• 제목/요약/키워드: Module Plants

검색결과 151건 처리시간 0.039초

태양전지모듈 고장 진단 알고리즘을 적용한 모니터링시스템 (The Monitoring System with PV Module-level Fault Diagnosis Algorithm)

  • 고석환;소정훈;황혜미;주영철;송형준;신우균;강기환;최정내;강인철
    • 한국태양에너지학회 논문집
    • /
    • 제38권3호
    • /
    • pp.21-28
    • /
    • 2018
  • The objects of PV (Photovoltaic) monitoring system is to reduce the loss of system and operation and maintenance costs. In case of PV plants with configured of centralized inverter type, only 1 PV module might be caused a large loss in the PV plant. For this reason, the monitoring technology of PV module-level that find out the location of the fault module and reduce the system losses is interested. In this paper, a fault diagnosis algorithm are proposed using thermal and electrical characteristics of PV modules under failure. In addition, the monitoring system applied with proposed algorithm was constructed. The wireless sensor using LoRa chip was designed to be able to connect with IoT device in the future. The characteristics of PV module by shading is not failure but it is treated as a temporary failure. In the monitoring system, it is possible to diagnose whether or not failure of bypass diode inside the junction box. The fault diagnosis algorithm are developed on considering a situation such as communication error of wireless sensor and empirical performance evaluation are currently conducting.

복합플랜트 지하 건설을 위한 파이프랙 모듈 공법 안정 해석 (Stability Analysis of Pipe Rack Module for Underground Complex Plants Construction)

  • 김세원;이상준;김영석
    • 한국지반신소재학회논문집
    • /
    • 제20권4호
    • /
    • pp.113-124
    • /
    • 2021
  • 도시화 및 경제성장에 따라 기존 매립지 등 기피 시설로 인식되어 있는 지상 환경기초시설 및 에너지생산 시설의 지하화가 중요한 사회적 이슈로 대두되고 있다. 대규모 플랜트 시설을 지하에 안전하게 건설하기 위해서는 제한적인 공간 레이아웃의 활용성을 높이고, 불필요한 기둥을 최소화해야 한다. 본 논문에서는 플랜트 시설을 지하화 할 경우 발생하는 작업의 제약여건, 조립 및 철거, 공정 계통의 연계성, 유지 보수 등의 문제를 해결하기 위하여 플랜트 모듈화 공법(파이프랙)에 대해 검토하였다. 복합플랜트의 지하 고집적 배치, 공간 레이아웃 활용성 향상 및 구조물 안정성 확보를 위해 다양한 하중조건(지진하중, 장치하중, 토압하중 등)을 적용한 플랜트 모듈 해석을 수행하였다. 또한, 작용하중과 부재가 견딜 수 있는 설계강도비 값을 검토하고 모듈 형상에 따른 안정성을 고려한 파이프랙 소재를 추출하였다. 다양한 경계조건에서의 해석 결과를 바탕으로 지하복합플랜트 건설 시 필요한 기본모듈의 최소 설치 간격 및 모듈 배치(안)에 관한 시사점을 도출하였다.

염전 병행 태양광 발전의 실증과 시뮬레이션 (Salt Farm Parallel Solar Power System:Field tests and Simulations)

  • 박종성;김봉석;김근호;이승민;임철현
    • Current Photovoltaic Research
    • /
    • 제7권4호
    • /
    • pp.121-124
    • /
    • 2019
  • In this research, the concept of a salt farm parallel solar power system, which produce salt and electricity at the same site, is proposed for the first time in the world. The concept is that large waterproof plates made by interconnected solar modules are installed at the bottom of the salt farm. The pilot system was successfully installed at a sea shore, and verified its feasibility as a solar power plant. For deeper understanding, simulations for power prediction of the system were carried out and compared with the field test results. The power generation of the salt farm parallel system is comparable to conventional solar power plants. The cooling effect by sea water contributes more to the increase in the crystalline silicon photovoltaic module performance than the absorption loss due to sea water by maintaining certain height above the module.

ANALYSIS OF ENVIRONMENTAL CHARACTERISTICS IN URBAN-TYPE PLANT FACTORY

  • J. E. Son;Park, J. S.;Lee, H.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.III
    • /
    • pp.744-748
    • /
    • 2000
  • The characteristics of $CO_2$ exchange between plant and human modules, absorption rate of NO$_2$, and growth of lettuce were examined in an urban-type plant factory(UPF). With 150 lettuce plants, $CO_2$ concentrations of plant module were 600 ~ 700$\mu$mol mol$^{-1}$ at average leaf weight of 130g.plant$^{-1}$ and 900~1100$\mu$mol.mol$^{-1}$ at 75g.plant$^{-1}$ for one and two persons' stay in the human module, respectively. When the air of 0.13, 0.30 and 0.45 $\mu$molㆍmol$^{-1}$ NO$_2$ in a human module was circulated ON/OFF 10/20min between the human and plant modules, $NO_2$ decrement in the chamber during 10 min was 0.040, 0.109, and 0.149 $\mu$mol, respectively. The lettuces grown at 0.45 $\mu$molㆍmol$^{-1}$ $NO_2$ during experimental period showed no significant differences in growth factors such as leaf width, leaf length, leaf area and fresh weigh, and in the quality between treated and control.

  • PDF

화학플랜트 고온고압부 설계 효율화를 위한 일관시스템 구축 (Development of Integrated Design System for High Temperature, High Pressure Parts for Chemical Plants)

  • 정동관
    • 한국가스학회지
    • /
    • 제2권4호
    • /
    • pp.1-6
    • /
    • 1998
  • 중화학 플랜트의 고온고압 요소인 증기 발생기(steam generator)의 드럼, 헤더 및 헤더 스터브 설계에 응력해석에서 부터 도면자동작도, 제작용 서류 자동생성에 이르기까지의 제반설계과정을 체계적으로 연결시킨 설계정보 통합 관리로 단순 설계오류를 줄이고, 또한 설계변경에 대해 신속한 재설계가 가능한 효율적인 설계를 도모하기 위하여 "피로수명을 고려한 헤더스터브 형상설계 모듈", "TRD301을 기초로한 후육내압부 운전조건(기동/정지 조건) 및 수명평가 모듈", "헤더 및 드럼부 자동작도 모듈"을 개발하였다. 이에 따라 형상설계 모듈을 이용하여 설계된 스터브 형상을 토대로 수명평가 모듈로 수명을 평가한 후 상세설계 도면 및 관련 서류의 자동작도로 이어지는 일관된 종합설계 시스템을 구축하였다.

  • PDF

메쉬 여과모듈을 이용한 잉여슬러지 농축 (Thickening of Excess Sludge using Mesh Filter)

  • 정용준;키소 요시아키;민경석
    • 한국물환경학회지
    • /
    • 제20권4호
    • /
    • pp.346-351
    • /
    • 2004
  • Because of being produced a great deal of excess sludges from biological wastewater treatment process, the subject regarding treatment and disposal of them has been significantly handled in real plants. It should be considered the alternative treatment with easy operating and cost effective process in rural areas. For the thickening of wasted activated sludge from small scale wastewater treatment facilities, thus, the provisional sludge thickening system was developed by the application of mesh filter module. Three meshes with different pore size(100, 150, $200{\mu}m$) were prepared for filter modules that were used to withdraw effluent from thickening system. A filter module with $100{\mu}m$ mesh was chosen as the most effective thickening material in the viewpoint of volume reduction and effluent quality: the volume reductions of initially injected sludge with 3,600 mg/L and 9,100 mg/L were 95% and 85%, respectively, and the filtered effluents were enough good to be shown below 1.0 mg/L of SS and 1.0 NTU of turbidity. Since the filtration of thickening was influenced by the cake layer formed on mesh filter module and this system was operated in the combination of sludge thickening with gravity settling, the filter modules with smaller pore size and the larger floc size were required for long term operation safely.

디지털보호계전기를 이용한 기중차단기 제어 및 모니터링 (Control And Monitoring Of Air Circuit Breaker Using Digital Protective Relay)

  • 이성환;박상배;안인석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.240-242
    • /
    • 2001
  • On this research, to catch up with international trend on the power system utilities move to be digitalized and move to network is certainly technological on the global business world, to compete with advanced foreign countries in the range of transmit and distribute power system and to take possession of first market share within country, we talked over a monitoring system to diagnose, monitor ACB(Air Circuit Breaker) only which is operated on the low level voltage Power plant. AMS(ACB Monitoring System) have be configured with several modules such as engine module which acquire engineering data from HICM360/860(Communication Control Units) and analyze and save it, database module which restore data and can be inquired, system monitoring view module which reflects fields information within a second, realtime trend window, historical trend window, reports as daily and yearly. In a near future, AMS must upgrade GUI to have easy to handle and have to have a field test to fit on real plants, so it will have faith in system reliability as it can apply power plant monitoring system in wide.

  • PDF

Development of field programmable gate array-based encryption module to mitigate man-in-the-middle attack for nuclear power plant data communication network

  • Elakrat, Mohamed Abdallah;Jung, Jae Cheon
    • Nuclear Engineering and Technology
    • /
    • 제50권5호
    • /
    • pp.780-787
    • /
    • 2018
  • This article presents a security module based on a field programmable gate array (FPGA) to mitigate man-in-the-middle cyber attacks. Nowadays, the FPGA is considered to be the state of the art in nuclear power plants I&C systems due to its flexibility, reconfigurability, and maintainability of the FPGA technology; it also provides acceptable solutions for embedded computing applications that require cybersecurity. The proposed FPGA-based security module is developed to mitigate information-gathering attacks, which can be made by gaining physical access to the network, e.g., a man-in-the-middle attack, using a cryptographic process to ensure data confidentiality and integrity and prevent injecting malware or malicious data into the critical digital assets of a nuclear power plant data communication system. A model-based system engineering approach is applied. System requirements analysis and enhanced function flow block diagrams are created and simulated using CORE9 to compare the performance of the current and developed systems. Hardware description language code for encryption and serial communication is developed using Vivado Design Suite 2017.2 as a programming tool to run the system synthesis and implementation for performance simulation and design verification. Simple windows are developed using Java for physical testing and communication between a personal computer and the FPGA.

Identification and functional analysis of COLD-signaling-related genes in Panax ginseng

  • Jeongeui Hong;Hojin Ryu
    • Journal of Plant Biotechnology
    • /
    • 제50권
    • /
    • pp.225-231
    • /
    • 2023
  • Cold stress is one of the most vulnerable environmental stresses that affect plant growth and crop yields. With the recent advancements in genetic approaches using Arabidopsis and other model systems, genes involved in cold-stress response have been identified and the key cold signaling factors have been characterized. Exposure to low-temperature stress triggers the activation of a set of genes known as cold regulatory (COR) genes. This activation process plays a crucial role in enhancing the resistance of plants to cold and freezing stress. The inducer of the C-repeatbinding factor (CBF) expression 1-CBF module (ICE1-CBF module) is a key cold signaling pathway regulator that enhances the expression of downstream COR genes; however, this signaling module in Panax ginseng remains elusive. Here, we identified cold-signaling-related genes, PgCBF1, PgCBF3, and PgICE1 and conducted functional genomic analysis with a heterologous system. We confirmed that the overexpression of cold- PgCBF3 in the cbf1/2/3 triple Arabidopsis mutant compensated for the cold stress-induced deficiency of COR15A and salt-stress tolerance. In addition, nuclearlocalized PgICE1 has evolutionarily conserved phosphorylation sites that are modulated by brassinsteroid insensitive 2 (PgBIN2) and sucrose non-fermenting 1 (SNF1)-related protein kinase 3 (PgSnRK3), with which it physically interacted in a yeast two-hybrid assay. Overall, our data reveal that the regulators identified in our study, PgICE1 and PgCBFs, are evolutionarily conserved in the P. ginseng genome and are functionally involved in cold and abiotic stress responses.

A Mobile Robot for Nuclear Power Plant Applications

  • Kim, Chang-Hoi;Seo, Yong-Chil;Cho, Jai-Wan;Choi, Young-Soo;Kim, Seung-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.803-807
    • /
    • 2003
  • Tele-operation and remote monitoring techniques are essential and important technologies for performing the inspection and repair tasks effectively in nuclear power plants. This paper presents the application of a mobile robot for the remote monitoring and inspection of the Calandria faces, where human access is limited because of the high-level radioactive environments during full power operation. The mobile robot was designed with reconfigurable crawler type of wheels attached on the front and rear side in order to pass through the ditch. The extendable mast, mounted on the mobile robot, can be extended up to 8 m vertically. This robot was also equipped a visible CCD/thermal infrared inspection head module and a stereo camera module for the enhancement of visual inspection.

  • PDF