• Title/Summary/Keyword: Modified glassy carbon electrode

Search Result 73, Processing Time 0.024 seconds

Quantitative Analysis of Ergosterol as a Biomarker of Mold-contaminated Foods Using the Enzyme Biosensor (효소 바이오센서를 이용한 식품의 곰팡이 오염 지표물질인 Ergosterol 정량분석)

  • Kim, Mi-Kyeong;Kim, Jong-Won;Kim, Mee-Ra
    • Korean journal of food and cookery science
    • /
    • v.25 no.2
    • /
    • pp.252-259
    • /
    • 2009
  • Ergosterol is the significant component of the cell wall of fungi. Its presence is regarded as evidence of fungi contamination in grain and other foods. Many studies on ergosterol detection have been carried out using chemical methods, but those methods required complicated pre-treatments and long analysis times. In this study, an amperometric biosensor was developed for fast and precise ergosterol detection. The biosensor system used the electron transfer of hydrogen peroxide produced from the reaction of ergosterol with cholesterol oxidase. The biosensor system consisted of a peristaltic pump, a syringe loading sample injector, an enzyme reactor, a fabricated flow-through cell containing a working electrode, a reference electrode and a counter electrode, and a potentiostat/recorder. The working electrode was prepared by coating modified multi-wall carbon nanotube (MWNT) on glassy carbon electrode. The $MWNT-NH_2$ coated glassy carbon electrode linearly responded to hydrogen peroxide in the range of $1{\times}10^{-5}{\sim}8{\times}10^{-5}$ M with a detection limit of $10^{-7}$ M in the basic performance test. The currents produced from the ergosterol biosensor showed the linearity in a range from $1.0{\times}10^{-6}$ M to $1.0{\times}10^{-5}$ M ergosterol.

The Modified Electrode by PEDOP with MWCNTs-Palladium Nanoparticles for the Determination of hydroquinone and Catechol

  • Naranchimeg, Orogzodmaa;Kim, Seul-Ki;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.8
    • /
    • pp.2771-2775
    • /
    • 2011
  • Poly-ethylenedioxypyrrole (PEDOP) coated thiolated multiwall carbon nanotubes palladium nanoparticles (MWCNTs-Pd) modified glassy carbon electrode (GCE) [PEDOP/MWCNTs-Pd/GCE] for the determination of hydroquinone (HQ) and it’s isomer catechol (CA) were synthesized and compared with bare GCE and thiolated multiwall carbon nanotubes (MWCNTs-SH/GCE). The modification could be made by simple processes on a GCE with MWCNTs-Pd covered by PEDOP in a 0.05 M tetrabutylammonium perchlorate (TBAP)/MeCN solution system. A well-defined peak potential evaluation of the oxidation of hydroquinone to quinone at 0.05 V (vs. Ag/AgCl), and electrochemical reduction back to hydroquinone were found by cyclic voltammetry (CV) in phosphate buffered saline (PBS) at pH 7.4. Peak current values increased linearly with increasing hydroquinone contents. The peak separation between the anodic and cathodic peaks at the PEDOP/MWCNTs-Pd/GCE was ${\Delta}Ep$ = 40 mV for HQ and ${\Delta}Ep$ = 70 mV for CA, resulting in a higher electron transfer rate. Moreover, good reproducibility, excellent storage stability, a wide linear range (0.1 ${\mu}M$ - 5 mM for HQ and 0.01 ${\mu}M$ - 6 mM for CA), and low detection limits ($2.9{\times}10^{-8}$ M for HQ and $2.6{\times}10^{-8}$ M for CA; S/N = 3) were determined using differential pulse voltammetry (DPV) and amperometric responses; this makes it a promising candidate as a sensor for determination of HQ and CA.

Template Synthesis of Nitrogen-Doped Short Tubular Carbons with Big Inner Diameter and their Application in Electrochemical Sensing

  • Cheng, Rui;Zou, Qiong;Zhang, Xiaohua;Xiao, Chunhui;Sun, Longfei;Chen, Jinhua
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.8
    • /
    • pp.2423-2430
    • /
    • 2014
  • Nitrogen-doped short tubular carbons (N-STCs) with big inner diameter have been successfully synthesized via carbonization of polydopamine (PDA) wrapped halloysite nanotubes (HNTs). The obtained N-STCs have average length of $0.3{\mu}m$ with big inner diameter (50 nm), thin wall (2-3 nm) and large surface area ($776m^2g^{-1}$), and show excellent electrochemical properties. As an example in electrochemical applications, N-STCs were used to electrochemically detect hydrogen peroxide ($H_2O_2$) and glucose. The results showed that the N-STCs modified glassy carbon (N-STCs/GC) electrode had much better analytical performance (lower detection limit and wider linear range) compared to the acid-treated carbon nanotubes (AO-CNTs) based GC electrode. The unique structure endows N-STCs the enhanced electrochemical performance and promising applications in electrochemical sensing.

Electrochemical Study of [Ni63-Se)2μ4-Se)3(dppf)3] Cluster and Its Catalytic Activity towards the Electrochemical Reduction of Carbon Dioxide

  • Park, Deog-Su;Jabbar, Md. Abdul;Park, Hyun;Lee, Hak-Myoung;Shin, Sung-Chul;Shim, Yoon-Bo
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.11
    • /
    • pp.1996-2002
    • /
    • 2007
  • The redox behavior of a [Ni6(μ3-Se)2(μ4-Se)3(Fe(η 5-C5H4P-Ph2)2)3] (= [Ni-Se-dppf], dppf = 1,1-bis(diphenylphosphino) ferrocene) cluster was studied using platinum (Pt) and glassy carbon electrodes (GCE) in nonaqueous media. The cluster showed electrochemical activity at the potential range between +1.6 and ?1.6 V. In the negative region (0 to ?1.6 V), the cluster exhibited two-step reductions. The first step was one-electron reversible, while the second step was a five-electron quasi-reversible process. On the other hand, in the positive region (0 to +1.6 V), the first step involved one-electron quasi-reversible process. The applicability of the cluster was found towards the electrocatalytic reduction of CO2 and was evaluated by experiments using rotating ring disc electrode (RRDE). RRDE experiments demonstrated that two electrons were involved in the electrocatalytic reduction of CO2 to CO at the Se-Ni-dppf-modified electrode.

Poly-3,4-dihydroxybenzaldehyde Modified with 3,4-dihydroxybenzoic acid for Improvement of Electrochemical Activities

  • Cha Seong-Keuck
    • Journal of the Korean Electrochemical Society
    • /
    • v.7 no.4
    • /
    • pp.167-172
    • /
    • 2004
  • 3,4-dihydroxybenzaldehyde(3,4-DHB) was oxidatively el electropolymerized on glassy carbon (GC) electrodes to prepare CC/p-3,4-DHB type electrodes, which were subsequently modified with 3,4-dihydroxybenzoic acid(3,4-DHBA) using 0.05M HCI as a catalyst. The esterification reactions were performed between -OH sites on the polymeric film surface of the p-3,4-DHB and the -COOH sites within the 3,4-DHBA molecules in solution. These reactions had a rate constant value of $1.1\times10^{-1}\;s^{-1}$ for the esterification step as obtained from the first-order rate constant in the solution. The electrochemical responses of the GC/p-3,4-DHB-3,4-DHBA electrodes exert an influence upon the buffer solution, its pH and applied potential ranges. The redox process of the electrode was more easily controlled by charge transfer kinetics than that of the CC/p-3,4-DHB. The modified electrodes had redox active sites that were 10 times more active than those present before modification. The electrical admittance of the modified electrodes was also three times higher than that of the unmodified electrodes. After being annealed in ethanol for 20 hrs the electrodes brought about a 3.3 times greater change of water molecules in the redox reaction. The modified electrodes are stable in the potential range of 0.4 to 0.55V.

Electrochemical Determination of Epinephrine Using Doubly Modified Electrodes with Ni(II)-Macrocyclic Complex and Polyuretane (니켈(II)-거대고리 착물과 폴리 우레탄으로 변성한 이중 전극에서 에피네피린의 전기화학적 정량)

  • Xu, Guang-Ri;Cho, Hyung-Hwa;Kweon, Soo-Geong;Lee, Sang-Hag;Bae, Zun-Ung
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.3
    • /
    • pp.190-195
    • /
    • 2007
  • A new electrochemical sensor to selectively determine epinephrine was developed and its analytical characteristics has been investigated. A glassy carbon electrode was modified with Ni(II)-macrocyclic complex which has electrocatalytic effect. It was further modified with physiologically suitable and negatively charged polyuretane benzyl L-glutamate(PUBLG). The present electrode showed long term stability and it could be applied to the selective determination of epinephrine in urine sample with various coexisting compounds. Under the optimum experimental conditions the linear range was $8.0\;{\times}\;10^{-7}\;-\;2.0\;{\times}\;10^{-4}\;M$ and the limit of detection was $1.0\;{\times}\;10^{-7}\;M$. The recovery of epinephrine in urine sample diluted 5 times with buffer solution was $101.5({\pm}3.2)%$ for 6 measurements.

Determination of Cr(Ⅵ) by Glassy Carbon and Platinum Electrodes Modified With Polypyrrole Film (폴리피롤 막으로 변성시킨 유리질 탄소 및 백금 전극에서 Cr(Ⅵ) 이온의 정량)

  • Yoo, Kwang Sik;Woo, Sang Beom;Jyoung, Jy Young
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.4
    • /
    • pp.407-411
    • /
    • 1999
  • Studies have been carried out on the fabrication of PPy/GC and PPy/Pt electrode modified with polypyrrole film and determination of Cr(VI) by using 3-electrode system with modified electrodes. Modified electrodes were able to easily fabricated by cyclic voltammetry scanned from +1.0V to -1.0V(vs. Ag/AgCl) at 50 mV/sec. Film thickness could be controlled at same condition by the number of cycling up to 26 times. Reduction behaviour of Cr(VI) at PPy/GC electrode could be seen at wide potential ranges from +0.6V to -0.5V(vs. Ag/AgCl), and maximum reduction peak potential of the ion was observed at -0.25V(vs.Ag/AgCl). Calibration graph at its potential was linear from 0.1 ppm to 80.O ppm. Slope factor and relative coefficient were 1.75 mA/ppm and 0.998, respectively. Reduction behaviour of Cr(VI) at PPy/Pt electrode was similar to PPy/GC electrode, Calibration graph was linear from l.0 ppm to 60.0 ppm. Slope factor and relative coefficient were 0.5mA/ppm and 0.923, respectively. But PPy/GC modified electrode had about 3 times higher sensitivity than PPy/Pt modified electrode. Reduction behaviour of Cu(II), As(IlI), Pb(II), and Cd(II) couldn't be seen at PPy/GC electrode,Its metals had not lnterfered with Cr (VI) determination.

  • PDF

The Electrocatalytic Reduction of Molecular Oxygen with Clay Modified Electrodes (점토광물을 이용한 산소환원의 전기화학적 촉매성에 관한 연구)

  • Oh Sung-Hun;Hwang Jin-Yeon;Shim Yoon-Bo;Lee Hyomin;Yoon Jihae
    • Journal of the Mineralogical Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.1-9
    • /
    • 2005
  • The electrocatalytic reduction of O₂ was investigated with methyl viologen and methylene blue incorporated clay-modified electrodes. Clay suspensions were prepared with Na-montmorillonite, Ca-montmorillonite, and kaolinite. The methyl viologen-clay modified electrodes were made by coating clay suspensions adsorbing methyl viologen on a glassy carbon electrode. Cyclic voltammetry were performed in aqueous media to investigate the electrocatalytic property of the modified electrode in reducing O₂. A Na-montmorillonite modified electrode showed the greatest adsorption capacity for methyl viologen. The modified electrode made of Na-montmorillonite suspension of 0.87 g/10 mL and a 2.5 mM of methyl viologen solution showed the most effective electrocatalytic property, where the catalytic reduction potential was shifted by 242.6 mV toward the positive potential. The electrocatalytic ability was more significant in acidic (pH=3.7) and alkaline (pH=12.7) media than the neutral pH range (6.3∼8.3). The methyl viologen-Na-montmorillonite modified electrode had the good reproducibility and maintain the electrocatalytic property over 20 times reuse.

Ion-Imprinted Polymers Modified Sensor for Electrochemical Detection of Cu2+

  • An, Zhuolin;Liu, Weifeng;Liang, Qi;Yan, Guang;Qin, Lei;Chen, Lin;Wang, Meiling;Yang, Yongzhen;Liu, Xuguang
    • Nano
    • /
    • v.13 no.12
    • /
    • pp.1850140.1-1850140.9
    • /
    • 2018
  • An electrochemical sensor ($Cu^{2+}$-IIPs/GCE) was developed for detection of $Cu^{2+}$ in water. $Cu^{2+}$-IIPs/GCE was prepared by dispersing $Cu^{2+}$ imprinted polymers ($Cu^{2+}$-IIPs) on a preprocessed glassy carbon electrode. $Cu^{2+}$-IIPs were synthesized on the surface of modified carbon spheres by ion imprinting technology. The electrochemical performance of $Cu^{2+}$-IIPs/GCE was evaluated by differential pulse voltammetry method. The response of $Cu^{2+}$-IIPs/GCE to $Cu^{2+}$ was linear in $1.0{\times}10^{-5}mol/L$ to $1.0{\times}10^{-3}mol/L$. The detection limit was $5.99{\times}10^{-6}mol/L$ (S=N = 3). The current response value of $Cu^{2+}$-IIPs/GCE was 2.14 times that of the nonimprinted electrode. These results suggest that $Cu^{2+}$-IIPs/GCE can detect the concentration of $Cu^{2+}$ in water, providing a new way for heavy metal ions adsorption and testing.

Electrochemical determination of chloramphenicol using a glassy carbon electrode modified with dendrite-like Fe3O4 nanoparticles

  • Giribabu, Krishnan;Jang, Sung-Chan;Haldorai, Yuvaraj;Rethinasabapathy, Muruganantham;Oh, Seo Yeong;Rengaraj, Arunkumar;Han, Young-Kyu;Cho, Wan-Seob;Roh, Changhyun;Huh, Yun Suk
    • Carbon letters
    • /
    • v.23
    • /
    • pp.38-47
    • /
    • 2017
  • In this study, magnetite ($Fe_3O_4$) nanoparticles were electrochemically synthesized in an aqueous electrolyte at a given potential of -1.3 V for 180 s. Scanning electron microscopy revealed that dendrite-like $Fe_3O_4$ nanoparticles with a mean size of < 80 nm were electrodeposited on a glassy carbon electrode (GCE). The $Fe_3O_4/GCE$ was utilized for sensing chloramphenicol (CAP) by cyclic voltammetry and square wave voltammetry. A reduction peak of CAP at the $Fe_3O_4/GCE$ was observed at 0.62 V, whereas the uncoated GCE exhibited a very small response compared to that of the $Fe_3O_4/GCE$. The electrocatalytic ability of $Fe_3O_4$ was mainly attributed to the formation of Fe(VI) during the anodic scan, and its reduction to Fe(III) on the cathodic scan facilitated the sensing of CAP. The effects of pH and scan rate were measured to determine the optimum conditions at which the $Fe_3O_4/GCE$ exhibited the highest sensitivity with a lower detection limit. The reduction current for CAP was proportional to its concentration under optimized conditions in a range of $0.09-47{\mu}M$ with a correlation coefficient of 0.9919 and a limit of detection of $0.09{\mu}M$ (S/N=3). Moreover, the fabricated sensor exhibited anti-interference ability towards 4-nitrophenol, thiamphenicol, and 4-nitrobenzamide. The developed electrochemical sensor is a cost effective, reliable, and straightforward approach for the electrochemical determination of CAP in real time applications.