• Title/Summary/Keyword: Modified carbon paste electrode

Search Result 42, Processing Time 0.025 seconds

Voltammetric Determination of Copper(II) at Chemically Modified Carbon Paste Electrodes Containing Alga

  • Bae, Zun-Ung;Kim, Young-Lark;Chang, Hye-Young
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.611-615
    • /
    • 1995
  • The design of appropriate chemically modified electrodes should allow development of new voltammetric measurement schemes with enhanced selectivity and sensitivity. Microorganism like algae has high ability to trap toxic and heavy metal ions and different affinities for metal ions. A copper(II) ion-selective carbon paste electrode was constructed by incorporating alga Anabaena into a conventional carbon paste mixture, and then the film of 10% Nafion was coated to avoid the swelling of the electrode surface. Copper ion could be deposited at the 25% algamodified electrode for 15 min without the applied potential while stirring the solution by only immersing the electrode in a buffer (pH 4.0) cot1taining copper(II). Temperature was controlled at $35^{\circ}C$. After preconcentration was carried out the electrode was transferred to a 0.1 M potassium chloride solution and was reduced at -0.6 volt at $25^{\circ}C$. The differential pulse anodic stripping voltammetry was employed. A well-defined oxidation peak could be obtained at -0.1 volt (vs SCE). In five deposition / measurement / regeneration cycles, the responses were reproducible and relative standard deviations were 3.3% for $8.0{\times}10^{-4}M$ copper(II). Calibration curve for copper was linear over the range from $2.0{\times}10^{-4}M$ to $1.0{\times}10^{-3}M$. The detection limit was $7.5{\times}10^{-5}M$. Studies of the effect of diverse ions showed that the coexisting metal ions had little or no effect for the determination of copper. But anions such as cyanide. oxalate and EDTA seriously interfered.

  • PDF

Voltammetric Determination of Droxidopa in the Presence of Tryptophan Using a Nanostructured Base Electrochemical Sensor

  • Yaghoubian, Halimeh;Jahani, Shohreh;Beitollahi, Hadi;tajik, Somayeh;Hosseinzadeh, Rahman;Biparva, Pouria
    • Journal of Electrochemical Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.109-117
    • /
    • 2018
  • A novel carbon paste electrode modified with $Cu-TiO_2$ nanocomposite, 2-(ferrocenylethynyl)fluoren-9-one (2FF) and ionic liquid (IL) (2FF/$Cu-TiO_2$/IL/CPE) was fabricated and employed to study the electrocatalytic oxidation of droxidopa, using cyclic voltammetry (CV), chronoamperometry (CHA) and differential pulse voltammetry (DPV) as diagnostic techniques. It has been found that the oxidation of droxidopa at the surface of modified electrode occurs at a potential of about 295 mV less positive than that of an unmodified CPE. DPV exhibits a linear dynamic range from $5.0{\times}10^{-8}$ to $4.0{\times}10^{-4}M$ and a detection limit of 30.0 nM for droxidopa. Finally this modified electrode was used for simultaneous determination of droxidopa and tryptophan. Also the 2FF/$Cu-TiO_2$/IL/CPE shows excellent ability to determination of droxidopa and tryptophan in real samples.

Use of hybrid materials in the trace determination of As(V) from aqueous solutions: An electrochemical study

  • Tiwari, Diwakar;Jamsheera, A.;Zirlianngura, Zirlianngura;Lee, Seung Mok
    • Environmental Engineering Research
    • /
    • v.22 no.2
    • /
    • pp.186-192
    • /
    • 2017
  • The carbon paste electrode (CPE) was modified with the pristine bentonite and hybrid material (HDTMA-modified bentonite). The modified-CPEs are then employed as working electrode in an electrochemical detection of As(V) from aqueous solutions using the cyclic voltammetric measurements. Cyclic voltammograms revealed that As(V) showed reversible behavior onto the working electrode. The hybrid material-modified carbon paste electrode showed significantly enhanced electrochemical signal which was then utilized in the low level detection of As(V). Moreover, the studies were conducted at neutral pH conditions. The electrochemical studies were conducted with scan rates (20 to 200 mV/s) to deduce the mechanism of redox processes involved at the electrode surface. The anodic current was linearly increased, increasing the concentration of As(V) from 5.0 to $35.0{\mu}g/g$ using the hybrid material-modified electrode. This provided fairly a good calibration line for As(V) detection. The presence of varied concentrations of As(III) in the determination of total arsenic was studied. The influence of several cations and anions viz., Cu(II), Mn(II), Zn(II), Pb(II), Cd(II), Fe(III), $Cl^-$, $NO_3{^-}$, $PO_4{^{3-}}$, EDTA and glycine in the detection of As(V) from aqueous solution was also studied. Further, in an attempt to simulate the real matrix analysis, the tap water sample was spiked with As(V) and subjected for As(V) detection using the modified-CPE.

Determination of Ag(Ⅰ) Ion at a Modified Carbon Paste Electrode Containing N,N'-Diphenyl Oxamide

  • Won, Mi-Sook;Yeom, Jeong-Sik;Yoon, Jang-Hee;Jeong, Euh-Duck;Shim, Yoon-Bo
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.7
    • /
    • pp.948-952
    • /
    • 2003
  • New approach for the determination of Ag(I) ion was performed by using a carbon paste electrode (CPE) containing N,N'-Diphenyl oxamide (DPO) with anodic stripping voltammetry. The CMEs have been prepared by making carbon paste mixtures containing an appropriate amount of DPO salt coated onto graphite particles to analyze trace metal ions via complexation followed by stripping voltammetry. Various experimental parameters affecting the response, such as pH, deposition time, temperature, and electrode composition, were carefully optimized. Using differential pulse anodic stripping voltammetry, the logarithmic linear response range for the Ag(I) ion was 1.0 × $10^{-7}$ - 5.0 × $10^{-9}$ M at the deposition time of 10 min, with the detection limit was 7.0 × $10^{-10}$ M. The detection limit adopted from anodic stripping differential pulse voltammetry was 7.0 × $10^{-10}$ M for silver and the relative standard deviation was ± 3.2% at a 5.0 × $10^{-8}$ M of Ag(I) ion (n = 7). The proposed electrode shows a very good selectivity for Ag(I) in a standard solution containing several metals at optimized conditions.

Determination of Ag(Ⅰ) Ion with a Chemically Modified Carbon Paste Electrode Containing Cinchonidine (Cinchonidine으로 변성된 Carbon Paste 전극을 사용한 은이온의 정량)

  • Kim, Sin Hui;Won, Mi Suk;Sim, Yun Bo
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.10
    • /
    • pp.734-740
    • /
    • 1994
  • Electrochemical determination of Ag(I) ion was carried out by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) with the carbon paste electrode (CPE) containing cinchonidine. The detection limit for Ag(I) ion was shown to be $1.0 {\times}10^{-6}$ M in conventional CV and up to $8.0{\times}10^{-9}$ M (${\pm}$0.6%) using DPV. The optimum analytical condition of Ag(I) ion was determined as follows: pH 7, 20 minutes of deposition time, and 50% (w/w) cinchonidine to carbon powder composition of electrode. The interference effect of various metal ions added to the deposition solution was also studied. The peak current of Ag(I) ion except Hg(II) ion was decreased roughly 25% compare to Ag(I) ion only. When Mn(II) ion was present in sample solution at pH 9, shown a large interference effect.

  • PDF

Amperometric Electronic Tongue Based on Metal Oxide Containing Carbon Paste Electrode Array (금속 산화물을 포함한 탄소반죽 전극 어레이로 제작한 전자 혀)

  • Han Jong Ho;Kim Dong Sun;Kim Jong Sik;Yoon In Jun;Cha Geun Sig;Nam Hakhyun
    • Journal of the Korean Electrochemical Society
    • /
    • v.7 no.4
    • /
    • pp.206-210
    • /
    • 2004
  • All array of carbon paste-based electrodes was prepared by screen printing the carbon paste modified with metal oxides $(TiO_2,\;RuO_2,\;PbO_2,\;Ni(OH)_2)$ and Prussian blue (PB). An electronic tongue system was assembled with the carbon-paste electrode array, and applied to discriminate the tastes of various commercial beverages and foods by measuring the chronoamperometric responses to the samples diluted in 0.1M carbonate buffer (pH 9.6). The results were analyzed with principal component analysis(PCA) method and plotted on two dimensional PCA coordinate; it was apparent that the amperometric electronic tongue system could discriminate the types of various foods and beverages.

Electrochemistry of Hemoglobin in the Chitosan and TiO2 Nanoparticles Composite Film Modified Carbon Ionic Liquid Electrode and Its Electrocatalysis

  • Sun, Wei;Li, Xiaoqing;Liu, Shufeng;Jiao, Kui
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.3
    • /
    • pp.582-588
    • /
    • 2009
  • Direct electron transfer of hemoglobin (Hb) in the chitosan (CTS) and $TiO_2$ nanoparticles (nano-$TiO_2$) composite films was achieved by using a room temperature ionic liquid of 1-butyl-3-methylimidazolium hexafluorophosphate ($BMIMPF_6$) modified carbon paste electrode (CILE) as the basal electrode. UV-Vis and FT-IR spectroscopy indicated that Hb in the film retained the native structure. Electrochemical investigation indicated that a pair of well-defined quasi-reversible redox peaks of Hb heme Fe(III)/Fe(II) was obtained with the formal potential located at -0.340 V (νs. SCE) in pH 7.0 phosphate buffer solution (PBS). The electrochemical parameters such as the electron transfer coefficient (α), the electron transfer number (n) and the standard electron transfer rate constant ($k_s$) were got as 0.422, 0.93 and 0.117 $s^{-1}$, respectively. The fabricated CTS/nano-$TiO_2$/Hb/CILE showed good electrocatalytic ability to the reduction of trichloroacetic acid (TCA) and hydrogen peroxide ($H_2O_2$), which exhibited a potential application in fabricating a new kind of third generation biosensor.

Voltammetric Determination of Dopamine with the N-Hydroxysuccinimide Modified Carbon Paste Electrode (N-히드록시숙신이미드로 수식한 탄소반죽전극을 이용한 도파민의 전기화학적 측정)

  • Yoo Jae Hyun;Yoo Byung Wook;Kim Soon Shin;Uhm Jung Hee;Nam Hakhyun;Cha Geun Sig
    • Journal of the Korean Electrochemical Society
    • /
    • v.4 no.3
    • /
    • pp.109-112
    • /
    • 2001
  • An activated carbon paste electrode was modified with the N-Hydroxysuccinimide(NHS) layer and applied to determine the dopamine in the presence of an excess ascorbic acid using square-wave voltammetry. The electrochemical properties of the modified electrode were examined in the solution containing dopamine/ascorbic acid using cyclic voltammetry(CV): the separation between the oxidation peaks of dopamine and ascorbic acid was largely dependent on the pH of the sample solution and became maximum at pH 4.0. Hence, the square-wave voltammetric determination of dopamine was carried out in a pH 4.0, 100mM phosphate buffer saline(PBS) containing 140mM NaCl. The detection limit and response slop were improved from $1.0{\mu}M\;to\;5.0\times10^{-2}{\mu}M\;and\;from\;0.93{\mu}A/{\mu}M\;to\;6.1{\mu}A/{\mu}M$, respectively, upon modification of the electrode surface by NHS.

Determination of Derivatives of Phenol with a Modified Electrode Containing β-Cyclodextrin

  • 김신희;원미숙;심윤보
    • Bulletin of the Korean Chemical Society
    • /
    • v.17 no.4
    • /
    • pp.342-347
    • /
    • 1996
  • Voltammetric determination of phenol derivatives, such as phenol, o-, m-, and p-cresols was studied with a β-Cyclodextrin (β-CD) modified-carbon paste electrode composing of the graphite powder and Nujol oil. Phenol derivatives were chemically deposited via the complex formation with β-CD by immersing the CME into a sample solution. The resulting surfaces were characterized with cyclic and differential pulse voltammetry. Treating the CME with 1 M nitric acid for five sec after a measurement could regenerate the electrode surface. Linear sweep and differential pulse voltammograms were recorded for the above system to optimize the experimental parameters for analysing the phenol derivatives. In this case, the detection limit for phenols was 5.0×10-7M for 25 min of the deposition time with differential pulse voltammetry. The relative standard deviation was ±5.2% of 3.0×10-6M (four repetitions). The interference effect of the following organic compounds was also investigated; Bezoic acid, hippuric acid, o-, m-, and p-methylhippuric acid. Adding the organic compounds into the sample solution reduces the peak current of the phenols to about 25%.