• 제목/요약/키워드: Molar region

검색결과 285건 처리시간 0.032초

Determination of some useful radiation interaction parameters for waste foods

  • Akman, F.;Gecibesler, I.H.;Sayyed, M.I.;Tijani, S.A.;Tufekci, A.R.;Demirtas, I.
    • Nuclear Engineering and Technology
    • /
    • 제50권6호
    • /
    • pp.944-949
    • /
    • 2018
  • The mass attenuation coefficients (${\mu}/{\rho}$) of food waste samples (pomegranate peel, acorn cap, lemon peel, mandarin peel, pumpkin peel, grape peel, orange peel, pineapple peel, acorn peel and grape stalk) have been measured employing a Si(Li) detector at 13.92, 17.75, 20.78, 26.34 and 59.54 keV. Also, the theoretical values of the mass attenuation coefficients have been evaluated utilizing mixture rule from WinXCOM program. The results showed that the lemon peel has the highest values of ${\mu}/{\rho}$ among the selected samples. From the obtained mass attenuation coefficients, we determined some absorption parameters such as effective atomic number ($Z_{eff}$), electron density ($N_E$) and molar extinction coefficient (${\varepsilon}$). It was found that the $Z_{eff}$ values of all food wastes lie within the range of 4.034-7.595, whereas the $N_E$ of the studied food wastes was found to be in the range of $0.301-1.720{\times}10^{25}$ (electrons/g) for present energy region.

구치부 치관삭제가 생쥐 해마복합체에 미치는 영향에 관한 조직학적 연구 (Influence of Molarless Condition on the Hippocampal Formation in Mouse: a Histological Study)

  • 김용철;강동완
    • 구강회복응용과학지
    • /
    • 제23권2호
    • /
    • pp.179-186
    • /
    • 2007
  • The decrease of masticatory function caused by tooth loss leads to a decrease of cerebral blood flow volume resulting in impairment of cognitive function and learning memory disorder. However, the reduced mastication-mediated morphological alteration in the central nervous system (CNS) responsible for senile deficit of cognition, learning and memory has not been well documented. In this study, the effect of the loss of the molar teeth (molarless condition) on the hippocampal expression of glial fibrillary acidic protein (GFAP) protein was studied by immunohistochemical techniques. The results were as follows : 1. The molarless mice showed a lower density of pyramidal cells in the cornu ammonis 1 (CA1) and dentate gyrus (DG) region of the hippocampus than control mice. 2. Immunohistochemical analysis showed that the molarless condition enhanced the time-dependent increase in the cell density and hypertrophy of GFAP immunoreactivity in the CA1 region of the hippocampus. The molarless condition enhanced an time-dependent decrease in the number of neurons in the hippocampal formation and the time-dependent increase in the number and hypertrophy of GFAP-labeled cells in the same region. The data suggest a possible link between reduced mastication and histological changes in hippocampal formation that may be one risk factor for senile impairment of cognitive function and spatial learning memory.

하악에 발생한 과잉치의 치험례 (A CASE OF SUPERNUMERARY TEETH IN THE MANDIBULAR INCISOR REGION :)

  • 박정아;최남기;김선미;장희숙;양규호
    • 대한소아치과학회지
    • /
    • 제32권4호
    • /
    • pp.644-648
    • /
    • 2005
  • 과잉치는 정상치판(dental lamina)의 과도한 증식의 결과로 발생되어 가족적 성향을 보이며, 쇄골두개이형성(Cleidocranial dysplasia), Gardner 증후군 등의 여러 질환과 관련되어 나타나기도 한다. 그 빈도는 유치열에서 $0.3{\sim}0.8%$, 영구치열에서 $1.0{\sim}3.5%$이고, 남성에서 호발되며(2 : 1), 상악에서 더 많이 발생한다(9 : 1). 상악에서는 mesiodens라고 불리는 중절치 사이의 위치가 가장 흔한 부위이고, 그 다음은 fourth molar와 측절치 부위이다. 하악에서는 소구치 부위가 가장 흔한 부위이고 전치부위에서는 약 2%로 매우 드물게 발생한다. 과잉치의 만기 잔존은 치간 이개, 인접한 치아의 맹출 장애, 치근 흡수 등을 야기하고 과잉치와 관련되어 함치성 낭종이 발생될 수 있으므로 조기진단과 적절한 치료가 중요하다. 본 두 증례는 비교적 드물게 나타나는 하악에 발생한 과잉치로, 하악 전치부와 소구치부에 발생한 과잉치를 발거하고 교정치료를 시행하여 양호한 결과를 얻었기에 보고하는 바이다.

  • PDF

Association between dental implants in the posterior region and traumatic occlusion in the adjacent premolars: a long-term follow-up clinical and radiographic analysis

  • Lee, Jae-Hong;Kweon, Helen Hye-In;Choi, Seong-Ho;Kim, Young-Taek
    • Journal of Periodontal and Implant Science
    • /
    • 제46권6호
    • /
    • pp.396-404
    • /
    • 2016
  • Purpose: The aim of this retrospective study was to determine the association between dental implants in the posterior region and traumatic occlusion in the adjacent premolars, using data collected during from 2002 to 2015. Methods: Traumatic occlusion in the adjacent premolars was assessed by examining clinical parameters (bleeding on probing, probing pocket depth, fremitus, and tooth mobility) and radiographic parameters (loss of supporting bone and widening of the periodontal ligament space) over a mean follow-up of 5 years. Clinical factors (gender, age, implant type, maxillary or mandibular position, opposing teeth, and duration of functional loading) were evaluated statistically in order to characterize the relationship between implants in the posterior region and traumatic occlusion in the adjacent premolars. Results: The study inclusion criteria were met by 283 patients, who had received 347 implants in the posterior region. The incidence of traumatic occlusion in the adjacent premolars was significantly higher for splinted implants (P=0.004), implants in the maxillary region (P<0.001), and when implants were present in the opposing teeth (P<0.001). The other clinical factors of gender, age, and duration of functional loading were not significantly associated with traumatic occlusion. Conclusions: This study found that the risk of traumatic occlusion in the adjacent premolars increased when splinted implants were placed in the maxillary molar region and when the teeth opposing an implant also contained implants.

4성분 Li2O-B2O3-Al2O3-SiO2 유리들의 구조로부터 굴절률과 경도 연구 (Studies of Refractive Index and Hardness from the structures in Quarternary Li2O-B2O3-Al2O3-SiO2 Glasses)

  • 문성준
    • 한국안광학회지
    • /
    • 제7권2호
    • /
    • pp.27-31
    • /
    • 2002
  • 4성분 $Li_2O-B_2O_3-Al_2O_3-SiO_2$ 유리들을 $R({\equiv}Li_2Omole%/B_2O_3mole%)$$K({\equiv}(Al_2O_3mole%+SiO_2mole%/B_2O_3mole%)$에 의해 제작하여 유리들의 구조를 굴절률 (refractive index)과 Vicker's 경도(hardness)의 변화를 측정하여 분석하였다. 먼저, 굴절률의 증가는 유리 내부구조의 분극률을 증가시키는 $Li^+$ 양이온 수의 증가에 우선적으로 의존하여 증가하였으며, 적은 양의 리튬 산화물($Li_2O$)이 첨가된 영역에서는 굴절률은 리튬 이온 양에 의존하며, 많은 양의 리튬 산화물이 첨가된 영역에서는 큰 몰 부피를 갖고 하나의 비가교 산소를 갖는 $BO_3{^-}$ 단위들의 형성으로 유리 구조 내의 몰 부피 증가로 유리들의 굴절률의 증가가 둔화되었다. 그리고 알루미늄 산화물($Al_2O_3$)과 규소 산화물($SiO_2$)의 증가에 따라 굴절률의 감소는 $Al_2O_3$$SiO_2$에 의해 형성되어진 $AlO_4$ 단위들과 $SiO_4{^-}$ 단위들이 붕소 산화물($B_2O_3$)에 의해 형성되어진 $BO_4$단위들보다 몰 부피의 증가로 감소되어졌다. 또한, 경도의 증가는 유리 망목구조에 형성되어지는 $BO_4$ 단위 수에 의존하였으며, 경도의 감소는 유리 망목구조를 개방화시키는 $BO_3{^-}$ 단위 수에 의존하여 감소함을 알 수 있었다.

  • PDF

치조골 높이가 다른 임프란트 주위 지지골 응력분석 (Stress Analysis on the Supporting Bone around the Implant According to the Vertical Bone Level)

  • 부수붕;정제옥;이승훈;김창현;이승호
    • 구강회복응용과학지
    • /
    • 제23권1호
    • /
    • pp.55-68
    • /
    • 2007
  • The purpose of this study was to analyze the distribution of stress in the surrounding bone around implant placed in the first and second molar region. Two different three-dimensional finite element model were designed according to vertical bone level around fixture ($4.0mm{\times}11.5mm$) on the second molar region. A mandibular segment containing two implant-abutments and a two-unit bridge system was molded as a cancellous core surrounded by a 2mm cortical layer. The mesial and distal section planes of the model were not covered by cortical bone and were constrained in all directions at the nodes. Two vertical loads and oblique loads of 200 N were applied at the center of occlusal surface (load A) or at a position of 2mm apart buccally from the center (load B). Von-Mises stresses were analyzed in the supporting bone. The results were as follows; 1. With the vertical load at the center of occlusal surface, the stress pattern on the cortical and cancellous bones around the implant on model 1 and 2 was changed, while the stress pattern on the cancellous bone with oblique load was not. 2. With the vertical load at the center of occlusal surface, the maximum von-Mises stress appeared in the outer distal side of the cortical bone on Model 1 and 2, while the maximum von-Mises stress appeared in the distal and lingual distal side of the cortical bone with oblique load. 3. With the vertical load at a position of 2 mm apart buccally from the center, there was the distribution of stress on the upper portion of the implant-bone interface and the cortical bone except for the cancellous bone, while there was a distribution of stress on the cancellous bones at the apical and lingual sides around the fixture and on the cortical bone with oblique load. 4. With the changes of the supporting bone on the second molar area, the stress pattern on the upper part of the cortical bone between two implants was changed, while the stress pattern on the cancellous bone was not. The results of this study suggest that establishing the optimum occlusal contact considering the direction and position of the load from the standpoint of stress distribution of surrounding bone will be clinically useful.

한국 청년의 미소에 관한 연구 (A STUDY ON THE SMILE IN KOREAN YOUTH)

  • 윤민의;진태호;동진근
    • 대한치과보철학회지
    • /
    • 제30권2호
    • /
    • pp.259-271
    • /
    • 1992
  • This study was designed to investigate the criteria of the perfect smile that was necessary to improve the esthetic problem in oral and maxillo-facial region and treating the anterior tooth region. The author took the facial straight photograph of 240 university students(male : 129, female : 111) in a resting and a smiling position, measured and analized the lip pattern and the relation between the lip and the teeth when they were smiling. Besides, 10 members of committee for appraisal (dentist : 5 persons, professor of the college of fine arts : 5 persons) estimated the smiling pattern. After that the author have compared and analyzed the obtained results. The results obtained were as follows : 1. In the shape of the upper lip, when the upper lip curved downward, it was 42.92% , straight was 45.00% and curved upward was 12.08%. The group in which the upper lip curved upward was the most esthetic. 2. In the relation between the upper lip and the teeth, high smile was 29.17%, average smile was 55.83% and low smile was 15.00%. The group of average smile was the most esthetic. 3. In the parallel relation between the lower lip and maxillary anterior incisal curvature, the group of paralled was 60.42%, the group of straight was 34.17% and the group of reverse was 5.41%. The group of parallel was the most esthetic. 4. In the relationship between maxillary anterior incisor and lower lip, the group of the maxillary anterior incisor were slightly covered by the lower lip was 10.42%, the group of the maxillary anterior teeth touched to the lower lip was 35.83%, and the no-touching was 53.75%. The group of the maxillary anterior teeth touched to the lower lip was the most esthetic. 5. In the teeth displayed in a smile, displayed to the canine was 0.84%, displayed to the first premolar was 19.17%, displayed to the second premolar was 57.92%, displayed to the first molar was 20.00% and displayed to the second molar was 2.08%. The group of displayed to the first molar was the most esthetic. 6. At smiles, the width of the mouth corner was 0.46 times of the full face width, 0.95 times of the interpupillary distance, and 1.23 times of the resting position. 7. At smiles, the lengh of the upper lip was 0.71 times and lower lip was 0.93 times of the length in the resting position.

  • PDF

4성분 NaBAISi 유리계의 굴절률과 경도 연구 (Studies of Refractive Index and Hardness In Quarternary NaBAISi Glasses)

  • 문성준;황인선
    • 한국안광학회지
    • /
    • 제8권1호
    • /
    • pp.1-5
    • /
    • 2003
  • 4성분 $Na_2O-B_2O_3-Al_2O_3-SiO_2$ 유리들을 $R({\equiv}Na_2O\;mole%/B_2O_3\;mole%)$$K({\equiv}(Al_2O_3\;mole%+SiO_2\;mole%)/B_2O_3mole%)$에 의해 제작하여 유리들의 구조를 굴절률(refractive index)과 vicker's 경도(hardness)의 변화를 측정하여 분석하였다. 먼저, 굴절률의 증가는 유리 내부구조의 분극률을 증가시키는 $Na^+$ 양이온수의 증가에 우선적으로 의존하여 증가하였다. 적은 양의 소듐 산화물($Na_2O$) 이 첨가된 영역에서 굴절률은 소듐 이온 양에 의존하였으며, 많은 양의 소듐 산화물이 첨가된 영역에서는 큰 몰 부피를 갖고 하나의 비가교 산소를 갖는 $BO_3{^-}$ 단위들의 형성으로 유리 구조 내의몰 부피 증가로 유리들의 굴절률의 증가가 둔화되었다. 그리고 알루미늄 산화물($Al_2O_3$)과 규소 산화물($SiO_2$)의 증가에 따라 굴절률의 감소는 $Al_2O_3$$SiO_2$에 의해 형성되어진 $AlO_4$ 단위들과 $SiO_4{^-}$ 단위들이 붕소 산화물($B_2O_3$)에 의해 형성되어진 $BO_4$ 단위들보다 몰 부피의 증가로 감소되어졌다. 또한, 경도의 증가는 유리 망목구조에 형성되어지는 $BO_4$ 단위 수에 의존하였으며, 경도의 감소는 유리 망목구조를 개방화시키는 $BO_3{^-}$ 단위 수에 의존하여 감소함을 알 수 있었다.

  • PDF

하악 구치부에서 $Br{\aa}nemark$$TiUnite^{(R)}$ implant를 이용한 단일 치아수복의 후향적 연구 (A Retrospective study on $Br{\aa}nemark$ $TiUnite^{(R)}$ implant for mandibular posterior single tooth replacement)

  • 오경춘;채경준;정의원;김창성;조규성;최성호;김종관;채중규
    • Journal of Periodontal and Implant Science
    • /
    • 제37권4호
    • /
    • pp.705-718
    • /
    • 2007
  • The purpose of this study was to evaluate 6 years cumulative survival rate (CSR, %) of mandibular posterior single tooth implants replaced with $Br{\aa}nemark$ $TiUnite^{(R)}$ implant system. The findings from this study were as followed ; 1. The 112 (111 persons) single implants that were placed in the mandibular posterior region were successful except 4 cases and showed 96.42% CSR. 2. The 55 (55 persons) single implants that were placed in the mandibular first molar region were successful except 2 cases and showed 96.36% survival rate. And, among the 57 (56 persons) single implants replacing the mandibular second molar. 2. failed showing 96.49% survival rate. There was no significant statistical difference. 3. Among the total 112 implants, 5.0mm wide diameter implants were placed in 96 cases(85.7%) showing 96.9% survival rate. 4.0mm standard diameter implants were placed in 16 cases showing 93.8% survival rate. There was no significant statistical difference. 4. Long implants above 10.0mm length were placed 103 cases(91.0%) and showed 96.1% survival rate. Short implants within 8.5mm length were placed 9 cases and showed 100% survival rate. There was no significant statistical difference. 5. 37 implants placed in type I, II bone quality were showed higher survival rate(100%) than that of 52 implants placed in type III, IV bone quality(92.3%). But, there was no significant statistical difference. In conclusion, $Br{\aa}nemark$ $TiUnite^{(R)}$ implant showed successful results when replacing manbibular single molar.

하악의 교정용 미니 임플랜트 식립 부위에서의 피질골 두께와 치근간 거리: 3차원으로 재구성한 CT 영상을 이용한 연구 (Cortical bone thickness and root proximity at mandibular interradicular sites: implications for orthodontic mini-implant placement)

  • 임주은;임원희;전윤식
    • 대한치과교정학회지
    • /
    • 제38권6호
    • /
    • pp.397-406
    • /
    • 2008
  • 교정용 미니 임플랜트의 식립 부위에 대한 연구는 주로 구치부 치근사이 공간에 집중되어 왔다. 본 연구의 목적은 전치에서 구치에 이르는 치아간의 피질골 두께와 치근간 거리를 측정함으로써 교정용 미니 임플랜트 식립 시에 참고 할 수 있는 임상적 지침을 제공하는 것이다 연구를 위해 성인 28명(남자 14명, 여자 14명)의 CT를 V-works $4.0^{TM}$을 이용하여 3차원 영상으로 전환하였다. 중절치에서 제2대구치에 이르는 모든 치아 사이를 치간 접촉점을 지나면서 교합 평면에 수직이 되도록 잘라 $90^{\circ}$ 단면을 형성한 후 치조정으로부터 높이를 달리하여 0, 15, 30, $45^{\circ}$의 각도를 주어 피질골의 두께를 측정하였다. 또한 치조정으로부터 2, 4, 6 mm 높이에서 교합 평면에 평행하게 잘라 $90^{\circ}$ 단면을 만든 후 치근간 거리를 측정하였다. 피질골의 두께는 전 치부에서 구치부로 갈수록 두꺼워지는 경향을 보였으며, 5-6과 1-1 사이, 6-7과 1-1, 1-2, 2-3 사이에서는 유의한 차이를 보였다 (p < 0.05). 치조정으로부터 2 mm 높이를 제외한 대부분의 위치에서 각도가 증가함에 따라 피질골의 두께가 급격히 증가하는 경향을 보였고, 4 - 6 mm 높이에 식립시 $30-45^{\circ}$ 이상의 각도를 부여해야 피질골 보유량(engage 양)에 유의한 차이를 보였다. 치근간 거리 측정 결과 4-5, 5-6, 6-7 사이가 치근 손상 없이 미니 임플랜트를 식립하기에 적절한 위치라고 볼 수 있었고, 1-1과 1-2 사이는 미니 임플랜트 식립을 위한 충분한 치근간 거리를 제공하지 못하는 것으로 나타났다. 본 실험의 결과로 볼 때 피질골과 미니임플랜트의 접촉면을 증가시키기 위해서는 치조정에서 치근단부로 4와 6 mm 되는 부위에서 $30^{\circ}$ 또는 $45^{\circ}$로 식립하는 것이 유리할 것으로 보인다.