수직형 건식 진공 스크류 펌프의 열특성에 대한 연구 (A Study on the Thermal Characteristics of Dry Vacuum Pump with Vertical Screws)

  • 장문석;박재현;김수태;김일곤;조성진
    • 한국기계가공학회지
    • /
    • 제14권2호
    • /
    • pp.67-74
    • /
    • 2015
  • In this study, analysis and experiments were carried out on temperature distributions and thermal deformations in a dry vacuum pump with vertical screws for safe operation. When a vacuum pump is working, it is necessary to get rid of the heat generated by the friction of bearings and the compression of air to prevent the vacuum pump from being damaged by interference between two screws and housing through thermal deformation. Additional cooling was proposed by using oil flow through the inner channel of the rotating axis for lower temperature control of the vacuum pump. Analysis and experimental results were compared in terms of temperature distribution and thermal deformation of the vacuum pump, and two sets of results matched reasonably well. These results for a dry vacuum pump with vertical screws can be used in similar model development and can minimize errors in design and manufacture by providing reasonably accurate prediction in advance.

PIV에 의한 흡입수조내 흡입관 주위의 유동특성에 관한 연구 (A Study on the Flow Characteristics around Intakes within a Sump by PIV)

  • 최종웅;김정환;김경엽;김유택;이영호
    • 한국유체기계학회 논문집
    • /
    • 제5권3호
    • /
    • pp.33-39
    • /
    • 2002
  • The head-capacity corves for pumps developed by the pump manufacturer are based on tests of a single pump operating in a semi-infinite pool with no nearby walls or floors and with no stray currents. Hence, flow into the pump suction is symmetrical with no vortices or swirling. Pump station designers rely on these curves to define the operating conditions for the pump selected. However, various constraints such as size, cost, and limitations on storage time require walls, floors, and pump intakes to be close proximity to each other. From this background, the authors are carrying out a systematic study on the flow characteristics of intakes within a sump found in pump stations. Model pump intake basin is designed and PIV is adopted as a measuring tool to capture the instantaneous flow patterns. Special attention is paid to investigate the flow patterns near the free surface, side-wall, and back-wall due to different clearances from back-wall to vortical intake pipe. Moreover, the locations and patterns of the various types of vortices that were found in the examinations are discussed.

루츠식 진공 펌프의 유동 및 부산물 입자 궤적에 대한 해석 (Analysis on the Flow and the Byproduct Particle Trajectory of Roots Type Vacuum Pump)

  • 이찬;길현권;노명근
    • 한국유체기계학회 논문집
    • /
    • 제14권5호
    • /
    • pp.18-23
    • /
    • 2011
  • A CFD analysis method is developed and applied for investigating the gas flow and the byproduct particle trajectory in Roots type vacuum pump. The internal fluid flow and thermal fields between the rotors and the housing of vacuum pump are analyzed by using the dynamic mesh, the numerical methods for unsteady 2-D Navier-Stokes equation and the standard k-$\varepsilon$ turbulence model of the Fluent code. Coupled with the flow simulation results, the particle trajectory of the byproduct flowing into the pump with gas stream is analyzed by using discrete phase modeling technique. The CFD analysis results show the pressure, the velocity and the temperature distributions in pump change abruptly due to the rotation of rotors, and back flows are produced due to the strong reverse pressure gradients at rotor/rotor and rotor/housing clearances. The predicted byproduct particle trajectory results also show the particles impinge on the clearance surfaces between the housing and the rotor of pump and then may form the deposit layer causing the failure of pump.

PIV에 의한 흡입수조내 흡입관 주위의 유동특성에 관한 연구 (Study on Flow Characteristics around Intakes within a Sump by PIV)

  • 최종웅;김정환;남청도;김유택;이영호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.563-569
    • /
    • 2001
  • The head-capacity curves for pumps developed by the pump manufacturer are based on tests of a single pump operating in a semi-infinite pool with no nearby walls or floors and no stray currents, Hence, flow into the pump suction is symmetrical with no vortices or swirling. Pump station designers rely on these curves to define the operating conditions for the pump selected. But various constraints such as size, cost, and limitations on storage time require walls, floors, and pump intakes to be close proximity to each other. From this background, the authors are carrying out a systematic study on the flow characteristics of intakes within a sump found in pump stations. Model pump intake basin is designed and PIV is adopted as a measuring tool to capture the instantaneous flow patterns. Special attention is paid to investigate the flow patterns near the free surface, side-wall and back-wall due to different clearances from back-wall to vertical in take pipe. Moreover, the locations and vorticities of the various types of vortices that were found in the examinations are discussed.

  • PDF

고압 터보펌프용 연료펌프의 수력설계 및 성능 평가 (Hydraulic Design and Performance Evaluation of a Fuel Pump for a High Pressure Turbopump System)

  • 최범석;윤의수;오형우
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.341-346
    • /
    • 2004
  • A low NPSH and high pressure fuel pump has been designed for a turbopump system. The fuel pump has an axial inducer and a centrifugal impeller. A meanline method has been established for the preliminary design and performance prediction of pumps at design or off-design points. KeRC carried out a model testing of the fuel pump with water as a working fluid at the reduced speed. Predicted performances by the method are shown to be in good agreement with experimental results for cavitating and non-cavitating conditions. The established meanline method can be used for the performance prediction and preliminary design of high speed pumps which have a inducer, impeller and volute. In the current study, the three dimensional viscous flow in the fuel pump was investigated through numerical computation. A modified design of the fuel pun was generated to improve pump performance by utilizing CFD results. The modified fuel pump was experimentally tested by ROTEM and KARI. The measured non-cavitating and cavitating performance showed a good agreement with designed performance.

  • PDF

가스인젝션을 적용한 이산화탄소 열펌프의 난방성능 향상에 관한 해석적 연구 (Analytical Study on the Heating Performance Improvement of a CO2 Heat Pump Using Vapor Injection)

  • 정종호;백창현;허재혁;김용찬
    • 설비공학논문집
    • /
    • 제24권11호
    • /
    • pp.767-776
    • /
    • 2012
  • In this study, a simulation model for a $CO_2$ heat pump using vapor injection was developed and validated. It was used to predict the improvement of the heating performance of the $CO_2$ heat pump at various operating conditions. The simulation results showed consistent results with the measured data. The heating performances of the vapor injection and non-injection heat pumps were compared by varying the outdoor temperature and compressor frequency. The heating capacity of the vapor injection heat pump was 40% higher than that of the non-injection heat pump at the outdoor temperature of $-8^{\circ}C$. The performance of the vapor injection heat pump was consistently higher than that of the non-injection heat pump even when the compressor frequency was reduced to 35 Hz at the outdoor temperature of $-3^{\circ}C$.

차륜형 장갑차용 가변형 사판식 피스톤 펌프 케이스의 구조해석 및 설계검증에 관한 연구 (A Study on the Structural Analysis and Design Verification of Variable Swash Plate Piston Pump Case for Wheeled Armored Vehicle)

  • 최성웅;김용석;양순용
    • 드라이브 ㆍ 컨트롤
    • /
    • 제16권2호
    • /
    • pp.43-50
    • /
    • 2019
  • The objective of this study was to reverse engineer a swash plate type piston pump mounted on a wheeled armored vehicle and to analyze the structure of the pump case. From the analysis, the weak parts were identified and corrected in the final design. Each element corresponding to the piston pump case was analyzed. The analytical method was given static boundary conditions, load conditions and confirmed displacement, strain, stress, and safety factor. Plastic deformation and damage were also confirmed and the component elements redesigned through structural analysis Structural analysis and vibration analysis were carried out for the components of the piston pump case. The piston pump model was finally modified by structural analysis and vibration analysis results for each component assembly, and a prototype was designed. Durability test and environmental test were carried out and the test results satisfied all of the requirements. Therefore, the analytical method presented in this study can be utilized as a methodology for element component design in the development of various piston pumps.

주요 성능변수를 근거한 단일채널펌프 설계기술 (Advanced Design Technique for a Single-Channel Pump Based on the Main Performance Parameters)

  • 김성;최영석;김진혁
    • 한국수소및신에너지학회논문집
    • /
    • 제30권5호
    • /
    • pp.448-454
    • /
    • 2019
  • This paper presents a high-efficiency design technique for developing the serialized models of a single-channel pump based on the diameter, flow rate and head as the main performance parameters. The variation in pump performance by changing of the single-channel pump geometry was predicted based on computational fluid dynamics (CFD). Numerical analysis was conducted by solving three-dimensional steady Reynolds-averaged Navier-Stokes equations with the shear stress transport (SST) turbulence model. The tendencies of the hydraulic performance depending on the pump geometry scale were analyzed with the fixed rotational speed. These performances were expressed and evaluated as the functionalization for designing the serialized models of a single-channel pump in this work.

Research on non-uniform pressure pulsation of the diffuser in a nuclear reactor coolant pump

  • Zhou, Qiang;Li, Hongkun;Pei, Lin;Zhong, Zuowen
    • Nuclear Engineering and Technology
    • /
    • 제53권3호
    • /
    • pp.1020-1028
    • /
    • 2021
  • The nuclear reactor coolant pump transferring heat energy inherently brings with it the unsteady flow and inevitably threatens to the safe operation of the pump unit, especially with the pressure pulsation induced by the rotor-stator interaction. In this paper, the characteristics of pressure pulsation of the diffuser in a nuclear reactor coolant pump were investigated by the numerical simulation with experimental validation. Pressure pulsation signals measured synchronously from sensors mounted on the radial diffuser of a model pump were analyzed via Welch's method. Frequency components induced by the rotor-stator interaction can be revealed by the diameter mode analysis method. The pressure pulsation of the diffuser is dominated by the blade passing frequency and its harmonics, which are free from the effect of flow rate and rotational speed while the corresponding amplitudes are easily affected by different operational conditions and measuring positions. The non-uniformity is much more affected by the rotational speed than the flow rate. This research is helpful for further work to reduce the pressure pulsation for the reactor coolant pump.

CFD해석기법을 적용한 다단펌프 성능향상에 관한 연구 (A Study on Performance Improvement of Multi-stage Pump Applying CFD Analysis Technique)

  • 김상유;김재열;고가진
    • 한국기계가공학회지
    • /
    • 제21권3호
    • /
    • pp.70-76
    • /
    • 2022
  • Recently, the demand for ultra-precision processing has increased owing to the increase in the demand for high-performance ultra-precision optical parts in the fields of information technology (IT), bio, healthcare, aerospace, and future automobiles. In this study, a performance improvement of a multi-stage pump was achieved by improving the pump casing structure rather than using the existing performance improvement method. To verify the performance improvement, the CFD analysis reliability of the existing pump, Pump A, was verified using the FLUENT app in the analysis software ANSYS, and the pump casing was improved through the verified CFD analysis of Pump B. Therefore, we want to analyze the performance improvement.