growth of oxidation by poor contact. In particular, in case that load was big load, the waveform of voltage and power dissipation severely distorted as with the passage of time. The surface of plug pin was changed from erosion mark to welding mark according to big load. The results will be applied to the cause analysis of electrical disaster.

CORIUM COOLABILITY UNDER EX-VESSEL ACCIDENT CONDITIONS FOR LWRs

  • Farmer, Mitchell T.;Kilsdonk, Dennis J.;Aeschlimann, Robert W.
    • Nuclear Engineering and Technology
    • /
    • v.41 no.5
    • /
    • pp.575-602
    • /
    • 2009
  • In the wake of the Three Mile Island accident, vigorous research efforts were initiated to acquire a basic knowledge of the progression and consequences of accidents that involve a substantial degree of core degradation and melting. The primary emphasis of this research was placed on containment integrity, with: i) hydrogen combustion-detonation, ii) steam explosion, iii) direct containment heating (DCH), and iv) melt attack on the BWR Mark-I containment shell identified as energetic processes that could lead to early containment failure (i.e., within the first 24 hours of the accident). Should the core melt fail the reactor vessel, then non-condensable gas production from Molten Core-Concrete Interaction (MCCI) was identified as a mechanism that could fail the containment by pressurization over the long term. One signification question that arose as part of this investigation was the effectiveness of water in terminating an MCCI by flooding the interacting masses from above, thereby quenching the molten core debris and rendering it permanently coolable. Successful quenching of the core melt would prevent basemat melt through, as well as continued containment pressurization by non-condensable gas production, and so the accident progression would be successfully terminated without release of radioactivity to the environment. Based on these potential merits, ex-vessel corium coolability has been the focus of extensive research over the last 20 years as a potential accident management strategy for current plants. In addition, outcomes from this research have impacted the accident management strategies for the Gen III+LWR plant designs that are currently being deployed around the world. This paper provides: i) an historical overview of corium coolability research, ii) summarizes the current status of research in this area, and iii) highlights trends in severe accident management strategies that have evolved based on the findings from this work.

Analysis of a Car Fire Case Caused by the Overheating of a Diesel Particulate Filter (매연포집필터 과열로 발생한 디젤승용차화재 원인의 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.89-97
    • /
    • 2017
  • This study analyzed the case of diesel car fires that occurred while driving in a tunnel 5 days after maintenance at a car service center. The results of the investigation and analysis found that a large amount of white foreign matter adhered to the inside of the exhaust port and the insulating plate above the DPF (diesel particulate filter) installed in the middle of the exhaust pipe was melted and lost. In particular, the metal floor of the car above the DPF was molten and pierced, and the rubber mat placed on the metal floor was burnt. Moreover, while the exhaust pipe in front of the DPF showed no overheating mark, such a mark was observed in the exhaust pipe from the DPF to the exhaust port. Because these findings may appear only when the DPF is overheated and ignited, this car fire is believed to have been caused by internal overheating of the DPF. The car fire investigation of this study suggests that if white foreign matter is found in the inside of the exhaust port during a fire cause investigation of a diesel car, the cause of the fire should be determined by removing the DPF and examining the internal damage of the DPF.