• Title/Summary/Keyword: Moire Method

Search Result 138, Processing Time 0.025 seconds

A Study on the Improvement of Accuracy of Shape Measurement in the Shadow Moire Method (그림자식 모아레를 이용한 형상측정법의 정확도 개선에 관한 연구)

  • 박경근;박윤창;정경민
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.175-180
    • /
    • 1999
  • Generally, When we measure of object 3D surfaces with phase shifting shadow moire method, it is use of optical system consist of light source, grating, and ccd camera. At this time, it is important parameter that vertical distance of grating and camera, grating and light source, and horizontal distance of camera and light source. When use camera consist of complex lens vertical distance of grating and camera is unknown parameter. From this cause equivalent wave length of moire fringe is uncertain. In this study, We exactly obtain a vertical distance of grating and camera so improve on measurement accuracy.

  • PDF

Vibration Analysis and Design of CRT for Reduction of Moire Phenomena (CRT 모아레 현상의 억제를 위한 진동 해석 및 설계)

  • 이규헌;유홍희
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.413-418
    • /
    • 2001
  • The moire phenomena, which are induced by mask vibration due to the excitation of speakers, degrades the color purity of CRT. So it is important to eliminate this phenomena to obtain a good CRT design. In this study we analyze the mask vibration by experiment as well as finite element method. To obtain the finite element solutions efficiently, an equivalent model was employed. The experimental and analysis results show reasonable agreements. An enhanced design configuration of mask welding points are suggested through this study.

  • PDF

Correlation between Cutometer and Quantitative Evaluation Using Moire Topography in Age-related Skin Elasticity (Morie Topography를 이용한 피부 탄력 평가와 Cutometer 결과와의 상관성 연구)

  • Ahn, Sung-Yeon;Bae, Ji-Hyun;Kim, Seung-Hun;Lee, Hae-Kwang;Moon, Seong-Joon;Chang, Ih-Seop;Lee, Ok-Sub
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.31 no.4 s.54
    • /
    • pp.343-347
    • /
    • 2005
  • As aging occurs, ow skin gets more wrinkles, becomes drier and loses its elasticity. Validating the evaluation of skin elasticity is especially important, because it is not as visible as other signs of aging such as wrinkles. Here, we identified the correlation between age and the Parameters given by Cutometer, and (we present) the parameters of that reflect the decreases in skin elasticity along with ages (Ur/Uf, Ua/Uf, Ur/Ue, Ua, $r=0.687{\sim}0.725$). Also we developed an evaluation method to quantify the difference of skin by viewing or touching. A five-grade standard of Moire topographic photo scale on face was prepared using sensory evaluation of 20 to 61 year - old women. Based on this photo standard, scoring was performed using (a) 5-grade system by three specialists to obtain the consensus score. Significant negative correlations between age and results of Cutometer $(r=-0.687{\sim}-0.725)$, Moire topography scores (r=-938) were found. Finally we have shown the significance of the correlation between the result of Cutometer and the score of Moire topography (r=0.711). Our studies using Moire topography on face have confirmed that instrumental measurements reflect the decrease in shin elasticity, which is perceived visually.

Fringe Sensitivity of Projection Moire Topography Due to Position of Light Source and Object Distance According to Grating Periods (영사식 무아레 토포그래피에서 격자 주기에 따른 물체거리와 광원의 위치에 대한 무늬 민감도 변화)

  • Oh, Hyun Seock;Ju, Yun Jae;Jo, Jae Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.27 no.2
    • /
    • pp.67-72
    • /
    • 2016
  • In projection moire topography, the investigation of fringe sensitivity, which means the change rate of fringe order according to object height, is important and necessary to reduce the measurement error of the shape of an object. Using the fringe sensitivity, the determination of the absolute orders of moire fringes can be performed very easily and rapidly. The important parameters in the determination of absolute orders of fringes are the positions of light source and object, and the grating period in projection moire topography. Among these parameters, the fringe sensitivity due to the transverse motion of the light source and the longitudinal motion of the object according to grating periods are analyzed and compared. As a result, whereas the fringe sensitivity in the transverse-motion method increases linearly and gradually as the distance between light source and imaging sensor increases, the fringe sensitivity due to the longitudinal-motion method decreases dramatically as the distance between imaging lens and object increases. In these methods, the fringe sensitivity and its change increase as the grating period increases.

Tow-dimensional Strain Analysis by Fourier Transform Moire Interferometry (Fourier 변환 모아레 간섭에 의한 이차원적 변형률 해석)

  • Park, T.W.;Shimada, T.;Morimoto, Y.;Han, E.K.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.12 no.1
    • /
    • pp.16-24
    • /
    • 1992
  • Moire interferometry using a diffraction grating and a laser is a powerful technique for analizing small deformation of a specimen. In the method, the x and y-directional fringe patterns are obtained by using the x and y-directional sets of two beams. If the both sets of two beams are simultaneously incident to the specimen, the x and y-directional fringe patterns are super imposed. In this case, it is difficult to separate each directional fringe pattern. Therefore each fringe pattern has been separately recorded by selecting each set of two beams. In order to analyze a two-dimensional strain changing with time, Moire interferometry using the two-dimensional fourier transform method is proposed and the x and y-directional fringes are separated. By this method, the thermal deformation of a glass plate is analyzed.

  • PDF

Improvement of Accuracy in Moire-type Laser Encoder Using Four Point Method (4점법을 이용한 모아레식 레이저 엔코우더의 정밀 정확도 향상)

  • Jeon, Byeong Wook;Park, Too Won;Lee, Myung Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.7
    • /
    • pp.19-25
    • /
    • 1995
  • Presently, along with the advance of high-technology, the precise measurement of linear displacement has become a staple requirement, and consequently the high resolution with submicron order has also been required in precise positioning and carriaging. In this paper, we advance a propose on a new type of laser encoder based on the principle of phase analysis of the moire fringes from superimposed two gratings. The phase angle as an information of displacement can be accurately calculated by detecting the change in brighness at four points of the fringes. The actual application of four point method to the moire fringes is performed thru microcomputer for general purpose, and the measuring procedure is also studied in this research. As an experimental result, in the case of using 20 .mu. m-pitch gratings, it is validated that this method has the resolution of 0.01 .mu. m and the accuracy of .+-. 0.15 .mu. m over the setting range of 100mm.

  • PDF

Determination of stress intensity factors of bent and eccentric cracks by multi-point selection method (다점선정법에 의한 편심 및 굴절균열의 응력확대계수의 결정)

  • 김종주;서인보;최선호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.5
    • /
    • pp.1079-1086
    • /
    • 1990
  • Recently, demand for the experimental analysis of crack, such as arbitrary or distributed ones which has been considered quite difficult to investigate by the theoretical and numerical method, is increasing. Among existent experimental methods applied to the analysis of stress intensity factors, the slab analogy method have the following merits; cracks can be replaced by similarity-shaped rigid body, and the distribution of stress is represented by slab curvature of duly bent specimen. For the accuracy improvement of this method, multi-point selection method was introduced and its accuracy proved by applying this method to the analysis of centrally linear and inclined cracks in a finite plate which are theoretically known. In this paper, moreover, the stress intensity factors of eccentric and skew-symmetric bent cracks were determined by multi-point selection method and newly developed moire tilted master grating method. The results obtained by this method showed good agreement with the reliably theoretical solutions.

A Morphological Study On The Upper Face Of Moire According To The Sasang Constitution (사상체질별(四象體質別) 상안부(上顔部) Moire 형태(形態)의 특징(特徵)에 관한 연구(硏究))

  • Hong, Suck-chull;Lee, Eui-ju;Lee, Su-kyung;Han, Gi-hwan;Kho, Byung-hee;Song, Il-byung
    • Journal of Sasang Constitutional Medicine
    • /
    • v.10 no.2
    • /
    • pp.271-281
    • /
    • 1998
  • 1. Objective : This research is a study about constitutional diagnosis through the external appearances, especialy it is for finding shape differences of the upper-face pictures of moire, according to the Sasang constitution 2. Method : We have collected 98 cases of femail patients of the Sasang Constitutional Department, including employees of the Kyung-Hee Medical Center and took pictures of moire of upper face and measured 50 points. We analyzed shape differences of the upper face according to the Sasang constitution. 3. Results : Analysing the moire of upper face, the characteristics according to sasang constitution presented. 4. Conclusion : Soyangin had a projected part of left upper face compared with taeumin. With the image of moire, the characteristics of upper face according to sasang constitution was found.

  • PDF