• 제목/요약/키워드: Modified Test Method

검색결과 1,206건 처리시간 0.022초

A Study on the Antibacterial Activity of Chitosan on the MRSA by the AATCC Test Method 100 and Modified AATCC Test Method 100

  • Choi, Jeong-Im;Jeon, Dong-Won
    • 한국의류산업학회지
    • /
    • 제4권6호
    • /
    • pp.557-563
    • /
    • 2002
  • Water-soluble chitosan and water-insoluble chitosan with molecular weight of 2,000,000, 500,000, 80,000, and 40,000 with more than 90%of degree of deacetylation were produced to test antibacterial activity of chitosan against a pathogenic bacteria, Methicillin Resistant Staphylococcus aureus(MRSA). the AATCC Test Method 100and Modified AATCC Test Method 100 were used to evaluate the antibacterial activity of chitosan. Antibacterial activity of chitosan/acetic acid solution was the same when they were tested by two different methods, but those of polyester fabrics treated with chitosan/acetic acid solution were different in different antibacterial test. So several problems were found in the experimental methods. The AATCC Test Method 100 seems that excessive nutrition exists in inoculum solution by quantitative analysis on the basis the result of antibacterial activity on chitosan/acetic acid solution and amount of chitosan attached to the surface of treated fabrics.

액체식 평판형 태양열 집열기 성능 실험의 표준화에 관한 연구 (A Study on the Standardization of Test Method of Flat-Plate Liquid-heating Solar Collectors)

  • 윤석범
    • 한국안전학회지
    • /
    • 제5권3호
    • /
    • pp.27-32
    • /
    • 1990
  • Standardization of solar collector test method is desirable for improvement solar collector quality and Valuation of collector thermal performance. In the present work, test loop proposed by Chun, is modified for convenience of test and obtained accurate collector thermal performance. An experimental investigation hat been carried out with a modified collector test loop under a real sun condition in order to confirm the utility of modified test loop and study the effect of variation of flow rate on thermal efficiency, the range of optimum flow rate and critical incident angle.

  • PDF

A MODIFIED INEXACT NEWTON METHOD

  • Huang, Pengzhan;Abduwali, Abdurishit
    • Journal of applied mathematics & informatics
    • /
    • 제33권1_2호
    • /
    • pp.127-143
    • /
    • 2015
  • In this paper, we consider a modified inexact Newton method for solving a nonlinear system F(x) = 0 where $F(x):R^n{\rightarrow}R^n$. The basic idea is to accelerate convergence. A semi-local convergence theorem for the modified inexact Newton method is established and an affine invariant version is also given. Moreover, we test three numerical examples which show that the modified inexact scheme is more efficient than the classical inexact Newton strategy.

관능검사(官能檢査)에 관한 연구(硏究) -[제4보(第4報)] 3점비교법(點比較法)의 신변형(新變形)에 대하여- (Studies on Sensory Evaluation -[Part IV] New Modified Triangle Test-)

  • 홍진
    • Applied Biological Chemistry
    • /
    • 제20권3호
    • /
    • pp.285-291
    • /
    • 1977
  • (가) 2개 이상(以上) t개의 시료(試料)를 3점기호척도시험법(點嗜好尺度試驗法)에 의해 실험한 결과를 통계처리(統計處理)하여 t개 시료 상호간(相互間)의 품질차(品質差)를 비교(比較)하는 해석법(解析法)에 대해서 검토(檢討) 하였다. (나) 그 결과 $Scheff{\acute{e}}'s$ method의 제1신법(第1新法)이 품질차(品質差)의 검출력(檢出力)에서나 얻어지는 정보량(情報量)에서 우수(優秀)함을 확인하고 t개의 시료에 대할 3점기호척도시험법(點嗜好尺度試驗法)의 해석방법(解析方法)으로써 실용성(實用性)이 있다는 결론을 얻었다. (다) 이때 correct oddity chosen에 대한 incorrec toddity chosen의 weight fraction은 chance probability에 의해 계산하여 1/2로 하였다.

  • PDF

Shake Flask Method와 개량 Shake Flask Method에 의한 키토산의 MRSA 향균성 평가 (A Study on the Antibacterial Activity of Chitosan on the MRSA by the Shake Flask Method and Modified Shake Flask Method)

  • 최정임;전동원
    • 한국의류산업학회지
    • /
    • 제5권1호
    • /
    • pp.64-70
    • /
    • 2003
  • Water-insoluble chitosan with molecular weight of 2,000,000, 580,000, 80,000, and 40,000 and more than 90% of degree of deacetylation were prepared to test antibacterial activity of chitosan against a pathogenic bacteria, methicillin resistant Staphylococcus aureus (MRSA). As experimental method, the Shake Flask Method (SFM) and Modified Shake Flask Method (MSFM) were applicated. The anti-microbial activity of chitosan/acetic acid aqueous solution is consistent irrespective of Mw of chitosan. MIC value of SFM measurement was 0.2 ppm, and MIC value of modified SFM measurement was 25 ppm. But MIC value of chitosan/acetic add solution and chitosan treated cotton filter paper was equally 5 ppm. The antibacterial activities of chitosan were different in different test measurements employed. The antibacterial activities of chitosan/acetic acid solution and chitosan treated cotton filter paper were also different. Therefore, it needs to be pointed out that the test measurements of anti-microbial activity have some problems.

우유(牛乳)의 Chlorine치(値) 측정(測定)에 의한 유방염진단(乳房炎診斷)에 관한 연구(硏究) (Studies on Dignosis of Mastitis by Chlorine Detection in Milk)

  • 김교준
    • 대한수의학회지
    • /
    • 제19권1호
    • /
    • pp.63-67
    • /
    • 1979
  • In order to investigate modified Hayden test for mastitis test milk Samples from 120 cows (total 470 of quarters) were tested by this method. The tests were performed by different lactation age group, different calving frequency and their total quarters. Comparision of results were made between the modified Hayden method and the California Mastitis Test. The results obtained were as follows: 1. Ratio of results of mastitis test between modified Hayden method and California Mastitis Test was 1.1:1.0. 2. Incidence rate of mastitis in different Lactation age group shown 78.5% in 7 to 9 year group, 50% in 4 to 6 year age group and 37.5% in up to 3 year age group, respectively. 3. Incidence rate of mastitis with calving frequency, were 13.5% in 1 to 2 calving frequency group, 83.3% in 3 to 4 calving frequency group and 63.6% in 5 to 6 calving frequency group respectively. 4. Mastitis ratio between rear quarters and front quaters were 1.7:1.0. 5. It is probable that modified Hayden was more sensitive than the California mastitis test in detecting subclinical and clinical mastitis.

  • PDF

변형된 Classification Tree Method를 이용한 BLDC 모터제어기 파괴 시험 (Destructive Test of a BLDC Motor Controller Utilizing a Modified Classification Tree Method)

  • 신재혁;정기현;최경희
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제3권6호
    • /
    • pp.201-214
    • /
    • 2014
  • 본 논문에서는 차량에 사용되는 MDPS(Motor Driven Power Steering) 시스템에 사용되는 BLDC(Brush Less Direct Current) 모터 제어기의 파괴 시험에 적합한 테스트 케이스 생성 방법을 제시한다. 제안하는 방법은 입력 기반 테스트 방법의 하나인 CTM(Classification Tree Method)을 수정한 방법이다. CTM은 모든 입력의 중요도를 동등하게 가정하고 테스트 케이스를 생성하는 방법이다. 따라서 극한 상황과 같은 테스트 케이스를 생성하기 힘들다. 이와 같은 단점을 극복하고, 파괴 시험에 적합한 테스트 케이스를 생성하기 위해 CTM의 한계점을 보완한 변형된 CTM 재구성 방법을 제안한다. 제안하는 방법은 CTM의 장점을 유지하면서 CTM으로 만들어진 테스트 케이스를 조합하여 특정 상황의 테스트에 적합한 시나리오를 집중적으로 생성할 수 있는 장점을 가진다. 제안한 방식을 이용해 파괴 시험을 위한 테스트 시나리오를 생성하고, 이를 이용하여 승용차에 사용되고 있는 MDPS 시스템에 대한 테스트를 수행하여 제안한 방법의 유용성을 검증한다.

Repeatability and Reliability of a New Phoria Test Using Flashed and Auto-flashed Presentation

  • Moon, Byeong-Yeon;Park, Sun-Young;Cho, Hyun Gug
    • Journal of the Optical Society of Korea
    • /
    • 제16권4호
    • /
    • pp.418-424
    • /
    • 2012
  • The purpose of this study was to assess repeatability and reliability of a new phoria test as compared to established phoria tests and to assess the possibility of mobile or online testing using the auto-flashed presentation. Near dissociated phoria was measured using the von Graefe method, the Howell card test, the modified Thorington test, and a new dichromatic card test (Red-Blue Phoria card test; RBP card test) on 109 subjects. The inter-examiner difference and test-retest difference were calculated. With the auto-flashed presentation of the RBP card test, near dissociated phoria was measured and the intraclass correlation coefficient and test-retest repeatability was assessed on 26 subjects. The variation in inter-examiner repeatability was the smallest for the modified Thorington test (+3.1/-2.6). The RBP card test was +3.0/-3.1, the Howell card test was +3.5/-2.7, and the von Graefe test was +6.2/-6.0. The variation in test-retest repeatability was the smallest for the RBP card test (+0.4/-1.4). The modified Thorington test was +1.3/-1.3, the Howell card test was +1.27/-1.45, and the von Graefe test was +1.59/-2.20. The ICC was 0.919 for the auto-flashed presentation of the RBP card test. The RBP card test is considered a highly repeatable method clinically and can be made a useful application for testing in mobile or online.

간척지 온실기초 나무말뚝의 인발저항력 예측을 위한 실내모형시험 결과 비교·분석 (Comparision Analysis of Model Test for Prediction of Uplift Resistance in the Reclaimed Land Greenhouse Foundation)

  • 송창섭;김명환;장웅희
    • 한국농공학회논문집
    • /
    • 제58권2호
    • /
    • pp.45-52
    • /
    • 2016
  • The object of this paper was to evaulate modified proposed design equation in model test result in order to estimate uplift-resistance of timber pile of reclaimed land greenhouse foundation. Uplift resistance result of model test was increased to according to increased of contact area. Uplift-resistance result of field test tend to lineary increased to according to increased of embedment depth and contact area. Results of field uplift-resistance was evaluate compare with modified proposed design equation results of model test and Effective stress method. As the Effective stress method tend to underestimate, modified proposed design equation results of model test tend to similar type. As the contact area increase, difference between field uplift-resistance results and modified proposed design equation results of model test was considered uplift-speed.

BOX 형 지하구조물의 내진설계 기준 확립을 위한 해석기법개발 (Development of the Modified Seismic Coefficient Method to Establish Seismic Design Criteria of Buried Box Structures.)

  • 박성우
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.194-201
    • /
    • 2000
  • In this study the modified seismic coefficient method for seismic analysis of buried box structures is developed for practical purpose. The loading coefficient in the modified seismic coefficient method is determined from the results of the response displacement analysis. In the developed method adequate velocity response spectrum in accordance with soil condition is also needed to seismic design of buried box structures, In order to investigate applicability of the modified seismic coefficient method various analyses are performed with different parameters such as depth of base rock height and width of box buried depth and value of standard penetration test. Results from the modified seismic coefficient method are compared with those of the response displacement method in terms of the maximum bending moment and the location of it. From the comparison it is shown that the feasibility of the modified seismic coefficient method for seismic analysis of buried box structures.

  • PDF