• Title/Summary/Keyword: Model scanner

Search Result 398, Processing Time 0.025 seconds

Development and Performance Evaluation of the First Model of 4D CT-Scanner

  • Endo, Masahiro;Mori, Shinichiro;Tsunoo, Takanori;Kandatsu, Susumu;Tanada, Shuji;Aradate, Hiroshi;Saito, Yasuo;Miyazaki, Hiroaki;Satoh, Kazumasa;Matsusita, Satoshi;Kusakabe, Masahiro
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.373-375
    • /
    • 2002
  • 4D CT is a dynamic volume imaging system of moving organs with an image quality comparable to conventional CT, and is realized with continuous and high-speed cone-beam CT. In order to realize 4D CT, we have developed a novel 2D detector on the basis of the present CT technology, and mounted it on the gantry frame of the state-of-the-art CT-scanner. In the present report we describe the design of the first model of 4D CT-scanner as well as the early results of performance test. The x-ray detector for the 4D CT-scanner is a discrete pixel detector in which pixel data are measured by an independent detector element. The numbers of elements are 912 (channels) ${\times}$ 256 (segments) and the element size is approximately 1mm ${\times}$ 1mm. Data sampling rate is 900views(frames)/sec, and dynamic range of A/D converter is 16bits. The rotation speed of the gantry is l.0sec/rotation. Data transfer system between rotating and stationary parts in the gantry consists of laser diode and photodiode pairs, and achieves net transfer speed of 5Gbps. Volume data of 512${\times}$512${\times}$256 voxels are reconstructed with FDK algorithm by parallel use of 128 microprocessors. Normal volunteers and several phantoms were scanned with the scanner to demonstrate high image quality.

  • PDF

Accuracy of Bite Registration Using Intraoral Scanner Based on Data Trimming Strategy for Fremitus Teeth

  • Jeong, Yuwon;Shim, June-Sung;Kim, Jee-Hwan;Kim, Jong-Eun;Lee, Hyeonjong
    • Journal of Korean Dental Science
    • /
    • v.15 no.1
    • /
    • pp.61-67
    • /
    • 2022
  • Purpose: This study aimed to evaluate the accuracy of bite registration using intraoral scanner based on data trimming strategy for fremitus teeth. Materials and Methods: A reference model was designed by Medit Model Builder software (MEDIT Corp., Seoul). Tooth number 24 and 25 were separated as dies and tooth number 26 was prepared for full-coverage crown. Those were printed using a 3D printer (NextDent 5100). The scanning procedure was performed by a single trained operator with one intraoral scanner (i700; MEDIT Corp.). The scanning groups were divided as follows: group 1 (G1), no fremitus; group 2 (G2), 0.5 mm buccal fremitus in the maxillary left first and second premolar; and group 3 (G3), 1.5 mm buccal fremitus in the maxillary left first and second premolar. Each group was scanned 10 times and were analyzed using the reference model data. Surface-based occlusal clearance was analyzed at the prepared tooth to evaluate accuracy. Result: Mean values of control group (G1) were 1.587±0.021 mm. G2 showed similar values to those from the control group (1.580±0.024 mm before trimming strategy and 1.588±0.052 mm after trimming strategy). G3 showed significantly greater values (1.627±0.025 mm before trimming strategy and 1.590±0.024 mm after trimming strategy) and the differences were found between trimming strategy (P=0.004). Conclusion: Bite trimming strategy for fremitus teeth is a reliable technique to reduce inaccuracies caused by the mobility at maximum intercuspation.

Application of Thermal Discharge Dispersion Model on Cheonsu Bay (천수만 해역에서 온배수 확산모델의 적용)

  • 박영기
    • Journal of Environmental Science International
    • /
    • v.4 no.2
    • /
    • pp.169-180
    • /
    • 1995
  • This Daper presents effective simulation of the dispersion of thermal discharge which can be relesed at Boryong power plant. Applied numerical models are finite difference method for hydrodynamic analysis and Masch-model comprised of conditions for ambient current velocity. Application of these models is done in Cheonsu Bay Summing up the results of this study are as follows; 1. It is found that the result for measurements of temperature appears high at southwardly Songdo on flood. The reason is that tidal currents which flowed north direction were accompanied with southwardly dispersed thermal discharge. A minute Particle of thermal Plume has a tendency to dispels inward Deacheon Bay. 2. According to the results of numerical experiment, maximum distance for thermal discharge dispersion appeared 10.8 km at lower part and 8.6 km at upper part with power plant outlet as starting point. 3. Comparative the numerical simulation and Airbone Multispectral Scanner indicated that thermal discharge should be verified separative phenomena. The simulated results were compared with field data set showing good agreement. It is concluded that these model can be simulated well.

  • PDF

Comparison of Reproducibility of Linear Measurements on Digital Models among Intraoral Scanners, Desktop Scanners, and Cone-beam Computed Tomography

  • Jo, Deuk-Won;Kim, Mijoo;Kim, Reuben H.;Yi, Yang-Jin;Lee, Nam-Ki;Yun, Pil-Young
    • Journal of Korean Dental Science
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2022
  • Purpose: Intraoral scanners, desktop scanners, and cone-beam computed tomography (CBCT) are being used in a complementary way for diagnosis and treatment planning. Limited patient-based results are available about dimensional reproducibility among different three-dimensional imaging systems. This study aimed to evaluate dimensional reproducibility among patient-derived digital models created from an intraoral scanner, desktop scanner, and two CBCT systems. Materials and Methods: Twenty-nine arches from sixteen patients who were candidates for implant treatments were enrolled. Different types of CBCT systems (KCT and VCT) were used before and after the surgery. Polyvinylsiloxane impressions were taken on the enrolled arches after the healing period. Gypsum casts were fabricated and scanned with an intraoral scanner (CIOS) and desktop scanner (MDS). Four test groups of digital models, each from CIOS, MDS, KCT, and VCT, respectively, were compared to the reference gypsum cast group. For comparison of linear measurements, intercanine and intermolar widths and left and right canine to molar lengths were measured on individual gypsum cast and digital models. All measurements were triplicated, and the averages were used for statistics. Bland-Altman plots were drawn to assess the degree of agreement between each test group with the reference gypsum cast group. A linear mixed model was used to analyze the fixed effect of the test groups compared to the reference group (α=0.05). Result: The Bland-Altman plots showed that the bias of each test group was -0.07 mm for CIOS, -0.07 mm for MDS, -0.21 mm for VCT, and -0.25 mm for KCT. The linear mixed model did not show significant differences between the test and reference groups (P>0.05). Conclusion: The linear distances measured on the digital models created from CIOS, MDS, and two CBCT systems showed slightly larger than the references but clinically acceptable reproducibility for diagnosis and treatment planning.

White light scanner-based repeatability of 3-dimensional digitizing of silicon rubber abutment teeth impressions

  • Jeon, Jin-Hun;Lee, Kyung-Tak;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.452-456
    • /
    • 2013
  • PURPOSE. The aim of this study was to evaluate the repeatability of the digitizing of silicon rubber impressions of abutment teeth by using a white light scanner and compare differences in repeatability between different abutment teeth types. MATERIALS AND METHODS. Silicon rubber impressions of a canine, premolar, and molar tooth were each digitized 8 times using a white light scanner, and 3D surface models were created using the point clouds. The size of any discrepancy between each model and the corresponding reference tooth were measured, and the distribution of these values was analyzed by an inspection software (PowerInspect 2012, Delcamplc., Birmingham, UK). Absolute values of discrepancies were analyzed by the Kruskal-Wallis test and multiple comparisons (${\alpha}$=.05). RESULTS. The discrepancy between the impressions for the canine, premolar, and molar teeth were $6.3{\mu}m$ (95% confidence interval [CI], 5.4-7.2), $6.4{\mu}m$ (95% CI, 5.3-7.6), and $8.9{\mu}m$ (95% CI, 8.2-9.5), respectively. The discrepancy of the molar tooth impression was significantly higher than that of other tooth types. The largest variation (as mean [SD]) in discrepancies was seen in the premolar tooth impression scans: $26.7{\mu}m$ (95% CI, 19.7-33.8); followed by canine and molar teeth impressions, $16.3{\mu}m$ (95% CI, 15.3- 17.3), and $14.0{\mu}m$ (95% CI, 12.3-15.7), respectively. CONCLUSION. The repeatability of the digitizing abutment teeth's silicon rubber impressions by using a white light scanner was improved compared to that with a laser scanner, showing only a low mean discrepancy between $6.3{\mu}m$ and $8.9{\mu}m$, which was in an clinically acceptable range. Premolar impression with a long and narrow shape showed a significantly larger discrepancy than canine and molar impressions. Further work is needed to increase the digitizing performance of the white light scanner for deep and slender impressions.

A study on the accuracy evaluation of dental die models manufactured by 3D printing method (3D 인쇄방법으로 제작된 치과용 다이 모델의 정확도 평가연구)

  • Jang, Yeon
    • Journal of Technologic Dentistry
    • /
    • v.41 no.4
    • /
    • pp.287-293
    • /
    • 2019
  • Purpose: To evaluate the accuracy of the 3D printed die models and to investigate its clinical applicability. Methods: Stone die models were fabricated from conventional impressions(stone die model; SDM, n=7). 3D virtual models obtained from the digital impressions were manufactured as a 3D printed die models using a 3D printer(3D printed die models;3DM, n=7). Reference model, stone die models and 3D printed die models were scanned with a reference scanner. All dies model dataset were superimposed with the reference model file by the "Best fit alignment" method using 3D analysis software. Statistical analysis was performed using the independent t-test and 2-way ANOVA (α=.05). Results: The RMS value of the 3D printed die model was significantly larger than the RMS value of the stone die model (P<.001). As a result of 2-way ANOVA, significant differences were found between the model group (P<.001) and the part (P<.001), and their interaction effects (P<.001). Conclusion: The 3D printed die model showed lower accuracy than the stone die model. Therefore, it is necessary to further improve the performance of 3D printer in order to apply the 3D printed model in prosthodontics.

Accuracy evaluation of dental models manufactured by CAD/CAM milling method and 3D printing method

  • Jeong, Yoo-Geum;Lee, Wan-Sun;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.3
    • /
    • pp.245-251
    • /
    • 2018
  • PURPOSE. To evaluate the accuracy of a model made using the computer-aided design/computer-aided manufacture (CAD/CAM) milling method and 3D printing method and to confirm its applicability as a work model for dental prosthesis production. MATERIALS AND METHODS. First, a natural tooth model (ANA-4, Frasaco, Germany) was scanned using an oral scanner. The obtained scan data were then used as a CAD reference model (CRM), to produce a total of 10 models each, either using the milling method or the 3D printing method. The 20 models were then scanned using a desktop scanner and the CAD test model was formed. The accuracy of the two groups was compared using dedicated software to calculate the root mean square (RMS) value after superimposing CRM and CAD test model (CTM). RESULTS. The RMS value ($152{\pm}52{\mu}m$) of the model manufactured by the milling method was significantly higher than the RMS value ($52{\pm}9{\mu}m$) of the model produced by the 3D printing method. CONCLUSION. The accuracy of the 3D printing method is superior to that of the milling method, but at present, both methods are limited in their application as a work model for prosthesis manufacture.

Comparative analysis on reproducibility among 5 intraoral scanners: sectional analysis according to restoration type and preparation outline form

  • Park, Ji-Man
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.5
    • /
    • pp.354-362
    • /
    • 2016
  • PURPOSE. The trueness and precision of acquired images of intraoral digital scanners could be influenced by restoration type, preparation outline form, scanning technology and the application of power. The aim of this study is to perform the comparative evaluation of the 3-dimensional reproducibility of intraoral scanners (IOSs). MATERIALS AND METHODS. The phantom containing five prepared teeth was scanned by the reference scanner (Dental Wings) and 5 test IOSs (E4D dentist, Fastscan, iTero, Trios and Zfx Intrascan). The acquired images of the scanner groups were compared with the image from the reference scanner (trueness) and within each scanner groups (precision). Statistical analysis was performed using independent two-samples t-test and analysis of variance (${\alpha}=.05$). RESULTS. The average deviations of trueness and precision of Fastscan, iTero and Trios were significantly lower than the other scanners. According to the restoration type, significantly higher trueness was observed in crown and inlay than in bridge. However, no significant difference was observed among four sites of preparation outline form. If compared by the characteristics of IOS, high trueness was observed in the group adopting the active triangulation and using powder. However, there was no significant difference between the still image acquisition and video acquisition groups. CONCLUSION. Except for two intraoral scanners, Fastscan, iTero and Trios displayed comparable levels of trueness and precision values in tested phantom model. Difference in trueness was observed depending on the restoration type, the preparation outline form and characteristics of IOS, which should be taken into consideration when the intraoral scanning data are utilized.

Evaluation of Geometric Error Sources for Terrestrial Laser Scanner

  • Lee, Ji Sang;Hong, Seung Hwan;Park, Il Suk;Cho, Hyoung Sig;Sohn, Hong Gyoo
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.24 no.2
    • /
    • pp.79-87
    • /
    • 2016
  • As 3D geospatial information is demanded, terrestrial laser scanners which can obtain 3D model of objects have been applied in various fields such as Building Information Modeling (BIM), structural analysis, and disaster management. To acquire precise data, performance evaluation of a terrestrial laser scanner must be conducted. While existing 3D surveying equipment like a total station has a standard method for performance evaluation, a terrestrial laser scanner evaluation technique for users is not established. This paper categorizes and analyzes error sources which generally occur in terrestrial laser scanning. In addition to the prior researches about categorizing error sources of terrestrial Laser scanning, this paper evaluates the error sources by the actual field tests for the smooth in-situ applications.The error factors in terrestrial laser scanning are categorized into interior error caused by mechanical errors in a terrestrial laser scanner and exterior errors affected by scanning geometry and target property. Each error sources were evaluated by simulation and actual experiments. The 3D coordinates of observed target can be distortedby the biases in distance and rotation measurement in scanning system. In particular, the exterior factors caused significant geometric errors in observed point cloud. The noise points can be generated by steep incidence angle, mixed-pixel and crosstalk. In using terrestrial laser scanner, elaborate scanning plan and proper post processing are required to obtain valid and accurate 3D spatial information.