• Title/Summary/Keyword: Model Power Line

Search Result 822, Processing Time 0.03 seconds

Transformer Winding Modeling based on Multi-Conductor Transmission Line Model for Partial Discharge Study

  • Hosseini, Seyed Mohammad Hassan;Baravati, Peyman Rezaei
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.154-161
    • /
    • 2014
  • To study and locate partial discharge(PD) and analyze the transient state of power transformer, there is a need for a high frequency model of transformer winding and calculation of its parameters. Due to the high frequency nature of partial discharge phenomenon, there is a need for an accurate model for this frequency range. To attain this goal, a Multi-Conductor Transmission Line (MTL) model is used in this paper for modeling this transformer winding. In order that the MTL model can properly simulate the transformer behavior within a frequency range it is required that its parameters be accurately calculated. In this paper, all the basic parameters of this model are calculated by the use of Finite Element Method (FEM) for a 20kV winding of a distribution transformer. The comparison of the results obtained from this model with the obtained shape of the waves by the application of PD pulse to the winding in laboratory environment shows the validity and accuracy of this model.

MIMO-OFDM BPLC over Statistical Power Line Channels with Cross-Talk (크로스 토크를 갖는 통계적 전력선 채널 하에 MIMO-OFDM 광대역 전력선 통신)

  • Yoo, Jeong-Hwa;Choe, Sang-Ho;Pine, Nazcar
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.12B
    • /
    • pp.1565-1573
    • /
    • 2011
  • In this paper, we present a MIMO-OFDM broadband power line communication (BPLC) for Smart Grid and its associated applications and analyze its performance over the 3-phase 4-wire power line channels. For practical BPLC system simulation, we adopt the statistical power line fading channel model instead of the existing deterministic fading channel models (Zimmermann model, MTL model, and so on). In this paper, we implement $2{\times}2$ and $3{\times}3$ MIMO schemes using 3-phase 4-wire power lines. We investigate the capacity loss and BER performance of the proposed MIMO system by considering the effect of cross-talk between antenna paths. We choose space-frequency coding in order to reduce frequency interference between subcarriers and employ maximum ratio combining (MRC) that achieves both multiple antenna path diversity gain and multiple fading path diversity gain. We evaluate the proposed system performance through computer simulation in terms of the impulse noise index and the capacity loss ratio and compare the different signal combining schemes including MRC, equal gain combing (EGC), and selection combining (SC).

Development and Application of Overhead Transmission Line Design Program Using High Spatial Resolution Satellite Imagery (고해상도 위성영상을 이용한 송전선로 경과지 설계 프로그램 개발 및 활용)

  • Lee, Hee-Seon;Park, Byoung-Won
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.27-29
    • /
    • 2005
  • Overhead transmission line design supporting program using high spatial resolution satellite imagery has been developed recently by Korea Power Engineering Company, The developed program, ITSS(Interactive Tower Spotting System) is purposed to improve the application of satellite imagery with the route selection of overhead transmission line. It is composed of spotting the tower position and designing the tower type and height with DEM(Digital Elevation Model) overlaid with satellite Imagery. To review and confirm the function and work efficiency, ITSS was applied to the pilot project of overhead transmission line design.

  • PDF

The Simulation Implementation on contact loss of high speed electric railway using a Power Line Disturbance simulator (전원외란 시뮬레이터를 이용한 고속전철 이선현상 모의 실험)

  • Kim, Jae-Moon;Kim, Yang-Soo;Chang, Chin-Young;Ahn, Jeong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2152_2153
    • /
    • 2009
  • In this study, the dynamic characteristic of a contact wire and pantograph suppling electrical power to high-speed trains are investigated from an electrical response point of view. To analysis power line disturbance by induced contact loss phenomenon for high speed operation, a hardware Simulator which considered contact loss between contact wire and the pantograph as well as contact wire deviation is developed. It is confirmed that a contact wire and pantograph model are necessary for studying the dynamic behavior of the pantograph system. One of the most important needs accompanied by increasing the speed of high-speed train is reduced that an arc phenomenon by loss of contact brings out EMI. In case of a high-speed train using electrical power, as comparison with diesel rolling stock, PLD(Power Line Disturbance) such as harmonic, transient voltage and current, EMI, dummy signal injection etc usually occurs. Throughout experiment, it is verified that an arc phenomenon is brought out for simulator operation and consequently conducted noise is flowed in electric circuit by power line disturbance.

  • PDF

Double Line Voltage Synthesis Strategy for Three-to-Five Phase Direct Matrix Converters

  • Wang, Rutian;Zhao, Yanfeng;Mu, Xingjun;Wang, Weiquan
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.81-91
    • /
    • 2018
  • This paper proposes a double line voltage synthesis (DLVS) strategy for three-to-five phase direct matrix converters. In the proposed strategy, the input and expected output voltages are divided into 6 segments and 10 segments, respectively. In addition, in order to obtain the maximum voltage transfer ratio (VTR), the input line voltages and "source key" should be selected reasonably according to different combinations of input and output segments. Then, the corresponding duty ratios are calculated to determine the switch sequences in different segment combinations. The output voltages and currents are still sinusoidal and symmetrical with little lower order harmonics under unbalanced or distorted input voltages by using this strategy. In addition, the common mode voltage (CMV) can be suppressed by rearranging some of the switching states. This strategy is analyzed and studied by a simulation model established in MATLAB/Simulink and an experimental platform, which is controlled by a DSP and FPGA. Simulation and experimental results verify the feasibility and validity of the proposed DLVS strategy.

Fuzzy Based Approach for the Safety Assessment of Human Body under ELF EM field Considering Power System States

  • Kim, Sang C.;Kim, Doo H.
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1997.11a
    • /
    • pp.117-122
    • /
    • 1997
  • This paper presents a study on the fuzzy based approach for the safety assessment of human body under ELF electric and magnetic(EM) field considering power system states. The analysis of ELF EM field based on quasi-static method is introduced. UP to the present, the analysis of ELF EM field has been conducted with the consideration of one transmission line, or a power line model only In this paper, however, the power system is included to model the expected and/or unexpected uncertainty caused by the load fluctuation and parameter changes and the states are classified into two types, normal state resulting from normal operation and emergency state from outages. In order to analyze the uncertainty in the normal state, the Monte Carlo Simulation, a statistic approach was introduced and line current and bus voltage distribution are calculated by a contingency analysis method, in the emergency state. To access the safety of human body, the approach based on fuzzy linguistic variable is adopted to overcome the shortcomings of the assessment by a crisp set concept. In order to validate the usefulness of the approach suggested herein, the case study using a sample system with 765(kV) was done. The results are presented and discussed.

  • PDF

Numerical Study on the Thermal Model of High Power Density Welding (고에너지 밀도용접의 온도특성에 관한 수치해석적 연구)

  • 이성호;고상근
    • Journal of Welding and Joining
    • /
    • v.10 no.2
    • /
    • pp.19-31
    • /
    • 1992
  • A numerical study was performed to investigate the flow field and the heat transfer characteristics occurring in high power density welding which is important in many fields of engineering applications. A two dimensional quasi-steady state of keyhole welding model is simulated by using the finite volume methods. It is shown that the shape of isothermal line is elliptic and the temperature gradient is very steep compared with other welding method and the welding speed has on welding width and observed beam power.

  • PDF

Force Control of a Pneumatic Driving System With a Long Transmission Line (전달관로를 고려한 공기압 구동장치의 힘 제어에 관한 연구)

  • Jang, J.S.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.8 no.3
    • /
    • pp.8-13
    • /
    • 2011
  • In the present study, a robust controller has been designed to control force for a pneumatic driving system considering the effect of a transmission line. Transfer characteristics of pneumatic transmission line should be changed according to the velocity of the air going through the transmission line. The designed controller is composed of two parts. The one is a feedback controller, which is composed of a stabilizing filter, a compensating filter of modelling error and a nominal model of the force control system, to compensate the influence of transmission line and improve the feedback characteristics of the control system, and, the other is a feedforward controller to achieve the control performance. Control results with the designed controller show that the robustness and performance of the control system are improved compared to the control results with a fixed gain controller.

A Study on the Single Line-to-Ground Fault Analysis of HTS Power Cable (초전도 전력케이블의 1선 지락고장 특성 해석에 관한 연구)

  • Je, Hyang-Ho;Bang, Jong-Hyun;Kim, Jae-Ho;Sim, Ki-Deok;Jo, Jeon-Wook;Jang, Hyun-Man;Lee, Su-Kil;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.593-594
    • /
    • 2006
  • High temperature superconducting(HTS) power cable is expected to be used for power transmission lines supplying electric power for densely populated cities in the near future. Commercializing of HTS power cable is coming. Simulation is required for safety before install of HTS power cable, a fabrication model used at the power system simulation. In this paper, we shows a single line-to ground fault analysis in the grid system which has a loom length HTS power cable. The authors developed a single line-to ground fault current calculation method which is considering the shield layer of HTS power cable. In the calculation, the T type equivalent circuit is used to derive the mutual inductance of the HTS power cable

  • PDF

A Study on the Single Line-to-Ground Fault Analysis of HTS Power Cable (초전도 전력케이블의 1선 지락고장 특성 해석에 관한 연구)

  • Je, Hyang-Ho;Bang, Jong-Hyun;Kim, Jae-Ho;Sim, Ki-Deok;Jo, Jeon-Wook;Jang, Hyun-Man;Lee, Su-Kil;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2225-2226
    • /
    • 2006
  • High temperature superconducting(HTS) power cable is expected to be used for power transmission lines supplying electric power for densely populated cities in the near future. Commercializing of HTS power cable is coming. Simulation is required for safety before install of HTS power cable, a fabrication model used at the power system simulation. In this paper, we shows a single line-to ground fault analysis in the grid system which has a loom length HTS power cable. The authors developed a single line-to-ground fault current calculation method which is considering the shield layer of HTS power cable. In the calculation, the T type equivalent circuit is used to derive the mutual inductance of the HTS power cable.

  • PDF