• Title/Summary/Keyword: Model Tests

Search Result 7,132, Processing Time 0.037 seconds

Characteristics of Carbonaceous Particles Derived from Coal-fired Power Plant and Their Reduction (석탄 화력발전소에서 발생하는 미연분의 특성분석 및 저감방법)

  • Park, Ho-Young;Kim, Young-Ju;Yu, Geun-Sil;Kim, Chun-Kun;Kim, Dong-Hun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.10
    • /
    • pp.1065-1073
    • /
    • 2006
  • The unturned carbon in fly ash, recently occurred in the coal-fired Yong Hung power station, caused some problems in ash utilization and boiler efficiency. This paper describes the analysis of unburned carbon and six coals, some tests performed at Yong Hung Boiler, and the results of combustion modification for the reduction of unburned carbon in fly ash. From the physical and chemical analysis of unburned carbon in fly ash, most particles were turned out to be hollow cenosphere and agglomerated soot particles. The sooting potential from six coals used in the plant were investigated with CPD(Chemical Percolation Devolatilization) model. The results showed that the higher potential was presented to Peabody, Arthur, Shenhua coals rather than other coals. It was necessary to measure the coal flow rates at each coal feeding pipe for four burner levels since they affect the extent of mixing of soot with oxidant, in turn, the oxidation rate of soot particles. The unbalance in coal flow rate was found in several coal pipes. We successfully reduced unturned carbon in ash by increasing the excess air and changing the SOFA's yaw angle.

In vitro comparison of measurement accuracy In pre-enlarged and enlarged canals with four apex locators (근관 성형 전후의 네 가지 전자근관장측정기의 측정 정확성의 비교)

  • Sung, Sang-Yup;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.5
    • /
    • pp.371-377
    • /
    • 2006
  • The purposes of this study were to assess the accuracy of measurements in pre-enlarged canals with small instruments and to compare the accuracies, in enlarged canal, with small size instruments and instruments that match the actual canal diameter using Root ZX, Bingo1020, SmarPex, and e-Magic Finder. Ten extracted teeth were embedded in an alginate model made for testing apex locators. A size 10 file was placed into the root canal until the tip of the file reached the plane of the major diameter of the foramen under a dental operating microscope at the 25 x magnification. The measurement was done with digital caliper and defined as actual length. Electronic length measurement with a size 10 file in pre-enlarged canal was done by reading the index indicating Apex of each device to gain a definite value After completion of canal enlargement to a size 45 file, each difference between actual length and electric measurement value with a size 10 and 40 files in enlarged canal was recorded as L10 and L40. The one-way ANOVA and Scheffe's multiple range tests were computed for analyze the differences among the four apex locators in the same group. The Student's t-test between L10 and L40 of each locator was done. The accuracies of electronic measurements were significantly different among the 4 devices. The file size made no difference on the accuracy of electronic measurement in enlarged canal with same device. The e-Magic Finder was the most accurate device among the 4 apex locators used in this study.

Systematic Review : Comparative Safety and Efficacy of Mono- and Combination Therapy of Anti-hypertensive Agents Acting on the Renin-Angiotensin System (레닌-안지오텐신계에 작용하는 항고혈압 약제의 단독요법과 병용요법의 안전성 및 유효성에 대한 체계적 문헌고찰)

  • Choi, Kyung-Eob;Kim, Hyun-Kyung
    • Korean Journal of Clinical Pharmacy
    • /
    • v.21 no.4
    • /
    • pp.364-375
    • /
    • 2011
  • Given that single blockade with angiotensin-converting enzyme inhibitors (ACEIs) or angiotensin receptor blockers (ARBs) can achieve only partial and undurable suppression of the Renin Angiotensin System (RAS), it has been hypothesized that dual blockage would be more beneficial in the management of blood pressure (BP) reduction and prevention of progressive chronic kidney disease (CKD) than either agent alone. Thus, it has been suggested that the combination of an ACEI and an ARB might provide renal benefits to hypertensive patients over and above BP reduction. However, this might also expose patients to additive or synergistic side effects. We attempted to conduct a systematic review to evaluate the benefits and harms of combination therapy in hypertensive patients with or without kidney diseases. MEDLINE and KoreaMed were searched for relevant randomized clinical trials in adult hypertensive patients with or without diabetes (restricted to 1997, limited to trials published in English). Results were summarized using the random-effects model, and between-studies heterogeneity was estimated with $I^2$. A final analysis of ten trials (23,928 patients) revealed that the combination of an ACEI and an ARB reduced blood pressure (SBP/DBP) by 3.95/2.02 mmHg (95% confidence interval [CI], -4.38 to -3.53/-2.33 to -1.71) compared with ACEI monotherapy, and 2.83/2.64 mmHg (95% CI, -3.25 to -2.41/-4.95 to -0.33) compared with ARB monotherapy. Eight trials (391 patients) demonstrated a significant reduction in 24h-proteinuria (weighted mean difference, 0.16 g/day, 95% CI, -0.26-0.05), but they did not translate into an improvement in GFR. Tests for heterogeneity showed no difference in effect among the studies. The combination therapy reduced proteinuria by 30% (95% CI, 23% to 37%) and 39% (95% CI, 31% to 48%) compared with ACEI monotherapy and ARB monotherapy, respectively. However, in patients who had proteinuria more than 0.5 g/day, the combination therapy failed to show significant reduction in urinary protein excretion. The current cumulative evidence suggests that diabetic patients with proteinuria on dual RAS blockade have an increase risk of adverse events such as hyperkalemia, hypotension, and so on, compared with ACEI or ARB alone. It is, therefore, proposed that the combination therapy should not be routinely used for the treatment of hypertension with or without compelling indications.

Evaluation on Mechanical Properties of High Strength Light-Weight Concrete with Elevated Temperature and loading (하중조건과 고온에 의한 고강도 경량 콘크리트의 역학적 특성 평가)

  • Kim, Gyu-Yong;Kim, Young-Sun;Choe, Gyeong-Cheol;Park, Hyun-Gil;Lee, Tae-Gyu
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.6
    • /
    • pp.723-730
    • /
    • 2011
  • It is very important to experimentally evaluate concrete behavior at elevated temperature because aggregates make up approximately 80 percent of volume in concrete. In this study, an experiment to evaluate mechanical properties of normal weight and light weight concrete of 60 MPa was conducted. Based on loading level of 0, 20 and 40 percent, the tests of 28 days compressive strength, elastic modulus, thermal strain, total strain, and transient creep using ${\phi}100{\times}200mm$ cylindrical specimens at elevated temperature were performed. Then, the results were compared with CEB (Committes Euro-international du Beton) model code. The results showed that thermal strain of light weight concrete was smaller than normal weight concrete. Also, the results showed that compressive strength of light concrete at $700^{\circ}C$ was higher than normal weight concrete and CEB code, similar to that obtained at ambient temperature. Transient creep developed from loading at a critical temperature of $500^{\circ}C$ caused the concrete strains to change from expansion to compression. The transient creep test result showed that internal force was high when the ratio of shrinkage between concrete and aggregate was more influential than thermal expansion.

A study on the relationship between the onshore and offshore Chinese Yuan markets (중국 역내·외 위안화 현물시장간의 상호 연계성 연구)

  • Lee, Woosik;Chun, Heuiju
    • Journal of the Korean Data and Information Science Society
    • /
    • v.26 no.6
    • /
    • pp.1387-1395
    • /
    • 2015
  • Since the financial crisis of 2008, the People's Republic of China has aggressively been pursuing the internationalization of the Chinese Yuan or Renminbi. In this regard, rapidly increasing use of the Chinese Yuan in the onshore and offshore markets are important milestones. This paper analyzes relationship between the onshore and offshore Chinese Yuan spot markets. Major findings of this paper are as follows : First, there is full feedback relationship between the Onshore and Offshore Chinese Yuan Markets. Second, the difference between the yuan's offshore exchange rate and the onshore was getting tight. Third, the offshore Yuan market affects on the onshore market based on the empirical tests.

Effect of Suprabulge Clasp and Infrabulge Clasp on the Mobility of Abutment Teeth for Distal Extension Removable Partial Dentures (유리단 국소의치에서 Suprabulge Clasp와 Infrabulge Clasp가 지대치 동요에 미치는 영향에 관한 연구)

  • Yim, Soon-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.19 no.1
    • /
    • pp.39-45
    • /
    • 1981
  • Distal-extension removable partial dentures have long been implicated in the increase in mobility and the destruction of the supporting structures of the primary abutment teeth. Various clasping systems have traditionally been used to retain distal extension removable partial dentures, and other designs have been proposed to minimize torquing forces on the abutment teeth. Most recent studies investigating the effects of removable partial dentures on abutment teeth have been performed in it laboratory setting. Results obtained from in vitro research have given dentists insight into removable partial denture design, but laboratory test model cannot be constructed that simulates actual functional or parafunctiona1 movements and forces. The purpose of this study was to clinically evaluate the degree of tooth mobility produced by two clasping systems (suprabulge type and infrabulge type) used for distal extension removable partial dentures. Akers clasp and R.P.I. system were selected for the evaluation, and four patients required a distal extension removable partial denture on the mandibular arch were selected for participation in the study. Two partial dentures were constructed in the same condition expect the design of clasp. All abutments in the study were mandibular first or second premolars. Measurements of mobility were made with a research tool designed by $M\"{u}hlemann$. This instrument, periodontometer, measures tooth mobility in the mouth by means of a dial gauge accurated to 0.01mm when the tooth is stressed with a force meter. Lingual and buccal deflection of abutment tooth was measured using buccal and lingual pressure. The amount of force applied was 500gm. Tooth mobility tests were made at four key stages; 1. Before insertion of the first removable partial denture, baseline mobility was establsihed. 2. After wearing of the first prosthesis, measurement was made at weekly intervals for 4 weeks. 3. The removable partial denture was then taken from the patient, and tooth mobility was measured again at weekly intervals until the patient's established baseline mobility had returned. 4. The second prosthesis of different clasp design was worn for a month and evaluated in the same manner as the first. The sequence of placement of clasping system was alternated between patients. The following results were obtained from this study; 1. The mobility of abutment tooth increased during the initial stage of wear and returned to baseline mobility after removal of removable partial dentures. 2. The mobility of abutment tooth showed no difference between Akers clasp and I-bar clasp during the 4-week test period. 3. All teeth tested showed greater mobility toward the buccal than the lingual direction.

  • PDF

Drying time of tray adhesive for adequate tensile bond strength between polyvinylsiloxane impression and tray resin material

  • Yi, Myong-Hee;Shim, Joon-Sung;Lee, Keun-Woo;Chung, Moon-Kyu
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.2
    • /
    • pp.63-67
    • /
    • 2009
  • STATEMENT OF PROBLEM. Use of custom tray and tray adhesive is clinically recommended for elastomeric impression material. However there is not clear mention of drying time of tray adhesive in achieving appropriate bonding strength of tray material and impression material. PURPOSE. This study is to investigate an appropriate drying time of tray adhesives by evaluating tensile bonding strength between two types of polyvinylsiloxane impression materials and resin tray, according to various drying time intervals of tray adhesives, and with different manufacturing company combination of impression material and tray adhesive. MATERIAL AND METHODS. Adhesives used in this study were Silfix (Dentsply Caulk, Milford, Del, USA) and VPS Tray Adhesive (3M ESPE, Seefeld, Germany) and impression materials were Aquasil Ultra (monophase regular set, Dentsply Caulk, Milford, Del, USA) and Imprint II Garant (regular body, 3M ESPE, Seefeld, Germany). They were used combinations from the same manufacture and exchanged combinations of the two. The drying time was designed to air dry, 5 minutes, 10 minutes, 15 minutes, 20 minutes, and 25 minutes. Total 240 of test specimens were prepared by auto-polymerizing tray material(Instant Tray Mix, Lang, Wheeling, Il, USA) with 10 specimens in each group. The specimens were placed in the Universal Testing machine (Instron, model 3366, Instron Corp, University avenue, Nowood, MA, USA) to perform the tensile test (cross head speed 5 mm/min). The statistically efficient drying time was evaluated through ANOVA and Scheffe test. All the tests were performed at 95% confidence level. RESULTS. The results revealed that at least 10 minutes is needed for Silfix-Aquasil, and 15 minutes for VPS Tray Adhesive-Imprint II, to attain an appropriate tensile bonding strength. VPS Tray Adhesive-Imprint II had a superior tensile bonding strength when compared to Silfix-Aquasil over 15 minutes. Silfix-Aquasil had a superior bonding strength to VPS Tray Adhesive-Aquasil, and VPS Tray Adhesive-Imprint II had a superior tensile bonding strength to Silfix-Imprint II at all drying periods. CONCLUSION. Significant increase in tensile bonding strength with Silfix-Aquasil and VPS Tray adhesive-Imprint II combination until 10 and 15 minutes respectively. Tray adhesive-impression material combination from the same company presented higher tensile bonding strength at all drying time intervals than when using tray adhesive-impression material of different manufactures.

Comparison of Dental Age and Skeletal Maturity in Korean Children with Skeletal Malocclusion (한국 어린이의 골격적 부정교합에 따른 골 성숙도와 치아의 성숙도 비교)

  • Kim, Jeeyoun;Oh, Sohee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.41 no.3
    • /
    • pp.225-232
    • /
    • 2014
  • The purpose of this study was to compare skeletal maturity index and dental developmental stages based on skeletal malocclusion. A total of 192 patients (89 male and 103 female) between 6 to 14 years old were selected for this study and underwent cephalograms, panorama radiographs, and hand-wrist radiographs. Any syndromic cases were excluded. Selected clinical parameters were dichotomised for statistical analysis. Chi-square, logistic regression analysis, and independent t-tests were used for the statistical evaluation. Canine, first molar, and second molar calcification were significantly associated with skeletal maturity in the logistic regression model (p < 0.05). In addition, patients who had higher skeletal maturity index were 11.43 times more likely to be female than those who had lower skeletal maturity index (p < 0.001). The patients with skeletal class II malocclusion displayed significantly higher dental developmental stage in canines, first premolars, first molars, and second molars than the patients with class III malocclusion (p < 0.05). The dental developmental stage of the patients was significantly associated with skeletal maturity. In addition, there was a significant difference between class II and class III malocclusion with some types of tooth calcification.

Analyzing Korean Pre-service Biology Teachers' Understanding of the Concept of Natural Selection in Comparison with Chinese, American, and German Biology Majors (중국, 미국, 독일의 생물전공자와 비교한 한국 생물예비교사의 자연선택개념 이해 수준 분석)

  • Ha, Minsu
    • Journal of The Korean Association For Science Education
    • /
    • v.36 no.5
    • /
    • pp.729-737
    • /
    • 2016
  • Natural selection is the core idea of evolution that pre-service biology teachers need to understand to solve diverse biological problem. This study aims to investigate the level of Korean pre-service biology teachers' understanding of natural selection by comparing their knowledge with their Chinese, American, and German biology major undergraduate counterparts. In particular, this study focuses on two conceptual components of natural selection (i.e., ecology and genetics). This study used a total 1226 pre-service biology teachers and biology majors' data. The instrument measuring the understanding of natural selection concepts was Conceptual Inventory of Natural Selection, which consists of ten ecology concept items and ten genetics concept items. The Rasch model analysis, multivariate analysis of variance, and univariate analysis of variance were used for the statistical tests. The result reveals that the level of Korean pre-service biology teachers' understanding of natural selection were similar with Chinese undergraduates' understanding and significantly lower than American and German undergraduates.' In the first year student data, the level of genetics concept of Korean pre-service biology teachers were significantly lower than Chinese and German students. In the fourth year student data, the level of ecology concept of Korean pre-service biology teachers were significantly lower than American and German students. Based on these results, the ecology concept education and balanced natural selection concept education are discussed.

An Experimental Study for Substitutability of Sand Mat with Fiber Mat (Fiber Mat의 Sand Mat 대체가능성평가를 위한 실험적 연구)

  • Lee Song;Jeong Yong-Eun
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.5
    • /
    • pp.225-230
    • /
    • 2005
  • At present, there are several problems related with sand mat which is used as a way to accelerate consolidation settlement, to act like an underground drainage layer and to increase trafficability simultaneously. First of all, the unbalance of the demand and supply of sand is one of the biggest problems, which causes not only price rise but also delay of the term of the total construction work. Secondly, the damage of ecosystem and scenery is triggered by thoughtless sand dredging or mining. So, the need that sand mat should be replaced with a new environmentally friendly material has been increased. Fiber mat may be one of the proper materials that suits the need. Therefore, we intended to compare the drainage properties of sand mat with those of fiber mat by experimental model tests. On the basis of the test results, fiber mat took shorter period of consolidation than sand mat and the amount of settlement in the farmer showed a little bit bigger than in the latter. As a conclusion, the substitutability of sand mat with fiber mat could be placed highly in view of drainage efficiency. Furthermore, when fiber mat is used, it has an advantage that spoiled soil of the construction site or nearby site can be used for the purpose of increasing trafficability in addition to a role of drainage layer.