• Title/Summary/Keyword: Moire Method

Search Result 138, Processing Time 0.028 seconds

A Study on Elliptical Bulge Test by Moire Method (모아레법에 의한 타원벌지의 연구)

  • 백남주;강대민;한규택;지용주
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.4
    • /
    • pp.394-399
    • /
    • 1984
  • 본 연구에서는 Duncan과 Johnson의 사각 벌지에 관한 이론식을 재료의 성질 및 파괴 특성을 결정하는데 유용한 방법인 타원벌지에 응용하여 고찰 검토하였다. 또 실험에는 각 점에서 변형도를 광격자법(photo grid method)에 의해서 측정했다. 그리고 극점의 곡률반경을 모아레 측정법으로 타원벌지에 처음 적용하여 구해서 이를 이론치와 서로 비교 함으로서 실험적인 측정법의 유용성을 밝혔다.

Diagnosis of Work-related Musculoskeletal Disease through Moire Image Pattern and Treatment Measure using a Sling System (Moire' 영상무늬를 통한 근골격계질환의 진단과 현가장치를 이용한 치료방안)

  • Lee Sang-Yong;Lee Eun-Kyong;Kwon So-Hee;Jung He-Kyong;Kim Sam-Tae;Chong Myong-Soo;Lee Ki-Nam
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.7 no.2
    • /
    • pp.121-130
    • /
    • 2003
  • The Musculoskeletal Disease has been ignored or turned away due to the difficulty of diagnosis and the vagueness of judgement up to now. Contrary to other diseases, there were many cases where the character of the Musculoskeletal Disease wasn't revealed through the objective inspection. And that's because the Musculoskeletal Disease appears for the most part due to muscular defect so it is impossible to diagnose the muscle by X-ray diagnosing the bone and it is also impossible to diagnose the fine damage of the muscle or tendon even by advanced device like MRI. As the nervous blood vessels or acupunctures pass through or are next to the muscle, the tension of the muscle put pressure on these so can become the direct or indirect causes of various kinds of pains or intern diseases. But in spite of that, for lack of proper equipment diagnosing the state of the muscle(Shortened.. Relaxed... or Hardened...) the muscle has been disregarded or neglected intentionally or unintentionally. While many people think themselves to be a muscular expert, if they don't see the shape of the muscle, that is just like blind treatment. But as now the equipment diagnosing the state of the muscle is developed, it seems that this problem can be settled. It was attempted in this study that the muscle or skeleton of the Musculoskeletal disease patients was diagno the treatment order and method were decided by a questionnaire survey and simple inspection, and the Musculoskeletal correction exercise using the muscle management and sling system made them escape from the Musculoskeletal disease, turning their muscle into more flexible and stronger muscle. As a result notwithstanding the limited treatment period '12 times', the improvement rate was as high as 74%, which showed that the muscle management and Musculoskeletal correction exercise had a great effect on the symptom improvement of the patients. If the treatment times had increased, the improvement rate also would have increased more.

  • PDF

A Study on the Grating Projection Method using Polygon Mirror (회전다면경을 이용한 줄무늬 격자 영사방법에 관한 연구)

  • Park, Yoon-Chang;Jeong, Kyung-Min;Jang, Seok-Jun;Park, Kyung-Keun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.6
    • /
    • pp.159-165
    • /
    • 2001
  • Recently Moire and PMP(Phase Measuring Profilometry) are adopted as a practical methodology for non-contact 3-D measurement of free surface. These methods extract the 3-D informations from the images of the object projected with stripe-pattern light. This paper presents a simple projector generating stripe-pattern light using expensive polygon mirror. In this projector, slit-beam is generated with a Laser diode and a rod lens and the laser diode is switched on/off synchronizing with the rotation of the polygon mirror. So its structure is very simple and light-weighted compared to the existent projection methods using several lenses and it is also easy to change the pitch and the phase of the stripe pattern. Experimental results show that the intensity profile of the stripe pattern can be approximated with sinusoidal curve by reducing the pitch of the stripe pattern.

  • PDF

The Study on the Factors Related to the Existence of Neck Pain in Female Office Workers (사무직 여성 근로자의 경부 통증 유무와 관련된 요인 연구)

  • Nam, Ki-Bong;Chung, Seok-Hee;Kim, Sung-Su
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.19 no.2
    • /
    • pp.213-225
    • /
    • 2009
  • Objectives : The purpose of this study was to investigate the factors related on pain in female office workers. Methods : Neck pain group of 31 female subjects complained of neck and arm discomfort. Normal group of 20 female subjects had no complaints or minimal discomfort. Cervical curvature and muscle tone were assessed by whole spine x-ray, meridian-electromyography(MEMG), craniovertebral angle, and Moire. Neck pain was evaluated by Neck Disability Index(NDI) and Visual Analog Scale(VAS). The emotional and other physical factors that could effect neck pain were checked by questionnaires including Beck Depression Index(BDI), Stress Reaction Index(SRI), Holmes & Rahe Social Readjustment Rating Scale(SRRS), International Physical Activity Questionnaire(IPAQ), and Gastrointestinal Symptom Rating Scale(GSRS). Results : The contraction and fatigue of upper trapezius by MEMG was significantly higher in the neck pain group. And BDI, SRI, SRRS, and GSRS were significantly higher in the neck pain group (p<0.05). However, there was no significant difference in the Jackson's angle, Cobb's method, craniovertebral angle, and moire between two groups. Conclusions : The results suggest that neck pain is related to mental stress rather than physical stress and physical stress does not change cervical curvature significantly.

3D Precision Measurement of Scanning Moire Using Line Scan Camera (라인스캔 카메라를 이용한 3차원 정밀 측정)

  • Kim, Hyun-Ju;Yoon, Doo-Hyun;Kim, Hak-Il
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.5
    • /
    • pp.376-380
    • /
    • 2008
  • This paper presents the Projection Moire method using a line scan camera. The high resolution feature of a line scan camera makes it possible to scan an image quickly, thus enabling a much quicker 3D profile. This method uses a high resolution line scan camera making it possible to scan an image at high speed simultaneously measuring the 3D profile of a large FOV. When using a high resolution scan camera, a full FOV is scanned, thus requiring just one movement of a projection grating. As a result, the number of grating movements is reduced drastically. The end result is a faster and more accurate 3D measurement. Moving the grating too quickly causes vibration in the imaging system, which will normally be required to apply a stitching technique when using an area scan camera. However the technique is not required when using a line scan camera. Compared with the previous techniques, it has the advantages of simple hardware without moving mechanical parts - single exposure for obtaining three-dimensional information. A method using a high resolution line scan camera can be used in mass production to measure the bump height of wafers or the bump height of package substrates.

A Study on the Extrusion of Anisotropic Materials with the Method of Moire Frinfe Analysis (모아레법에 의한 이방성재료의 압출에 관한 연구)

  • Huh, Hoon;Kim, Dong-Won
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.1 no.3
    • /
    • pp.164-170
    • /
    • 1977
  • Johnson 의 직교이방성재료압출시의 slip line 해를 모아레법으로 검토하였다. 모아레식편상에 slipline 장과 유사한 모아레무늬를 얻어 이론해와 비교하였으며, 모아레무늬 해석법으로 변형후의 상당스트레인 속도분포를 구하였다.

밀링가공에서 이미지 프로세싱을 이용한 다인공구의 파손검출기법 개발(ㅣ)

  • 사승윤;최영규;김영일;홍윤석;유봉환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.04b
    • /
    • pp.92-96
    • /
    • 1993
  • Modern NC machine tools require a more and more exact monitoring and control of cutting process. A very important parameter is tool wear used to optimize cutting data and to change tools at the right time. In this study, a real-time multi-tool fracture method is proposed for measuring crater from fringe patterns generated by uni-shadow-moire. An optical technique using laser for non-contact measurement of tool fracture is presented. The technology in which the tool is illuminated by a beam of He-Ne laser and then the image of tool fracture CCD camera.

A New Smoothing Method for Moire Patterns in Color Inverse Halftoning (칼라 역 해프토닝에서 새로운 모아레 패턴 평활화 방법)

  • 한영미;김민환;김종민
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2001.11a
    • /
    • pp.153-158
    • /
    • 2001
  • 본 논문에서는 해프톤 패턴의 간섭현상으로 발생하는 모아레 패턴을 효과적으로 제거할 수 있는 새로운 모아레 패턴 평활화 방법을 제시한다. 제안한 방법에서는 모아레 패턴이 존재하는 영역에 대해서만 그 세기에 따라 평활화 정도를 적극적으로 조정해 주기 때문에, 모아레 패턴을 효과적으로 제거하면서 경계나 텍스쳐 같은 의미있는 고주파 성분도 잘 보존할 수 있다. 또한 기존의 방법과 달리 퓨리에 변환과 같은 추가 연산을 필요로 하지 않고 미리 만들어진 테이블을 참조하는 과정만으로 모아레 피크의 세기를 결정하기 때문에 연산 시간 측면에 서로 효율적이다. 제안한 방법은 칼라 인쇄물을 다루는 다양한 멀티미디어 분야에서 유용하게 활용될 수 있다.

  • PDF

A surface area measurement techniques for the human head and face (두상의 표면적 측정 방안)

  • 이근부
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1996.04a
    • /
    • pp.655-657
    • /
    • 1996
  • In this study, the methods and equipment that can be used to detail the anthropomorphic data were developed. This new method that utilizes the Moire' interferometry and image processing technique is less expensive than the conventional methods. We took 36 subjects (18 years to 28 years old). The face area was calculated based on contour information. The cluster analysis about those data enables us to classify our subjects into four groups.

  • PDF

Anthropometry of Surface Area (인체의 표면적 측정)

  • 이근부
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.18 no.36
    • /
    • pp.41-47
    • /
    • 1995
  • This study present a systematic and more economical anthropometric technique to acquire 3-D anthropometric data by the use of moire interferometry, image processing and computer vision techniques. An experiment was performed to measure in anthopometric variables (head and face), such as head length, head breath, length of ear to top of head, contained face areas, etc. We took fourty-five subjects with wide range of ages(18 years to 33 years old). The face area was calculated based on contour information. The results were then compared with plaster bandage methods. It turned out that the proposed method had 90.85% consistancy.

  • PDF