• 제목/요약/키워드: Modulation Index

검색결과 389건 처리시간 0.022초

Novel Architecture for Efficient Implementation of Dimmable VPPM in VLC Lightings

  • Jeong, Jin-Doo;Lim, Sang-Kyu;Jang, Il-Soon;Kim, Myung-Soon;Kang, Tae-Gyu;Chong, Jong-Wha
    • ETRI Journal
    • /
    • 제36권6호
    • /
    • pp.905-912
    • /
    • 2014
  • In this paper, a new architecture is proposed to achieve complexity efficiency in implementing variable pulse position modulation (VPPM). VPPM, specified in IEEE 802.15.7, can support wireless communication and dimming control simultaneously using visible light. The proposed architecture is based on the VPPM signal property in which the transition point of the modulated output is obtained by counting the sample index and comparing it to both the assigned dimming factor and the transmitting data. Therefore, the proposed architecture can be composed of simple logics, including a counter, a comparator, and an inverter, all of which are insensitive to the dimming resolution in contrast to a conventional codeword-table method. This paper describes the verification of the proposed algorithm through a register-transfer level implementation of the codeword and proposed architectures. In comparison with the codeword-table method, the proposed method gains a nine-fold complexity reduction at a 1% dimming-step resolution.

부분대역 재밍하에서 리미터-변별기 검파와 Integrate-and-Dump 펄터링을 고려한시스템의 성능 분석 (Analyzed the performances for system withlimiter discriminator detection and integrate and dump post detection filtering)

  • 이봉수;이사원
    • 한국컴퓨터정보학회논문지
    • /
    • 제3권4호
    • /
    • pp.78-85
    • /
    • 1998
  • 본 논문에서는 열잡음과 부분대역 재밍하에서 리미터-변별기 검파와 Integrate - and - Dump 필터링을 고려한 FH/CPFSK시스템의 성능을 분석하였고, 시스템을 평가하는데 있어서 인접한 8개의 Bit 패턴에 대한 심볼간 간섭과 차분위상, FM잡음 클릭을 고려하였다. 그 결과, 최적의 변조지수 h는 0.7이었고, 대역폭과 시간의 곱 D는 1.0이었으며, 부분대역 재밍하에서 열잡음을 고려했을 때, 대략 20dB 이하에서는 시스템의 오류확률에 중대한영향을 미쳤으나 20dB 이상에서는 무시할 수 있었다.

  • PDF

가우스성 잡음과 임펄스성 잡음이 혼재하는 다중전파 페이딩 전송로상에서의 제반 디지털 통신 시스템 특성의 종합분석 및 비교에 관한 연구(제 1 부) (Comprehensive Performance Analysis and Comparison of various Digital Communication Systems in an Multipath Fading Channel with additive Mixture of Gaussian and Impulsive Noise [Part-1])

  • 김현철;고봉진;공병옥;조성준
    • 한국통신학회논문지
    • /
    • 제14권3호
    • /
    • pp.263-279
    • /
    • 1989
  • 본 논문의 제 1 부에서는 대표적인 제반 디지털 통신시스템, 즉, 진폭변조(ASK), 직교진폭변조(QAM), 동기위상변조(CPSK), 차동위상변조(DPSK), 주파수변조(FSK), 및 최소편이 주파수변조(MSK) 시스템이 가우으성 잡음과 임펄스성 잡음이 존재하는 채널 환경하에서 신호가 영향을 받았을 때의 오율에 관한 식을 유도하여 반송파 전력대 잡음전력비(CNR), 임펄스지수 및 임펄스성 잡음전력에 대한 가우스성 잡음전력비를 함수로 하여 시스템의 성능을 구했다. 각 시스템의 열화 특성을 그래프로 나타내어 임펄스성 잡음이 가우스성 잡음보다 시스템의 성능을 얼마나 더 열화시키는가를 알 수 있게 했다.

  • PDF

아토피피부염에 대한 천일염(天日鹽)과 청기해독산(淸肌解毒散)의 병용 투여 효과 (Combinational Treatment of Oral Chenggihaedok-san and Topical Solar salt on Atopic Dermatitis)

  • 안황용;김동희
    • 동의생리병리학회지
    • /
    • 제23권6호
    • /
    • pp.1431-1443
    • /
    • 2009
  • In order to investigate the therapeutic effect of SSC, NC/Nga animal model resembling the AD-like symptoms were used to measure the changes in cytokines and histology. SSC prescription group showed significant decrease in the atopic dermatitis clinical index by 40.2% compared to that of the control. The SSC prescription had significant effect on immune cells that are related to inducing AD symptoms. SSC prescription also increased the ratio of immune cells in DLN that were not directly involved in AD symptoms. SSC prescription group showed significant decrease in the level of cytokines within spleen cells and DLN. The prescription also decreased the level of immunoglobulin IgE levels in serum by 25.3%. The thickness of epidermis and dermis as well as the precipitation of erythrocytes were also observed. The results indicate the therapeutic effect of SSC in the treatment of atopic dermatitis through immune modulation. The study will provide a broader applications in the treatment of atopic dermatitis. Particularly, skin regeneration effect and supplemental use of topical application of SS in atopic dermatitis treatment had been reported previously, and further investigation on the dose dependent effect as well as skin irritation studies of SS should be followed.

스텝 펄스파를 사용하는 캐스케이드 인버터에서 스위치의 간단한 도통각 계산법 (A Simple Method for Conducting Angle Calculation of Switching Devices in Cascaded Inverters Using Step Pulse Waves)

  • 김형창;김태진;강대욱;현동석
    • 전력전자학회논문지
    • /
    • 제8권6호
    • /
    • pp.488-495
    • /
    • 2003
  • 최근에 높은 전력과 전압의 적용을 위한 방법으로써 PWM 방법보다는 스텝 펄스파를 이용해 출력 전압 레벨을 조합하는 멀티레벨 인버터가 폭 넓게 사용되어지고 있다. 이 방식은 도통각을 통해 한주기에 한번만 온, 오프 하기 때문에 스위칭 손실 측면에서 유리한 특성을 갖는다. 본 논문에서는 도통각을 얻는 간단한 방법을 제안하며 이 방법은 출력 전압 레벨에 의해 나누어진 기준 전압 파형의 전압-시간 면적들을 통해 인버터의 출력 스텝 펄스파를 구성한다. 또한 제안한 방법은 근사법에 의한 연립방정식의 해를 구할 필요가 없기 때문에 기존의 방법과는 달리 계산량을 줄일 수 있고 온 라인에 의해 도통각을 얻을 수 있는 장점이 있다.

멀티 레벨 인버터에서 멀티 캐리어 PWM 방법을 사용한 고조파 분석의 새로운 방법 (A Novel Method of the Harmonic Analysis by Using the Multi-Carrier PWM Techniques in the Multi-Level Inverter)

  • 김준성;김태진;강대욱;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 추계학술대회 논문집
    • /
    • pp.171-174
    • /
    • 2002
  • This paper deals with a novel method in order to analyze the harmonic characteristics in the multi-level inverter. Generally, the magnitude of harmonic components is different according to the carrier PWM techniques, modulation Index(Mi), and the level of multi-level inverter The previous papers analyzed the harmonic characteristics from the viewpoint of the space vector. Hence, the calculation of the harmonic vector becomes difficult and complex in 4-level or more than S-level. However, the proposed method of this paper reduced an amount of calculation and simplified the process of calculation by using the relationship between reference voltage and output phase voltage to load neutral. This paper analyzed the harmonic and it is applied to the multi-carrier PWM techniques in 5- level and other-level of cascaded inverter system.

  • PDF

전류형 GTO 컨버터의 SHE-PWM 실시간제어기법 (On-line Techniques of SHE-PWN for Current Source GTO Converter)

  • 최재호;팽성일;채경훈
    • 전력전자학회논문지
    • /
    • 제4권6호
    • /
    • pp.523-530
    • /
    • 1999
  • 본 논문은 전류형 GTO 컨버터의 SHE-PWN 실시간 제어기법을 제안한다. 제안된 방법은 변조지수에 따라서 실시간으로 GTO 스위치의 턴-온/오프 주기를 계산할 수 있도록 Loop-up Table을 선형화 하였다. 제안된 방법에 의해서 컨버터의 DC 출력전류를 빠르고 연속적으로 제어하면서 컨버터의 AC 입력전류 파형을 정현파로 유지하고 동시에 역률을 ‘1’로 제어할 수 있다. 본 논문에서 SHE-P주 선형화 기법과 고 역률 제어기법을 제안하고 이들 성능을 해석적으로 검토하였다. 시뮬레이션과 실험 결과로부터 제안된 기법의 타당성을 입증하였다.

  • PDF

비구면 Glass렌즈 성형에 미치는 서냉조건 의존성 (Dependence of Annealing Condition on Aspheric Glass Lens Molding)

  • 차두환;안준형;김혜정;김정호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.469-470
    • /
    • 2006
  • The purpose of this research was to investigate and to find out the optimal annealing condition to mold an aspheric glass to be used for mobile phone module having 2 megapixel and $2.5{\times}$ zoom. Taking annealing rate and re-press temperature after molding as molding variables under the identical molding temperature and pressure, a glass lens was molded. And, Form Accuracy, Lens Thickness, Refractive Index, and Modulation Transfer Function(MTF) were measured in order to observe characteristics of molded lens, and then optimal annealing conditions were determined based on the resulting data. Properties of lens molded under the optimal conditions revealed Form Accuracy[PV] $0.2047\;{\mu}m$ in aspheric surface, and $0.2229\;{\mu}m$ in plane, and MTF value was 30.3 % under 80 lp/mm.

  • PDF

태양광 발전시스템을 위한 단상 PWM 전압형 인버터 (A Single-phase PWM Voltage Source Inverter for Photovoltaic Generation System)

  • 유택빈;성낙규;강승욱;이승환;이훈구;한경희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.443-445
    • /
    • 1995
  • Since the residential load is an AC load, while the output of solar cell is a DC power, the photovoltaic system needs the DC/AC converter to utilize solar cell and must provide the sinusoidal wave current and voltage with unity power factor in the case of driving to Interact with utility line. It is always necessary for the output of solar cell to operate in the vicinity of maximum power point, since it is greatly fluctuated by insolation. This paper treats that we will constitute a single phase PWM voltage source inverter and trace the modulation index which always maximize the output of solar cell in propotion to insolation variation and prove it by simulation that we can provide current wave, which is nearly sinusoidal wave with unity power factor, for load and utility line.

  • PDF

Two Modified Z-Source Inverter Topologies - Solutions to Start-Up Dc-Link Voltage Overshoot and Source Current Ripple

  • Bharatkumar, Dave Heema;Singh, Dheerendra;Bansal, Hari Om
    • Journal of Power Electronics
    • /
    • 제19권6호
    • /
    • pp.1351-1365
    • /
    • 2019
  • This paper proposes two modified Z-source inverter topologies, namely an embedded L-Z-source inverter (EL-ZSI) and a coupled inductor L-Z source inverter (CL-ZSI). The proposed topologies offer a high voltage gain with a reduced passive component count and reduction in source current ripple when compared to conventional ZSI topologies. Additionally, they prevent overshoot in the dc-link voltage by suppressing heavy inrush currents. This feature reduces the transition time to reach the peak value of the dc-link voltage, and reduces the risk of component failure and overrating due to the inrush current. EL-ZSI and CL-ZSI possess all of the inherent advantages of the conventional L-ZSI topology while eliminating its drawbacks. To verify the effectiveness of the proposed topologies, MATLAB/Simulink models and scaled down laboratory prototypes were constructed. Experiments were performed at a low shoot through duty ratio of 0.1 and a modulation index as high as 0.9 to obtain a peak dc-link voltage of 53 V. This paper demonstrates the superiority of the proposed topologies over conventional ZSI topologies through a detailed comparative analysis. Moreover, experimental results verify that the proposed topologies would be advantageous for renewable energy source applications since they provide voltage gain enhancement, inrush current, dc-link voltage overshoot suppression and a reduction of the peak to peak source current ripple.