• 제목/요약/키워드: Modulation energy

검색결과 471건 처리시간 0.038초

IMPLICATION OF STELLAR PROPER MOTION OBSERVATIONS ON RADIO EMISSION OF SAGITTARIUS A

  • CHANG HEON-YOUNG;CHOI CHUL-SUNG
    • 천문학회지
    • /
    • 제36권3호
    • /
    • pp.81-87
    • /
    • 2003
  • It is suggested that a flying-by star in a hot accretion disk may cool the hot accretion disk by the Comptonization of the stellar emission. Such a stellar cooling can be observed in the radio frequency regime since synchrotron luminosity depends strongly on the electron temperature of the accretion flow. If a bright star orbiting around the supermassive black hole cools the hot disk, one should expect a quasi-periodic modulation in radio, or even possible an anti-correlation of luminosities in radio and X-rays. Recently, the unprecedentedly accurate infrared imaging of the Sagittarius A$\ast$ for about ten years enables us to resolve stars around it and thus determine orbital parameters of the currently closest star S2. We explore the possibility of using such kind of observation to distinguish two quite different physical models for the central engine of the Sagittarius A$\ast$, that is, a hot accretion disk model and a jet model. We have attempted to estimate the observables using the observed parameters of the star S2. The relative difference in the electron temperature is a few parts of a thousand at the epoch when the star S2 is near at the pericenter. The relative radio luminosity difference with and without the stellar cooling is also small of order $10^{-4}$, particularly even when the star S2 is near at the pericenter. On the basis of our findings we tentatively conclude that even the currently closest pass of the star S2 is insufficiently close enough to meaningfully constrain the nature of the Sagittarius A$\ast$ and distinguish two competing models. This implies that even though Bower et al. (2002)have found no periodic radio flux variations in their data set from 1981 to 1998, which is naturally expected from the presence of a hot disk, a hot disk model cannot be conclusively ruled out. This is simply because the energy bands they have studied are too high to observe the effect of the star S2 even if it indeed interacts with the hot disk. In other words, even if there is a hot accretion disk the star like S2 has imprints in the frequency range at v $\le$ 100 MHz.

이득스위칭을 이용한 650nm InGaAIP FP LD의 광펄스 파라메터 분석 및 CW 발진과의 특성비교 (Optical pulse parameter analysis of gain switched InGaAIP FP LD at 650 nm wavelegth and its characteristic in comparison with CW operation)

  • 오광환;채정혜;이용탁;백운출;김덕영
    • 한국광학회지
    • /
    • 제12권2호
    • /
    • pp.135-142
    • /
    • 2001
  • 최근 플라스틱 광섬유(Plastic Optical Fiber, POF)가 홈 네트워크(Home Network) 및 LAN(Local Area Network)의 새로운 통신채널로 등장하였다. 특히 PMMA 계에 기반을 둔 언덕형 굴절률 분포 플라스틱 광섬유(Graded Index Plastic Optical Feiber)는 500nm와 650nm 근처에서 아주 적은 손실을 가지므로 이 파장영역에서의 광원으로서 극초단 광펄스 생성이 요구되고 있다. 본 연구에서는 650nm InGaAIP FP(fabry perot) LD와 간단한 RF(radio frequency)소자들을 이용한 회로를 구성하고 이득스위칭 기술을 사용하여 1GHz의 펄스 반복율을 가지고 33.3psec 정도의 짧은 반치선폭(FWHM)을 가지는 광펄스를 생성시키는데 성공하였다. 이득스위칭 된 광펄스는 주입되는 직류전류(DC bias current)와 변조되는 주파에 따라 반치선폭은 33.3-82.8 psec, 펄스 에너지는 0.97-9.69pJ의 값을 얻었다. 또한 CW 발진과 이득스위칭 된 광펄스의 스펙트럼 폭은 각각 0.44nm, 150nm로 됨을 측정하였다. 이러한 결과를 가지는 연속적인 광펄스는 직류전류와 VCO에 의한 변조주파수의 적절한 선택에 따라 초고속 근거리 광통신분야 뿐만 아니라 여러 가지 초고속 광소자 및 전자소자의 특성평가 등에 응용될수 있을 것으로 예상된다.

  • PDF

고전압 β-산화갈륨(β-Ga2O3) 전력 MOSFETs (High Voltage β-Ga2O3 Power Metal-Oxide-Semiconductor Field-Effect Transistors)

  • 문재경;조규준;장우진;이형석;배성범;김정진;성호근
    • 한국전기전자재료학회논문지
    • /
    • 제32권3호
    • /
    • pp.201-206
    • /
    • 2019
  • This report constitutes the first demonstration in Korea of single-crystal lateral gallium oxide ($Ga_2O_3$) as a metal-oxide-semiconductor field-effect-transistor (MOSFET), with a breakdown voltage in excess of 480 V. A Si-doped channel layer was grown on a Fe-doped semi-insulating ${\beta}-Ga_2O_3$ (010) substrate by molecular beam epitaxy. The single-crystal substrate was grown by the edge-defined film-fed growth method and wafered to a size of $10{\times}15mm^2$. Although we fabricated several types of power devices using the same process, we only report the characterization of a finger-type MOSFET with a gate length ($L_g$) of $2{\mu}m$ and a gate-drain spacing ($L_{gd}$) of $5{\mu}m$. The MOSFET showed a favorable drain current modulation according to the gate voltage swing. A complete drain current pinch-off feature was also obtained for $V_{gs}<-6V$, and the three-terminal off-state breakdown voltage was over 482 V in a $L_{gd}=5{\mu}m$ device measured in Fluorinert ambient at $V_{gs}=-10V$. A low drain leakage current of 4.7 nA at the off-state led to a high on/off drain current ratio of approximately $5.3{\times}10^5$. These device characteristics indicate the promising potential of $Ga_2O_3$-based electrical devices for next-generation high-power device applications, such as electrical autonomous vehicles, railroads, photovoltaics, renewable energy, and industry.

Impact of Photon-Counting Detector Computed Tomography on Image Quality and Radiation Dose in Patients With Multiple Myeloma

  • Alexander Rau;Jakob Neubauer;Laetitia Taleb;Thomas Stein;Till Schuermann;Stephan Rau;Sebastian Faby;Sina Wenger;Monika Engelhardt;Fabian Bamberg;Jakob Weiss
    • Korean Journal of Radiology
    • /
    • 제24권10호
    • /
    • pp.1006-1016
    • /
    • 2023
  • Objective: Computed tomography (CT) is an established method for the diagnosis, staging, and treatment of multiple myeloma. Here, we investigated the potential of photon-counting detector computed tomography (PCD-CT) in terms of image quality, diagnostic confidence, and radiation dose compared with energy-integrating detector CT (EID-CT). Materials and Methods: In this prospective study, patients with known multiple myeloma underwent clinically indicated whole-body PCD-CT. The image quality of PCD-CT was assessed qualitatively by three independent radiologists for overall image quality, edge sharpness, image noise, lesion conspicuity, and diagnostic confidence using a 5-point Likert scale (5 = excellent), and quantitatively for signal homogeneity using the coefficient of variation (CV) of Hounsfield Units (HU) values and modulation transfer function (MTF) via the full width at half maximum (FWHM) in the frequency space. The results were compared with those of the current clinical standard EID-CT protocols as controls. Additionally, the radiation dose (CTDIvol) was determined. Results: We enrolled 35 patients with multiple myeloma (mean age 69.8 ± 9.1 years; 18 [51%] males). Qualitative image analysis revealed superior scores (median [interquartile range]) for PCD-CT regarding overall image quality (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), edge sharpness (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), image noise (4.0 [4.0-4.0] vs. 3.0 [3.0-4.0]), lesion conspicuity (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), and diagnostic confidence (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]) compared with EID-CT (P ≤ 0.004). In quantitative image analyses, PCD-CT compared with EID-CT revealed a substantially lower FWHM (2.89 vs. 25.68 cy/pixel) and a significantly more homogeneous signal (mean CV ± standard deviation [SD], 0.99 ± 0.65 vs. 1.66 ± 0.5; P < 0.001) at a significantly lower radiation dose (mean CTDIvol ± SD, 3.33 ± 0.82 vs. 7.19 ± 3.57 mGy; P < 0.001). Conclusion: Whole-body PCD-CT provides significantly higher subjective and objective image quality at significantly reduced radiation doses than the current clinical standard EID-CT protocols, along with readily available multi-spectral data, facilitating the potential for further advanced post-processing.

장기간 SPOT/VEGETATION 정규화 식생지수를 이용한 지면 변화 탐지 개선에 관한 연구 (The Study of Land Surface Change Detection Using Long-Term SPOT/VEGETATION)

  • 염종민;한경수;김인환
    • 한국지리정보학회지
    • /
    • 제13권4호
    • /
    • pp.111-124
    • /
    • 2010
  • 지표면의 환경변화를 관측하는 것은 토지사용과 기후변화, 기상연구, 농업, 지표면의 에너지 균형 및 환경시스템에 매우 중요한 연구로 이용되어지고 있다. 최근 위성영상을 이용한 변화탐지는 국지 단위 환경변화 탐지를 위해 그 필요성이 높아지고 있는 실정이며, 특히 잦은 개발과 변화로 주기적인 탐지가 필요한 도심지역의 변화탐지는 국토환경변화 및 지역계획 연구에 대한 효율적인 의사결정 지원이 가능하므로 그 활용성이 매우 높아지고 있다. 이러한 배경으로, 위성 영상을 이용한 원격탐사 자료를 활용한 분석은 비교적 짧은 시간에 광범위한 지역의 영상 정보를 취득할 수 있기 때문에 국토 환경변화 관리 분야에서의 적용 가능성이 높다. 본 연구에서는 인공위성 자료를 활용하여 변화탐지를 수행할 때 공간정보 추출의 정확성을 높이는 기술 개발을 위해 시계열자료의 통계적 분석을 통한 변화탐지기법 개발을 수행하였다. 전처리된 자료를 이용하여 정규화 식생지수를 산출하고 K-mean clustering 무감독 분류를 통해 처리된 데이터를 연구영역의 10년간 자료를 이용한 평균 정규화 식생지수 값과 표준편차 값을 계산하여 각각의 화소별 상대적인 변화량을 측정하여 변화 정도를 탐지하였다. 일반적으로 변화 탐지 수행 시, 태양광 채널을 이용할 경우 기하학적 특성에 의해 발생하는 방향성 효과를 보정하여야 한다. 본 연구에서는 대기 보정과 방향성 보정이 수행된 중 저해상도 정규화 식생지수를 이용하여 객관적인 변화 임계치 값을 결정하였다. 연구결과 반사도 값의 차이를 이용한 변화탐지보다 객관적이고 명확하게 변화지역을 탐지할 수 있었다.

ADHD아동의 감각자극에 대한 생리학적 반응 특성과 행동학적 특성: 체계적 고찰 (The Physiological Responses and Behavior Characteristics of Sensory Stimulation of ADHD Children: A Systematic Review)

  • 이나핼;김경미
    • 대한감각통합치료학회지
    • /
    • 제9권2호
    • /
    • pp.51-60
    • /
    • 2011
  • 목적 : ADHD아동의 감각자극에 대한 생리학적 반응특성은 감각자극의 종류, 측정도구, 그리고 반응으로 알아보고, 행동학적 특성은 측정도구, 빈도, 측정도구별로 공통된 문제 항목을 분석하여 ADHD아동의 감각자극에 대한 특성을 알아보고자 하였다. 연구방법 : 체계적 고찰방법을 사용하였다. 1990년 1월부터 2011년 12월 31일까지 학회지에 게재된 논문을 Riss4U, MEDLINE/PubMed, CINAH을 통해 검색하였다. 주요 검색어는 "ADHD, Children, Sensory processing, sensory integration, SP, SSP, SOR, TIE, CSP, SEP, EDR"으로 하였으며, 최종적으로 15개의 논문을 분석하였다. 결과 : 1. ADHD아동을 대상으로 감각자극에 대한 생리학적 반응에 관한 연구는 5개(33.33%)이고, 행동학적 반응에 관한 연구는 10개(66.67%)이며, 두 가지를 병행한 연구는 2개(13.33%)로 전체 15개(100%)논문을 분석하였다. 2. 생리학적 반응에 관한 연구 5개 중, 촉각과 고유 감각 자극을 사용한 연구는 3개, 후각, 청각, 시각, 촉각, 전정감각을 모두 사용한 연구는 2개였다. 3. 행동학적 특성에 관한 연구 10 중, SP는 5개, SSP는 3개, SOR은 2개, TIE는 1개, CSP는 1개이다. 4. ADHD아동의 감각자극에 대한 생리학적 반응특성은 일차감각피질의 손 영역에 있는 신경원세포의 활동전위에서 큰 반응을 보였다. 반응 시 초기에 큰 반응을 보였고 뒤로 갈수록 빠른 습관화를 보이는 것으로 나타났고, 회복 시에 많은 비 특이적 반응을 보였다. 5. 행동학적 반응특성은 부주의/산만, 전정감각처리, 지구력/근 긴장도 조절, 감정반응에 대한 감각입력 조절, 활력이 부족하고 허약함을 보이는 특성이 있었다. 결론 : ADHD아동의 감각자극에 대한 생리학적 반응 특성과 행동학적 특성을 아는 것은 ADHD아동의 감각조절 문제를 이해하는데 중요한 근거가 된다.

  • PDF

생쥐 배아 줄기세포의 Buforin 2 및 pEP-1에 결합된 EGFP의 세포 내 수송 (Mouse Embryonic Stem Cell Uptakes of Buforin 2 and pEP-1 Conjugated with EGFP)

  • 정수현;박성순;임현정;전용필
    • 한국발생생물학회지:발생과생식
    • /
    • 제11권2호
    • /
    • pp.111-119
    • /
    • 2007
  • 배아줄기세포는 외부 기인 특정 요소를 이용한 세포 조절물질 활성을 통하여 원하는 세포형태로 분화될 수 있다. 배아줄기세포의 이용성세포침투성단백질(CPP)은 몇 개의 아미노산으로 구성된 작은 펩타이드로 유용한 물질 수송계 중의 하나로 인식되고 있다. 본 연구에서는 몇 종류의 CPP를 이용하여 특정 단백질을 생쥐배아줄기세포(R1)내로 트렌스펙션하는데 있어 그 정도를 결정할 수 있는 요소들의 영향을 분석하였다. CPP인 Buforin II, pEP-1을 강도를 강화한 녹색형광단백질(EGFP)에 부착되도록 하여 살아있는 세포에서 볼 수 있도록 하였다. 다양한 시간대별로 그리고 다양한 농도로 재조합 CPP-EGPF를 생쥐 배아줄기세포에 처리하였으며, 대조군으로 사용한 EGFP는 CPP를 갖고 있지 않았다. 재조합 CPP-EGFP들이 R1 배아줄기세포에 미치는 세포독성은 CPP 종류와 재조합 CPP-EGFP 농도에 의존적이었다. CPP-EGFP가 배아줄기세포의 세포질이나 핵질로 들어간 증거는 처리 후 30분 이내에서는 찾을 수 없었다. 1시간 후, pEP-1-EGFP-N을 처리한 일부 세포에서만 형광단백질이 세포안으로 들어간 것을 발견할 수 있었다. 처리를 24시간까지 하였으나 흥미롭게도 세포안으로 들어가는 정도와는 비례관계가 없었다. 또한, 배아줄기세포의 막을 통과할 수 있는 CPP의 경우, 처리 농도는 세포막을 침투하여 세포내로 이동하는 것과 비례적 관계는 없으나, 매우 높은 농도에서 약간 증가하는 경향을 보였다. 요약하면, CPP-EGFP의 트렌스펙션 효과는 전적으로 CPP에 의존적이며, CPP에 따라서는 His tag의 위치 또한 트렌스펙션에 영향을 줄 수 있으며, 처리시간은 CPP를 이용하여 배아줄기세포내로 단백질을 수송하는데 있어 중요 변수가 아니다. 또한, CPP-EGFP의 농도는 배아줄기세포막을 가로질러 수송되는데 큰 영향을 주지 않았다. 앞으로의 연구에서, 이들 CPP의 변형 또는 매개자 개발을 통한 배아줄기세포에서 좋은 단백질성 매개 수송자를 만드는 것이 필요하며 이를 이용한 분화 유도는 매우 유용할 것으로 사료된다.

  • PDF

국립암센터의 양성자 치료를 위한 수동형 다엽 콜리메이터 개발 (Development of Manual Multi-Leaf Collimator for Proton Therapy in National Cancer Center)

  • 이누리;김태윤;강동윤;최재혁;정종휘;신동호;임영경;박정훈;김태현;이세병
    • 한국의학물리학회지:의학물리
    • /
    • 제26권4호
    • /
    • pp.250-257
    • /
    • 2015
  • 양성자 치료를 위해서는 Snout이 부착된 받침대(gantry)를 사용하는데 빔의 형태를 만들기 위해 환자 종양의 크기와 거리에 맞게 황동 차폐체(aperture)가 많이 사용된다. 또한 빔의 거리를 보정하기 위해 PMMA를 이용한 거리 보상체도 사용된다. 이렇게 황동으로 만들어진 차폐체의 경우 가공하는데 많은 시간이 소요되며 비용 발생이 높다. 또한 치료 사용되었던 차폐체의 방사선 노출에 따라 재사용이 어렵다. 이러한 단점을 보안하기 위해 황동 차폐체 대신 X-선 치료에서 사용되는 수동형 다엽 콜리메이터 시스템을 도입하였다. 수동형 다업 콜리메이터는 여러 개의 황동판을 조립하여 차폐체를 제작하는 방식이다. 본 연구는 제작된 수동형 다엽 콜리메이터의 방사화 실험 및 필름을 이용해 선량측정을 진행하였다. 다엽 콜리메이터를 투과한 2차 발생 선량 1% 이하였으며, 여러 번의 230 MeV의 빔에서도 방사화가 2시간 이내에서 감소하였다. 이렇게 개발된 수동형 다엽 콜리메이터를 임상에 적용하여 일반 차폐체와 수동형 다엽 콜리메이터를 감마지표 분석을 했을 시 99.74%의 높은 일치도가 측정되었다. 또한, 일반 황동 차폐체에 비해 수동형 다엽 콜리메이터를 제작하는데 소요되는 비용과 시간을 1/10 이상 단축시킬 수 있다. 개발된 수동형 다엽 콜리메이터는 성공적으로 양성자 환자치료에 사용하고 있다.

자생식물 혼합 추출물이 SD 흰쥐에서의 행동양상 및 항산화 체계에 미치는 영향 (Effect of Natural Plant Mixtures on Behavioral Profiles and Antioxidants Status in SD Rats)

  • 서보영;김민정;김현수;박해룡;이승철;박은주
    • 한국식품영양과학회지
    • /
    • 제40권9호
    • /
    • pp.1208-1214
    • /
    • 2011
  • 주간졸음증은 업무수행 능력을 감소시키고 사고의 위험을 증가시키는 것으로 보고되어 있으며, 특히 교통사고의 주요 원인이 된다. 카페인은 전 세계적으로 가장 널리 이용되는 커피, 녹차, 콜라 등의 음료에 함유되어 있는 물질로써 정신적 스트레스를 완화시키고, 자살충동 및 우울증의 감소 등 특정 효과가 있는 것으로 보고된바 있으며 졸음을 억제하기 위한 수단으로 주로 이용된다. 그러나 산소 소모의 증가, 체내 에너지 손실 및 대사율 증가뿐 아니라 비장의 DNA 합성 감소, 체내 지질 산화 등의 많은 부작용을 가진다. 따라서 본 연구에서는 국화, 민들레, 두릅, 냉이, 석창포, 과라나 등의 자생식물들을 이용하여 행동학적 분석을 통한 각성 효과뿐만 아니라 인체의 생리활성에 안전한 물질을 탐색하고자 하였다. Open field test의 결과, 단회 투여 시 대조군에 비해 카페인 투여군에서 활동적인 행동 양상을 나타내었으며 NP군에서 카페인 투여군과 같은 수준의 활동 정도를 나타내었다. 또한 3주간 NP의 투여는 카페인의 투여에 비해 증가한 활동성의 결과를 보였다. 총콜레스테롤과 중성지방, LDL-콜레스테롤 농도의 경우 각 군 간의 유의적 차이가 나타나지 않았으며 HDL-콜레스테롤 농도의 경우 대조군에 비해 카페인군과 NP군에서 유의적 차이는 없었으나 카페인 투여군에 비해 NP 투여군에서 유의적으로 높은 수준을 보였다. 혈중 지질과산화 농도는 대조군(5.6 mM)에 비해 카페인군(11.7 mM)에서 유의적으로 높은 농도를 나타낸데 반해 NP군(6.4 mM)은 대조군과 같은 수준을 나타내었다. 간세포의 DNA 손상정도에서는 대조군($18.4{\pm}2.1$)에 비해 카페인 투여군($23.8{\pm}3.1$) 에서 유의적으로 손상이 증가한데 반해 NP군($15.9{\pm}1.7$)은 대조군에 비해 유의적 차이를 보이지 않음으로써 NP의 장기 투여는 DNA 손상에 아무런 영향을 주지 않았다. 본 연구의 결과, 국화, 민들레, 두릅, 냉이, 석창포, 과라나 등의 자생식물 혼합추출물이 카페인과 비슷한 각성효과를 보이면서도 장기복용 시 안전한 것으로 나타나 각성효능이 있는 기능성식품으로서의 가능성이 충분하다고 사료된다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF