Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference (한국조명전기설비학회:학술대회논문집)
- 2004.05a
- /
- Pages.330-334
- /
- 2004
The Fire Dispersive Patterns of the Power Cord Sets for Low Voltage Appliances in Wall-modeling
벽면 모델링을 이용한 저압용 일체형 코드의 화재확산 패턴
- Shong, Kil-Mok ;
- Kim, Hyang-Kon ;
- Kim, Dong-Ook ;
- Kim, Dong-Woo ;
- Kim, Young-Seok ;
- Choi, Chung-Seog
- 송길목 (한국전기안전공사 부설 전기안전연구원) ;
- 김향곤 (한국전기안전공사 부설 전기안전연구원) ;
- 김동욱 (한국전기안전공사 부설 전기안전연구원) ;
- 김동우 (한국전기안전공사 부설 전기안전연구원) ;
- 김영석 (한국전기안전공사 부설 전기안전연구원) ;
- 최충석 (한국전기안전공사 부설 전기안전연구원)
- Published : 2004.05.07
Abstract
In this paper, we studied on the fire dispersive patterns and the fire progress at the power cord sets for low voltage appliances in the wall-model. For the experiment, we manufactured a wall-model and applied the external flame at the power cord sets. From the results, short-circuit of the power cord sets was haunted by the external flame it was disconnected with the flashing and the scattering. The fire progress on the polyvinyl chloride insulated flexibel cords is not observed because the ignition energy decreases. In case of rubber insulated flexible cords, however, the fire was progressed continuously. Molten marks were formed at a two electric wire by continuous electric discharge in power source part. A large molten mark was formed in load part. And the columnar structure and voids were observed in molten wire.
Keywords